VLT® Drives FC Series

Option Overview
Options and accessories available for VLT® HVAC Drive, VLT® Refrigeration Drive,
VLT® AQUA Drive and VLT® AutomationDrive.

Configure
the fully-flexible
VLT® drive with the
right options to meet
your exact needs

www.danfoss.com/drives
A options: Fieldbuses

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Fieldbuses
FC 102 FC 103 FC 202 FC 301 FC 302
VLT® PROFIBUS DP MCA 101 n n n n n
VLT® DeviceNet MCA 104 n n n n
VLT® PROFINET MCA 120 n n n n n
VLT® EtherNet/IP MCA 121 n n n n
VLT® Modbus TCP MCA 122 n n n n
VLT® POWERLINK MCA 123 n n
VLT® EtherCAT MCA 124 n n
VLT® AK-LonWorks MCA 107 n
VLT® LonWorks MCA 108 n
VLT® PROFIBUS Converter MCA 113 n
VLT® PROFIBUS Converter MCA 114 n
VLT® CANopen MCA 105 n n
VLT® BACnet MCA 109 n
VLT® DeviceNet Converter MCA 194 n
For more information about built-in RS485 protocols consult the individual frequency converter design guide.

VLT® PROFIBUS DP MCA 101 VLT® PROFINET MCA 120 The MCA 121 offers advanced features as:
 Built-in high performance switch enabling
Operating the frequency converter via a field- VLT® PROFINET MCA 120 uniquely combines line and ring topology, and eliminating the
bus enables you to reduce the cost of your sys- the highest performance with the highest de- need for external switches
tem, communicate faster and more efficiently, gree of openness. The MCA 120 gives the user  Advanced switch and diagnosis functions
and benefit from an easier user interface. access to the power of Ethernet. The option is  Built-in web server
designed so that many of the features from the  E-mail client for service notification
VLT® PROFIBUS DP MCA 101 provides: PROFIBUS MCA 101 can be reused, minimising  Unicast and Multicast communication
 Wide compatibility, a high level of avail- user effort to migrate to PROFINET, and secur-
ability, support for ­major PLC vendors, and ing the investment in PLC program. Ordering number
compatibility with future versions 130B1119 standard, 130B1219 coated
 Fast, efficient communication, transpar- Other features:
ent installation, advanced diagnosis and  Built-in high performance switch enabling
parameterisation and auto-­configuration of
process data via GSD-file
line and ring topology, and eliminating the
need for external switches VLT® Modbus TCP MCA 122
 Acyclic parameterisation using  Built-in web server for remote diagnosis and Modbus TCP is the first industrial Ethernet-
PROFIBUS DP-V1, P ­ ROFIdrive or Danfoss reading basic drive parameters based protocol for automation. The VLT® Mod-
FC profile state machines, ­PROFIBUS DP-V1,  Support of DP-V1 Diagnostic allows easy, bus TCP MCA 122 connects to Modbus TCP
Master Class 1 and 2 fast and standardized handling of warning based networks. It is able to handle connec-
and fault information into the PLC, improv- tion interval down to 5 ms in both directions,
Ordering number ing bandwidth in the system positioning it among the fastest performing
130B1100 standard, 130B1200 coated Modbus TCP devices in the market. For master
PROFINET encompasses a suite of messages redundancy it features hot swapping between
and services for a variety of manufacturing two masters.
VLT® DeviceNet MCA 104 automation applications, including control,
configuration and information. Other features:
VLT® DeviceNet MCA 104 offers robust,  Built-in web-server for remote diagnosis
efficient data handling thanks to advanced Ordering number and reading basic drive parameters
Producer/Consumer technology. 130B1135 standard, 130B1235 coated  Configure an email notification to send an
email message to one or more recipients,
 This modern communications model offers when certain alarms or warnings occur, or
key ­capabilities that let you effectively
determine what i­nformation is needed and
VLT® EtherNet/IP MCA 121 are cleared.
when Ethernet is the future standard for communica- Ordering number
 Benefit also from ODVA’s strong ­conform- tion at the factory floor. The VLT® EtherNet/IP 130B1196 standard, 130B1296 coated
ance ­testing policies, which ensure that MCA 121 is based on the newest technology
products are ­interoperable available for industrial use and handles even
the most demanding requirements. EtherNet/
Ordering number IP extends commercial off-the-shelf Ethernet
130B1102 standard, 130B1202 coated to the Common Industrial Protocol (CIP™) – the
same upper-layer protocol and object model
found in DeviceNet.

2 Danfoss VLT Drives · DKDD.PB.400.A4.02


VLT® POWERLINK MCA 123 VLT® LonWorks MCA 108 VLT® CANopen MCA 105
VLT® POWERLINK MCA 123 represents the LonWorks is a fieldbus system developed for High flexibility and low cost are two of
second generation of fieldbus. The high bit building automation. It enables communica- the “cornerstones” for CANopen. The VLT®
rate of industrial Ethernet can now be used to tion between individual units in the same CANopen MCA 105 option for the VLT®
make the full power of IT technologies used in system (peer-to-peer) and thus supports Auto­mationDrive is fully equipped with both
the automation world available for the factory decentralising of control. high priority access to control and status of
world. the Drive (PDO Communication) and access

No need for big main station (master- to all Parameters through acyclic data (SDO
POWERLINK provides not only high perfor- follower) Communication).
mance real-time and time synchronisation 
Units receive signals directly
features. Due to its CANopen-based commu- 
Supports Echelon free-topology interface For interoperability the option has imple-
nication models, network management and (flexible cabling and installation) mented the DSP402 AC drive Profile. This all
device description, the MCA 123 offers much 
Supports embedded I/Os and I/O options guarantees standardised ­handling, interoper-
more than just a fast communication network. (easy implementation of de-central I/Os) ability and low cost.

Sensor signals can quickly be moved to
The perfect solution for: another controller via bus cables Ordering number
 Dynamic motion control applications 
Certified as compliant with LonMark ver. 3.4 130B1103 standard, 130B1205 coated
 Material handling specifications
 Synchronisation and positioning
Ordering number
­applications
130B1106 standard, 130B1206 coated VLT® BACnet MCA 109
Ordering number The open communications protocol for
130B1489 standard, 130B1490 coated worldwide building automation. The BACnet
VLT® PROFIBUS protocol is an international protocol that
efficiently integrates all parts of building auto-
VLT® EtherCAT MCA 124 Converter MCA 113 mation equipment from the actuator level to
the building management system.
The VLT® PROFIBUS Converter MCA 113 is a
The VLT® EtherCAT MCA 124 offers connectivity special version of the PROFIBUS options that
to EtherCAT based networks via the EtherCAT Via the BACnet option it is possible to read
emulates the VLT® 3000 commands in the
Protocol. The option handles the EtherCAT line all analogue and digital inputs and control all
VLT® AutomationDrive. The VLT® 3000 can then
communication in full speed, and connection analogue and digital outputs of the VLT® HVAC
be replaced by the VLT® AutomationDrive, or
towards the drive of an interval down to 4 ms Drive. All inputs and outputs can be operated
the system can be expanded without costly
in both directions. This allows the MCA124 to independently of the functions of the drive,
change of the PLC program.
participate in networks from low performance and thus work as remote I/Os:
up to servo applications. For upgrade to a different fieldbus, the 
COV (Change of Value)
installed converter is easily removed and

EoE Ethernet over EtherCAT support 
Read/write Property Multiple
replaced with a new option. This secures the

CoE (CAN Over Ethernet) for access to Drive 
Alarm/Warning handling
investment without losing flexibility.
parameters.

SMTP (Simple Mail Transfer Protocol) for e- Ordering number
Ordering number
mail notification 130B1144 standard, 130B1244 coated
130B1245 coated

TCP/IP for easy access to Drive configuration
data from MCT 10

Ordering number VLT® PROFIBUS VLT® DeviceNet


NA standard, 130B5646 coated Converter MCA 114 Converter MCA 194
The VLT® DeviceNet Converter MCA 194
The VLT® PROFIBUS Converter MCA 114 is a emulates VLT® 5000 commands in the VLT®
VLT® AK-LonWorks MCA 107 special version of the Profibus options that
emulates the VLT® 5000 commands in the AutomationDrive. This means that a VLT® 5000
can be replaced by the VLT® AutomationDrive
VLT® AK-LonWorks MCA 107 is a complete VLT® AutomationDrive.The VLT® 5000 can then or an existing system can be expanded, with-
electronic refrigeration and control system be replaced by the VLT® AutomationDrive, or out costly change of the PLC program.
for monitoring and controlling refrigeration the system can be expanded without costly
plants. Connecting this drive to an ADAP- change of the PLC program. For a later upgrade to a different fieldbus, the
KOOL® Lon network is really simple. After en- installed converter can easily be removed and
tering a network address, press a service pin to For upgrade to a different fieldbus, the replaced with a different option. This secures
start the automatic configuration procedure. installed converter is easily removed and the investment without losing flexibility. The
replaced with a new option. This secures option emulates I/O instances & explicit mes-
Ordering number the investment without losing flexibility. The sages of a VLT® 5000.
130B1169 standard, 130B1269 coated option supports DPV1.
Ordering number
Ordering number 130B5601 coated
130B1246 coated

Danfoss VLT Drives · DKDD.PB.400.A4.02 3


B options: Functional extensions

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Functional extensions
FC 102 FC 103 FC 202 FC 301 FC 302
VLT® General Purpose I/O MCB 101 n n n n n
VLT® Encoder Input MCB 102 n n
VLT® Resolver Input MCB 103 n n
VLT® Relay Card MCB 105 n n n n n
VLT® Analog I/O MCB 109 n n n
VLT® PTC Thermistor Card MCB 112 n n n
VLT® Sensor Input MCB 114 n n n n
VLT® Programmable I/O MCB 115 n
VLT® Safety Option MCB 140 n n n
VLT® Safety Option MCB 141 n n n
VLT® Safety Option MCB 150 n
VLT® Safety Option MCB 151 n
VLT® Safety Option MCB 152 n
VLT® Extended Cascade Controller MCO 101 n
VLT® Safe PLC I/O MCB 108 n n

VLT® General Purpose I/O VLT® Resolver Input VLT® Analog I/O MCB 109
MCB 101 MCB 103 This analogue input/output option upgrades
This I/O option offers an extended number of the frequency converter to advanced
This option enables connection of a resolver to
­control inputs and outputs: performance and control using the additional
provide speed feedback from the motor. in/outputs.This option also provides battery
 3 digital inputs 0-24 V: back-up supply for the built-in clock to
 Primary voltage...........................................2 – 8 Vrms ensure reliable operation of all clock-based
Logic ‘0’ < 5 V; Logic ‘1’ > 10V  Primary frequency........................2.0 kHz – 15 kHz
 2 analogue inputs 0-10 V: functionality, such as timed actions.
 Primary current max................................50 mA rms
Resolution 10 bit plus sign  Secondary input voltage..............................4 Vrms
 2 digital outputs NPN/PNP push pull  3 analogue inputs, each configurable as
 Spring-loaded connection
 1 analogue output 0/4-20 mA both voltage and temperature input
 Connection of 0-10 V analogue signals as
 Spring-loaded connection Ordering number well as PT1000 and NI1000 temperature
130B1127 standard, 130B1227 coated
Ordering number inputs
130B1125 standard, 130B1212 coated  3 analogue outputs each configurable as
0-10 V outputs
VLT® Relay Card  Incl. back-up supply for the standard clock
VLT® Encoder Input MCB 105 function in the frequency converter

MCB 102 Makes it possible to extend relay functions


with 3 a­ dditional relay outputs.
The back-up battery typically lasts for 10 years,
depending on environment.
This option offers the possibility to connect
various types of incremental and absolute  Max switch rate at rated Ordering number
encoders. The connected encoder can be used load/min. load ................................ 6 min-1/20 sec-1 130B1143 standard, 130B1243 coated
for closed loop speed control as well as closed  Protects control cable connection
loop flux motor control.  Spring-loaded connection
The following encoder types are supported: Max. terminal load:
VLT® PTC Thermistor Card
 5V TTL (RS 422)  AC-1 Resistive load ............................. 240 V AC 2 A MCB 112
 1VPP SinCos  AC-15 Inductive
 SSI The VLT® PTC Thermistor Card MCB 112 enables
load @cos fi 0.4 .................................240 V AC 0.2 A
 improved surveillance of the ­motor ­condition
Hiperface  DC-1 Resistive load ................................24 V DC 1 A
 compared to the built-in ETR ­function and
EnDat  DC-13 Inductive thermistor terminal.
load @cos fi 0.4 ................................... 24 V DC 0.1 A
Ordering number
 Protects the motor from overheating
130B1115 standard, 130B1203 coated Min. terminal load:  ATEX approved for use with Ex d, Ex e, Ex
 DC 5 V.........................................................................10 mA n, Ex tb and Ex tc motors (EX e and n only
FC 302)
Ordering number  Uses Safe Torque Off function, which is
130B1110 standard, 130B1210 coated approved in accordance with SIL 2 IEC
61508
 Spring-loaded connection

Ordering number
130B1137 coated

4 Danfoss VLT Drives · DKDD.PB.400.A4.02


VLT® Sensor Input VLT® Safety Option VLT® Extended Cascade
MCB 114 MCB 150 and MCB 151 Controller MCO 101
The option protects the motor from being The VLT® Safety Options MCB 150 and MCB This option upgrades the built-in cascade
overheated by monitoring the bearings and 151 expand the Safe Torque Off (STO) function, controller to operate more pumps and more
windings temperature in the motor. which is integrated in a standard VLT® advanced pump control in master/follower
AutomationDrive. mode.
 Protects the motor from overheating
 Three self-detecting sensor inputs for 2 or 3 By using the Safe Stop 1 (SS1) function it is MCO 101 supports the combination of
wire PT100/PT1000 sensors possible to perform a controlled stop before multiple variable speed and fixed speed
 One additional analogue input 4-20 mA removing torque. Using the Safely Limited pumps, as well as configurations with pumps
Speed SLS function it is able to monitor of differing capacity (mixed pump control).
Ordering number whether a specified speed is exceeded.
130B1172 standard, 130B1272 coated  Up to 6 pumps in standard cascade setup
The functions can be used up to PL d  Up to 6 pumps in master/follower or mixed
according to ISO 13849-1 and SIL 2 according pump setup
VLT® Programmable I/O to IEC 61508.  Technical specifications:
See VLT® Relay Option MCB 105
MCB 115  Additional safety functions for compliance
with standards Ordering number
The MCB 115 option has 3 outputs and 3  Replacement of external safety equipment 130B1118 standard, 130B1218 coated
inputs, and extends the I/O selection available  Reduced space requirements
on the control card. For example, it can be  2 safe programmable inputs
used to achieve multi-zone control with 3
pressure transmitters.


1 safe output (for T37)
Easier machine certification VLT® Safe PLC I/O MCB 108
 Drive can be powered continuously The VLT® AutomationDrive FC 302 provides a
 Convert the frequency converter into a  Safe LCP Copy safety input based on a single pole 24 V DC
decentralized I/O block supporting building  Dynamic commissioning report input.
automation systems with inputs and  TTL (MCB 150) or HTL (MCB 151) encoder as
outputs speed feedback  For the majority of applications this input
 Support the extended PI controllers with enables the user to implement safety in a
I/Os for setpoint inputs, transmitter/sensor Ordering number cost-effective way. For applications that
inputs, and outputs for actuators 130B3280 MCB 150, 130B3290 MCB 151 work with more advanced products such
 Provide a digital output used for: as Safety PLC or light curtains, the MCB 108
 Driving a relay interface enables the connection of a two-
 Input to commonly used PLC I/O cards
 Input to another frequency converter in a VLT® Safety Option MCB 152 wire safety link
 The MCB 108 Interface allows the Safe PLC
sequentially-controlled application The VLT® Safety Option MCB 152 operates the to interrupt on the plus or the minus link
safety functions of a frequency converter via without signal interference
Ordering number the PROFIsafe fieldbus in combination with
130B1266 VLT® PROFINET MCA 120 fieldbus option. It im- Ordering number
proves flexibility by connecting safety devices 130B1120 standard, 130B1220 coated
within a plant.
VLT® Safety Option
MCB 140 and MCB 141 Central and decentral drives located at differ-
ent machinery cells can easily be intercon-
VLT® Safety Option MCB 140 and MCB 141 nected with the PROFIsafe safety fieldbus. This
comprise safety options providing Safe Stop interconnection enables activation of Safe
1 (SS1), Safely Limited Speed (SLS) and Safe Torque Off (STO) irrespective of where a hazard
Speed Monitor (SSM) functionallity. occurs. The safety functions of the MCB 152 are
implemented according to EN IEC 61800-5-2.
The options can be used up to PL e according
to ISO 13849-1. The MCB 152 supports PROFIsafe functionality
to activate integrated safety functions of the
MCB 140 is a standard B-Option while MCB 141 VLT AutomationDrive from any PROFIsafe host,
offers the same functionallity in an external up to Safety Integrity Level SIL 2 according to
45 mm housing. MCB 141 enables the user to EN IEC 61508 and EN IEC 62061, Performance
use the MCB 140 functionallity also if another Level PL d, Category 3 according to EN ISO
B-Option is used. 13849-1.

Different operating modes can be easily Features:


configured by using the on board display  PROFIsafe device (in combination with
and buttons. The options provide only a MCA 120)
limited set of parameters for easy and fast  Replacement of external safety equipment
parameterization.  Reduced space requirements
 2 safe programmable inputs
 MCB 140 standard B-Option  1 safe output (for T37)
 MCB 141 external option  Easier machine certification
 Single channel or dual channel operation  Drive can be powered continuously
possible  Safe LCP Copy
 Proximity switch as speed feedback  Dynamic commissioning report
 SS1, SLS and SMS functionallity
 Easy and fast parameterization Ordering number
130B9860 coated
Ordering number
130B6443 MCB 140, 130B6447 MCB 141

Danfoss VLT Drives · DKDD.PB.400.A4.02 5


C options: Motion control, advanced cascade
controller and extended relay card
Motion controls and VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
extended relay card FC 102 FC 103 FC 202 FC 301 FC 302
VLT® Motion Control Option MCO 305 n n
VLT® Synchronizing Controller MCO 350 n n
VLT® Positioning Controller MCO 351 n n
VLT® Advanced Cascade Controller MCO 102 n
VLT® Extended Relay Card MCB 113 n n n n n

VLT® Motion Control VLT® Synchronizing VLT® Advanced Cascade


Option MCO 305 Controller MCO 350 Controller MCO 102
The MCO 305 is an integrated programmable The VLT® Synchronizing Controller MCO 350 for Easy to fit, the VLT® Advanced Cascade Control-
motion controller for VLT® AutomationDrive VLT® AutomationDrive expands the functional ler MCO 102 upgrades the built-in cascade
range. The option adds fuctionality and properties of the frequency converter in controller to operate up to 8 pumps and more
flexibility to the already very comprehensive synchronizing applications, and replaces advanced pump control in master/follower
standard functionality of these drives. traditional mechanical solutions. mode. MCO 102 supports the combination
of multiple variable speed and fixed speed
VLT® Motion Control Option MCO 305 offers a  Speed synchronizing pumps, as well as configurations with pumps
variety of easy to use motion functions which  Position (angle) synchronizing with or of differing capacity (mixed pump control).
in combination with the programmability without marker correction
makes it the ideal solution for all types of posi-  On-line adjustable gear ratio The additional 7 digital inputs and the 24 V DC
tioning and synchronizing applications.  On-line adjustable position (angle) offset connection to the drive enable flexible adapta-
 Encoder output with virtual master function tion to the application. The same cascade
 Synchronisation (electronic shaft), position- for synchronization of multiple followers controller hardware is compatible with for the
ing and electronic cam control  Control via I/O’s or fieldbus entire power range up to 2 MW.
 2 separate interfaces supporting both  Home function
incremental and absolute encoders  Configuration as well as read-out of status  Up to 8 pumps in standard cascade setup
 CANOpen motion bus for interconnection and data via the Local Control Panel of the  Up to 8 pumps in master/follower or mixed
of several drives drive. pump setup
 1 encoder output (virtual master function)
 10 digital inputs (additional inputs on Ordering number Ordering number
control card and B-option) 130B1152 standard, 130B1252 coated 130B1154 standard, 130B1254 coated
 8 digital outputs (additional inputs on
control card and B-option)
 Support of CANOpen encoders and I/O
modules VLT® Positioning VLT® Extended Relay Card
 Sends and receives data via fieldbus Controller MCO 351 MCB 113
­interface (requires fieldbus option)
 Definition of user/application specific The VLT® Positioning Controller MCO 351 offers The VLT® Extended Relay Card MCB 113 adds
parameters on Local Control Panel a host of user-friendly benefits for positioning inputs/outputs for increased flexibility.
 PC software: Program and Cam editor applications in many industries. It is based
including tools for debugging and commis- on a range of carefully thought-through and  7 digital inputs
sioning innovative features.  2 analogue outputs
 Structured text programming language  4 SPDT relays
offering both cyclic and event driven  Relative positioning  Meets NAMUR recommendations
execution  Absolute positioning  Galvanic isolation capability
 Touch probe positioning
Ordering number  End limit handling (software and hardware Ordering number
130B1134 standard, 130B1234 coated  Control via I/O’s or fieldbus 130B1164 standard, 130B1264 coated
 Mechanical brake handling (programmable
hold delay)
 Error handling
 Jog speed/manual operation
 Marker related positioning
 Home function
 Configuration as well as read-out of status
and data via the Local Control Panel of the
drive

Ordering number
130B1153 standard, 130B1253 coated

6 Danfoss VLT Drives · DKDD.PB.400.A4.02


D option: 24 V back-up power supply

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
24 V back-up power supply
FC 102 FC 103 FC 202 FC 301 FC 302
VLT® 24 V DC Supply MCB 107 n n n n n

VLT® 24 V DC Supply  Input voltage range


MCB 107 
24 V DC +/- 15% (max. 37 V for 10 sec.)
Max. input current ............................................... 2.2 A
An external 24 V DC supply can be installed  Max. cable length ................................................75 m
for low-voltage supply to the control card and  Input capitance load ................................... < 10 uF
any option card installed. This enables full  Power-up delay ..................................................< 0.6 s
operation of the LCP (including the parameter
setting) and all installed options without con- Ordering number
nection to mains. 130B1108 standard, 130B1208 coated

Danfoss VLT Drives · DKDD.PB.400.A4.02 7


Power Options

VLT® Brake Resistor MCE 101 


Enclosure protection as IP20 and up to IP65

Build-in thermo switch
Energy generated during braking is absorbed 
Versions for vertical and horizontal
by the resistors, protecting electrical compo- mounting
nents from heating up. Danfoss brake resistors 
UL-recognized – a selection of the vertical-
are optimized for the FC-series and general mounted units is UL-recognized
versions for horizontal and vertical motion are
available.

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
See relevant n n n n
Design Guide

VLT® Advanced Harmonic 


AHF 010 reduces total harmonic current
distortion to 10%
Filter AHF 005 and AHF 010 
Small compact housing that fits into a panel
Achieve easy, effective harmonic distortion 
Easy to use in retrofit applications
reduction by connecting the AHF 005 and AHF 
User-friendly start-up – no adjustment
010 harmonic filters at the input to a Danfoss necessary
frequency converter. 
No routine maintenance required

VLT® FC series family look

AHF 005 reduces total harmonic current
distortion to 5%

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
See relevant n n n n n
Design Guide

VLT® Sine-wave Filter 


Reduces motor insulation stress

Reduces acoustic noise from the motor
MCC 101 
Reduces bearing currents (especially in
Position the VLT® Sine-wave Filter between the large motors)
frequency converter and the motor to provide 
Reduces losses in the motor
a sinusoidal phase-to-phase motor voltage. 
Prolongs service lifetime
The filter reduces motor insulation stress, 
VLT® FC series family look
acoustic noise from the motor, and bearing
currents (especially in large motors).

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
See relevant n n n n n
Design Guide

VLT® dU/dt Filter MCC 102 


These filters reduce stress on the motor’s
insulation and are recommended in ap-
VLT® dU/dt filters are placed between the plications with older motors, aggressive
frequency converter and the motor to environments or frequent braking which
eliminate very fast voltage changes. cause increased DC link voltage.
The motor terminal phase-to-phase voltage 
VLT® FC series family look
is still pulse shaped but its dU/dt values are
reduced.

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
See relevant n n n n n
Design Guide

8 Danfoss VLT Drives · DKDD.PB.400.A4.02


VLT® Common Mode Filter 
Extend motor bearing lifetime

Can be combined with dU/dt and
MCC 105 sine-wave filters
Common mode filters are placed between the 
Reduce radiated emissions from the motor
frequency converter and the motor. cable
They are nano-crystalline cores that mitigate 
Easy to install – no adjustments necessary
high frequency noise in the motor 
Oval shaped – allows mounting inside the
cable (shielded or unshielded) and reduce frequency converter enclosure or motor
bearing currents in the motor. terminal box

Ordering Encl. VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: size FC 102 FC 103 FC 202 FC 301 FC 302
130B3257 A and B n n n n n
130B7679 C1 n n n n n
130B3258 C2, C3,
n n n n n
C4
130B3259 D n n n n n
130B3260 E and F n n n n n

VLT® Line Reactor MCC 103 When planning load sharing applications,
pay special attention to different enclosure
The VLT® Line Reactor MCC 103 programme type combinations and inrush concepts.
ensures balanced current sharing in load For technical advice regarding load sharing
sharing applications, where the DC-side of applications, contact Danfoss application
the rectifier of multiple drives is connected support.
together.
Ordering numbers: Refer to MCC 103
For applications using load sharing, the MCC specifications on the website:
103 is UL-recognized and is compatible with http://vlt-drives.danfoss.com/products/power-
options/vlt-line-reactor-mcc-103/

VLT® AutomationDrive, VLT® AQUA Drive
and VLT® HVAC Drive

50 Hz or 60 Hz mains supply

LCP

VLT® Control Panel LCP 101 


Status messages

Quick menu for easy commissioning
The numerical control panel offers a basic MMI 
Parameter setting and adjusting
to the drive. 
Hand-operated start/stop function or
Automatic mode select

Reset function

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
130B1124 n n n n

VLT® Control Panel LCP 102 


Adjusting of parameters

Full parameter backup and copy function
The graphical control panel offers a highly 
Alarm logging
user-friendly MMI to the drive. 
Info button – explains the function of the
selected item on display

Multi-language display 
Hand-operated start/stop, or Automatic

Status messages mode selection

Quick menu for easy c­ ommissioning 
Reset function

Parameter setting and explanation of 
Trend graph
parameter function

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
130B1107 n n n n n

Danfoss VLT Drives · DKDD.PB.400.A4.02 9


LCP

LCP Panel Mounting Kit


All ordering numbers are for IP55/66 and
include fasteners and a gasket.

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
130B1113:
With fasteners, n n n n n
gasket, graphical
LCP and 3 m cable
130B1114:
With fasteners, n n n n
gasket, numerical
LCP and 3 m cable
130B1117:
With fasteners,
gasket and with- n n n n n
out LCP and with
3 m cable
130B1129:
With fasteners,
gasket, blind cover n n n n n
and 8 m “free end”
cable
130B1170: With
fasteners, gasket n n n n n
and without LCP

Accessories

For use with option A


VLT® PROFIBUS Adapter Adapter Sub-D9 Connector allows the use
of these connectors throughout all installed
Sub-D9 Connector devices. Use of Sub-D9 cabling allows easy
In some industries, the use of Sub-D9 connec- access for diagnosis tools and programming
tors is used as standard. The VLT® PROFIBUS devices.

Ordering Encl. VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: size FC 102 FC 103 FC 202 FC 301 FC 302
130B1112 A1, A2 n n n n n
and A3
176F1742 D and E n n n n n

IP 21/Type 1 conversion kit 


Supports VLT® drives from 1.1 to 90 kW (NO)

Used on standard VLT® drive with or with-
The IP21/Type 1 conversion kit is used for out mounted option modules
installation of VLT® drives in dry environments.  IP 41 on top side
The enclosure kits are available for enclosure  PG 16 and PG 21 holes for glands
sizes A1, A2, A3, B3, B4, C3 and C4

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
130B1121 n n
Encl. size A1
130B1122 n n n n n
Encl. A2
130B1123 n n n n n
Encl. A3
130B1187 n n n n n
Encl. B3
130B1189 n n n n n
Encl. B4
130B1191 n n n n n
Encl. C3
130B1193 n n n n n
Encl. C4

10 Danfoss VLT Drives · DKDD.PB.400.A4.02


Leakage Current 
Measuring current transformer, inside diam-
eter 20 mm/35 mm
Monitor Modules 
Measuring range 500 mA
The leakage current monitoring modules 
Measuring time ≤ 180 ms
RCMB20-500-01 and RCMB35-500-01 are used 
Supply voltage 24 V DC
for fault current monitoring in applications, 
Analogue output current 4-20 mA
where frequency converters are used, and 
CT connection monitoring using cyclical
direct and/or alternating fault currents are test current
likely to occur. Each module has to be installed 
LEDs: power On LED, alarm LED
and connected in the cable connection
compartment in front of the mains input of Ordering number: Enclosure number:
the frequency converter. Both variants of the 130B5645 A2 and A3
modules provide an output signal 4...20 mA
proportional to the high frequency leakage 130B5764 B3
current. 130B5765 B4
130B6226 C3

AC/DC sensitive measured value acquisition

Frequency range 0-500 Hz 130B5647 C4

USB extension cable USB extension for A5-B1 enclosures,


350 mm cable .....................................................130B1155
The USB extension cable for IP55 and IP66 USB extension for B2-C enclosures,
enclosures makes the USB connector available 650 mm cable...................................................... 130B1156
outside the drive. The USB extension is
designed for mounting in a cable gland in
the bottom of the drive, which makes PC
communication very easy even in drives with
high IP rating.

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
130B1155 n n n n n
350 mm cable
130B1156 n n n n n
650 mm cable

Adapter Plate for VLT® 3000


and VLT® 5000
Use the adapter plate when replacing
VLT® 3000 or VLT® 5000 with an FC series
frequency converter.

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
130B0056 * n n n n
* To be used only for IP 20/NEMA type 1 units up to 7.5 kW

Decoupling Plate for


Fieldbus Cables
For use with option A.
Strengthens fieldbus mounting.

Ordering VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number: FC 102 FC 103 FC 202 FC 301 FC 302
130B0524 * n n n n
* To be used only for IP 20/NEMA type 1 units up to 7.5 kW

Weather shield for outdoor


installations
Designed to be mounted above the VLT® drive
to protect from direct sun, snow and falling
debris.

Ordering number
Frame A4, A5, B1, B2.................................. 130B4598
Frame C1, C2...................................................130B4597

Danfoss VLT Drives · DKDD.PB.400.A4.02 11


The vision behind VLT®
Danfoss is a market leader in the development and manufacture
of frequency converters – serving new customers daily.

Dedicated to drives Trust the world experts


Environmental Danfoss VLT Drives is a global leader To ensure the consistent high standard
responsibility in the area of drive engineering of quality of our products, Danfoss
and manufacture. In 1968 Danfoss VLT Drives controls and monitors
Danfoss VLT® products introduced the world’s first mass- every important product element.
– considering people and the produced frequency converters for The group has its own research and
environment three-phase motors, and since then has software development department as
All production sites for VLT® frequency well as modern production facilities
converters certified to ISO 14001 and
specialised in drive solutions. Today,
ISO 9001. VLT® stands for reliable technology, for hardware, power modules, printed
Danfoss’ activities take employees, innovation and expertise for drive circuit boards and accessories.
jobs and the environment into solutions within many different
consideration. Production processes branches of industry. VLT® frequency converters are used
produce minimum noise, emissions in diverse applications worldwide.
and other environmental impacts. In
addition, Danfoss seeks to protect the The experts of Danfoss VLT Drives
environment when disposing of waste Innovative and intelligent support customers with extensive
and end-of-life products. frequency converters specialised knowledge relating to
Danfoss VLT Drives, headquartered specific applications. Comprehensive
UN Global Compact advice and a fast service ensure an
Danfoss has confirmed its
in Graasten, Denmark, employs 2500
commitment to social responsibility staff for the development, production, optimal solution with high reliability
by signing the UN Global Compact. consulting, sales and maintenance of and availability.
Our subsidiaries are aware of their Danfoss drive solutions in over 100
responsibility with respect to local countries. A project is only complete when our
conditions and practices. customers are fully satisfied with the
Energy savings through VLT® The modular frequency converters drive solution.
The energy saved in the annual are manufactured according to
production of VLT® frequency customer requirements and supplied
converters is as much as that fully assembled. This ensures that every
generated by a large power station
each year. Improved process control
VLT® is a state-of-the art device when
optimises product quality and reduces delivered.
waste and wear on the production
lines.

Danfoss VLT Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80, www.danfoss.com/drives, E-mail: info@danfoss.com