DSEGenset

DSE8660 ENVIRONMENTAL TESTING STANDARDS

ELECTRO MAGNETIC COMPATIBILITY


AUTO TRANSFER SWITCH & MAINS BS EN 61000-6-2
EMC Generic Immunity Standard for the

CONTROL MODULE Industrial Environment


BS EN 61000-6-4
EMC Generic Emission Standard for the
Industrial Environment
FEATURES ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment

TEMPERATURE
BS EN 60068-2-1
Ab/Ae Cold Test -30oC
The DSE8660 is an easy-to-use Comprehensive communications With all communication ports BS EN 60068-2-2
single or multi-mains controller with are also available via RS485 and capable of being active at the same Bb/Be Dry Heat +70oC
automatic transfer switch capability. RS232 for remote PC control and time, the DSE8600 Series is ideal VIBRATION
Designed to synchronise single or monitoring, and integration into for a wide variety of demanding BS EN 60068-2-6
multiple DSE8610s with single or building management systems. load share applications. Ten sweeps in each of three major axes
5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn
multiple mains (utility) supplies, the The comprehensive event log will
DSE8660 will automatically control record up to 250 events to facilitate KEY LOAD SHARE FEATURES: HUMIDITY
• Peak lopping BS EN 60068-2-30
the change over from mains (utility) maintenance. Db Damp Heat Cyclic 20/55oC @ 95% RH 48
to generator supply or run generators • Sequential set start Hours
in synchronisation with the mains An extensive number of fixed and • Manual voltage/frequency BS EN 60068-2-78
adjustment Cab Damp Heat Static 40oC @ 93% RH 48
(utility) to provide no-break, peak flexible monitoring and protection Hours
lopping and peak shaving power features are included. Easy • R.O.C.O.F. and vector shift
• Generator load demand SHOCK
solutions. alteration of the sequences, timers BS EN 60068-2-27
and alarms can be made using the • Automatic hours run balancing Three shocks in each of three major axes
The module can indicate DSE PC Configuration Suite • Mains (Utility) de-coupling 15gn in 11mS

operational status and fault Software. Selected configuration is • Mains (Utility) de-coupling
DEGREES OF PROTECTION
conditions on the LCD screen also available via the module’s front test mode PROVIDED BY ENCLOSURES
• Bus failure detection BS EN 60529
(multiple languages available), by panel. IP65 - Front of module when installed into the
illuminated LED, audible sounder • Volts and frequency matching. control panel with the supplied sealing gasket.
and SMS messaging.

COMPREHENSIVE FEATURE LIST TO SUIT A WIDE


VARIETY OF LOAD SHARE APPLICATIONS
MODEM MODBUS PC
DSE2130
DSE2157 11 6
DSE2548
232 485

DSENET ®
RS232 AND USB USB CONFIGURABLE DC OUTPUTS DC POWER
EXPANSION RS485 PORT HOST INPUTS SUPPLY 8-35V
+
ETHERNET

DSE8660 MSC

7
8610 ­8610 ­8660
OTHER

MAINS (UTILITY) SENSING N/C VOLT FREE N/O VOLT BUS


OUTPUTS FREE OUTPUT SENSING
CURRENT VOLTS

1ph 1ph 1 1 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N N N

ISSUE 2
®

DSEGenset

DSE8660 SPECIFICATION

DC SUPPLY
AUTO TRANSFER SWITCH & MAINS CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
CONTROL MODULE CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout
FEATURES and supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.

MAXIMUM OPERATING CURRENT


340 mA at 12 V, 160 mA at 24 V

MAXIMUM STANDBY CURRENT


160 mA at 12 V, 80 mA at 24 V

MAINS (UTILITY) AND BUS


VOLTAGE RANGE
15 V to 333 V AC (L-N)

FREQUENCY RANGE
3.5 Hz to 75 Hz

OUTPUTS
OUTPUTS C & D
8 A at 250 V AC (Volt free)

AUXILIARY OUTPUTS E,F,G,H, I & J


2 A DC at supply voltage

DIMENSIONS
OVERALL
240 mm x 181 mm x 42 mm
9.4” x 7.1” x 1.6”

PANEL CUT-OUT
220 mm x 160 mm
8.7” x 6.3”

MAXIMUM PANEL THICKNESS


8 mm
0.3”
KEY FEATURES • PIN protected front panel EXPANSION DEVICES
• Configurable inputs (11) configuration • DSE2548 LED Expansion Module
• Configurable outputs (8) • PC configuration • DSE2130 Input Expansion Module
• Voltage measurement • Configurable alarms and timers • DSE2157 Output Expansion
• Mains (utility) fail sensing • Configurable start and stop timers Module
• Multiple mains (utility) monitoring • SMS alert messaging • DSE124 CAN/MSC Extender
• Peak lopping
• Peak shaving KEY BENEFITS
• RS232 & RS485 remote • A single fexible solution for
communications multiple applications
• Modbus RTU • Ethernet monitoring
• Built-in PLC Functionality • Built-in RS232 & RS485 can be
• Multi event exercise timer used at the same time
• Back-lit LCD 4-line text display • DSENet connection for
• Multiple display languages system expansion
• Automatic start/Manual start • High number of inputs and outputs
• Audible alarm • Worldwide Language Support
• Fixed and flexible LED indicators • Configuration Suite PC Software
• Event log (250) via USB
• Fault condition notification to • USB Host*
a designated PC • Data Logging & Trending*
• Front panel mounting * To follow

RELATED MATERIALS
TITLE PART NO’S
DSE8660 Installation Instructions 053-070
DSE8660 Operator Manual 057-120
DSE8600 PC Configuration Suite Manual 057-119
DSE8610 Data Sheet 055-083

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-086/10/10 (2)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457

You might also like