Control Valve - Liquid flow 01/04/2006

Project 2670. . 2
Tag number 1LiqLoFlo By SWT
Input Data App hrh
Valve
Data : 25 mm Globe : Equal% contour. Ports : One. Flow to : Open
Rated Cv : 3.5. Orifice Dia : 12.5 mm

Pipe Sizes
Inlet : 100 mm. Outlet : 100 mm. Outlet pipe wall : 10.312 mm

Fluid Data
Name : Water
Maximum Normal Minimum Units
Percent of nominal flow 81 50 24
Liquid flow 1.62 1 .48 kg/s
Pressure drop 550.5 634.56 763.45 kPa
Flow temperature 146.11 146.11 139.22 degC
Inlet pressure 1691.2 1760.5 1843.6 kPag
Vapor pressure 431.07 431.07 355.62 kPaa
Critical pressure 22118 22118 22118 kPaa
Viscosity @ FTP 1.8854E-04 1.8854E-04 1.9872E-04 Pa.s
Specific gravity @ FTP .9189 .9189 .92511
Rated FL .95 .965 .98

Output Data
Required Cv 3.021 1.729 .7527
Percent of valve lift 86 49 22
Cavitation index 2.4732 2.2548 2.0818
Noise level 60 58 56 dbA
Flow status Normal Normal Normal
Cavitation or Flashing
Calculated FL .9541 .9652 .9757

Sizing pressure drop 550.5 634.56 763.45 kPa


SI mass units, basic calculation, calculate size
Source - ANSI/ISA-75.01.01-2012 Flow Equations for sizing control valves
Accuracy -
InstruCalc Ver.9.0.3.

Selection based on Masoneilan or equal Model 25100


Notes