3FE-64746-AAAA-TQZZA-02-NANT-E Unit Data Sheet

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Combined NT Unit version E NANT-E

1 Identification -2

2 Introduction -2

3 Features and Application Notes -2

4 General Description -3

5 Functional Description -4

6 External Interfaces -6

7 Alarm Control Unit -8

8 Physical Description -9

9 Power Supply -11

3FE 64746 AAAA TQZZA Ed 02 Released 1 / 12


NANT-E Combined NT Unit version E

1 Identification

Table 1 provides identification of the NANT-E

Table 1: Identification of the NANT-E

Part Number Mnemonic Name

3FE 64746 AA NANT-E Combined NT Unit version E

2 Introduction

This document describes the Combined NT Unit version E (NANT-E) which is part of
the 7302 Intelligent Services Access Manager (7302 ISAM) and the 7330 Intelligent
Services Access Manager Fiber to the Node (7330 ISAM FTTN).

3 Features and Application Notes

The NANT-E:
• Can be used in a 7302 ISAM Flexible Density (FD) subrack and a 7330 ISAM FTTN
FD subrack.
• Performs all management and alarm handling functions for the ISAM subrack and all
the client devices mounted in the subrack or connected to the subrack, and supports
the management and control interfaces required for this task.
These client devices are:
• for a 7302 ISAM FD subrack: the LT boards
• for a 7330 ISAM FTTN FD subrack: a combination of LT boards, SB-REM units, and/
or FD-SEM units.
• Has four SFP+ 10Gigabit Ethernet (10GE) interfaces
The SFP+ interfaces support 1 GE, 2.5 GE and 10 GE data rates.
• Has one 10/100/1000BASE-T interface
• Supports up to 128 K MAC address entries with hardware assisted aging.
• Supports NT I/O.
• Can be used in the following operational conditions:
• in Central Office (CO) environment with multiple 7302 FD subracks, the ambient
temperature can be between -5 °C to +45 °C
• in a single 7302 FD subrack or a single 7330 FD subrack, the ambient temperature can
be between -40 °C to +70 °C
• Consists of components which are compliant to the regulations of Reduction of
Hazardous Substances (RoHS) and Waste Electrical and Electronic Equipment
(WEEE).
• Is compliant to safety standards IEC / EN 60950-1 and AS/NZS 60950-1, provided
that it is installed, maintained and used according the relevant installation instructions.

3FE 64746 AAAA TQZZA Ed 02 Released 2 / 12


Combined NT Unit version E NANT-E

4 General Description

The NANT-E NT board is responsible for:


• the routing/switching and the aggregation of end-user data streams to and from
network interfaces and/or uplink interfaces.
• all the management and alarm handling functions for:
• the ISAM subrack itself
• all the client devices in the ISAM subrack or connected to the ISAM subrack
• System clock generation
• supports a cut-through mode for the system clock, i.e. it can receive and relay the
system clock (generated by another BITS/SyncE capable NT).
• Centralized shelf alarm handling and reporting (Alarm Control Unit (ACU)
functionality).

The LT boards are responsible for the physical termination of user interfaces and non-
blocking user aggregation.
The NANT-E board must be used at the NT-A and/or the NT-B position of the ISAM
FD subrack. Figure 1 shows the position of the NANT-E in the ISAM system.

Fig. 1: Position of the NANT-E in the system


Alarm interfaces

Management-A
interface
LT #0
ACU

LT #1
NT-A
(NANT-E)
User interfces
Uplink/Network

(N x DSL)
Interfaces

NTIO

LT #N-1
NT-B
(NANT-E) LT #N

ACU

Management-B
interface ISAM system

3FE 64746 AAAA TQZZA Ed 02 Released 3 / 12


NANT-E Combined NT Unit version E

5 Functional Description

Figure 2 shows the different functional blocks of the NANT-E.

Fig. 2: Functional Blocks of the NANT-E

PBA-NANT-E
FIM BIM
System Clock Interface REFIN REFOUT Reference Output Clock
8kHz-Interface MCSD LT Reference Clocks
19.44MHz-Interface REFOUT
PNTIN Peer NT Reference Input Clock

NT Alarm-Cut-Off LED ACOLED ALMOUT Alarm Control Outputs


NT Alarm-Cut-Off-Switch
ACU
ACOSW ALMIN Alarm Status Inputs

NT Front SystemLEDs SYSLED HIPC NT-NT Communication Itf


Local Craft Interface LCMI SOI NT-NT Switch-Over Itf
SLI NT Special Lines Itf
CISC SIO NT Serial I/O Itf
SAS NT Active-Standby Itf
NT Front Uplink LEDs UPLED BSM NT Backplane (NTIO)
Serial Management Itf

NT Front Uplink Interface #0 FUI#0 LT0 LT SerdesItf#0

LT15 LT SerdesItf#15
NT Front Uplink Interface #3 LT17 LT SerdesItf#17
10/100/1000 BASE-T interface FUI#4 BUI0 Backplane Uplink Itf#0

NUTS BUI4 Backplane Uplink Itf#4


BUI5/LT16 Backplane Uplink Itf#5/LT SerdesItf#16
BUI6 Backplane Uplink Itf#6
BUI7 Backplane Uplink Itf#7

NNLS NT-NT Load-Sharing Itf

NTIO/NTAP-Powering Itf
PSIM NT Power Supply Itf
SMAS-Powering Itf

The different functional blocks are:


• CISC:
The Centralized ISAM System Controller (CISC) Implements all On-Board
Controller (OBC) functions which accommodate a centralized Control and
Management approach of the complete ISAM shelf and provides the necessary
processing capabilities for Ethernet packets/frames forwarded to the main OBC from
the GE switching module.
• MCSD:
The Master Clock Synchronization and Distribution (MSCD) provides the following
functionality:
• System Network Timing Reference (NTR).
• Synchronization Output reference clocks towards:
- The shelf-based LT boards (backplane connections): 8 kHz.
- The internal NTR signal from the active NT board to the standby NT board in
a redundant NT board pair (backplane connection): 8 kHz.
- The external NTR daisy-chain interface (located at the NT board front): 8 kHz.

3FE 64746 AAAA TQZZA Ed 02 Released 4 / 12


Combined NT Unit version E NANT-E

• ACU:
The Alarm Control Unit (ACU) provides all the necessary alarm control and interface
circuitry for accumulating system alarms, driving relay contacts for alarm outputs
and provisioning visual alarm indications.
• NUTS:
The Network/User Transport and Switching (NUTS) provides the interface and
switching circuitry for the front and back related uplink/network interfaces to/from
the LT slots.
• PSIM:
The Power Supply Interface Module (PSIM) converts the rack power supply into all
necessary voltages as required by the used components.
• FIM:
The Frontplate Interface Module (FIM) located at the front stiffener holds the
physical interfaces (four SFP+, one 10/100/1000Base-T interface) together with a
visual port status indication. The FIM also hosts a Management Interface (CRAFT)
together with the ACO functionality.
• BIM:
The Backplane Interface Module (BIM) constitutes all the necessary control,
management, and data plane related interface inside the complete ISAM system.

3FE 64746 AAAA TQZZA Ed 02 Released 5 / 12


NANT-E Combined NT Unit version E

6 External Interfaces

The following external interfaces are accessible via the front panel:

Communication Interfaces
5 communication interfaces are available via the front panel:
• 1 x fixed 10/100/1000BaseT port
This port can work both in 10Mbit, 100Mbit or 1GE mode.
Note: a shielded Ethernet cable must be used to connect this interface.
• 4 x 10GE SFP+ port:
This port can work both in 1 GE mode (with standard SFP optics), in 2.5 GE mode
and in 10 GE mode (with SFP+ optics).

Management Interfaces
The following management interfaces are available via the front panel:
• Local Craft Management interface (LCMI) (RJ45 connector)
• An Alarm Cut-Off Switch (ACOS) and LED (ACOLED)
Note: any of the five communication interfaces can also be used as management interface.
The following Daisy Chain (DC) interfaces are available via the front panel:
• DC input interface (RJ45 connector named “BITS IN”)
• DC output interface (RJ45 connector named “BITS OUT”)
Note: In the standard configuration, the daisy chain capability is mapped onto the 8kHz
clock.

Daisy Chain Interface


The DC IN/OUT interfaces are mapped to two physical RJ45 connectors.

Fig. 3: RJ45 Connector

8 1

Table 2 shows the signals of the DC IN connector.

3FE 64746 AAAA TQZZA Ed 02 Released 6 / 12


Combined NT Unit version E NANT-E

Table 2: DC IN Signals

Signal Name Description Type RJ45 Pin Technology

DC-IN-8k_T/F Daisy-Chain 8KHz Timing Reference I 5/6 LVPECL


Input Clock
(Differential pair 100 Ω, LVPECL)

DC-IN-19M_T/F Daisy-Chain 19.44MHz Timing I 7/8 LVPECL


Reference Input Clock
(Differential pair 100 Ω, LVPECL)

FG_ESD_EMC Frame Ground Ref 1, 4 and Ref


CASE

Table 3 shows the signals of the DC OUT connector.

Table 3: DC OUT Signals

Signal Name Description Type RJ45 Pin Technology

DC-OUT-8k_T/F Daisy-Chain 8KHz Timing Reference O 5/6 LVPECL


Output Clock
(Differential pair 100 Ω, LVPECL)

DC-OUT-19M_T/F Daisy-Chain 19.44MHz Timing O 7/8 LVPECL


Reference Output Clock
(Differential pair 100 Ω, LVPECL)

FG_ESD_EMC Frame Ground Ref 1, 4 and Ref


CASE

Craft Interface
The Craft cable connector is a male RJ45 connector.

Fig. 4: RJ45 Connector

8 1

Table 4 shows the connector pinning (both RJ45 and DB9) for the Craft cable connector.

Table 4: Craft Cable Connector

Signal Name Type RJ45 DB9 Description


Pin Nr. Pin Nr.
DCD O 2 1 “Data Carrier Detect”

RXD O 5 2 Craft interface receive data

(1 of 2)

3FE 64746 AAAA TQZZA Ed 02 Released 7 / 12


NANT-E Combined NT Unit version E

Signal Name Type RJ45 DB9 Description


Pin Nr. Pin Nr.

TXD I 6 3 Craft interface transmit data

DTR I 3 4 “Data Terminal Ready”

EG Ref 4 5 Electrical Ground or “Signal Ground”

- - 8 - -

CTS O 7 8 “Clear To Send”

RI, DSR O 1 9 “Ringing Indicator” and “Data Set Ready”

(2 of 2)

7 Alarm Control Unit

The Alarm Control Unit (ACU) provides:


• a central point for internal (= subrack related) alarm collection.
• a central point for external (= CO related) alarm collection and control.
• the necessary circuitry for rack alarm control and visualization.
• an Alarm Cut Off (ACO) capability to the subrack.

The following ACU functionality is provided:


• Fan unit alarm interface (2 inputs)
• Central Office alarm interface (5 miscellaneous inputs)
• Circuit breaker alarm (1 input)
• Door alarm (1 input)
• Subrack alarm lamp interface
• Miscellaneous output alarm (2 interfaces)

These ACU interfaces can be found on the backplane of the subrack, for more
information refer to the FD Hardware Installation Manual.

3FE 64746 AAAA TQZZA Ed 02 Released 8 / 12


Combined NT Unit version E NANT-E

8 Physical Description

Figure 5 shows the side and front view of the NANT-E.

Fig. 5: View of the NANT-E

BITS_OUT
BITS_IN
CRAFT

10/100/1000
BASE-T
interface

SFP+
interfaces

Dimensions:
The dimensions of the NANT-E are:
• Height: 405 mm
• Width: 30 mm
• Depth: 205/225 mm

System Status LEDS


Figure 6 shows the system status LEDS of the NANT-E.

3FE 64746 AAAA TQZZA Ed 02 Released 9 / 12


NANT-E Combined NT Unit version E

Fig. 6: System Status LEDs

PWR

A/S

ALM

ACO

Table 5 gives the definitions of the system status LEDS on the NANT-E.

Table 5: System Status LED Definition

Port Description
PWR • Green - Power present
• Off - No power
A/S • Green - Active
• Off - Stand-by
ALM • Red - Alarm condition exists
• Off - No alarm condition exists
ACO • Green - Alarm has been cut off
• Off - No alarm cut off

Port LEDs
Figure 7 shows the port LEDS of the NANT-E.
Fig. 7: Port LEDs

X1

X2

X3

X4

Each SFP port has a respective single LED associated with it to visualize the link and
activity status.
Table 6 gives the definitions of the port LEDS on the NANT-E.

3FE 64746 AAAA TQZZA Ed 02 Released 10 / 12


Combined NT Unit version E NANT-E

Table 6: Port LED Definition

Port Description

SFP Ports LED Link / Active LED


• Green - link up at this port
• Blinking green - transmitting or receiving packet in link up state
• Off - No link detected at this port

Alarm Cut Off


The NANT-E is equipped with an Alarm Cut Off switch and an Alarm Cut Off indication
LED (refer to Figure 6).

9 Power Supply

The NANT-E is compatible with -48 Vdc nominal and -60 Vdc nominal power supply
systems.
Note: Country dependent tolerances exist regarding the nominal battery voltage values.

3FE 64746 AAAA TQZZA Ed 02 Released 11 / 12


NANT-E Combined NT Unit version E

3FE 64746 AAAA TQZZA Ed 02 Released 12 / 12