Professional Documents
Culture Documents
Taboe Sani 2. Taboe 3. Taboe Freestanding
Taboe Sani 2. Taboe 3. Taboe Freestanding
2 3
1. Taboe Sani
2. Taboe
3. Taboe Freestanding
72
1
74
Taboe Sani
75
Taboe Sani
Dimensions Connections Range
TSSW_Taboe Sani Single Wall Code: 1° number = flow Single
2° number = return
4 5
7.2 11.0
76
TSDW_Taboe Sani Double Wall
1 8
7.2 11.0
182
Standard connection
Code 18
Connection 18 or 81
121
G1/2"
To the floor:
50 50
7.2
10
To the wall:
Double
movable wall fixing
H 7.2
10
182
With electric element
121
50 50
Mixed
Ordering code: standard code 18.
Order an electric element and T-piece.
- Fit the T-piece together with the electric hea-
ting element for connection to the central
heating wet system.
- Never isolate the radiator from the expan-
sion system, in other words never cut off the
return of the radiator.
m
2.5 c
m
10 c
7.2
cm
Outputs
H L 050
Standard delivery
121 75/65/20 590 - central connection 18 underneath 77
90/70/20 759 - wall fixing set
s - chrome-plated air vent and drain cock
Taboe Sani
o H
Standard colours: L
182 75/65/20 887 - white (333) RAL 9016 satin
90/70/20 1143 - white (301) RAL 9010 satin
st. colour € 592,40 - sandblast grey metallic 001
other € 681,30
H L 050
Standard delivery
121 75/65/20 800 - central connection 18 underneath
90/70/20 1018 - wall fixing set
s - chrome-plated air vent and drain cock
o
Standard colours: H
- white (333) RAL 9016 satin L
182 75/65/20 1206
90/70/20 1545 - white (301) RAL 9010 satin
s - sandblast grey metallic 001
o
H L 050
Standard delivery
121 75/65/20 459 - brushed stainless steel
90/70/20 581 - central connection 18 underneath
b - wall fixing set H
L
- chrome-plated air vent and drain cock
182 75/65/20 627
90/70/20 799
b
L
78 Adaptor
T-piece
1.45
- Insulation Class 1 Use PFTE
or flax
0.9
G 1/2"
CODE WATTS L
9096.510 600 47
9096.520 900 68
1. Taboe
2. Taboe Freestanding
80
Taboe
81
Taboe
Dimensions Connections Range
TABW_Taboe Wall TABW_Taboe Wall
- for central heating
- 100% electric
- mixed
1 8
82
11.5 10
ø 2.5 Standard connection
Code 18
Connection 18 or 81
ø 1.5
180
To the floor:
125
44.4
H
7.2
10
8.4
To the wall:
44.4
TABF_Taboe Free-standing
8.5 7.2
10
44.4 10
180
3°
125
Mixed
Ordering code: standard code 18.
Order an electric element and T-piece.
- Fit the T-piece together with the electric hea-
ting element for connection to the central
heating wet system.
- Never isolate the radiator from the expan-
sion system, in other words never cut off the
return of the radiator.
38 39
m
2.5 c
m
10 c
7.2
cm
Outputs
H L 044
Standard delivery
125 75/65/20 432 - 2 wall fixing brackets in the same colour 83
90/70/20 546 as the radiator
- invisible inside sockets 1/2” at the
Taboe
H
bottom end of the collector tubes
180 75/65/20 629 - air venting via the round balls at the top
90/70/20 792 end of the collector tubes
44
44
44