Load Banks Catalog
Load Banks Catalog
Load Banks Catalog
2019
Our Trademarks
by Aktif
Where we are?
Load Banks................................................................................................................................................................................................................................................................................4
Areas of Use.............................................................................................................................................................................................................................................................................4
Electrical Specifications...................................................................................................................................................................................................................................................4
Physical Properties..............................................................................................................................................................................................................................................................5
Load Bank Control Types...............................................................................................................................................................................................................................................6
Load Banks Coding.............................................................................................................................................................................................................................................................7
3
Load Banks are used performance tests of generators, UPS,
voltage regulators, power transformers, alternators and
test laboratories and also ensure to operate the generators
safely (dummy load) Aktif manufactures all type of load
banks with the required;
• Characteristics (R, L, C)
• Electrical characteristics (AC, DC, V, A, kW)
• Stage precision
• Control (manual, HMI-controlled or automatic)
• Measuring methods
• Installation (indoor or outdoor)
• Rack mounted, portable, stationary and trailer mounted
alternatives
Electrical Specifications
• Resistive (kW-cosø: 1)
• Inductive (kVAr)
• Resistive + Inductive + Capacitive (kVA-cosØ : requested)
Outdoor Type Load Bank (IP54 During Storage) Special designs can be made for different frequency and
cosø values.
Physical Properties
5 www.aktif.net
Load Banks
Load Bank Control Types
“N0” Control Model
“N0” control model is used if the customer wants to control the
load bank themselves.Load bank includes loads, fans, sensors
and an empty control panel. The power cables of the loads,
the supply of the fans and the contacts of the sensors are
drawn into the terminals in the empty control panel.
“N1” Control Model
It is the simplest and cheapest control model. Each load
phase is directly switched with miniature circuit breaker or
cam switches. A wattmeter is used for measurement.
“N2” Control Model
Loads are protected with miniature circuit breakers or
compact circuit breakers and switched with contactors. Load
contactors are controlled with buttons and their indicators
on the control panel.
The network analyzer on the control panel is used for
N1 – Control Model measurement. This analyzer allows reading of kW, kVAr,
kVA, A, V, f, cosø ... etc. Optionally, an analyzer with PC
communication (RS212, RS458 or USB port) is used to monitor
the measured values on the PC.
The following safety precautions are taken in the load bank;
• Overcurrent (with miniature circuit breakers or compact
circuit breakers)
• Overtemperature (with thermal contactors)
• Overvoltage and low voltage if requested
• Fan blowing error (with airflow sensor if the fan cannot
blow)
Loads can be switched on only when there is no safety issue.
“N3” Control Model
Loads are protected with miniature circuit breakers or
compact circuit breakers and switched with contactors. Load
contactors are controlled through the interface of touchscreen
“TFT LCD HMI Panel”. HMI runs with a microprocessor-based
electronic control board or in integration with the PLC and
with a communicating network analyzer.
Operator can manually switch on all loads individually or all
in one go via the HMI interface and can automatically control
N2 – Control Model with many control options and scenario. In addition, kW,
kVAr, kVA, A, V, f, cosø, etc. are monitored on the HMI screen.
These values can also be stored on the HMI’s memory card.
The following safety precautions are taken in the load bank
• Overcurrent (with miniature circuit breakers or compact
circuit breakers)
• Overtemperature (with thermal contactors)
• Overvoltage and low voltage if requested
• Fan blowing error (with airflow sensor if the fan cannot
blow)
Loads can be switched on only when there is no safety issue.
In addition, all errors are monitored on HMI screen.
N3 – Control Model
www.aktif.net 6
Load Banks
compact circuit breakers and switched with contactors. Load 101 - 200 51 - 100 1-1 1350 900 1900
contactors are controlled through the interface of touchscreen 201 - 300 101 - 150 1-1 1500 900 1900
“TFT LCD HMI Panel”. HMI runs with a microprocessor-based
301 - 400 151 - 200 1-1 2000 1200 1790
electronic control board or in integration with the PLC and
with a communicating network analyzer. 401 - 500 201 - 250 1-1 2000 1300 1950
501 - 600 251 - 300 1-1 2150 1300 1950
No-load operation of generators is not requested. In this
case, Load Bank automatically provides artificial load by 601 - 800 301 - 400 1-1 2400 1400 2110
microprocessor-based electronic control board or PLC when 801 - 1000 401 - 500 1-1 2400 1600 2500
the load supplied by a generator falls below a certain level 1001 - 1250 501 - 625 1-1 2550 1600 2500
(ideally 30%).
1251 - 1500 626 - 750 1-1 2700 1600 2500
The following safety precautions are taken in the load bank 1751 - 2000 876 - 1000 1-1 2720 1900 3050
• Overcurrent (with miniature circuit breakers or compact 2001 - 2500 1001 - 1250 1-1 2870 1900 3050
circuit breakers) 2501 - 3000 1251 - 1500 1-1 3150 1900 3050
• Overtemperature (with thermal contactors)
• Overvoltage and low voltage if requested
b
• Fan blowing error (with airflow sensor if the fan cannot a
blow)
Loads can be switched on only when there is no safety issue.
In addition, all errors are monitored on HMI screen.
7 www.aktif.net
Load Banks
For Outdoor (IP23/IP54) Use
Load Step Enclosure Trailer
Power
Resolution Dimension Type
KVA c b
kW kW - kVAr a [mm] b [mm] kW kVA
(Cosfi 0,8) [mm]
Trailer Specifications
Max. Gross
Dimensions
Weight
Type Class Axles Type Axles Number Drawbar Type
a b c
[kg]
[mm] [mm] [mm]
a
TR-1 b .
c
.
a
TR-2 b
.
c
.
a b
TR-3
.
c .
a b
TR-4
.
c .
a b
TR-5
.
c .
www.aktif.net 8
Load Banks Coding
L B 1 - 22 - 3333 4 5 6 - 777 88 9
L B Load Banks
1 Characteristics of Load
R : Resistive
L : Inductive
C : Resistive + Inductive or Resistive + Inductive + Capacative
22 Enclosure Type
00 : Special Dimension
01 : Standard Dimension (From 01 to 13)
C1 : 10 feet Container (Standard or High Cube)
C2 : 20 feet Container (Standard or High Cube)
C4 : 40 feet Container (Standard or High Cube)
R1 : Rack Mounted (Datacenter)
3333 Power in kW or kVA for AC systems, Current in A for DC
systems
0100 - 100 kW
1750 - 1750 kVA
0500 - 500 A
10M5 - 10500 kVA
4 Place of use
D : Indoor
H : Outdoor
5 Type of use
N : Normal, If there is a single entry
S : Selective, If there is more than one entry
(For example a single 200 A input at the load bank or 2x100 A
input if desired)
6 Control Type
0 : Without Control (Load Stages in Terminal Blocks)
1 : Controlled by manual circuit breakers or pako switches
2 : Manual button control (by contactors)
3 : Automatic HMI controlled (by PLC and Contactors)
4 : Automatic HMI and remote computer controlled
5 : Automatic ”Dummy load“ control
777 Voltage information in “Volt” for AC and DC systems
048 - 48 V
400 - 400 V
6K3 - 6,3 kV
88 Network information (1 Phase AC, 3 Phase AC or DC)
A1 : AC 1 Phase
A3 : AC 3 Phase
DC : DC
9 Air flow direction
H : Horizontal air flow
V : Vertical air flow
Examples:
1- LBR-03-0500HN3-400A3H
Description: 500 kW 3x400 VAC, horizontal airflow designed with enclosure number 3, single input, resistive, with automatic HMI
control, external type load bank
2- LBR-00-0250DS2-024DCV
Description: 2x125 A 24 VDC, vertical airflow designed with special sizes, two inputs, resistive, manual button control, internal
type load bank
B www.aktif.net
Switchgears and Substations
Metal Enclosed Switchgears
Metal Clad Switchgears
Mobile Substations White…
E-House / Compact Substations Color of the beginning…
White, color of the purity, honesty and clarity…
Power Resistors
Grounding Resistors Color of the stability and continuity, trust and quality…
Load Banks Since 2010, we decided to apply white color which symbolizes
Filter Resistors all of these values to all of our products.
Motor Control & Braking Resistors
Power Quality & Power Factor Correction
LV Capacitor & Filter Banks
MV Capacitor & Filter Banks
Capacitors & Harmonic Filter Reactors
Thyristor Switches
Medical Power & Control Panels
Operating Room Control Panels
Isolated Power Panel
Isolation Transformers
Automatic Transfer Relays
Smart Grid
Energy Management Systems
Metering & Submetering
Power Analyzers & Quality Recorders
Protection Devices
Traction Substation
Traction Rectifiers
DC Switchgears
DC Disconnectors
Traction Transformers
Renewable Energy & DC Conversion
High Power Rectifiers
Solar Inverters
Energy Storage Systems
EV Charging Stations
AGES - Grounding Transformers 20190201/Eng.
Group of Companies
Bayraktar Blv. Şehit sk. No: 5 Aktif Plaza Akşemsettin Mh. Çatalca sk. No:113 Pirahmetler mh. D-100 Yanyol cd.
34775 Ümraniye İstanbul / Turkey 06930 Sincan Ankara / Turkey No:78/A Erenler 54200 - Sakarya / Turkey
Tel : +90 (216) 314 93 20 Tel : +90 (312) 269 46 02 Tel : +90 (264) 276 64 50
Fax : +90 (216) 314 93 60 Fax : +90 (312) 269 45 01 Fax : +90 (264) 276 64 52
www.aktif.net - info@aktif.net www.aktif.net - info@aktif.net www.aktif.net - info@aktif.net