JANSEN BRANDSCHUTZ

Textile-flexible systems
Jansen textile-flexible systems stand out due to

• invisible fire and smoke protection because of a small recess gap.

• its low demand on space.

• its low weight.

Smoke guard

Smoke protection conclusion

Fire protection curtain


JANSEN BRANDSCHUTZ

Textile-flexible systems

• Smoke guards according to DIN EN 12101-1.


• Smoke protection conclusions according
to DIN 18095-3/Sm DIN 18095-3/
Sm according to DIN EN 1634-3.
• Fire protection curtains according to DIN EN 1634-1.

System: Function: Options:


Textile-flexible systems consist of In open condition the winding • RAL lacquer coat
textile fabrics which have been ap- shaft is located in a zinc-coated to choice (casing)
proved by building control. Corre- sheet steel casing above or in the • stainless steel
sponding to the classification for aperture to be closed. The winding • battery buffering
sealing-off of fire and smoke, glass shaft is kept in an open position • fire detection /
filament fabrics are used, partially by means of a magnetic clamp. internal locking device
with silicon or polyurethane lami- The system is closed speed-cont-
nation. rolled through an end-rail via dead Approved/
Due to the low weight and small weight following the principle of verified according to:
casing and guide rail dimensions “Gravity Fail Save” at appr. 15 cm/s. Smoke guards:
these systems are especially indica- D60/ DIN EN 12101-1
ted for open room designs or refit- Control & drive: Smoke protection conlusions:
ting. For the activation of the drive with RS/ DIN 18095-3, respectively
internal locking device a micro- Sm/DIN EN 1634-3
Guide rail: processor controlled internal lo- Fire protection curtains:
The hanging is guided in laterally cking system is implemented for ---/E30 – 180, respectively EW30 –
mounted profiles. the automatic textile-flexible sys- 60 according to DIN EN 1634-1
tems. Due to battery buffering the
end-rail will be held in its current
position for at least 4 hours in case
of a power outage.
Smoke Smoke protection the rescue of persons for a span of
guards: conclusions: appr. ten minutes without respira-
In combination with smoke and They serve to keep application tory protection.
heat extractor systems they serve units and especially escape and
to create a smoke-free layer above rescue routes free of smoke. Fire protection
floor level, improving escape and Smoke protection conclusions in curtains:
rescue of people and animals closed condition are supposed In a built-in condition their pur-
as well as the protection of the to hamper the entry of smoke in pose is to prevent the entrance of
building. such a way, that in case of a fire fire.
the area beyond can be used for
Maintenance and Service
The name Jansen does not only Inspection & work routines as well as possible
stand for innovative products and Maintenance faults are stated.
varied special solutions in the area All-around one-stop service means For fire-protection closures with
of fire protection, but also offers that Jansen not only takes care of lock systems, the operator is ob-
their customers comprehensive the compulsory inspection for door liged to periodical monitoring
and individual service – not only for systems (according to inspection through qualified persons accor-
their own door systems but also for regulations of the respective fede- ding to the guidelines for lock
those of other manufacturers. Our ral state and the rule of the profes- systems, published by the German
intensive on-site customer support sional association) but also offers Institute for Constructional Engi-
is carried out by skilled professio- additionally the maintenance of neering in Berlin. Furthermore the
nal personnel. Hereby we can gu- the door systems on request. Cus- performance of fire-protection
arantee the highest level of safety tomers thus not only save money door systems with lock systems has
for your door systems. but also a considerable amount of to be checked by the operator.
time.
Assembly The difference between main- Repair
Apart from the delivery of door tenance and inspection is that In order to rectify any problems as
systems Jansen naturally also for maintenance additional quickly as possible the competent
carries out the assembly and ins- work routines according to the staff will be pleased to be of ser-
tallation of the products. Due to manufacturer’s guidelines are car- vice to you any time. Just contact
our own skilled assembly operators ried through for the preservation Jansen. They will help you quickly
Jansen guarantees a smooth imple- of performance properties. and without long waiting periods.
mentation from the actual installa- After completion of the respec-
tion via the electronical installation tive maintenance or inspection the
up to the acceptance inspection. customer receives an inspection
record in which all implemented

Jansen Brandschutz GmbH & Co. KG


Am Wattberg 51
26903 Surwold
Phone: +49 (0) 49 65 / 89 88 - 0
Fax: +49 (0) 49 65 / 89 88 - 88
info@jansentore.com
www.jansentore.com