Vodafone Standard Procedure For Microwave Swap Site - V1
Vodafone Standard Procedure For Microwave Swap Site - V1
Swap Site
Huawei Confidential
Standard Procedure For Microwave Swap Site
Revision Declaration
This document is prepared and explained by the Site Business Dept of Global Technical Service D
Specifications or documents related to this document:
Related international specifications or document consistency:
Specifications or documents that are replaced or expire:
Correlation of specifications and documents:
Page 2
Standard Procedure For Microwave Swap Site
1,Cutover
(1) Cutover services from other vendor's Microwave to Huawei Microwave RT
(2) Test services after cutover successful
(3) Roll Back procedure
Pole
Antenna
Rack GND
IDU DC Power
ACDB DCDB
IF cable
Ground bar
DDF
IDU
DC power cabinet PGND
Battary
Page 3
Standard Procedure For Microwave Swap Site
Tape measure Marking pen Level bar Percussion drill Claw hammer Torque wrench
Socket wrench Adjustable wrench Phillips screwdriver Flat-head screwdriver Heat gun Multimeter
Wire stripper Sharp-nose pliers Diagonal pliers Pliers Crimping pliers Wire cutter
E1 BER tester Feeder punchdown tool Bayonet wrench Paper knife Ladder File
Procedure
1-A 1-
B
1 Check hardware connection, DDF,E1 cable,ground cable, etc.
Record exiting E1 and Ethernet cables connection and make clear labels in
3
both source and sink sites. This is for roll back in case needed.
Note
2 1
Tools
1 2 3
4 5
Materials
1 2
3 4
5 6
2
3
4
5
Note
3
4
Tools
1 2 3
4 5
Materials
1 2
3 4
5 6
SN Task Description Operator Duration
Standard Procedure For RTN900 Cutover 1.1-C Preparation AB 30 minutes
Procedure
4
5
Note
3
4
Tools
1 2 3
4 5
Materials
1 2
3 4
5 6
Procedure
In the Function Tree, click the tributary board where the loopback is to be
1
performed.
Choose Configuration > PDH Interface in the Function Tree. Then, the PDH
2
Interface page is displayed.
Select the E1 signal to be looped back. Then, double-click Tributary Loopback
3
and select Inloop or Outloop.
4 Click Apply.
5
Fron
Note
t
view 1 E1 inloop indicates that the E1 signal is looped back toward the backplane.
2 E1 inloop indicates that the E1 signal is looped back against the backplane.
Tools
1 2 3
4 5 6
Materials
1 2
3 4
5 6
Page 8
SN Task Description Operator Duration
Standard Installation of OptiX RTN 900
1.2B Test the E1 Services AB 30 minutes
Procedure
Click the tributary board to be tested, and choose Configuration > PRBS Test in
2
the Function Tree. Then, the PRBS Test page is displayed.
Select the E1 signal to be looped back. Double-click Direction and select
3
Tributary. Then, set the test duration to 15 minutes.
Note
The test directions of the PRBS test function as follows. In the tributary direction,
the bit errors from the local DDF to the equipment can be tested. When the
1
remote E1 signal is looped back and the cross direction is selected at the local
end, the bit errors from the radio link to the local tributary board can be tested.
Tools
1 2 3
4 5 6
Materials
1 2
3 4
5 6
Page 9
SN Task Description Operator Duration
Standard Procedure For RTN900 Cutover
1.3 Change jumpers AB 30 minutes
Procedure
Cut over E1 cable connection at both source and sink sites. E1 cut over must be
1
done one by one, and confirm with NOC the current E1 is working properly.
2 Make new jumpers between RTN900 equipment and BTS
After all E1 and Ethernet services cut over are completed, the service is up
3
again. Record the time and report to Huawei and Operator.
4
5
Note
Tools
1 Punching wire pliers 2 Marking pen 3 Diagonal pliers
4 Paper knife 5 6
Materials
1 2
3 4
5 6
4
5
Note
Tools
1 2 3
4 5 6
Materials
1 2
3 4
5 6
Procedure
Note
Tools
1 Cell phone 2 3
4 5 6
Materials
1 2
3 4
5 6
Note
2 No cable ties or other sundries are left on the floor or in the cabinets.
Tools
1 2 3
4 5 6
Materials
1 2
3 4
5 6
Procedure
If the service down time exceeded 4 hours and the swap is not completed, roll
1 back has to be performed. The roll back must be confirmed with Huawei and
Operator in advance.
2 Recover E1 and Ethernet cables as previous connection.
Note
Tools
1 2 3
4 5 6
Materials
1 2
3 4
5 6