Professional Documents
Culture Documents
RT61-RT70: Control System Conversion P140smart
RT61-RT70: Control System Conversion P140smart
RT61-RT70
Control system Conversion P140smart
V 03/2015
Printed in Switzerland
Regloplas AG
Flurhofstrasse 158
9006 St. Gallen
Switzerland
Tel.: +41-71-282 58 00
Fax.: +41-71-282 58 40
e-mail: info@regloplas.com
Homepage: www.regloplas.com
V 03/2015
Contents
General Safety Information 1
Safety Symbols ....................................................................................................... 1
Range of Application ............................................................................................... 2
Intended Use ........................................................................................................... 2
Safety Information ................................................................................................... 2
General Information ................................................................................... 2
Process Monitoring .................................................................................... 2
Information for Operators and Personnel .................................................. 3
Changing the Parameter Settings .............................................................. 3
Residual Risks ........................................................................................... 3
Using This Documentation ...................................................................................... 4
Additional Documentation .......................................................................... 4
Conversion Instructions 5
Retrofit Kit RT61 to RT70........................................................................................ 5
General Information ................................................................................... 5
Overview .................................................................................................... 5
Control system conversion instructions ..................................................... 6
Options conversion instructions ............................................................... 10
Retrofit Kit RT61 to RT70 (Parts lists) .................................................................. 13
Table 1 (Cables and Designations) ......................................................... 13
Parts list ................................................................................................... 14
Solenoid valve Set - coils with cables P140smart07 RT70 ..................... 15
Transformer wired with plug for RT70 (400 V)......................................... 16
Transformer wired with plug for RT70 (480 V)......................................... 16
Safety thermostat cable ........................................................................... 17
Option - MP1000 ...................................................................................... 17
Option - MP1001 ...................................................................................... 17
Option - MP1002 ...................................................................................... 17
Option - MP1003 ...................................................................................... 17
Option - MP1004 ...................................................................................... 17
Option - MP1005 ...................................................................................... 18
Option - MP1006 ...................................................................................... 18
Safety Symbols
DANGER
Denotes imminent danger.
Failure to heed the information can result in death or grave personal injury (dis-
ability)!
WARNING
Denotes a dangerous situation.
Failure to heed the information can result in death or grave personal injury (dis-
ability)!
CAUTION
Denotes a potentially dangerous situation.
Failure to heed the information can result in property damage as well as minor
or moderate personal injury!
NOTE
Denotes general information, useful advice to users and work recommenda-
tions, which, however, do not have any influence on the safety and health of
personnel.
Range of Application
This general safety information is generally valid for all temperature con-
trollers and control systems from Regloplas.
Intended Use
The Regloplas temperature control unit is built according to the current
state of the art and the generally accepted principles of safety engineer-
ing. The temperature control unit is intended solely for the normal use for
heating and/or cooling of injection moulds and die casting dies, extruders,
calenders, mixers and other consumers in areas where there is no risk of
explosion.
Any use beyond this shall be deemed to constitute improper use. The
manufacturer is not responsible for damage resulting from improper use;
the user is solely responsible for such risks. The temperature control unit
may not be used under other operating conditions and/or with other me-
dia, in deviation from our specifications, without the prior consent of
Regloplas AG.
The intended use also entails compliance with the operating, servicing
and maintenance conditions stipulated by the manufacturer. The temper-
ature control unit may only be operated, serviced and maintained by per-
sonnel who are familiar with these tasks and have been instructed as to
the risks.
Safety Information
General Information
The Regloplas temperature control unit is safe to operate but can cause
danger if it is used incorrectly or for a purpose other than its intended
use. It should be noted that any such incorrect use or non-compliance
with the intended use can cause risks to the life and limb of the user or
third parties, adverse effects on the equipment and other material assets
belonging to the user, and risks to the efficient operation of the equip-
ment.
Start-up (i.e., commencement of intended use) is prohibited until it has
been determined that the temperature control unit has been set up and
wired in accordance with the Machinery Directive (2006/42/EC).
EN 60204-1 (Safety of Machinery) must also be observed.
These operating instructions must be read carefully before switching on
and operating the temperature control unit. The information regarding the
intended use and foreseeable misuse must be observed. Local safety
regulations must also be obeyed.
If the temperature control unit is used in combination with products made
by other manufacturers, the notices and safety regulations of these man-
ufacturers must also be obeyed.
Process Monitoring
In plants in which a temperature control system malfunction leads to en-
dangerment of the operating personnel or destruction of the plant, an in-
dependent process monitor that shuts down the plant reliably must be
used.
Residual Risks
Any unauthorised modifications and changes to the temperature control
unit as well as unauthorised changes to the parameterisation of the con-
trol system are prohibited for reasons of safety.
If the temperature control unit is damaged, it must not remain in use; the
defective part must be replaced or repaired immediately. Only original
Regloplas replacement parts may be used. Damage due to use of third-
party parts voids any and all warranty claims.
DANGER
The temperature control unit must be rendered currentless before it is opened
(unplug mains plug and, if present, press the main switch on the temperature
control unit). Danger due to electrical shock!
Burning thermal oil can be extinguished using a spray foam fire extin-
guisher, a powder fire extinguisher (avoid with dust-sensitive plants, con-
trol systems, EDP, etc.) or a CO2 fire extinguisher. The appropriate fire
extinguisher must be provided by the operator, taking into account the
equipment located in the room and the mandatory safety regulations.
The temperature control unit may only be operated when all safety sys-
tems are completely installed and intact.
The temperature control unit must be protected against sprays and clean-
ing agents.
Before detaching connecting lines in the temperature control circuit and
depending on the outlet temperature, allow the temperature control unit
to cool down first and then turn it off. Check that the pump is no longer
running.
WARNING
NOTE
Additional Documentation
The included documentation is completely correct for the basic versions
of devices. Components that do not belong to the basic hardware are
noted as extra equipment. The corresponding additional documents are
included with special versions of devices. Any additional documents sup-
plement and/or replace the descriptions contained in this documentation,
which are then either invalid or only conditionally valid.
Conversion Instructions
General Information
This manual describes the subsequent conversion of the RT61 Control
system to the new RT70 Control system for the P140smart temperature
control unit.
CAUTION
The conversion of the control system may only be performed by trained and au-
thorized personnel!
Overview
Retrofit Kit RT61 to RT70
P140smart (400 V) Item no. 490-100057
P140smart (480 V) Item no. 490-100061
X10/Y2
X9/Y8
X12/Y6
Replace the solenoid valve coils (Y2, Y6, Y8) incl. ca- Install the protecting sleeves 220-100015 and
bles/plugs by new solenoid valve coils (230 VAC) 211-053747 on the cover 178-100010
Install the intermediate plate 178-100009 and the cover Transformer T5 (180-100026), ground wire, L=450
with four countersunk screws (M4x16) (191-100120), ground wire L=600 (191-100121)
Supply the cables on both sides with new designations Supply the cables on both sides with new designations
and replace the RT60/61 plugs by new RT70 plugs (for and replace the RT60/61 plugs by new RT70 plugs (for
details, see Table 1) details, see Table 1)
Install the side panels left and right. Put the tempera-
ture control unit into operation
NOTE
After finishing the conversion of the control system, the rotation direction of the
pump must be checked at the first start of the temperature control unit!
Install the MP1000 / MP1005 Option circuit board on Install the MP1000 Option bezel on the rear wall and
the RT70 Control system connect the plug to the circuit board
Option MP1001
Install the MP1001 Option circuit board on the RT70 Connect the plug cable to the circuit board (according
Control system to wiring diagram)
Option MP1002
Install the MP1002 Option circuit board on the RT70 Connect the plug cable to the circuit board (according
Control system to wiring diagram)
Option MP1003
Install the MP1003 Option circuit board on the RT70 Connect the flow rate meter cable to the circuit board
Control system (according to wiring diagram)
Option MP1004
Install the MP1002 Option circuit board on the RT70 Connect the plug cable to the circuit board (according
Control system to wiring diagram)
Install the MP1003 Option circuit board on the RT70 Connect the plug cable to the circuit board (according
Control system to wiring diagram)
Option MP1006
Connect the patch cable to the circuit board (according Connect the patch cable to the Profibus board (accord-
to wiring diagram) ing to wiring diagram)
Remove the existing Profibus interface, install the new Connect the Profibus interface connection cable in the
Profibus interface on the rear wall an connect it inside of the unit
HINWEIS
After finishing the conversion of the control system, the rotation direction of the
pump must be checked at the first start of the temperature control unit!
Parts list
Numb. Designation Item-No.
Solenoid valve coil Set with cable for P140smart07 RT70
1 pc. 350-100202
(for contents, see Assembly)
1 pc. Assembly Transformer, 100 VA, 400 V/1x230 V 180-100026
Assembly Transformer, 100 VA, 200-600 V/2x115 V
1 pc. 180-100027
(if not 400 V, instead of 180-100026)
Wire yellow/green, 1.5 m², L=450 mm
1 pc. 191-100120
(KS M4/End sleeve 8 mm)
Wire yellow/green, 1.5 m², L=600 mm
1 pc. 191-100121
(KS M4/End sleeve 8 mm)
RT70 Control System, complete with Main switch yel-
1 pc. 178-100001
low/red
Assembly Safety thermostat cable
1 pc. 193-100087
150-100011, L=110 cm/labelled
Connector Push-In 4-pin, T1-T2-T3-PE (RT70/RT100,
1 pc. 203-100007
Pump)
2 pcs. Connector Push-In 2-pin, 1-2 (RT70/RT100, Level/PT100) 203-100000
1 pc. Control system cover EVZ, RT70 178-100010
1 pc. Intermediate plate ST RT61 - RT70, RAL7016 178-100009
1 pc. Protecting sleeve Ø 41x100 220-100015
1 pc. Protecting sleeve SNAP M32 EPDM 211-053747
5 pcs. Cable tie 4.6x300 221-100004
Option - MP1000
Numb. Designation Item-No.
1 pc. RT70 Universal Interface option 178-100004
1 pc. RT70 cable, 20 mA CL, L=1600 mm (X51 X52) 178-100015
4 pcs. Hexagonal spacer (RT70 Options) 331-100017
2 pcs. Cylinder screw Torx, self-cutting, M3x6 330-069800
1 pc. Interface plate seal, IP54 340-100055
Option - MP1001
Numb. Designation Item-No.
1 pc. RT70 Analog Option 178-100003
4 pcs. Hexagonal spacer (RT70 Options) 331-100017
Option - MP1002
Numb. Designation Item-No.
1 pc. RT70 Digital Option with relay 178-100002
4 pcs. Hexagonal spacer (RT70 Options) 331-100017
Option - MP1003
Numb. Designation Item-No.
1 pc. RT70 Sn2/Pressure/Flow rate option 178-100005
4 pcs. Hexagonal spacer (RT70 Options) 331-100017
Option - MP1004
Numb. Designation Item-No.
1 pc. RT70 Digital Option with relay 178-100002
1 pc. RT70 Sn2/Pressure/Flow rate option 178-100005
8 pcs. Hexagonal spacer (RT70 Options) 331-100017
Option - MP1005
Numb. Designation Item-No.
1 pc. RT70 Universal Interface option 178-100004
1 pc. RT70 Universal Interface cable, L=1600mm 178-100014
4 Stck. Hexagonal spacer (RT70 Options) 331-100017
2 pcs. Cylinder screw Torx, self-cutting, M3x6 330-069800
1 pc. Interface plate seal, IP54 340-100055
Option - MP1006
Numb. Designation Item-No.
1 pc. RT70 RJ45 Adapter, Option Profibus 178-100008
1 pc. RT100/RT70 Profibus X65 176-100012
1 pc. RT70 Profibus Interface X65 extension cable 178-100016
4 pcs. Hexagonal spacer (RT70 Options) 331-100017
6 pcs. Cylinder screw Torx, self-cutting, M3x6 330-069800
2 pcs. Interface plate seal, IP54 340-100055