Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

jb^probjbkq=

ob`loa=
Service, Wärtsilä Finland Oy
Engine section Engine type Ref. Date Issue Document No. Page
11 Connecting rod tPO WFI–S 07.02.2006 04 3211V017 1(1)

Installation name: Engine type: Engine No:


Fuel viscosity (cSt): Ambient temp. (°C): Engine running hours:

Big end bearing bore


NOTE: The connecting rod shank and bearing housing must be
mounted together and the screws tightened before measuring.
Tighten the M27 screws in this order: First (1), then (2).
Hydraulic press. when tightening the M27 screws, to be tightened in two
steps: 400 bar and 800 bar.
Hydraulic pressure when loosening the M27 screws: 820 bar.

Nominal diameter without shells: (D)= 325 H6 ( + 0.036


0.000 ) mm
Allowed minimum diameter: 324.90 mm
Maximum allowed difference between Dmax and Dmin: 0.10 mm
Reference diameter (mm):

Gudgeon pin bearing bush mounted


Wear limit: When visible bronze lining wear areas meet, i.e. B = 0.
Wear pattern shown in view A–A.
Bank Cylinder number
1 2 3 4 5 6 7 8 9 10
Big end bearing bore D1 to D5 (deviation in 1/100 mm)

D1 L
R

D2 L
R

D3 L
R

D4 L
R

D5 L
R
Max. deviation
Con. rod running
hours bef. measuring
Remarks/Manufact. No.
(Stamped on Con. Rod)
Drawing No. or part No.
Gudgeon pin bearing bush mounted
Measurement (B) mm
Bush running hours
bef. measuring
Remarks/Manufact. No.

Date of measurement: Place: Name:

Wärtsilä Finland Oy P.O. Box 252 (Tarhaajantie 2) Telecop. +358 10 709 1847 Tel. +358 10 709 0000 Business ID 0773744-3
Service, Vaasa FIN-65101 Vaasa, Finland Telecop. +358 10 709 1380 Registered Office: Vaasa

Wärtsilä Finland Oy P.O. Box 50 (Stålarminkatu 45) Telecop. +358 10 709 3279 Tel. +358 10 709 0000
Service, Turku FIN-20811 Turku, Finland Telecop. +358 10 709 3410

You might also like