Professional Documents
Culture Documents
Operating Instructions: Multiturn Actuator Pneumatic - Mechanical
Operating Instructions: Multiturn Actuator Pneumatic - Mechanical
Multiturn actuator
pneumatic - mechanical
for butterfly valve and ball valve
KIESELMANN GmbH
25.3.13
Paul-Kieselmann-Str.4-10
D - 75438 Knittlingen
1
1. List of contents
5. Function ........................................................................................................................ 3
5.1 Functional description ........................................................................................................3
6. Installation informations................................................................................................. 4
6.1 Installation instructions.......................................................................................................4
7. Maintenance.................................................................................................................. 4
7.1 Maintenance ......................................................................................................................4
1
2. Information for your safety
We are pleased that you have decided for a high-class KIESELMANN product. With correct application
and adequate maintenance, our products provide long time and reliable operation.
Before installation and initiation, please carefully read this instruction manual and the security advices
contained in it. This guarantees reliable and safe operation of this product and your plant respectively.
Please note that an incorrect application of the process components may lead to great material damages
and personal injury.
In case of damages caused by non observance of this instruction manual, incorrect initiation,
handling or external interference, guarantee and warranty will lapse!
Our products are produced, mounted and tested with high diligence. However, if there is still a reason
for complaint, we will naturally try to give you entire satisfaction within the scope of our warranty. We will
be at your disposal also after expiration of the warranty. In addition, you will also find all necessary instruc-
tions and spare part data for maintenance in this instruction manual. If you don't want to carry out the main-
tenance by yourself, our KIESELMANN service team will naturally be at your disposal.
Hints are available in the chapter "safety instructions" or directly before the respective operation instruction.
The hints are highlighted with a danger symbol and a signal word. Texts beside these symbols have to
be read and adhered to by all means. Please continue with the text and with the handling at the valve only
afterwards.
Safety informations
ak 12.1.11
2
4. Safety instructions
ATTENTION
• To avoid danger and damage, the fitting must be used in accordance with the safety instructions
and technical data contained in the operating instructions.
DANGER
• Danger of injury by spring tension!
The drive is maintenance-free. Do not open it.
NOTE
All data are in line with the current state of development. Subject to change as a result of technical
progress.
5. Function
NOTE
• To make sure that the rotary movement really stops at 0°-
90° or 90°-0°, make sure to bleed the compressed air port
of the rotary drive not being used.
• In order to avoid air leakages, only use an elbow-type
screw-in connexion respectively a straight screw-in con-
nexion with sealing by an o-ring to the end face.
3
6. Installation informations
NOTE
You may have to restrict the pressure of the outlet air to avoid line shocks.
7. Maintenance
7.1 Maintenance
KIESELMANN actuators are free of maintenance and can‘t be dismantled. The manufacturer guarantees
a running time of five years or 50.000 strokes.
NOTE
To prevent leaks, the thread needs to be sealed with
a gasket strip when installing the proximity switches.
4
9. Technical Data
Model: Multiturn, pneumatic - mechanical
Angle of rotation 90°
enclosed type
Kind of actuation: air / air
air / spring
Valve size: Actuator 90 / 75
Actuator 90 / 100
Actuator 90 / 125
Temperature range: Ambient temperature: +4°C to +60°C
Pneum. connection: G 1/8
Control air: Control air pressure: Quality of control air:
• 5,5 - 8,0 bar • ISO 8573-1 : 2001 quality class 3
Material: Stainless steel: 1.4301 / AISI304
Surfaces: Ra < 1,5 - 2,5µm e-polished
Seals: NBR
10. Dimensions
Actuator
90 / 75 90 / 100 90 / 125
d 76 104 129
L1 56 56 78
L2 12 12 20
L3 14 14 16
M 8 8 8
10 10 14
5
11. Torque characteristic
90/75 air/spring
35
30
25
20
15
Torque (Nm)
10
5
90/75 pneu-mech
0
0 10 20 30 40 50 60 70 80 90
Angle of rotation (Grad °)
6 bar 80
85
70
5 bar
70 60
60 50
50 4 bar 40
Torque (Nm)
Torque (Nm)
3 bar 30
35
20
90/100 pneum. 90/100 pneu-mech
20 10
0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90
Angle of rotation (Grad °) Angle of rotation (Grad °)
200 130
6 bar
180 120
5 bar 110
150
100
4 bar
120 90
Torque (Nm)
Torque (Nm)
3 bar 80
90
70
90/125 pneum. 90/125 pneu-mech
60 60
0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90
Angle of rotation (Grad °) Angle of rotation (Grad °)
6
12. Spare parts list
12.1 Actuator
Actuator Type Article No. Material
7
Declaration of incorporation
Translation of the original
The manufacturer hereby states that the above product is considered as an incomplete machine in the sense defined
in the Directive 2006/42/EC on Machinery. The above product is exclusively intended to be installed into a machine or
an incomplete machine. The said product does not yet conform to all the relevant requirements defined in the Directive
on Machinery referred to above for this reason.
The specific technical documents listed in Appendix VII, Part B, have been prepared. The Authorized Agent empowered
to compile technical documents may submit the relevant documents if such a request has been properly justified.
Commissioning of an incomplete machine may only be carried out if it has been determined that the respective machine
into which the incomplete machine is to be installed conforms to the regulations set out in the Directive on Machinery
referred to above.
The above product conforms to the requirements of the directives and harmonized standards specified below: