Professional Documents
Culture Documents
Key Final Concret and Answer Saify by Suhaib Zraiqat
Key Final Concret and Answer Saify by Suhaib Zraiqat
Is :
A-Cylinder100 × 200mm B-Cube 150*150*150mm C-cube 300*300*300
D-Cylinder 150*300
2-The Assumed state Of stress When Testing the concrete Compression Strength
Which Cause A Shear Stress Is :
t
qa
A-Tri-axial B-Uni-axial C- Bi-Axial D-None
ai
3-The Standard Factor Which Affect The Measured Compressive Strength Of The
Concrete is :
6- When Testing The Concrete Compressive Strength , Applying The load At A high
Rate Leads To Achieve :
A-) specimen (A) Would Achieve Higher Strength Than specimen (B)
B-) specimen (A) Would Achieve Lower Strength Than specimen (B)
t
C-) specimen (A) Would Achieve The Same Strength As specimen (B)
qa
D-) We Can Never Know Which One Has Higher Compressive Strength
ai
8-The ASTM Standard Test For The Tensile Strength Is Direct Tensile :
A-True B-False
Zr
9- For The Following Flexural Strength Test , If You Know That The Sample Was Broke
Between The Loads , At A Load Of 10KN . Based On the Geometric Date In The Figure
Below , The Flexural Strength Of The Sample Is :
ib
ha
Su
t
qa
11- If The Compressive Strength Of A Standard Cube Was 55 Mpa , Then The
Estimated Flexural Tensile Strength Is
ai
Zr A- 50.5Mpa B-10.08 Mpa C-7.04Mpa D-60Mpa
12-If The Compressive Strength Of A Standard Cube Was 70 Mpa , Then The
Estimated Splitting Tensile Strength Is
ib
14- 3 Concrete Mix's A , B , C and ,, Has W/C Ratio Of 0.26 , 0.45 , 0.7
One Of Following Statement's Is Correct :
16- Tow Concrete Mix's Where Prepared , MiX (A) using Crushed And Rough Texture
Aggregate , And Mix (B) Using Smooth Gravel Aggregate . For The Same Degree Of
Workability, One Of The Following Statement Is Correct :
t
qa
A- Strength Of Mix A Is Higher Than Mix B
B- Strength Of Mix B Is Higher Than Mix A
C- Mix (A) And Mix (B) Has The Same Strength
ai
D-None
Zr
17- The Typical Value Of Possion's Ratio For Normal Concrete Is About :
A-) 0.40-0.50 B-) 0.15-0.20 C-) 0.10-0.15 D-)0.05-0.10
ib
18- A Concrete Core Was Drilled Horizontally From a Wall And Tested To Have A
ha
Strength Of 25Mpa . The Core Was Taken From A Plain Concrete .if λ was Set To
Equal (D/2) , Then The Estimated Cube Strength For The Tested Core Is :
t
D-(A & B & C) Are Rejected
qa
20- In A Schmidt Hammer Test , The Was Hammer Set Vertically Up On A Wet
ai
Concrete Wall . The Rebound Nubmer Was 30 . Based On the Previous Information
And Using The Below Chart, The Compressive Strength Of The Tested Concrete Is
About :
Zr
ib
ha
Su
t
qa
ai
Zr
ib
ha
t
24-If The PH Number in A steel Reinforcing Bar Became Less Than 11 , One Of The
qa
Following Statements Is Not Correct :
ai
D- Passivity Layer Gets Doubled
25- The Presence Of Reactive forms of silica , Sufficient alkali , And Sufficient
Zr
moisture within the concrete , Can Leads To :
D-None
A- Lower Strength
B- Increase shrinkage
C-(A+B)
D-None
29- In Order To Use Pumped Concrete , The Pump Diameter Must Be At Least :
t
A- 2 Dmax
qa
B- 5 Dmax
C- 3 Dmax
D- 0.5 Dmax
ai
30- The Result Of Placing The Concrete in The Way Showed In The Figure Below Is :
Zr
ib
ha
31- The Most Suitable Method For Placing The Concrete In Deep Forms :
A-Shotcrete
B-Tremine
C-Pre-Placed Aggregate
D-None
32- Three Concrete Colum's (A) , (B) And (C) Where Casted Using The Same Mix ,
Colum A Was Casted In The Desert , Colum B Was Casted To Support A Bridge
Hanging Over See Water , And Colum C Was Casted Over A high Sulfated Soil . The
Colum That’s Going To Suffer Reinforcment Corrosion First Is :
A- Colum A
B- Colum B
C- Colum C
t
D- All Of Them Will Suffer Corrosion At The Same Time
qa
ai
******************Answer Questions 33-40 Using The Following Date
Concrete Is Required For The Bluding For An Exterior Column Located Above The
Ground Level In An Area Where Substantial Freeze and Thaw Cycles May Occour .
Zr
The Concrete Required To have An Avarage 28-day Compressive Strength Of 25Mpa .
The Slump Is Between 50-80mm , And The Maximum Aggregate Size Is 25mm. Using
Concrete Type (1) With Specific Gravity of 3.15
t
qa
35- The Weight Of The Coarse Aggregate Used In this Mix In (SSD) Condition is :
ai
A-1020Kg/m3 B-1173Kg/m3 C- 1055Kg/m3 D-1125Kg/m3
Zr
36- The weight Of The Fine Aggregate Needed For The Concrete Mix is :
ib
t
qa
ai
Zr
40-The Avarage Compressive Strength For The Design Of A Concrete Mix , If The
Specified Compressive Strength Is 28 MPa , And The Standard Deviation Used Where
Obtained Using 25 Consecutive Test is 3.5 :
ib
t
12 A
qa
13 D
14 B
15 A
16 C
17 B
18 A
ai
19 B
20 B
21 A
22 C
Zr
23 A
24 D
25 C
26 A
27 D
28 C
ib
29 C
30 B
31 B
32 B
ha
33 C
34 B
35 B
36 A
37 C
Su
38 B
39 D
40 A