AMENDMENT

TO
STANDARD TECHNICAL SPECIFICATION FOR
RETROFIT OF WET LIMESTONE BASED
FLUE GAS DESULPHURISATION (FGD) SYSTEM
IN A TYPICAL 2 x 500 MW THERMAL POWER PLANT

CENTRAL ELECTRICITY AUTHORITY


NEW DELHI

October, 2018
Amendment to Standard Technical Specification for Retrofit of Wet Limestone Based Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant

Amendment to “Standard Technical Specification for Retrofit of Wet Limestone Based Flue Gas Desulphurisation (FGD)
System in a Typical 2x500 MW Thermal Power Plant.”
(Issued by CEA in December 2017)

Sl. Specification Description To be read as


No. clause

Section-1, General Notes, Applicability and Project Specific Information


1. Clause No. 1.1 (iii) Partial treatment of flue gas: Partial treatment of flue gas and use of existing
chimney:
The compliance of emission norms of 100
mg/Nm3& 200 mg/Nm3, the required SO2 removal The compliance of emission norms of 100
efficiency of FGD system to be installed shall be in mg/Nm3 & 200 mg/Nm3, the required SO2
the range 90- 95%. For compliance of emission removal efficiency of FGD system to be installed
norms of 600 mg/Nm3, the required SO2 removal shall be in the range 90- 95%. For compliance of
efficiency of FGD system needs to be in the range emission norms of 600 mg/Nm3, the required
60- 70%. The partial bypass of raw flue gas helps SO2 removal efficiency of FGD system needs to
in increasing the temperature of the mixed flue gas be in the range 60- 70%. The partial bypass of
and increases the buoyancy of exit flue gas raw flue gas helps in increasing the temperature
leading to its wider dispersion. It also reduces the of the mixed flue gas and increases the
problem of moisture condensation in chimney. In buoyancy of exit flue gas leading to its wider
this specification, partial bypass of raw flue gas dispersion. It also reduces the problem of
has not been envisaged considering complexity of moisture condensation in chimney. However,
damper control scheme and operational issues provision of control dampers is required for part
involved. Instead, 100% treatment of the flue gas bypass of raw flue gas which involve complex
has been considered with required level of SO 2 control scheme and there are operational issues
emission in treated gas to be achieved by the FGD also. Alternatively, 100% treatment of the flue
supplier as per his optimization for height of the gas can be considered with required level of SO2
absorber, limestone slurry feed etc. emission in treated gas to be achieved by the
FGD supplier as per his optimization for height

1
Amendment to Standard Technical Specification for Retrofit of Wet Limestone Based Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant

However, in case for applicable emission norms of of the absorber, limestone slurry feed etc.
600 mg/Nm3, the purchaser intends to adopt FGD
In case of thermal power plants with permissible
scheme with partial bypass with/ without GGH as
SO2 emission norm of 600 mg/Nm3 and FGD
per his own assessment, the standard
plant retrofit envisaged with GGH, the
specification shall need to be modified for
temperature of mixed flue gas to be discharged
incorporation of relevant changes as required to
through chimney shall be considerably higher
this effect.
than saturation temperature of moisture in it.
Further, if SO3 concentration in the flue gas is
low, the corrosion potential on chimney flue(s)
shall be considerably reduced. In such case, the
provision of new wet chimney may not be
considered essential and existing chimney
(without anti- corrosive lining) can be used for
discharge of the treated flue gases.

The aspect of partial bypass of raw flue gas has


not been considered in this specification
(reference SO2 emission limit being 200
mg/Nm3) and a new wet chimney has been
envisaged for discharge of treated flue gases.
However, in case of plant with applicable SO2
emission norms of 600 mg/Nm3 and SO3 level in
flue gas being low (say below 10 ppm), the
purchaser, based on his own assessment, can
adopt FGD scheme with GGH & partial bypass
and use existing chimney without going for lining
etc. The standard specification shall need to be
modified for incorporation of relevant changes
as required to this effect.

2
Amendment to Standard Technical Specification for Retrofit of Wet Limestone Based Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant

2. Clause No. 1.1 (iv) Gas to gas heat exchanger (GGH): Gas to gas heat exchanger (GGH):

The use of gas to gas heat exchanger (GGH) in The use of gas to gas heat exchanger (GGH) in
FGD system has got both merits and demerits. The FGD system has got both merits and demerits.
GGH has advantage of reducing the temperature The GGH has advantage of reducing the
of inlet raw flue gas to the absorber which reduces temperature of inlet raw flue gas to the absorber
potential of damage to scrubber internals in case which reduces potential of damage to scrubber
of flue gas excursion and mal- operation etc. internals in case of flue gas excursion and mal-
Reheating of treated flue gas helps in preventing operation etc. Reheating of treated flue gas
stack condensation and also increases the helps in preventing stack condensation (due to
buoyancy of flue gas exiting from the chimney superheating of saturated moisture) and also
resulting in dispersion of pollutants over a wider increases the buoyancy of flue gas exiting from
area and consequently reduced ground level the chimney resulting in dispersion of pollutants
concentration of pollutants. However, GGH over a wider area and consequently reduced
requires additional space, results in additional ground level concentration of pollutants.
pressure drop, leakage issues apart from adding However, GGH requires additional space,
to the cost. Even with GGH, chimney flue(s) may results in additional pressure drop, leakage
require additional protection by way of lining or issues apart from adding to the cost. The
resistive painting. The standard specification has standard specification has been drawn without
been drawn without GGH. use of GGH.
However, in case the purchaser intends to provide
for GGH in the FGD system as per his own However, in case the purchaser intends to
assessment, the standard specification shall need provide for GGH in the FGD system as per his
to be modified for incorporation of relevant own assessment, the standard specification
changes as required to this effect. shall need to be modified for incorporation of
relevant changes as required to this effect.

3
Amendment to Standard Technical Specification for Retrofit of Wet Limestone Based Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant

3. Clause No. 1.1 (v) (b) New wet chimney & suggested height: New wet chimney & suggested height:

For a thermal power plant fitted with FGD, the For a thermal power plant fitted with FGD, the
required height of the chimney is governed by required height of the chimney is governed by
quantum of SO2 being emitted from the chimney. quantum of SO2 being emitted from the chimney.
Vide draft notification dated 16.10.2017, Vide gazette notification G.S.R. 593 (E) dated
MoEF&CC has specified stack height for thermal 28.06.2018, MoEF&CC has specified stack
power plants with FGD installation for public height for thermal power plants with FGD
comments. The stack height required to be installation for public comments. The stack
provided is indicated as below: height required to be provided is indicated as
below:
Power generation capacity: Stack height:
Power generation capacity: Stack height:
- 100 MW and above H=6.902(Qx0.277)0.555
or - 100 MW and above H=6.902(Qx0.277)0.555
100 m whichever is more
or
100 m whichever is more
- Less than 100MW H=6.902(Qx0.277)0.555
or
- Less than 100MW H=6.902(Qx0.277)0.555
30 m whichever is more
or
30 m whichever is more
Q = Emission rate of SO2 in kg/hr
H = Physical stack height in meter.
Q = Emission rate of SO2 in kg/hr (total of all
unit’s connected to the stack)
H = Physical stack height in meter.
Final stipulation on requirement of chimney height
is yet to be notified.
Considering that permissible levels of SO2
Considering that permissible levels of SO2 emission varies as per unit size/ vintage and that
emission varies as per unit size/ vintage and that number of units connected to a chimney vary on
number of units connected to a chimney vary on case to case basis, the calculated height of the
case to case basis, the calculated height of the chimney does not follow a gradual pattern w.r.t.
chimney does not follow a gradual pattern w.r.t. unit size. Further, chimney height should not be
unit size. Further, chimney height should not be less than boiler height. Based on overall
less than boiler height. Based on overall consideration of various factors involved, the
consideration of various factors involved, the suggested appropriate height of the chimney for

4
Amendment to Standard Technical Specification for Retrofit of Wet Limestone Based Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant

suggested appropriate height of the chimney for different size of units installed up to 31.12.2016
different size of units installed up to 31.12.2016 is is as below:
as below:
No. of units connected to
No. of units connected to the chimney
the chimney
1 2
Unit size
1 2
Unit size Suggested height of wet
Suggested height of wet chimney (m)*
chimney (m)*
< 250 MW 100 125
< 250 MW 100 125
≥ 250 MW and < 500 MW 125 150
≥ 250 MW and < 500 MW 125 150
≥ 500 MW 150 150
≥ 500 MW 150 150

The suggested appropriate height of the chimney for different The suggested appropriate height of the chimney for
size of units installed from 1.1.2017 is as below: different size of units installed from 1.1.2017 is as below:

No. of units connected to No. of units connected to


the chimney the chimney

1 2 1 2
Unit size Unit size
Suggested height of wet Suggested height of wet
chimney (m)* chimney (m)*

< 250 MW 100 100 < 250 MW 100 100

≥ 250 MW and < 500 MW 125 125 ≥ 250 MW and < 500 MW 125 125

≥ 500 MW 150 150 ≥ 500 MW 150 150

*purchaser is required to check & review for *purchaser is required to check & review for
adequacy of indicated chimney height as per final upward revision of indicated chimney height, if
notification of MoEF&CC and accordingly any, as per applicable calculations and
incorporate in the standard specification. accordingly incorporate same in the standard
specification.

5
Amendment to Standard Technical Specification for Retrofit of Wet Limestone Based Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant

4. Clause No. 1.1 (xiv) Absorber lining material: Absorber lining material:
The clause 4.3.1 (vii) specifies the absorber The clause 4.3.1 (vii) specifies the absorber
tower, oxidation tank, absorber internals & other tower, oxidation tank, absorber internals & other
parts, absorber outlet duct to be provided with parts, absorber outlet duct to be provided with
minimum 2 mm thick lining/ cladding of SS 317 minimum 2 mm thick lining/ cladding of SS 317
LMN / Alloy 31/ Hastelloy C22/ C 59/ C276 or LMN / Alloy 31/ Hastelloy C22/ C 59/ C276 or
equivalent. The purchaser, as per his own equivalent. The purchaser, as per his own
assessment and considerations, may decide to go assessment and considerations, may decide to
in for other applicable materials also such as go in for other applicable materials also such as
rubber lining (minimum 4 mm thick), flake glass rubber lining (minimum 4 mm thick), flake glass
lining (minimum 3 mm thick). In such case, lining (minimum 3 mm thick), ceramic tiles,
necessary changes shall need to be incorporated absorber in GRP material. In such case,
in the relevant sections of the standard necessary changes shall need to be
specification. incorporated in the relevant sections of the
standard specification.
5. Clause No. 1.1 (xv) Chimney lining material: Chimney lining material:
The clause 4.20 (i) specifies the chimney flue liner The clause 4.20 (i) specifies the chimney flue
cladding to be made of 2 mm thick Titanium (Grade liner cladding to be made of 2 mm thick Titanium
2 as per ASME SB265) or C-276 alloy over 8 mm (Grade 2 as per ASME SB265) or C-276 alloy
thick (minimum) mild steel base metal of flue liner. over 8 mm thick (minimum) mild steel base
The purchaser, as per his own assessment and metal of flue liner. The purchaser, as per his own
considerations, may decide to go in for other assessment and considerations, may decide to
applicable materials also such as C22 alloy, go in for other applicable materials also such as
Borosilicate Block lining. In such case, necessary C22 alloy, Borosilicate Block lining or complete
changes shall need to be incorporated in the flue(s) of fire retardant GRP/ FRP. In such case,
relevant sections of the standard specification. necessary changes shall need to be
incorporated in the relevant sections of the
standard specification.

6
Amendment to Standard Technical Specification for Retrofit of Wet Limestone Based Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant

Section-3, System Description and Scope


6. Clause No. 3.2.1 Each absorber tower shall be provided with Each absorber tower shall be provided with
(iii) (b) multiple limestone slurry spray levels (minimum 4 adequate number of multiple limestone slurry
nos.) or a single spray level as per bidder or his spray levels or a single spray level as per bidder
collaborator’s proven and standard practice. In or his collaborator’s proven and standard
case of multiple spray level design absorber, each practice. In case of multiple spray level design
spraying level shall be provided with one individual absorber, each spraying level shall be provided
limestone slurry recirculation pump. One spray with one individual limestone slurry recirculation
level shall be kept as spare to meet 100% pump. One spray level shall be kept as spare to
availability of the FGD plant in case of failure of any meet 100% availability of the FGD plant in case
one slurry recirculation pump or one spray level. In of failure of any one slurry recirculation pump or
case of single spray level design absorber, one spray level. In case of single spray level
multiple numbers of identical slurry recirculation design absorber, multiple numbers of identical
pumps shall be provided with one number slurry recirculation pumps shall be provided with
recirculation pump kept as standby pump. In case one number recirculation pump kept as standby
of bubbling type absorber with flue gas bubbling pump. In case of bubbling type absorber with
through the limestone slurry, gas distribution flue gas bubbling through the limestone slurry,
system to the slurry and 3x50% gas cooling water gas distribution system to the slurry and 3x50%
pumps shall be provided to cool and saturate the or 2x100% gas cooling water pumps shall be
incoming hot flue gas. provided as per requirement and bidder’s
standard & proven practice.
7. Clause No. 3.2.1 Emergency quenching system including dedicated Emergency quenching system including
(iii) (e) water tank of adequate capacity, 2 x 100% dedicated water tank of adequate capacity, 2 x
capacity pumps and associated piping to cool the 100% capacity pumps and associated piping to
flue gas inlet to the absorber in case of sudden rise cool the flue gas inlet to the absorber in case of
in flue gas temperature. sudden rise in flue gas temperature.
Alternatively, the bidder may offer gravity system
for supply of emergency quenching water as per
his proven and standard practice.

7
Amendment to Standard Technical Specification for Retrofit of Wet Limestone Based Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant

Section-4, Mechanical Works


8. Clause No. 4.3.1 The absorber slurry tank shall be designed for 6 The absorber slurry tank shall have adequate
(viii) minutes retention based on the design absorber retention volume as per standard and proven
slurry flow rate. practice of the bidder and same shall be subject
to approval of the purchaser during detail
engineering.

The above amendments are based on resolution of the issues raised/ identified on CEA’s Standard Technical Specification for Retrofit
of Wet Limestone Based Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant (issued in December,
2017), as per discussions held on 13.8.2018 in the meeting of the committee constituted for preparation of the subject specification.
These amendments shall be read in conjunction with CEA’s Standard Technical Specification for Retrofit of Wet Limestone Based
Flue Gas Desulphurisation (FGD) System in a Typical 2x500 MW Thermal Power Plant (issued in December, 2017).
******