GENERAL SITE PREPARATION AND FOUNDATIONS CONCRETE CONCRETE MASONRY

1. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH 1. STRIP TOP SOIL TO THE RELATIVE LEVELS SHOWN ON THE 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN 1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN
ALL OTHER CONSULTANTS' DRAWINGS AND ARCHITECTS DRAWINGS. THE EXPOSED AREA SHALL THEN ACCORDANCE WITH AS 3600-2009. ALL FORMWORK SHALL ACCORDANCE WITH AS 3700-2011.
SPECIFICATIONS. ALL DISCREPANCIES SHALL BE BE PROOF ROLLED TO ENSURE THAT NO LOCAL SOFT BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH 2. ALL CONCRETE MASONRY BLOCKS SHALL HAVE A
REFERRED TO THE DESIGNER/ENGINEER BEFORE SPOTS EXIST. AS 3610-1995. CHARACTERISTIC UNCONFINED COMPRESSIVE STRENGTH
PROCEEDING WITH THE WORK. 2. CONTROLLED FILL UNDER BUILDINGS SHALL CONSIST OF 2. MINIMUM COVER TO REINFORCEMENT TO BE AS FOLLOWS OF 15MPa.
2. ALL DIMENSIONS RELEVANT TO SETTING OUT AND SAND (WITH LESS THAN 15% RETAINED ON THE 75 MICRON U.N.O. ON THE DRAWINGS. 3. MORTAR FOR BLOCKWORK SHALL BE OF CLASSIFICATION
OFF-SITE WORK SHALL BE VERIFIED BY THE CONTRACTOR SIEVE) PLACED AND COMPACTED FOR ITS ENTIRE DEPTH FOOTINGS 50mm M3 ABOVE GROUND & M4 BELOW GROUND.
BEFORE CONSTRUCTION IS COMMENCED. THE ENGINEER'S TO A DENSITY INDEX OF MORE THAN 65% ACCORDING TO EXTERNAL GROUND SLABS 40mm 4. MINIMUM 28 DAY COMPRESSIVE STRENGTH OF
DRAWINGS SHALL NOT BE SCALED. AS 1289. ALTERNATIVELY, FOR FILL UP TO 800mm DEEP, A INTERNAL GROUND SLABS COREFILLING GROUT SHALL BE 20MPa, AND A SLUMP OF
3. DURING CONSTRUCTION, THE CONTRACTOR SHALL BE BLOW COUNT OF 7 OR MORE MAY BE SATISFACTORY WHEN - TOP COVER 30mm 230-/+ 25mm. AGGREGATE SIZE SHALL BE 10mm. GROUT
RESPONSIBLE FOR MAINTAINING THE STRUCTURE IN A TESTED IN-SITU WITH A PENETROMETER IN ACCORDANCE - BOTTOM COVER TO MEMBRANE 40mm SHALL HAVE A CEMENT CONTENT OF NOT LESS THAN
STABLE CONDITION AND ENSURING NO PART SHALL BE WITH AS 1289. 3. CONCRETE GRADE SHALL BE AS FOLLOWS: 300kg/m3.
OVERSTRESSED UNDER CONSTRUCTION ACTIVITIES. 3. TEST CERTIFICATES OF ACTUAL DENSITIES TO BE FOOTINGS N20 5. MINIMUM GROUT COVER TO ANY REINFORCEMENT SHALL
4. WORKMANSHIP AND MATERIALS ARE TO BE IN PROVIDED BY THE CONTRACTOR. INTERNAL SLAB N25 BE 20mm.
ACCORDANCE WITH THE RELEVANT AND CURRENT 4. THE CONTRACTOR SHALL CHECK ALL FOOTING EXTERNAL SLAB N25 6. NO CHASES SHALL BE CUT INTO BLOCKWORK WITHOUT
AUSTRALIAN STANDARDS INCLUDING ALL AMENDMENTS EXCAVATIONS FOR ORGANIC MATERIAL AND RUBBISH. IF 4. REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY THE APPROVAL OF THE ENGINEER.
AND STATUTORY REQUIREMENTS, EXCEPT WHERE VARIED ANY OF THIS MATERIAL IS FOUND, IT SHALL BE REMOVED AND NOT NECESSARILY SHOWN IN TRUE PROJECTION. 7. ALL WALL INTERSECTIONS SHALL BE BONDED
BY THE CONTRACT DOCUMENTS. AND THE EXCAVATION BACKFILLED WITH CLEAN 5. ALL REINFORCEMENT SHALL BE SUPPORTED IN ITS CONSTRUCTION.
5. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED GRANULAR FILL. CORRECT POSITION SO AS NOT TO BE DISPLACED DURING 8. SHORE RETAINING WALLS UNTIL CORE FILLING HAS CURED
OTHERWISE. 5. IF DISTURBED, THE BOTTOM OF THE EXCAVATIONS SHALL CONCRETING, ON APPROVED BAR CHAIRS AT 1000mm AND UNTIL FULLY SUPPORTED BY FLOOR FRAMING OVER
6. DESIGN WIND LOADS ARE IN ACCORDANCE WITH BE COMPACTED TO A RELATIVE DRY DENSITY OF 100% AS MAXIMUM CENTRES BOTH WAYS. WHERE REQUIRED WHERE APPLICABLE.
AS/NZS 4055 - 2012 AS FOLLOWS: DETERMINED IN ACCORDANCE WITH AS 1289.5.4.1-2007 AND PROVIDE SUPPORT BARS N16 AT 1000mm MAXIMUM
REGION: C AS 1289.5.1.1-2003. CENTRES.
STRUCTURAL TIMBER
TERRAIN CATEGORY 2 6. THE FOOTINGS HAVE BEEN DESIGNED TO BE FOUNDED IN 6. REINFORCEMENT SYMBOLS:-
SHIELDING CLASS NS A STABLE MATERIAL WITH A SAFE ALLOWABLE BEARING SL HARD DRAWN STEEL WIRE REINFORCING FABRIC 1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN
TOPOGRAPHIC FACTOR T0 CAPACITY OF 100kPa. SLABS HAVE BEEN DESIGNED TO BE TO AS/NZS 4671-2001.
ACCORDANCE WITH AS1720.1-2010 AND ALL OTHER
WIND CLASSIFICATION C2 FOUNDED ON MATERIAL WITH A MINIMUM CBR OF 5% OR N HOT ROLLED DEFORMED BARS TO AS/NZS RELEVANT CODES OF PRACTICE.
INTL PRESSURE COEFFICIENT +0.7/-0.65 BETTER. SHOULD CONDITIONS OTHER THAN THOSE 4671-2001.
2. ABNORMALLY GREEN OR SPLIT TIMBER SHALL BE REJECTED.
7. DESIGN LIVE LOADINGS ARE IN ACCORDANCE WITH DESCRIBED ABOVE BE ENCOUNTERED, THEN THE MATTER R STRUCTURAL GRADE PLAIN ROUND BAR TO
3. TIMBER AT JOINTS SHALL BE FREE OF DEFECTS.
AS/NZS 1170.1-2002 AS FOLLOWS: IS TO BE REFERRED TO THE ENGINEER FOR POSSIBLE AS/NZS 4671-2001.
4. UNLESS NOTED OTHERWISE, STRUCTURAL TIMBER SHALL BE
BALCONY 2.0kPa RE-DESIGN. W REINFORCED WIRE TO AS/NZS 4671-2001.
MGP12 OF JOINT GROUP JD4 TIMBER OR BETTER.
FLOOR 1.5kPa 7. IF CONCRETE IS PLACED IN HOT AND/OR WINDY WEATHER
5. IT SHALL BE THE RESPONSIBILITY OF THE BUILDER TO
ROOF 0.25kPa SITE DETAILS (>28°), AN ALIPHATIC FOG SPRAY IS RECOMMENDED TO
ENSURE THAT TIMBER IS PROTECTED FROM THE WEATHER
8. ALL ITEMS CALLED UP BY A TRADE NAME MAY BE REDUCE EVAPORATION.
AND STRENGTH IS NOT IMPAIRED IN ANY WAY.
SUBSTITUTED BY AN EQUIVALENT ITEM WITH SIMILAR CONFIRM THE FOLLOWING AND REFER ANY DISCREPANCIES TO 8. PIPES, CONDUITS AND OTHER CAST-IN ELEMENTS SHALL
6. THE TOLERANCE ON TIMBER ELEMENT DIMENSIONS SHALL
PROPERTIES, SUBJECT TO THE ENGINEER'S WRITTEN THE ENGINEER: BE POSITIONED TO ALLOW WET CONCRETE TO FLOW BE -0;+3mm.
APPROVAL. 1. REAL PROPERTY DESCRIPTION: AROUND ALL REINFORCEMENT. DO NOT TIE CONDUITS
7. ALL EXPOSED TIMBER SHALL BE OF DURABILITY CLASS 2 OR
LOT 01 ON RP1010. ALONGSIDE REINFORCEMENT. BETTER.
2. THE SITE HAS SOME FALL. 9. WELDING OR SITE BENDING OF REINFORCEMENT IS NOT 8. ALL BOLTS, SCREWS AND NAILS TO BE GALVANISED AND
3. THE SITE IS NOT SUBJECT TO EXISTING CONCENTRATED PERMITTED WITHOUT APPROVAL FROM THE INSTALLED IN ACCORDANCE WITH AS1720.1-2010.
OVERLAND FLOW. SUPERINTENDENT. 9. ALL NAIL AND SCREW PENETRATIONS NOMINATED ARE TO BE
4. NO TREES HAVE RECENTLY BEEN REMOVED FROM THIS 10. SLAB SURFACE AND EXPOSED SIDES SHALL BE CURED FOR INTO RECEIVING MEMBER.
SITE PRIOR TO CONSTRUCTION. A PERIOD OF AT LEAST 7 DAYS BY AN APPROVED METHOD 10. ALL PLYWOOD IS TO BE STAMPED “PAA TESTED
5. THERE ARE NO EXISTING TREES ON THIS OR ADJOINING OF CURING. (MOIST CURING, SPRAYED MEMBRANE OR STRUCTURAL”.
SITES LOCATED CLOSER TO THIS BUILDING THAN 1.5 TIMES IMPERMEABLE PLASTIC). 11. ALL BOLTS IN TIMBER TO TIMBER BOLTED STRUCTURAL
THEIR MATURE HEIGHT.
JOINTS SHALL BE PROVIDED WITH A WASHER AT EACH END
6. THE SITE HAS BEEN FILLED. THE FILL HAS BEEN PLACED IN
IN ACCORDANCE WITH AS1720.1-2010.
ACCORDANCE WITH ENGINEERING PRICIPLES AS
12. ALL BOLTS IN CONTACT WITH CCA PRESERVATIVE TREATED
CONFIRMED BY FIELD COMPACTION TESTING BY CARDNO
TIMBER SHALL BE COATED IN GREASE OR OTHERWISE
CONSTRUCTION SCIENCES.
INSULATED FROM THE PRESERVATIVE TREATED TIMBER
7. SITE CONDITIONS ARE CONTROLLED FILL OVERLYING
PRIOR TO ERECTION.
DENSE, NON-PLASTIC SILTY SAND OVERLYING HIGH PLASTIC
13. WHERE NO OTHER DETAILS ARE GIVEN, WORK SHALL
SANDY CLAY WITH AN ALLOWABLE BEARING CAPACITY OF
CONFORM TO AS1684.3-2010 FOR THE SPECIFIED WIND
MORE THAN 100kPa.
SPEED.
8. THERE ARE NO SEWER MAINS ADJACENT TO THE BUILDING.

ISSUED FOR
CONSTRUCTION
Project Job No. Scale
PO BOX 2572
ASCOT QLD 4007 PROPOSED DISPLAY HOME SAMPLE NTS
PHONE: 07 3102 2835
----
Title Drawing No. Revision
ABN 71 105 354 327
PROJECT SPECIFIC NOTES S1
0 FOR CONSTRUCTION
Rev Description
MAC MAC
Designed Approved
21/03/13
Date
CORNELLENGINEERS.COM.AU 0