Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Project: Tai Wai Station Property Development

WAH 華東幕牆工程有限公司 in STTL No. 520


Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 26

Section properties
---------------- REGIONS ----------------
100

Area: 1873.1748
5 Perimeter: 738.5398
Bounding box: X: -50.0000 -- 50.0000
Y: -50.0000 -- 50.0000
Centroid: X: 0.0000
100

Y: 0.0000
Moments of inertia: X: 2794323.2746
Y: 2794323.2746
Product of inertia: XY: 0.0000
Radii of gyration: X: 38.6233
Y: 38.6233
Principal moments and X-Y directions about centroid:
I: 2794323.2746 along [1.0000 0.0000]
J: 2794323.2746 along [0.0000 1.0000]
Area = 1873.2 mm2
Ixx = 2794323.3 mm4
Iyy = 2794323.3 mm4
Zxx = 55886.5 mm3
Zyy = 55886.5 mm3
Rx = 38.6 mm
Ry = 38.6 mm

* Check for section capacity

About x-x axis / y-y aixs

e = (275 / 275)^0.5
= 1

b / T = (100 - 3 x 5) / 5
= 17 < 28e Plastic

d / t = (100 - 3 x 5) / 5
= 17 < 64e Plastic

ie. The section is plastic about x-x axis / y-y axis


Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 27

* Check for bending

Max. factored bending moment due to wind,


Mw = 1.4 x (w1 x (3L^2 - 4a^2) / 24 + w2 x L^2 / 8)
= 1.4 x (2.3 x (3 x 2200.0^2 - 4 x 650.0^2)/ 24 + 4.4 x 2200.0^2 / 8)

= 5494805.3 Nmm

Bending moment capacity, Mwc = 1.2 x py x Zyy


= 1.2 x 275 x 55886.5
= 18442533.6 Nmm > Mw = 5494805.3Nmm OK

Max. factored bending moment due to dead,


Md = 1.4 x Fd x (L / 4)
= 1.4 x 881.8 x (2200.0 / 4)
= 679005.2 Nmm

Bending moment capacity, Mdc = 1.2 x py x Zxx


= 1.2 x 275 x 55886.5
= 18442533.6 Nmm > Md = 679005.2Nmm OK

Combine bending, = Mw / Mwc + Md / Mdc


= 5494805.3 / 18442533.6 + 679005.2 / 18442533.6
= 0.33 < 1 OK

* Check for shear

Max. factored shear force due to wind,


Fvw = 1.4 x (w1 x (L -a) / 2 + w2 x L / 2)
= 1.4 x (2.3 x (2200.0 - 650.0) / 2 + 4.4 x 2200.0 / 2)
= 9353.2 N

Max. factored shear force due to dead,


Fvd = 1.4 x Fd
= 1.4 x 881.8
= 1234.6 N

Max. factored resultant shear force, Fvr = (Fvw^2 + Fvd^2)^0.5


= (9353.2^2 + 1234.6^2)^0.5
= 9434.3 N

Shear capacity, Fvc = py x Area / 3^0.5


= 275 x 1873.2 / 3^0.5
= 297406.4 N > Fvr = 9434.3N OK
Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 28

* Check for deflection

Max. deflection due to wind, dw = w1 x (5 x L^2 - 4 x a^2)^2 / (1920 x E x Iyy) + 5 x w2 x L^4 /


(384 x E x Iyy)

= 2.3 x (5 x 2200.0^2 - 4 x 650.0^2)^2 / (1920 x 205000 x


2794323.3) + 5 x 4.4 x x 2200.0^4 / (384 x 205000 x
2794323.3)

= 3.4 mm

Max. deflection due to dead, dd = Fd x (L / 4 ) x (3 x L^2 - 4 x (L / 4)^2) / (24 x E x Ixx)


= 881.8 x (2200.0 / 4) x (3 x 2200.0^2 - 4 x (2200.0 / 4)^2) / (24 x 205000 x
2794323.3)

= 0.5 mm

Max. total deflection, dt = (dw^2 + dd^2)^0.5


= (3.4^2 + 0.5^2)^0.5
= 3.5 mm

Limiting deflection, = L / 200


= 2200.0 / 200
= 11.0 mm > dt = 3.5mm OK
Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 29

4.4 Check for 100 x 100 x 5mm thk. GMS SHS transom (M2)
(Refer to drawing no. E01, detail 1)

Loading
Span, L= 2200 mm
Basic wind pressure, P= 2.45 kPa
Coefficient of wind pressure, cp = 1.4
Design wind pressure, Pd = P x cp
= 2.45 x 1.4
= 3.43 kPa
Wind load width, W= 1100 mm (2200 / 2)
Wind udl, w= Pd x W / 1000
= 3.4 x 1100.0 / 1000
= 3.8 N/mm

Wind load from feature, wf = P x 2 x 0.2m


= 2.45 x 2 x 0.2m
= 1.0 N/mm

Dead load, Fd = (2650kg/m^3 x 0.019m x 2.2m x 2.175m (glass panel)


+ 7850kg/m^3 x 0.001874m^2 x 2.2m (GMS transom))
/2
= 136.6 kg
= 1366.4 N
Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 30

Section properties
---------------- REGIONS ----------------
100

Area: 1873.1748
5 Perimeter: 738.5398
Bounding box: X: -50.0000 -- 50.0000
Y: -50.0000 -- 50.0000
Centroid: X: 0.0000
100

Y: 0.0000
Moments of inertia: X: 2794323.2746
Y: 2794323.2746
Product of inertia: XY: 0.0000
Radii of gyration: X: 38.6233
Y: 38.6233
Principal moments and X-Y directions about centroid:
I: 2794323.2746 along [1.0000 0.0000]
J: 2794323.2746 along [0.0000 1.0000]

Area = 1873.2 mm2


Ixx = 2794323.3 mm4
Iyy = 2794323.3 mm4
Zxx = 55886.5 mm3
Zyy = 55886.5 mm3
Rx = 38.6 mm
Ry = 38.6 mm

* Check for section capacity

About x-x axis / y-y axis

e = (275 / 275)^0.5
= 1

b / T = (100 - 3 x 5) / 5
= 17 < 28e Plastic

d / t = (100 - 3 x 5) / 5
= 17 < 64e Plastic

ie. The section is plastic about x-x axis


Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 31

* Check for bending

Max. factored bending moment due to wind,


Mw = 1.4 x w1 x (3L^2 - 4a^2) / 24
= 1.4 x 3.8 x (3 x 2200.0^2 - 4 x 1100.0^2)/ 24

= 2130487.3 Nmm

Bending moment capacity, Mwc = 1.2 x py x Zyy


= 1.2 x 275 x 55886.5
= 18442533.6 Nmm > Mw = 2130487.3Nmm OK

Max. factored bending moment due to dead & feature,


Md = 1.4 x Fd x (L / 4) + 1.4 x wf x L^2 / 8
= 1.4 x 1366.4 x (2200.0 / 4) + 1.4 x 1.0 x 2200.0^2 / 8
= 1882221.6 Nmm

Bending moment capacity, Mdc = 1.2 x py x Zxx


= 1.2 x 275 x 55886.5
= 18442533.6 Nmm > Md = 1882221.6Nmm OK

Combine bending, = Mw / Mwc + Md / Mdc


= 2130487.3 / 18442533.6 + 1882221.6 / 18442533.6
= 0.22 < 1 OK

* Check for shear

Max. factored shear force due to wind,


Fvw = 1.4 x w1 x (L -a) / 2
= 1.4 x 3.8 x (2200.0 - 1100.0) / 2
= 2905.2 N

Max. factored shear force due to dead & feature,


Fvd = 1.4 x Fd + 1.4 x wf x L / 2
= 1.4 x 1366.4 + 1.4 x 1.0 x 2200.0 / 2
= 3422.2 N

Max. factored resultant shear force, Fvr = (Fvw^2 + Fvd^2)^0.5


= (2905.2^2 + 3422.2^2)^0.5
= 4489.1 N

Shear capacity, Fvc = py x Area / 3^0.5


= 275 x 1873.2 / 3^0.5
= 297405.7 N > Fvr = 4489.1N OK

You might also like