Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 40

4.1.

2 Definition of Spatial Elements

Area Specific Area Staff Qualitative Quantitative Area in No. Total


Requirements Sq. Of Area in
Mts Spac sq. mts
e
ADMINISTRATIVE DEPARTMENT
Lobby Waiting Area Visitor Inviting 80 1/perso 1 80
n
Information And Receptionist Open 3 5.02/st 1 15
Reception Area aff
Toilet General Public Typical 10 2 2 48
Toilet For Disable Persons’ With Typical 1 6 1 6
Disability
Budget And Waiting Area General Public Open 40 1/perso 1 40
Finance Office n
Billing Section Billing Clerk Formal 4 1.40/ 2 20
Person
Cashier Section Cashier Formal 1 5.02/st 4 20
aff
Vault Cashier Typical 3 1 3
Office Work Area Employee Formal 20 5.02/st 1 100
aff
Internal Auditor’s Internal Auditor Formal 2 6.00/st 2 24
Office aff
Toilet Staff Typical 1 2 2 5

170 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Medical Medical Record Medical Formal 5 6.00/st 1 30
Records Office Office Record Officer aff
File Storage And Employee Functional 3 4.65/Pe 1 14
Printing rson
Toilet Employee Formal 5 1.67 1 8.35
Administration Office Of The Chief Hospital Formal 4 6.00/st 1 24
Office Of The Hospital Director aff
Office Of The Dept. Department Formal 4 6.00/st 1 24
Head Head Officer aff
Office of the Chief Formal 4 6.00/st 1 24
Oncological Center Oncologist aff
Chief
Office of the Oncology Formal 2 6.00/st 1 12
Oncological Professinal aff
Professional Staff Staff
Office Of The Chief Chief Nurse Formal 5 5.02/Pe 1 25
Nurse rson
Chief Nutritionist Nutritionist Formal 5 5.02/Pe 1 25
Office rson
Chief Of The Clinics Specialist Formal 5 5.02/Pe 1 25
rson
Social Service Office Social Service Formal 5 5.02/Pe 1 25
Officer rson
Human Resource Human Formal 5 5.02/Pe 1 25
Office Resource rson
Manager

171 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Affiliates Room & Librarian/ Functional 40 6.00/st 240
Library; Area Employee aff
Conference Room Employee Formal 40 1.40/pe 1 56
rson
Toilet Employee Typical 5 1.67 1 8.35
Training Office Training Office Training Formal 5 6.00/st 1 30
Director/Officer aff
TOTAL 957
TOTAL AREA with 30 % CIRCULATION 1,330
IMAGING DEPARTMENT
Reception Area Receptionist Open 2 5.06/Pe 1 6
/Attending rson
Personnel
Waiting Area General Public Open 30 0.65/Pe 1 15
rson
Office Of The Dept Department Formal 5 5.06/Pe 1 12
Head Head rson
Officer/Chief
Radiologist
General Office Area Staff Formal 7 5.06/Pe 1 32
rson
Record Area/Film Staff Formal 3 4.65/Pe 1 15
Storage rson
Conference Room Employee Formal 7 1.40/Pe 1 19
rson
Staff Lounge Staff Open 7 1.40/Pe 1 16
172 CHAPTER IV | ARCHITECTURAL PROGRAMMING
rson
Staff Locker Staff Open 7 1.40/Pe 1 10
rson
Tests Toilet Patient Typical 1 3
Control Room Staff/Technicia Specialized 2 4.65/Pe 1 6
n rson
Radiology Room /X- Staff Specialized 4 5.02/Pe 1 24
Ray Room /Technician/ rson
Radiologist
Fluoroscopy Staff/Technicia Specialized 4 5.02/Pe 1 24
Room/X-Ray Room n/ Radiologist rson
Dark Room Staff/Technicia Specialized 1 4.65/Pe 1 11
n/ Radiologist rson
Ct Scan Section Toilet Patient Typical 1 1 2
Ct Scan Room Staff/Technicia Specialized 3 5.02/Pe 1 48
n rson
Control Room Staff/Technicia Specialized 2 4.65/Pe 1 12
n rson
MRI Toilet Patient Typical 1 1 2
MRI Room Staff/Technicia Specialized 3 5.02/Pe 1 48
n rson
Control Room Staff/Technicia Specialized 2 4.65/Pe 1 12
n rson
Ultra Sound Patient Toilet Patient Typical 1 1 2
Ultra-Sound Staff/Technicia Formal 2 5.02/Pe 1 15
Examination Room n rson

173 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Cardiology Examination Area Staff/Technicia Typical 1 7.43/Si 1 7
n ngle
Bed
ECG Machine Room Staff/Technicia Specialized 1 7.43/Si 1 15
n ngle
Bed
2d Echo Machine Staff/Technicia Specialized 1 7.43/Si 1 15
Room n ngle
Bed
Tests Toilet Patient Typical 1 2
Support Toilet Staff Typical 3 1 6
Facilities Toilet General Public Formal 5 11
Wheeled Stretcher Staff Open 1 1.08/Be 1 3
Area d
TOTAL 389
TOTAL AREA with 30 % CIRCULATION 506
DELIVERY AND O.R DEPARTMENT
Major Operating Room Patient/ Staff Functional 37 4 148

Minor Operating Room Patient/ Staff Functional 35 4 140

Recovery Room Patient Functional 25 7.43/be 1 185.75


d
Sub-sterilizing Area Staff Functional 3 5 1 15
Sterile Instrument, Staff Functional 2 5 1 10
Supply and Storage

174 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Area
Scrub-up Area Staff Functional 3 4.65 1 13.95
Clean-up Area Staff 3 4.65 1 13.95
Male Dressing Room Staff Typical 6 3 1 18
Toilet Staff Typical 1 2.4 1 2.4.0
Female Dressing Staff Typical 6 3 1 18
Room
Toilet Staff Functional 1 2.4 1 2.4.0
Nurse Station Staff Functional 8 5.02/staf 1 24
f
Nurse Lounge Staff Typical 20 1.40/per 1 28
son
Wheeled Stretcher Staff 6 1.08/str 1 6.08
Area etche
Janitor’s Closet Staff Typical 3 4 1 12
Surgery Department Head/ Staff Formal 30 6.00/staf 1 180
Office f
Anesthesiology Office Head/ Staff Formal 30 6.00/staf 1 180
f
Doctor’s Lounge Staff Typical 15 1.40/per 1 75
son
Staff Toilet Staff Typical 1 2.4 2 4.8
TOTAL 1,073
TOTAL AREA with 30 % CIRCULATION 1,394
LABORATORY AND DIAGNOSTIC DEPARTMENT
Waiting Area General Area Open 30 0.65/Pe 1 15

175 CHAPTER IV | ARCHITECTURAL PROGRAMMING


rson
Receiving And Staff Formal 2 5.02/Pe 1 6
Releasing Area rson
Head Pathologist Pathologist Formal 4 5.02/Pe 1 12
Office rson
General Office Area Staff Formal 7 5.02/Pe 1 30
rson
Conference Room Employee/Staff Formal 10 1.40/Pe 1 19
rson
Screening And Pathologist Formal 3 5.02/Pe 1 17
Examination Area rson
Blood Donation Staff Formal 5 5.02/Pe 1 20
Room rson
Blood Bank Staff Typical 4 4.65/Pe 1 25
rson
Staff Locker Staff Typical 7 1.40/Pe 1 10
rson
Laboratories Chemistry Lab. Chemist Specialized 4 4.65/Pe 1 29
rson
Bacteriology Lab. Bacteriologist Specialized 4 4.65/Pe 1 30
rson
Histopathology Lab. Specialist Specialized 4 4.65/Pe 1 30
rson
Hematology Lab. Specialist Specialized 4 4.65/Pe 1 29
rson
Serology Lab. Specialist Specialized 4 4.65/Pe 1 29

176 CHAPTER IV | ARCHITECTURAL PROGRAMMING


rson
Support Staff Toilet Staff Typical 3 6
Facilities Staff Locker Staff Open 7 1.40/Pe 1 10
rson
Toilet Patient Typical 5 8
Storage Room Staff Typical 2 4.65/Pe 1 5
rson
Autoclave Room Staff Typical 1 4
Glass Washing Area Staff Open 3 4.65/Pe 1 19
rson
Clean Utility Area Staff Typical 2 4.65/Pe 1 2
rson
Wheeled Stretcher Staff Open 1 1.08/Be 1 3
Area d
TOTAL 357
TOTAL AREA with 30 % CIRCULATION 464
EMERGENCY DEPARTMENT
Public Area Arrival Area Patient Open 10 1.08/Str 1 11
etcher
Decontamination Staff Specialized 2 7.43/Be 18
Area d
Reception Triage Attending Open 2 5.02/Pe 1 11
Personnel/Rec rson
eptionist/ Staff
Admission/ Staff Formal 5 5.02/Pe 1 25
Discharge Area rson
177 CHAPTER IV | ARCHITECTURAL PROGRAMMING
Waiting Area Visitor/Patient Open 10 0.65/Pe 1 8
rson
Sub- Patient Isolation Room Patient Specialized 1 7.43/Be 2 18
Area d
Examination And Attending Typical 4 7.43/Be 1 106
Treatment Area Personnel/ d
Doctor
Minor Operating Attending Typical 1 12/Bed 2 24
Room Personnel/
Doctor
On-Call Room Staff Typical 3 5.02/Pe 1 16
rson
Support Toilet Staff Typical 3 1 5
Facilities Toilet General Public Typical 5 1 8
Nurse Station Staff Typical 5 5.02/Pe 1 79
rson
Nurse on-call Room Staff Typical 5 5.02/Pe 1 18
rson
Pharmacy Staff Typical 5 5.02/Pe 1 18
rson
Clean Utility Area Staff Typical 2 4.65/Pe 1 4
rson
Dirty Utility Area Staff Typical 2 4.65/Pe 1 4
rson
Wheeled Stretcher Staff Open 2 1.08/Str 1 3
Area etcher

178 CHAPTER IV | ARCHITECTURAL PROGRAMMING


TOTAL 375
TOTAL AREA with 30 % CIRCULATION 487
INPATIENT DEPARTMENT
Surgical Ward 9-Beds Patient Functional 9 7.43/be 3 201
(Male) d
10-Beds Patient Functional 10 7.43/be 1 74
d
Toilet Patient/Visitors Typical 1 2 4 10
Nurse’s Station Staff Typical 4 5.02/st 1 20
aff
Toilet Staff Typical 1 2 1 2
Clean Utility Area Staff Typical 2 5 1 9
Surgical Bed 9-Beds Patient Functional 9 7.43/be 2 134
Ward (Female) d
10-Beds Patient Functional 10 7.43/be 2 147
d
Toilet Patient/Visitors Typical 1 2 4 10
Nurse’s Station Staff Typical 4 5.02/st 1 20
aff
Toilet Staff Typical 1 2 1 2
Clean Utility Area Staff Typical 2 5 1 9
Medical 9-Beds Patient Functional 9 7.43/be 2 134
Ward(Non- d
Communicable) 10-Beds Patient Functional 10 7.43/be 2 147
d

179 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Toilet Patient/Visitors Typical 1 2 4 10
Nurse’s Station Staff Typical 4 5.02/st 1 20
aff
Toilet Staff Typical 1 2 1 2
Clean Utility Area Staff Typical 2 5 1 9
Medical Ward 9-Beds Patient Functional 9 7.43/be 3 201
(Communicable d
) 10-Beds Patient Functional 10 7.43/be 1 74
d
Toilet Patient/Visitors Typical 1 2 4 10
Nurse’s Station Staff Typical 4 5.02/st 1 20
aff
Toilet Staff Typical 1 2 1 2
Clean Utility Area Staff Typical 2 5 1 9
Obstetrics 5-Beds Obstetrics Patient Functional 5 7.43/be 4 149
Gynecology Gynecology Ward d
Ward Toilet Patient/Visitors Typical 1 2 4 10
Nurse’s Station Staff Typical 4 5.02/st 1 20
aff
Toilet Staff Typical 1 2 1 2
Clean Utility Area Staff Typical 2 5 1 9
Psychiatry Ward 9-Beds Patient Functional 9 7.43/be 3 201
(Male) d
10-Beds Patient Functional 10 7.43/be 1 74
d
Toilet Patient/Visitors Typical 1 2 4 10
180 CHAPTER IV | ARCHITECTURAL PROGRAMMING
Nurse’s Station Staff Typical 4 5.02/st 1 20
aff
Toilet Staff Typical 1 2 1 2
Clean Utility Area Staff Typical 2 5 1 9
Psychiatry Ward 9-Beds Patient Functional 9 7.43/be 2 134
(Female) d
10-Beds Patient Functional 10 7.43/be 2 147
d
Toilet Patient/Visitors Typical 1 2 4 10
Nurse’s Station Staff Typical 4 5.02/st 1 20
aff
Toilet Staff Typical 1 2 1 2
Clean Utility Area Staff Typical 2 5 1 9
Pediatrics Ward 9-Beds Patient Functional 9 7.43/be 2 134
d
10-Beds Patient Functional 10 7.43/be 2 147
d
Toilet Patient/Visitors Typical 1 2 3 7
Nurse’s Station Staff Typical 4 5.02/st 1 20
aff
Toilet Staff Typical 1 2 1 2
Clean Utility Area Staff Typical 2 5 1 9
Semi Private - 2-Beds Patient Functional 2 7.43/be 28 416
Room d
- 3-Beds Patient Functional 3 7.43/be 19 446
d
181 CHAPTER IV | ARCHITECTURAL PROGRAMMING
- 4-beds Patient Functional 4 7.43/be 16 476
d
Toilet Patient/Visitors Typical 1 2 63 151
Nurse’s Station Staff Typical 6 5.02/st 3 90
aff
Toilet Staff Typical 1 2 3 7
Clean Utility Area Staff Typical 2 5 1 9
Private Room Private Room Patient Functional 1 7.43/be 40 297
d
Toilet Patient/Visitors Typical 1 2 40 96
Nurse’s Station Staff Typical 6 5.02/st 1 30
aff
Toilet Staff Typical 1 2 1 2
Clean Utility Area Staff Typical 2 5 1 9
TOTAL 4,454
TOTAL AREA with 30 % CIRCULATION 5,799
SERVICE DEPARTMENT
Dietary Nutrition Counseling Nutritionist Formal 3 6.00/st 1 24
Room aff
Supply Receiving Staff Typical 4 5 1 20
Area
Dry Storage Area Staff Typical 4 5 1 20
Cold Storage Area Staff Typical
Food Preparation Staff Typical 6 5 1 30
Area

182 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Cooking And Baking Staff Functional 6 6.00/st 1 36
Area aff
Snack Preparation Staff Functional 3 4.65 1 13.95
Area
Dish Washing Area Staff Typical 3 4.65 1 25
Equipment Storage Staff Typical 3 4.65 1 15
Area
Dining Area Staff/Dietetics Inviting ## 2 1 200
Staff
Toilet Staff Typical 6 1.67/fa 2 5.1
cility
Accessible Toilet PWD Typical 5 6 1 6
Laundry Receiving Area Staff Functional 3 3 1 90
Soiled Linen Area Staff Typical 3 3 1 9
Wash Laundry Area Staff Functional 5 6.00/st 1 30
aff
Ironing And Pressing Staff Functional 3 5.02/Pe 1 15
Room rson
Storage Room Staff Typical 3 5.02/Pe 1 15
rson
Toilet Staff Typical 6 1.67/fa 2 5.1
cility
Pharmacy Reception Area Receptionist Formal 1 5.02/Pe 1 8.7
rson
General Waiting Patient/ Visitor Open 10 0.65/Pe 1 7
Area rson

183 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Dispensing Pharmacist/Sta Open 1 1.40/Pe 1 3
Counter /Information ff rson
Cashier Area Cashier Formal 2 1.40/Pe 1 3
rson
Chief Pharmacist Chief Formal 3 5.02/Pe 1 7
Office Pharmacist rson
Staff Locker Staff Typical 3 2.32/Lo 2 8
cker
Area
Delivery/. Unpack/ Staff Typical 1 1.40/Pe 1 7
receiving area rson
Bulk Storage Staff/ Typical 4 4.65/Pe 1 19
Pharmacist rson
Toilet Staff Typical 3 2 5
Security Office General Office Employee Formal 5 5.02/Pe 1 45
rson
Surveillance and Employee Functional 5 5.02/Pe 1 30
control room rson
Sleeping Quarters Employee Formal 5 5.02/Pe 1 32
rson
Toilet Staff Typical 3 2 5
Staff Locker Staff Open 7 1.40/Pe 1 10
rson
Central Receiving And Staff Open 3 5.02/Pe 1 15
Sterilizing And Releasing Area rson
Supply Area General Office Staff Open 7 5.02/Pe 1 35

184 CHAPTER IV | ARCHITECTURAL PROGRAMMING


rson
Sterile Supply Staff Functional 3 4.65/Pe 1 14
Storage Area rson
Washing area Staff Functional 1 1 32
Packing Area Staff Functional 1 1 32
Sterilization Area Staff Functional 1 1 32
TOTAL 908
TOTAL AREA with 30 % CIRCULATION 1,181
MORTUARY
Lobby Patients’ Open 7 0.65/Pe 1 5
Relative/Staff rson
Waiting/ Praying Patients’ Open 7 0.65/Pe 1 5
Area Relative rson
Autopsy Room Specialist Specialized 2 7.43/ 1 15
Bed
Morgue Cadaver Specialized 1 1 12
Staff Locker Staff Typical 5 1.40/Pe 1 7
rson
Toilet Staff Typical 1 1 2
TOTAL 45
TOTAL AREA with 30 % CIRCULATION 58
OUTPATIENT DEPARTMENT
Waiting Area Visitor Open ## 0.65/Pe 1 30
rson
Reception Area Receptionist Open 5 5.02/Pe 1 6

185 CHAPTER IV | ARCHITECTURAL PROGRAMMING


rson
Treatment Attending Typical 14 7.43/Si 1 104
Area/Examination Personnel/Doct ngle
Room or Bed
Office Of The Dept. Dept. Head Formal 5 5.02/Pe 1 25
Head Officer rson
Clinics General Medicine Specialist Formal 5 5.02/Pe 1 30
Clinic rson
Dental Clinic Dentist Formal 5 5.02/Pe 1 30
rson
Pediatrics Clinic Pediatrician Formal 5 5.02/Pe 1 30
rson
Obstetrics And Gynecologist Formal 5 5.02/Pe 1 30
Gynecology Clinic rson
Orthopedics Clinic Specialist Formal 5 5.02/Pe 1 30
rson
Pulmonanology Pulmonologist Formal 5 5.02/Pe 1 30
Clinic rson
Ophthalmology Ophthalmologi Formal 5 5.02/Pe 1 30
Clinic st rson
Internal Medicine Specialist Formal 5 5.02/Pe 1 30
Clinic rson
Psychiatry Clinic Psychiatrist Formal 5 5.02/Pe 1 30
rson
Neurology Clinic Neurologist Formal 5 5.02/Pe 1 30
rson

186 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Dermatology Clinic Dermatologist Formal 5 5.02/Pe 1 30
rson
Endocrinology Clinic Endocrinologist Formal 5 5.02/Pe 1 30
rson
Surgery Clinic Surgeon / Formal 5 5.02/Pe 1 30
Specialist rson
EENT Clinic Physician Formal 5 5.02/Pe 1 30
rson
Support Toilet Staff Typical 10 1 6
Facilities Toilet General Public Formal 20 1 34
Toilet For Disabled Person With Specialized 2 1 5
Disability
Clean Utility Area Staff Typical 1 4.65/Pe 1 10
rson
Dirty Utility Area Staff Typical 1 4.65/Pe 1 10
rson
Wheeled Stretcher Staff Open 5 1.08/Be 1 3
Area d
TOTAL 653
TOTAL AREA with 30 % CIRCULATION 849
PHYSICAL THERAPY DEPARTMENT
Waiting Area General Area Open 20 0.65/Pe 1 24
rson
Toilet Staff Typical 3 6
Staff Locker Staff Open 7 1.40/Pe 1 10
rson
187 CHAPTER IV | ARCHITECTURAL PROGRAMMING
General Office Area Staff Formal 7 5.02/Pe 29
rson
Screening Area Staff Formal 3 5.02/Pe 1 18
rson
Examination Room Patients Typical 5 7.43 / 4 70
Bed
Equipment Area Patients Open 4 2 285
Wheeled Stretcher Staff Open 1 1.08/Be 1 3
Area d
TOTAL 50 8 445
TOTAL AREA with 30 % CIRCULATION 579
INTENSIVE CARE DEPARTMENT
Patient Area Transfer Area Staff Open 1 1.08/Str 2 12
etcher
Reception Area Staff Open 1 5.02/Pe 2 10
rson
Anteroom Visitor/Relative Typical 1 5.02/Pe 2 10
s rson
ICU Bed Ward Attending Specialized 4 12/Pati 2 20
Personnel/Staff ent
Staff Area ICU Supervisor ICU Supervisor Formal 3 5.02/Pe 2 16
Room rson
Mini Laboratory Staff Typical 3 4.65/Pe 2 28
rson
Work Area Staff Formal 3 5.02/Pe 2 30
rson
188 CHAPTER IV | ARCHITECTURAL PROGRAMMING
Staff Locker Area Staff Typical 7 1.40/Pe 2 7
rson
Support Nurse Station Staff Typical 5 5.02/Pe 2 31
Facilities rson
Anesthesia Storage Staff Specialized 3 4.65/Pe 2 6
rson
Supply Storage Staff Typical 3 4.65/Pe 2 16
rson
Toilet Staff Typical 3 2 8
Clean Utility Area Staff Typical 1 4.65/Pe 2 2
rson
Wheeled Stretcher Staff Open 1 1.08/Str 2 3
Area etcher
TOTAL 199
TOTAL AREA with 30 % CIRCULATION 258
OBSTERICAL SERVICES
Delivery Room Patient/ Staff Functional 1 35 4 140

Labor Room with Patient Functional 10 7.43/be 1 74.3


Toilet d
Recovery Room Patient Functional 10 7.43/be 1 60
d
Sub-sterilizing Area Staff Functional 3 5 1 15
Sterile Instrument, Staff Functional 2 5 1 10
Supply and Storage
Area

189 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Scrub-up Area Staff Functional 3 4.65 1 13.95
Clean-up Area Staff 4.65 1 13.95
Male Dressing Room Staff Functional 3 3 1 9
Toilet Staff Functional 1 2.4 1 2.4
Female Dressing Staff Functional 5 3 1 15
Room
Toilet Staff Functional 1 2.4 1 2.4
Nurse Station Staff Functional 4 5.02/staf 1 20.08
f
Nurse Lounge Staff Typical 15 3 1 45
Wheeled Stretcher Staff Open 3 1.08/str 1 3.24
Area etcher
Janitor’s Closet Staff Typical 2 4 1 8
TOTAL 432
TOTAL AREA with 30 % CIRCULATION 562
Dialysis Unit
Lobby Visitors Accessible ## 1 1 100
Waiting Area Visitors Accessible 30 1 1 30
Toilet Public Typical 4 3 2 20
Accessible Toilet PWD Typical 1 6 1 6
Registration Staff Formal 3 6 1 18
Assessment & Billing Staff Formal 3 3 1 18
Administrative Office Staff Formal 8 6 1 48
Toilet Staff Typical 1 2 1 2
Hemodialysis Unit Patient- Staff Functional 10 10 1 100

190 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Peritoneal Dialysis Patient- Staff Functional 10 10 1 100
Unit
Nurse Station Staff Functional 8 3 1 24
Sub-sterilizing Area Staff Functional 1 6 1 6
Sterile Instrument, 1 10
Supply and Storage
Area
Scub-up Area Staff Functional 2 3 1 6
Clean-up Area Staff 1 6
Male Dressing Room Staff Functional 3 3 1 9
Toilet Staff Functional 1 2 1 2
Female Dressing Staff Functional 3 3 1 9
Room
Toilet Staff Functional 1 2 2 5
Doctor’s Lounge Staff Typical 10 5 1 50
Nurses Lounge Staff Typical 20 3 1 60
Doctor’s Clinic Patient- Staff Functional 4 10 1 40
Doctor’s Office Staff Formal 3 6 1 18
Nurse Station Staff Functional 5 3 1 15
Water Treatment 1 50
and Processing
Room
Conference Room Staff Formal 50 4 1 200
Board Room Staff Formal 15 4 1 60
Stock Room Open 1 15

191 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Staff Toilet Staff Typical 6 3 1 15
TOTAL 1,042
TOTAL AREA with 30 % CIRCULATION 1,355
DEPARTMENT OF NUCLEAR MEDICINE
Radiation Waiting Area (for Open 20 0.65 1 13
Oncology OPD) m2/
person
Reception Area Open 3 5.02 1 15
m2/
person
Toilet Typical 6 1.67 1 10
m2/per
son
Toilet for Disabled Typical 1 2.10 1 2
m2/per
son
X-ray Room Waiting Area Open 10 0.65 1 7
m2/
person
Preparation Area Typical 2 1 1 3
(Dressing Room)
X-ray Room Formal 1 14.00 1 14
m2
Control Room Typical 1 8 m2 1 8
Storage Area Formal 2 4.65m² 1 9
Mammography Waiting Area Open 10 0.65 1 7
192 CHAPTER IV | ARCHITECTURAL PROGRAMMING
m2/
person
Preparation Area Formal 4 5.02 1 10
(Dressing Room) m2/
person
Examination Room Formal 2 7.43m²/ 1 15
bed
Office Formal 6 5.02 1 30
m2/
person
Storage Area Formal 2 4.65m² 1 9
CT Scan/PET Waiting Area Open 10 0.65 1 7
(Positron m2/
Emission person
Tomography) Preparation Area Formal 2 5.02 1 10
Scan (Dressing Room) m2/
person
Examination Room Formal 1 7.43m²/ 1 80
bed
Control Room Typical 1 8 m2 1 8
Office Formal 4 5.02 1 20
m2/
person
Storage Area Formal 2 4.65m² 1 9
MRI (Magnetic Waiting Area Open 10 0.65 1 7
Resonance m2/

193 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Imaging) Scan person
Preparation Area Formal 2 5.02 1 10
(Dressing Room) m2/per
sonnel
Examination Room Formal 1 80 m2 1 80
Control Room Typical 1 8 m2 1 8
Office Formal 4 5.02m²/ 1 20
person
nel
Storage Area Formal 2 4.65m² 1 9
General Waiting Area Open 10 0.65 1 7
Ultrasound m2/
person
Preparation Area Formal 2 5.02 1 10
(Dressing Room) m2/per
sonnel
Examination Room Formal 2 7.43m²/ 1 15
bed
Office Formal 4 5.02m²/ 1 20
person
nel
Storage Area Formal 2 4.65m² 1 9
Endoscopy Waiting Area Open 10 0.65 1 7
m2/
person
Consultation Room Formal 2 6 1 18
194 CHAPTER IV | ARCHITECTURAL PROGRAMMING
m2/per
sonnel
Preparation Area Formal 2 5.02 1 10
(Dressing Room) m2/per
sonnel
Examination Room Formal 5 7.43m²/ 1 37
bed
Recovery Room Formal 5 7.43m²/ 1 37
bed
Toilet Typical 6 1.67 1 10
m2/per
son
Toilet for Disabled Typical 1 2.10 1 2
m2/per
son
Radiation Waiting Area Open 20 0.65 1 13
Therapy m2/
person
Preparation Area Typical 2 1.40 1 3
(Dressing Room) m2
External Beam Formal 2 80 m2 1 160
Therapy Room
(Linear Accelerator)
Control Room Formal 6 4.65 1 14
m2/per
sonnel

195 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Brachytherapy Formal 4 40 m2 1 160
Treatment Room
Control Room Formal 8 4.65 1 37
m2/per
sonnel
Dark Room Formal 2 4.65 1 9
m2/per
sonnel
Sluice Room Formal 2 4.65 1 9
m2/per
sonnel
Recovery Room Formal 6 7.43 1 45
m2/bed
Toilet for Disabled Typical 1 2.10 1 2
m2/per
son
Office Formal 4 5.02m²/ 1 20
person
nel
Storage Area Formal 2 4.65 1 9
m2/per
sonnel
Obstetrics Obstetrics Outpatient Formal 1 195
Department Ultrasound and 3d Formal 1 62
Ultrasound Room
Obstetrics Surgical Formal 1 600

196 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Department
Nursery Room Formal 1 170
Gynaecology Waiting Lounge Open 1 199
Department Reception & Open 2 5.02 1 78
Dressing Area m2/per
sonnel
Records Releasing Formal 1 16
Room
Consultation Room Formal 1 54
Preliminary Formal 1 48
Examination (2)
Examination Waiting Open 20 0.65m2 1 87
Lounge /
person
Counseling Room Formal 1 36
Examination/Treatm Formal 10 15m2/p 1 330
ent Rooms (4) ersonn
el
Medical Staff’s Formal 1 173
Quarter
Chemotheraphy Formal 1 294
Infusion Area (with
Public and Private
Infusion)
Breast Waiting Lounge Open 1 216
Department Reception & Open 5.02 1 153

197 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Dressing Area m2/per
sonnel
Records Releasing Typical 1 12
Room
Consultation Room Formal 1 40
(2)
Examination Waiting Open 0.65m2 1 50
Lounge /
person
Counseling Room Formal 1 28
Preliminary Formal 1 40
Examination (2)
Examination/ Formal 15m2/p 1 180
Treatment Rooms ersonn
(4) el
Medical Staff’s Office Formal 1 117
Chemotheraphy Formal 1 375
Infusion Area (with
Public and Private
Infusion)
Genitourinary Waiting Lounge Open 1 199
Department Reception & Open 2 5.02 1 78
Dressing Area m2/per
sonnel
Records Releasing Formal 1 16
Room

198 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Consultation Room Formal 1 54
Preliminary Formal 1 48
Examination (2)
Examination Waiting Open 20 0.65m2 1 87
Lounge /
person
Counseling Room Formal 1 36
Examination/Treatm Formal 10 15m2/p 1 330
ent Rooms (4) ersonn
el
Medical Staff’s Formal 1 173
Quarter
Chemotheraphy Formal 1 294
Infusion Area (with
Public and Private
Infusion)
Leukemia Waiting Lounge Open 1 216
Department Reception & Open 5.02 1 153
Dressing Area m2/per
sonnel
Records Releasing Typical 1 12
Room
Consultation Room Formal 1 40
(2)
Examination Waiting Open 0.65m2 1 50
Lounge /

199 CHAPTER IV | ARCHITECTURAL PROGRAMMING


person
Counseling Room Formal 1 28
Preliminary Formal 15m2/p 1 40
Examination (2) ersonn
el
Examination/ Formal 1 180
Treatment Rooms
(4)
Medical Staff’s Office Formal 1 117
Chemotheraphy Formal 1 375
Infusion
Head and Neck Waiting Lounge Open 1 199
Department Reception & Open 5.02 1 78
Dressing Area m2/per
sonnel
Records Releasing Formal 1 16
Room
Consultation Room Formal 1 54
Preliminary Formal 1 48
Examination (2)
Examination Waiting Open 0.65m2 1 87
Lounge /
person
Counseling Room Formal 1 36
Examination/Treatm Formal 15m2/p 1 330
ent Rooms (4) ersonn

200 CHAPTER IV | ARCHITECTURAL PROGRAMMING


el
Medical Staff’s Formal 1 173
Quarter
Chemotheraphy Formal 1 294
Infusion Area (with
Public and Private
Infusion)
Orthopedic Waiting Lounge Open 1 216
Department Reception & Open 5.02 1 153
Dressing Area m2/per
sonnel
Records Releasing Typical 1 12
Room
Consultation Room Formal 1 40
(2)
Counseling Room Open 0.65m2 1 50
/
person
Preliminary Formal 1 28
Examination (2)
Examination/ Formal 15m2/p 1 40
Treatment Rooms ersonn
(4) el
Medical Staff’s Office Formal 1 180
Chemotheraphy Formal 1 117
Infusion

201 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Area (with Public Formal 1 375
and Private Infusion)
Thoracic Waiting Lounge Open 1 199
Department Reception & Open 5.02m2 1 78
Dressing Area /person
nel
Records Releasing Formal 1 16
Room
Consultation Room Formal 1 54
Preliminary Formal 1 48
Examination (2)
Examination Waiting Open 0.65m2 1 87
Lounge /
person
Counseling Room Formal 1 36
Examination/Treatm Formal 15m2/p 1 330
ent Rooms (4) ersonn
el
Medical Staff’s Formal 1 173
Quarter
Chemotheraphy Formal 1 294
Infusion Area (with
Public and Private
Infusion)
Gastroenterolog Waiting Lounge Open 1 216
y Department Reception & Open 5.02 1 153

202 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Dressing Area m2/per
sonnel
Records Releasing Typical 1 12
Room
Consultation Room Formal 1 40
(2)
Examination Waiting 0.65m2 1
Lounge /
person
Counseling Room Open 1 50
Preliminary Formal 1 28
Examination (2)
Examination/ Formal 15m2/p 1 40
Treatment Rooms ersonn
(4) el
Medical Staff’s Office Formal 1 180
Chemotheraphy Formal 1 117
Infusion Area (with
Public and Private
Infusion)
Waiting Lounge Formal 1 375
TOTAL 12,214
TOTAL AREA with 30 % CIRCULATION 15,878
RESEARCH AND TRAINING CENTER
Research Therapeutic Formal 12 260
Center Development
203 CHAPTER IV | ARCHITECTURAL PROGRAMMING
Program
Cancer Prevention Formal 12 260
and Control Program
Cancer Imaging Formal 12 260
Program
Cancer Biology Formal 12 260
Program
Autoclave Room Formal 46
Biotech Room Formal 48
Polymerase Chain Formal 50
Reaction Laboratory
Library & Report Formal 100
Write Up Space
Meeting Room Formal 32
Laboratory (3) Typical 284
General Storage Typical 44
Training Center Lecture Rooms (6) Typical 390
Faculty Room 6 92
m2/per
sonnel
Laboratory Typical 97
Comfort Rooms (6) Typical 126
Locker Rooms (6) Typical 186
Audiovisual Rooms Typical 194
(2)
Library Formal 388
204 CHAPTER IV | ARCHITECTURAL PROGRAMMING
Computer Formal 97
Laboratory
Chaplaincy Catholic Chapel Public Solemn ## 1 140
Interdominational Public Solemn ## 1 140
TOTAL 3,214
TOTAL AREA with 30 % CIRCULATION 4,178
REHABILITATION CENTER
Outdoor Resting Open - - - 214.21
Area
Lobby, Reception & Open - - - 227.4
Sitting Area
Patient Waiting Open - - - 62
Lounge
Triage Formal - - - 30
Wheelchair Alcove Formal - - - 6
Consultation Rooms Formal - - - 44
(4)
Yoga Room Formal - - - 220
Break Room Formal - - - 12
PWD Toilets (2) Formal - - - 10
Therapy Rooms (15) Formal - - - 165
Medical Staff & Formal - - - 195
Therapists’ Quarter
Naturopathic Formal - - - 52
Medicine

205 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Examination Room
Herb Room Formal - - - 60.8
Public Toilet Formal - - - 120
Nurse Station Formal - - - 58
Doctor-On-Call Formal - - - 40
Office
On-Call Therapist’s Formal - - - 40
Office
Rehabilitation Gym Open - - - 870
TOTAL 2,426
TOTAL AREA with 30 % CIRCULATION 3,154
MUSEUM
Lobby Public Open 50 1 1 50
Information Area Staff Open 3 1 1 3
Gallery 1 Public Open 50 1 1 50
Atrium Sculpture Public Open 20 4 1 80
Garden
Gallery 2 Public Open 50 4 1 200
Workshop Room Private Functional 20 4 2 160
Workshop Private Functional 20 4 2 160
Gallery 3 Public Open 50 4 1 200
Toilet (M) Public Accessible 8 2 1 16
Toilet (F) Public Accessible 8 2 1 16
NON PUBLIC Collection Storage Staff Functional 5 15 1 75
COLLECTION Transit Storage Staff Functional 2 27 1 54
206 CHAPTER IV | ARCHITECTURAL PROGRAMMING
ZONE Exterior Loading Staff 2 10 1 20
Dock
Shippings and Staff Open 6 5 1 27
Receiving
NON PUBLIC Office Staff Functional 12 5 1 54
NON Office toilet Staff Accessible 2 1 1 2
COLLECTION Employees Lounge Staff Open 5 2 1 10
ZONE Pantry Staff Open 2 1 2
Employees Locker Staff Open 1 1 1
Room
Gallery Storage Staff Functional 2 1 2
Mechanical Room Maintenance Functional 2 7 1 14
Electrical Room Maintenance Functional 2 7 1 14
Controll Room Maintenance Functional 6 6 1 33
Generator Set Maintenance Functional 2 10 1 20
Transformer Maintenance Functional 2 10 1 20
Utility Room Maintenance Functional 2 2 1 4
TOTAL 1,287
TOTAL AREA with 30 % CIRCULATION 1,673
DORMITORY
Lobby /Waiting Area Visitor Inviting 50 1/perso 1 50
n
Toilet Visitor Typical 10 2.4 2 48
Dormitory Admin Staff Formal 5 6.00/staf 1 30
Office f

207 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Toilet staff Typical 5 2.4 2 24
Doctors dormitory doctor/Visitors Typical 4 36 7 252

Nurse dormitory nurse/Visitors Typical 8 40 12 480

Transient dormitory Visitor Typical 8 40 4 160


storage room Staff Typical 2 6 1 6
Electrical room Staff Typical 2 6 1 6
TOTAL 1,056
TOTAL AREA with 30 % CIRCULATION 1,373
MOTORPOOL AND MAINTENANCE
Maintenance Office Maintenance Formal 3 5.02/Pe 1 15
Officer rson
Electrical Maintenance Functional 2 4.65/Pe 1 18
Room/Power House Staff rson
Multi- Purpose Area Maintenance Functional 10 1.40/Pe 1 36
Staff rson
Equipment Area Maintenance Open 2 4.65/Pe 1 26
Staff rson
Locker Room Staff Typical 7 1.4/Per 13
son
Toilet Staff Typical 5 8
TOTAL 116
TOTAL AREA with 30 % CIRCULATION 151
GENERAL SERVICES

208 CHAPTER IV | ARCHITECTURAL PROGRAMMING


Elevator Lobby Accessible 480 1 480
Elevator Shaft structural 387 1 387
Ramp Open 4 150 1 600
Cafeteria Public Inviting 250 2 500
Security Office with Head/ Staff Formal 4 5 1 20
toilet
CCTV Room Staff Functional 2 10 1 20
Security Post Staff Typical 2 20 1 40
TOTAL 2,047
TOTAL AREA with 30 % CIRCULATION 2,661
GENERAL SERVICES
Healing and Tranquil All Accessible, 7,000
garden Refreshing,
Inviting
TOTAL 7,000
TOTAL 51,456.57