Professional Documents
Culture Documents
Used Engine Oil Samples Analysis: Result Sample No1 Test
Used Engine Oil Samples Analysis: Result Sample No1 Test
Result
Test
Sample No1
Flash Point by
Pensky-Martens
206
Closed Cup Tester
ASTM 93
Flash Point by
Pensky-Martens
224
Opened Cup Tester
ASTM 93
Kinematic Viscosity
@ 100˚C 17.11
ASTM 445
Acid Number
by Potentiometric
4.74
Titration
ASTM 664
Base Number by
Potentiometric
6.51
Titration
ASTM 4739
Insolubles in Used
Lubricating Oils 0.40
ASTM 893 Pentane
Insolubles in Used
Lubricating Oils 0.15
ASTM 893 Toluene
Water in Petroleum
Products by
traces
Distillation
ASTM 95
Metal Fe 13.5
content
ppm Cu 3
Sample description
Sample No1
Site code Shike zaied
Site name
Applied oil Mobil delvac
Running hours 432