Technical Data

CIKOpoxy CF
Solvent free, epoxy resin based Injection crack repair system

Description Physical Properties


CIKOpoxy CF is a solvent free two component Criteria CIKOpoxy CF
epoxy resin based injecting and filling system,
recommended for filling and sealing static cracks Form 2 component system
in concrete and masonry. It provides excellent
adhesion to substrates like concrete and act as Colour Pale yellow
the monolithic part of the element.
Mixing Ratio Pre-packed
Properties Solids % 100

Finish Glossy
 Two component epoxy based system.
0
 Provides excellent adhesion to many Pot Life @ 25 C 60-90 min
substrates. Surface Dry 3-4 hours
 Permanent crack filler for static cracks.
Tack-Free App. 8 hours
 Suitable for structural crack repairs.
Compressive Strength 2
 Non-shrink and suitable for hot climates. ≥85 N/mm
BS 6319
 Chemical resistant. Flexural Strength 2
≥40 N/mm
BS 6319
Tensile Strength ASTM 2
≥20 N/mm
D638
Application area
 For repairing static structural Coverage/Yield
CIKOpoxy CF will provide a yield of 4.0 litres per pack.
concrete cracks having crack size
Note: Exact coverage depends on the length, width and
between 0.1 mm and 10.0 mm.
depth of the crack.
 Vertical and overhead applications
Application instructions
 High compressive and flexural Surface preparation
The cracks must be cleaned to remove contamination,
strengths exceeding that of the paint, loosely held materials, algae etc. Oil or grease
concrete structural element. traces if present must be removed by steam cleaning or
by using proper detergents. The surface can be cleaned
 Well suited for pressure injection for using high pressure water jetting or sand blasting. Finally
smaller cracks blow the cracks using compressed air and allow drying.

Mixing
The base [Part-A] and hardener [Part-B] components of
Applicable standards CIKOpoxy CF should be mixed thoroughly using a heavy
CIKOpoxy CF complies with QCS requirements.

1
duty slow speed drill-paddle assembly for three Storage
minutes to five minutes and ensure a CIKOpoxy CF should be stored under cool enclosed
0
homogenous mix. shaded at temperatures between 10 and 35 C

Horizontal Cracks Precautions


Application method  CIKOpoxy CF should not be applied at
After doing the necessary surface preparation 0
temperatures below 10 C.
sealing the exposed cracks and fixing the  Assure that the cracks to be injected are static
nipples using CIKOpoxy Putty as per its and dry.
respective technical data sheet, inject the mixed
CIKOPoxy CF into the cracks through surface
nipples using a suitable injection equipment or Health & safety
syringe. The injection points must be equidistant CIKOpoxy CF should not come in contact with eyes or
and should not be more than 20 centimetres be swallowed. Ensure adequate ventilation and avoid
apart. The cracks must be filled from the top inhalation of vapours. Applicator should wear
surface of the joint and allow to percolate for appropriate clothes, gloves and goggles. Use of barrier
some time. The injection procedure must be cream is recommended to provide additional skin
carried out to fill the crack till the end of material protection. If comes in contact with eyes, flush with
percolation and allow drying for a period of 24 plenty of fresh water and seek medical advice.
hours.
Surface finishing Refer Material Safety Data Sheet for further details.
Cut open the filled cracks in “V” shape to a depth
of maximum 10mm and clean the area to be free Technical Support
from dust and loose particles. Fill the cut opened For any technical support, do not hesitate to contact
crack surface using CIKOPoxy Putty leveled to CIKO team at any time as CIKO offers on and off site
the concrete surface.
services to end users, specifier and contractors.
Vertical and Overhead cracks
Sealing cracks with packers
More from CIKO Middle East
Identify the nipple positions (number of nipples
depends on width of the cracks and size of the A wide range of construction chemical products are
structural element). Fix nipples using CIKOpoxy manufactured by CIKO Middle East which includes:
putty and simultaneously fill the cracks (surface  Concrete admixtures and additives
only) all along the length. Allow the material to  Waterproofing and damp proof coatings
dry at least 12 hours before proceeding with  Surface treatments
injection.  Flooring and toppings
Application method
 Grouts and anchors
Having made the necessary arrangements, the  Tile adhesives and grout
mixed CIKOPoxy CF must be injected into the  Adhesives and bonding agent
cracks through nipple using suitable injection  Concrete repair materials
equipment. When the excess material starts  Protective coating
flowing out from adjacent nipples, immediately  Joint Sealants
block the nipple and shift injection point to the
 Moulding compounds
next nipple. Complete the injection procedure in
one operation and allow for 24 hours drying.
Remove packer and repair the holes using
CIKOpoxy putty.

Packaging
CIKOpoxy CF is available in 4.0 litre kits
consisting of Part-A & B.

Shelf Life
CIKOpoxy CF has a shelf life of 12 months if
stored in accordance with CIKO instructions.