Inspection & Testing Requirements Scope:: Test and Inspection Per

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

INSPECTION & TESTING REQUIREMENTS REVISION: 06/29/2011 CODE NUMBER: PAGE:

SAUDI ARAMCO FORM-175 REPLACES: 01/24/2006 IR325516 1 of 2


SCOPE: COMBUSTION GAS TURBINE PACKAGE: ATMOSPHERIC TANKS; for auxiliary system

TEST AND INSPECTION PER: Manufacturer Standard and Specifications as noted below.

(1) VISUAL INSPECTION WITNESSING BY INSPECTOR (Note 1)


(2) CERTIFICATES / RECORDS TO BE CHECKED BY INSPECTOR
(3) CERTIFICATES / DATA TO BE PROVIDED BY VENDOR / SUPPLIER / MANUFACTURER
0010
0010
*** X
Pre-Fabrication/Production Requirements
Material Test Reports
Specification Details / Notes:
All materials shall be clearly identified and provided with mill
test certificates.

0020 X NDT Personnel and Procedures Verify valid certification of personnel and procedures.

0030 X Procedure Qualification Records & Welding Procedure Per any of the following: BSI /ASME /JIS /DIN /EN.
Specification (PQR and WPS)

0040 X Welder Qualification Records Per any of the following: BSI /ASME /JIS /DIN /EN.

0050 X X Inspector qualification records Verify assigned coating inspector qualification to be per NACE
or equivalent.

0060 X Vendor’s assigned coating Inspector Verify Vendor’s assigned coating inspector is a current NACE
certified.

0020
0010
*** X
In process inspection & test requirement
Nondestructive Testing Requirements (NDT):
Specification Details / Notes:
Per The applicable international standard identified above.
Liquid Penetrant Testing includes shell to bottom inside fillet welds. All welds and
all structural attachment welds.

0020 X Nondestructive Testing Requirements (NDT): Welding after painting is not permitted.
Visual Weld Inspection

0030 X Internal/Immersion Coating (If applicable) If required shall be per SSPC-SP1.


Surface Preparation:
I. Pre-Blast Check;

0040 X X Internal/Immersion Coating (If applicable)


Surface Preparation:
I. Pre-Blast Check;

0050 X Internal/Immersion Coating (If applicable) Removal of Rough Welds, cut-offs, weld spatter, and arc
Surface Preparation: strikes.
I. Pre-Blast Check;

0060 X X Internal/Immersion Coating (If applicable) Free of oil, moisture and contamination. As a minimum, the
Surface Preparation: inspector shall check and approve air quality at the start,
II. Equipment; mid-point of each 8 hour shift.

0070 X Internal/Immersion Coating (If applicable)


Surface Preparation:
II. Equipment;

0080 X Internal/Immersion Coating (If applicable)


Surface Preparation:
II. Equipment;

IR325516 Continued...
INSPECTION & TESTING REQUIREMENTS REVISION: 06/29/2011 CODE NUMBER: PAGE:
SAUDI ARAMCO FORM-175 REPLACES: 01/24/2006 IR325516 2 of 2
(1) VISUAL INSPECTION WITNESSING BY INSPECTOR (Note 1)
(2) CERTIFICATES / RECORDS TO BE CHECKED BY INSPECTOR
(3) CERTIFICATES / DATA TO BE PROVIDED BY VENDOR / SUPPLIER / MANUFACTURER
0090 X Internal/Immersion Coating (If applicable)
Surface Preparation:
II. Equipment;

0100 X Internal/Immersion Coating (If applicable)


Surface Preparation:
III. Cleaning; Spent Abrasive Removal

0110 X Internal/Immersion Coating (If applicable)


Surface Preparation:
IV. Primer on Abrasive Cleaned Surfaces

0120 X X Paint & Coatings Application:


a) Atmospheric Conditions & Substrate Temperature

0130 X Paint & Coatings Application:


b) Substrate Surface Inspection

0140 X X Paint & Coatings Application: Dry Film to be checked in accordance with SSPC-PA2.
c) Wet & Dry Film Coating Thickness’ Readings

0150 X Paint certification Manufacturer standard.

0030
0010
*** X
Final inspection & test requirements
"Internal/Immersion" Coatings (If applicable):
Specification Details / Notes:

a) Paint Thickness Near (2m) Anode Connections

0020 X X "Internal/Immersion" Coatings (If applicable):


b) Holiday Testing

0030 X "Internal/Immersion" Coatings (If applicable):


c) Repair Procedure for Immersion Coatings

0040 X X Quality control tests shall be recorded.

0050 X Paint Certification (external) Manufacturer standard.

0060 X Visual Inspection of Finished Coatings

0040 *** Additional/Supplemental Requirements Specification Details / Notes:

Notes:
(1) May only be waived by the responsible Saudi Aramco, ASC, and AOC Inspection Offices.
(2) See form SA175 - 000003 for instructions on using this form.

End of IR325516

You might also like