: Design  Sun 
C  26‐05‐2020  Issued for review Song Linquan Huo Meng 
Document  Defeng 
Design  Sun 
B  13‐04‐2020  Issued for review Song Linquan Huo Meng 
Document  Defeng 
Design  Sun 
A  13‐01‐2020  Issued for review Song Linquan Huo Meng 
Document  Defeng 

Rev.  Date  Section  Rev. Particular  Compiled by Review  Approval

 
LIST OF HVAC EQUIPMENT
IN THE PLANT
暖通设备清册
 
 
Document No.  KEPPT‐RUPP‐0‐SDEP‐SAK‐DHV‐0002 

PROJECT  AL‐Rumailah Combined Cycle 730MW Power Plant Project 

OWNER  KAR Electrical Power Production Trading FZE 

 
EPC CONTRACTOR  Sinohydro Corporation Limited 

 
Index No. 37-FA17531S-N0102-01
Rev. C
 
 
AL‐ RUMAILAH COMBINED CYCLE 730MW POWER PLANT PROJECT      DETAILED DESIGN 
伊 拉 克 鲁 迈 拉 7 3 0 M W 联 合 循 环 电 站 项 目     施 工 图 设 计 
 

HVAC Volume 1 Section 2


暖通部分 第 1 卷 第 2 册

LIST OF HVAC EQUIPMENT


IN THE PLANT
暖通设备清册
 
 
PROJECT
KEPPT-RUPP-0-SDEP-SAK-DHV-0002 
DRAWING No.
DESIGN: Shandong Electric Power Engineering
Consulting Corporation Ltd.
 
山东电力工程咨询院有限公司 
Date: May 26, 2020
 
 
 
SHANDONG ELECTRIC POWER ENGINEERING CONSULTING COMPANY, LTD.
COVER SHEET
山东电力工程咨询院有限公司文件签署页 
REVISION
INDEX NO. KEPPT-RUPP-0-SDEP-SAK-DHV-0002 NO. C 
检索号  37-FA17531S-N0102-01 
版次 
TITLE LIST OF HVAC EQUIPMENT IN THE PLANT PAGE
 
文件名  暖通设备清册 页数 
ATTACHMENT
PAGE
S    
页数 
附件 
COPYRIGHT STATEMENT
版权声明 
THE COPYRIGHT OF THIS DOCUMENT IS OWNED BY SDEPCI AND TO BE
USED SOLELY FOR THIS PROJECT.
THE DOCUMENT AND RELATIVE INFORMATION IS NOT TO BE
TRANSMITTED, DISCLOSED TO THE THIRD PARTY OR USED FOR OTHER
PROJECTS WITHOUT AUTHORIZATION OF SDEPCI.
本文件版权归山东电力工程咨询院有限公司所有,仅限于本项目使用。未经我公司
授权,禁止向第三方传递、披露或在其他项目中使用。 
ORIGINATOR
 
编 制 
CHECKED
 
校 核 

COUNTERSIGN
会签   

REVIEWER
 
审核 
APPROVED
批准   
DESCRIPTION
说明

1、THIS VOLUME CONTAINS THE HVAC EQUIPMENT LIST DESIGNED BY SDEPCI.


本卷册包含山东院设计范围内暖通设备清册。
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
N0201 #1 VENTILATION FOR TURBINE HOUSE
(1)
N0201 #1 汽机房全面通风 KEPPT-RUPP-0-SDEP-SAM-DHV-0000
3
EVAPORATIVE ZKX30 TYPE, L=32000m /h
10SAM11AH401~408 SET GUANGDONG SHENLING ENVIRONMENT SYSTEM CO., LTD.
1 COOLING UNIT H=150Pa, 13
10SAM21AH401~405 台 广东申菱环境系统股份有限公司
蒸发冷却机组 MOTOR:400V/230V, N=16.3kW
3
EXPLOSION-PROOF L=58500m /h,H=169Pa
SET DEZHOU GUOYANG ENVIRONMENTAL PROTECTION EQUIPMENT CO.,LTD.
2 ROOF FAN 10SAM30AN001~AN006 BWT-NO.14, n=480r/min, 6
台 德州国阳电力环保设备有限公司
防爆屋顶风机 MOTOR:400V, N=4.0kW
N0201 #2 VENTILATION FOR TURBINE HOUSE
(2)
N0201 #2 汽机房全面通风 KEPPT-RUPP-0-SDEP-SAM-DHV-0000
3
EVAPORATIVE ZKX30 TYPE, L=32000m /h
20SAM11AH401~409 SET GUANGDONG SHENLING ENVIRONMENT SYSTEM CO., LTD.
3 COOLING UNIT H=150Pa, 13
20SAM21AH401~404 台 广东申菱环境系统股份有限公司
蒸发冷却机组 MOTOR:400V/230V, N=16.3kW
3
EXPLOSION-PROOF L=58500m /h,H=169Pa
SET DEZHOU GUOYANG ENVIRONMENTAL PROTECTION EQUIPMENT CO.,LTD.
4 ROOF FAN 20SAM30AN001~AN006 BWT-NO.14, n=480r/min, 6
台 德州国阳电力环保设备有限公司
防爆屋顶风机 MOTOR:400V, N=4.0kW
N0202 #1 VENTILATION AND AIR CONDITIONING FOR ELECTRICAL ROOMS OF MAIN POWER BUILDING
(3)
N0202 #1 汽机房电气房间通风空调 KEPPT-RUPP-0-SDEP-SAM-DHV-0100
TUBULAR
3
VENTILATING FAN L=400m /h, H=160Pa SET CONNECTED ∅150
5 10SAM10AN005、006 2
天花板管道式换气 230V, N=0.044kW 台 接管尺寸∅150

STEEL AXIAL #2.8, α=25°, n=1450r/min
3 SET FLANGE FOR INLET GRAVITY LOUVER FOR OUTLET
6 EXHAUST FAN 10SAM10AN002 L=1346m /h, H=44Pa 1
台 进风侧配法兰,出风侧配自垂百叶
钢制轴流排风机 400V, N=0.025kW
STEEL AXIAL #3.55, α=25°, n=1450r/min 1 AIR COLLECTOR AND STEEL MESH FOR INLET, 1 FLANGE FOR INLET,
3 SET
7 EXHAUST FAN 10SAM10AN004、007 L=2737m /h, H=70Pa 2 GRAVITY LOUVER FOR OUTLET

钢制轴流排风机 400V, N=0.09kW 1 台进风侧配集流器和钢丝网,1 台进风侧配法兰,出风侧配自垂百叶

-1-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
STEEL
EXPLOSION-PROOF #4.0, α=25°, n=1450r/min
3 SET
8 AXIAL EXHAUST FAN 10SAM10AN001 L=3920m /h, H=88Pa 1

钢制防爆轴流排风 400V, N=0.12kW

STEEL AXIAL #4.5, α=20°, n=1450r/min
3 SET
9 EXHAUST FAN 10SAM20AN002 L=4504m /h, H=110Pa 1

钢制轴流排风机 400V, N=0.18kW
STEEL AXIAL #4.5, α=35°, n=1450r/min
3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
10 EXHAUST FAN 10SAM20AN003 L=6658m /h, H=150Pa 1
台 进风侧配法兰,出风侧配自垂百叶
钢制轴流排风机 400V, N=0.37kW
STEEL AXIAL #5.0, α=25°, n=1450r/min
3 SET
11 EXHAUST FAN 10SAM20AN001 L=7655m /h, H=138Pa 1

钢制轴流排风机 400V, N=0.37kW
FRP
CORROSION-PROOF #5.0, α=30°, n=1450r/min
3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
12 AXIAL EXHAUST FAN 10SAM10AN003 L=8327m /h, H=149Pa 1
台 进风侧配集流器和钢丝网,出风侧配自垂百叶
玻璃钢防腐轴流排 400V, N=0.55kW
风机
STEEL AXIAL #5.6, α=25°, n=1450r/min
3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
13 EXHAUST FAN 10SAM20AN004 L=10379m /h, H=174Pa 1
台 进风侧配法兰,出风侧配自垂百叶
钢制轴流排风机 400V, N=0.75kW
LENGTH OF REFRIGERATING PIPE 20m CONDENSATE PIPE 3m,
1*100% FLOOR
室内外机制冷剂管单程接管长度 20m,冷凝水管长度 3m
MOUNTED PACKAGED COOLING CAPACITY, QL=59.0kW
3 SET THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
14 AIR CONDITIONER 10SAM10AH405 L=10000m /h 1
台 制冷剂管道为铜管
1*100% 风冷柜式 N=24.36kW, 400V/230V
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
空调机
冷凝水管材料为 PVC 塑料管

-2-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
2*100%
EXPLOSION-PROOF
CABINET AIR GL2.0, QL=9.0kW, QR=7.5kW SET
15 10SAM10AH401、402 3 2 N=0.55kW, 400V/230V
HANDLING UNIT L=2000m /h, H=100Pa 台
2*100% 防爆立柜
式空气处理机组
2*100% CABINET
AIR
GL3.0, QL=12kW, QR=6.0kW SET
16 HANDLING UNIT 10SAM10AH403、404 3 2 N=0.55kW, 400V/230V
L=3000m /h, H=100Pa 台
2*100%立柜式空气
处理机组
2*100% CABINET
AIR
GL10.0, QL=50kW SET
17 HANDLING UNIT 10SAM20AH403、404 3 2 N=3.0kW, 400V/230V
L=10000m /h, H=200Pa 台
2*100% 立柜式空
气处理机组
1*100% CABINET
AIR
GL10.0, QL=50kW SET
18 HANDLING UNIT 10SAM10AH406 3 1 N=3.0kW, 400V/230V
L=10000m /h, H=200Pa 台
1*100%立柜式空气
处理机组
2*100% CABINET
AIR
GL12.0, QL=56kW SET
19 HANDLING UNIT 10SAM20AH401、402 3 2 N=4.0kW, 400V/230V
L=12000m /h, H=200Pa 台
2*100% 立柜式空
气处理机组

-3-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
2*100% COMBINED
CONSTANT
TEMPERATURE L=19000m /h, QL=72kW3
SET N=8.0kW+20kW
20 AND HUMIDITY AIR 10SAM20AH405、406 QR=20kW, △H=350Pa 2
台 400V/230V
HANDLING UNITS Humidifying capacity 10kg/h
2*100%组合式恒温
恒湿空气处理机组
N0202 #2 VENTILATION AND AIR CONDITIONING FOR ELECTRICAL ROOMS OF MAIN POWER BUILDING
(4)
N0202 #2 汽机房电气房间通风空调 KEPPT-RUPP-0-SDEP-SAM-DHV-0100
TUBULAR
3
VENTILATING FAN L=400m /h, H=160Pa SET CONNECTED ∅150
21 20SAM10AN005、006 2
天花板管道式换气 230V, N=0.044kW 台 接管尺寸∅150

STEEL AXIAL #2.8, α=25°, n=1450r/min
3 SET FLANGE FOR INLET GRAVITY LOUVER FOR OUTLET
22 EXHAUST FAN 20SAM10AN002 L=1346m /h, H=44Pa 1
台 进风侧配法兰,出风侧配自垂百叶
钢制轴流排风机 400V, N=0.025kW
STEEL AXIAL #3.55, α=25°, n=1450r/min 1 AIR COLLECTOR AND STEEL MESH FOR INLET, 1 FLANGE FOR INLET,
3 SET
23 EXHAUST FAN 20SAM10AN003、007 L=2737m /h, H=70Pa 2 GRAVITY LOUVER FOR OUTLET

钢制轴流排风机 400V, N=0.09kW 1 台进风侧配集流器和钢丝网,1 台进风侧配法兰,出风侧配自垂百叶
STEEL
EXPLOSION-PROOF #4.0, α=25°, n=1450r/min
3 SET FLANGE FOR INLET GRAVITY LOUVER FOR OUTLET
24 AXIAL EXHAUST FAN 20SAM10AN001 L=3920m /h, H=88Pa 1
台 进风侧配法兰,出风侧配自垂百叶
钢制防爆轴流排风 400V, N=0.12kW

FRP
CORROSION-PROOF #4.5, α=25°, n=1450r/min
3 SET
25 AXIAL EXHAUST FAN 20SAM10AN004 L=5881m /h, H=113Pa 1

玻璃钢防腐轴流排 400V, N=0.25kW
风机
STEEL AXIAL #4.5, α=25°, n=1450r/min
3 SET
26 EXHAUST FAN 20SAM20AN003 L=5881m /h, H=113Pa 1

钢制轴流排风机 400V, N=0.25kW

-4-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
STEEL AXIAL #5.0, α=25°, n=1450r/min
3 SET
27 EXHAUST FAN 20SAM20AN004 L=7655m /h, H=138Pa 1

钢制轴流排风机 400V, N=0.37kW
STEEL AXIAL #5.6, α=25°, n=1450r/min
3 SET
28 EXHAUST FAN 20SAM20AN001、002 L=10379m /h, H=174Pa 2

钢制轴流排风机 400V, N=0.75kW
1×100% FLOOR
MOUNTED PACKAGED COOLING CAPACITY, QL=59.0kW
10SAM10AH406 3 SET LENGTH OF REFRIGERATING PIPE 20m,CONDENSATE PIPE 3m
29 AIR CONDITIONER L=10000m /h 2
20SAM10AH406 台 室内外机制冷剂管单程接管长度 20m,冷凝水管长度 3m
1×100% 风冷柜式 N=24.36kW, 400V/230V
空调机
1*100% FLOOR LENGTH OF REFRIGERATING PIPE 20mCONDENSATE PIPE 3m,
MOUNTED 室内外机制冷剂管单程接管长度 20m,冷凝水管长度 3m
COOLING CAPACITY, QL=59.0kW
PACKAGED AIR 3 SET THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
30 20SAM10AH405 L=10000m /h 1
CONDITIONER 台 制冷剂管道为铜管
N=24.36kW, 400V/230V
1*100% 风冷柜式 THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
空调机 冷凝水管材料为 PVC 塑料管
2*100%
EXPLOSION-PROOF
CABINET AIR GL2.0, QL=9.0kW, QR=7.5kW SET
31 20SAM10AH401、402 3 2 N=0.55kW, 400V/230V
HANDLING UNIT L=2000m /h, H=100Pa 台
2*100% 防爆立柜
式空气处理机组
2*100% CABINET
AIR
GL3.0, QL=12kW, QR=6kW SET
32 HANDLING UNIT 20SAM10AH403、404 3 2 N=0.55kW, 400V/230V
L=3000m /h, H=100Pa 台
2*100%立柜式空气
处理机组

-5-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
1*100% CABINET
AIR
GL10.0, QL=50kW SET
33 HANDLING UNIT 20SAM10AH406 3 1 N=3.0kW, 400V/230V
L=10000m /h, H=200Pa 台
1*100%立柜式空气
处理机组
2*100% CABINET
AIR
GL10.0, QL=50kW SET
34 HANDLING UNIT 20SAM20AH403、404 3 2 N=3.0kW, 400V/230V
L=10000m /h, H=200Pa 台
2*100% 立柜式空
气处理机组
2*100% CABINET
AIR
GL12.0, QL=56kW SET
35 HANDLING UNIT 20SAM20AH405、406 3 2 N=4.0kW, 400V/230V
L=12000m /h, H=200Pa 台
2*100%立柜式空气
处理机组
2*100% COMBINED
CONSTANT
TEMPERATURE 3
L=21000m /h, QL=77kW
AND HUMIDITY AIR SET N=8.0kW+20kW
36 20SAM20AH401、402 QR=20kW, △H=400Pa 2
HANDLING UNITS 台 400V/230V
Humidifying capacity 10kg/h
2*100% 组合式恒
温恒湿空气处理机

N0203 VENTILATION AND AIR CONDITIONING FOR CENTRAL CONTROL BUILDING
(5) KEPPT-RUPP-0-SDEP-SAC-DHV-0000
N0203 集控楼通风空调
SQUARE STEEL #3.15, α=25°, n=1450r/min
3 SET STEEL MESH FOR INLET,GRAVITY LOUVER AND STEEL MESH FOR OUTLET
37 AXIAL FAN J0SAC20AN001 L=1905m /h, H=55Pa 1
台 进风侧配钢丝网,出风侧配自垂百叶和钢丝网
方形钢制轴流风机 MOTOR:400V,N=0.04kW
SQUARE STEEL #3.55, α=25°, n=1450r/min
3 SET FLANGE FOR INLET,GRAVITY LOUVER AND STEEL MESH FOR OUTLET
38 AXIAL FAN J0SAC30AN002 L=2737m /h, H=70Pa 1
台 进风侧配法兰,出风侧配自垂百叶和钢丝网
方形钢制轴流风机 MOTOR:400V,N=0.09kW

-6-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
TUBULAR
3
VENTILATING FAN J0SAC10AN003 L=780m /h,H=160Pa SET CONNECTED ∅200
39 2
天花板管道式换气 J0SAC10AN002 230V,N=0.130kW 台 接管尺寸∅200

HTF-Ⅰ,#4.5,n=2900r/min
SMOKE EXHAUST FAN 3 SET FLANGE FOR AIR INLET,FLANGE FOR AIR OUTLET.
40 J0SAC30AN001 L=7981m /h,H=508Pa 1
高温消防排烟风机 台 进风侧配法兰,出风侧配法兰
MOTOR:400V,N=0.025kW
SQUARE STEEL #3.15, α=25°, n=1450r/min
J0SAC20AN003 3 SET FLANGE FOR INLET,GRAVITY LOUVER AND STEEL MESH FOR OUTLET
41 AXIAL FAN L=1905m /h, H=55Pa 2
J0SAC20AN002 台 进风侧配法兰,出风侧配自垂百叶和钢丝网
方形钢制轴流风机 MOTOR:400V,N=0.04kW
SQUARE STEEL #5, α=25°, n=1450r/min
3 SET STEEL MESH FOR INLET,GRAVITY LOUVER AND STEEL MESH FOR OUTLET
42 AXIAL FAN J0SAC10AN001 L=7655m /h, H=138Pa 1
台 进风侧配钢丝网,出风侧配自垂百叶和钢丝网
方形钢制轴流风机 MOTOR:400V,N=0.37kW
3
2*100% CABINET L=8000m /h,H=250Pa
AIR HANDLING UNIT J0SAC10AH402 QL=35.0kW SET
43 2 400/230V,N=2.2kW
2*100% 立柜式空 J0SAC10AH401 HUMIDIFYING CAPACITY: 5.0kg/h 台
气处理机组 加湿量: 5.0kg/h
2*100% COMBINED
CONSTANT 3
L=17500m /h,H=500Pa
TEMPERATURE
J0SAC40AH402 QL=75kW, QR=16kW (ELECTRIC HEATER) SET
44 AND HUMIDITY AIR 2 400/230V,N=12kW
J0SAC40AH401 HUMIDIFYING CAPACITY: 10.5kg/h 台
HANDLING UNITS
加湿量: 10.5kg/h
2*100% 组合式空
气处理机组
N0204 VENTILATION AND AIR CONDITIONING FOR FEED WATER PUMPS ROOM
(6)
N0204 给水泵房通风空调 KEPPT-RUPP-0-SDEP-SAB-DHV-0000

-7-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
FRP
CORROSION-PROOF 50SAB20AN003 AIR COLLECTOR AND STEEL MESH
AND 40SAB20AN003 #2.8, α=25°, n=1450r/min FOR INLET, GRAVITY LOUVER FOR
3 SET SMOKE ANALYSIS ROOM
45 EXPLOSION-PROOF 30SAB20AN003 L=1346m /h, H=44Pa 5 OUTLET
台 烟气在线分析柜小间
AXIAL EXHAUST FAN 20SAB20AN003 400V, N=0.12kW 进风侧配集流器和钢丝网,出风
玻璃钢防腐防爆轴 10SAB20AN003 侧配自垂百叶
流排风机
50SAB20AN002、004 AIR COLLECTOR AND STEEL MESH
BOILER ELECTRICAL EQUIPMENT ROOM
STEEL AXIAL 40SAB20AN002、004 #2.8, α=25°, n=1450r/min FOR INLET, GRAVITY LOUVER FOR
3 SET 锅炉电气设备间
46 EXHAUST FAN 30SAB20AN002、004 L=1346m /h, H=44Pa 10 OUTLET
台 WASTE HEAT BOILER ELECTRICAL
钢制轴流排风机 20SAB20AN002、004 400V, N=0.025kW 进风侧配集流器和钢丝网,出风
EQUIPMENT ROOM
10SAB20AN002、004 侧配自垂百叶
FRP 50SAB20AN001 AIR COLLECTOR AND STEEL MESH
CORROSION-PROOF 40SAB20AN001 #3.15, α=25°, n=1450r/min FOR INLET, GRAVITY LOUVER FOR SAMPLING HIGH TEMPERATURE
3 SET
47 AXIAL EXHAUST FAN 30SAB20AN001 L=1905m /h, H=55Pa 5 OUTLET COOLING RACK ROOM

玻璃钢防腐轴流排 20SAB20AN001 400V, N=0.04kW 进风侧配集流器和钢丝网,出风 取样高温冷却架间
风机 10SAB20AN001 侧配自垂百叶
50SAB10AN001~005 AIR COLLECTOR AND STEEL MESH
STEEL AXIAL 40SAB10AN001~005 #4.5, α=25°, n=1450r/min FOR INLET, GRAVITY LOUVER FOR
3 SET FEED WATER PUMPS ROOM
48 EXHAUST FAN 30SAB10AN001~005 L=5881m /h, H=113Pa 25 OUTLET
台 给水泵房
钢制轴流排风机 20SAB10AN001~005 400V, N=0.25kW 进风侧配集流器和钢丝网,出风
10SAB10AN001~005 侧配自垂百叶
2*100% CABINET 50SAB20AH401、402
BOILER ELECTRICAL EQUIPMENT ROOM
AIR 40SAB20AH401、402
GL15.0, QL=55kW SET N=5.5kW AND SMOKE ANALYSIS ROOM 用于锅炉
49 HANDLING UNIT 30SAB20AH401、402 3 10
L=15000m /h, H=250Pa 台 400V/230V 电子设备间等房间
2*100% 立 柜 式 空 20SAB20AH401、402
气处理机组 10SAB20AH401、402
N0301 AIR CONDITIONING FOR AIR COMPRESSOR BUILDING KEPPT-RUPP-0-SDEP-SAN-DHV-0000
(7)
N0301 空压机房空调

-8-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
2×50% FLOOR
MOUNTED LENGTH OF REFRIGERATING PIPE 20m、8m
COOLING CAPACITY, QL=30.0kW
PACKAGEDAIR 3 SET 室内外机制冷剂管单程接管长度:20m、8m
50 J0SAN01AH901、902 L=6500m /h 2
CONDITIONER 台 LENGTH OF CONDENSATE PIPE 3m
400V, N=10.51kW
2×50% 风冷柜式 冷凝水管长度:3m
空调机
N0302 VENTILATION FOR DIESEL GENERATOR ROOM
(8)
N0302 柴油发电机房通风 KEPPT-RUPP-0-SDEP-SAT-DHV-0100
STEEL
EXPLOSION-PROOF #2.8, α=25°, n=1450r/min
20SAT10AN002 3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
51 AXIAL FAN L=1346m /h, H=44Pa 2
10SAT10AN002 台 进风侧配集流器和钢丝网,出风侧配自垂百叶
方形钢制防爆轴流 400V, N=0.12kW
风机
STEEL
EXPLOSION-PROOF #4.0, α=25°, n=1450r/min
20SAT10AN001 3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
52 AXIAL FAN L=3920m /h, H=88Pa 2
10SAT10AN001 台 进风侧配集流器和钢丝网,出风侧配自垂百叶
方形钢制防爆轴流 400V, N=0.12kW
风机
N0401 VENTILATION AND AIR CONDITIONING FOR RAW WATER DESALINATION AND DM WATER TREATMENT PLANT
(9)
N0401 原水淡化及锅炉补给水处理间通风空调 KEPPT-RUPP-0-SDEP-SAG-DHV-0000
FRP
FLANGE FOR INLETGRAVITY
CORROSION-PROOF #3.55, α=25°, n=1450r/min
3 SET LOUVER FOR OUTLET DOSING STORAGE
53 AXIAL EXHAUST FAN J0SAG81AN005 L=2737m /h, H=70Pa 1
台 进风侧配法兰,出风侧配自垂百 药品仓库
玻璃钢防腐轴流排 400V, N=0.09kW

风机
3
CENTRIFUGAL FAN BF450-1, L=10000m /h 400V WATER TREATMENT PC
SET
54 BOX J0SAG80AN005 H=594Pa 1 DISTRIBUTION ROOM

通风机箱 400V, N=3.0kW 400V 水处理 PC 配电室
TUBULAR
3
VENTILATING FAN L=400m /h, H=160Pa SET CONNECTED ∅150
55 J0SAG80AN003、004 2
天花板管道式换气 230V, N=0.044kW 台 接管尺寸∅150

-9-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
FRP FLANGE FOR INLET, 1
CORROSION-PROOF #3.15, α=25°, n=1450r/min GRAVITYLOUVER FOR OUTLET, 1
3 SET OPERATING TESTING ROOM
56 AXIAL EXHAUST FAN J0SAG80AN007、008 L=1905m /h, H=55Pa 2 FLANGE FOR OUTLET
台 WATER ANALYSIS ROOM
玻璃钢防腐轴流排 400V, N=0.04kW 进风侧均配法兰,1 台出风侧配
风机 自垂百叶,1 台出风侧配法兰
STEEL
FLANGE FOR INLETGRAVITY
EXPLOSION-PROOF #3.15, α=25°, n=1450r/min STRATOGRAPHY GAS CYLINDER ROOM
3 SET LOUVER FOR OUTLET
57 AXIAL EXHAUST FAN J0SAG80AN006、009、010 L=1905m /h, H=55Pa 3 CHROMATOGRAPHIC ANALYSIS ROOM
台 进风侧配法兰,出风侧配自垂百
钢制防爆轴流排风 400V, N=0.12kW OIL ANALYSIS ROOM


FRP
CORROSION-PROOF FLANGE FOR INLETGRAVITY
#3.55, α=25°, n=1450r/min
EXPLOSION-PROOF 3 SET LOUVER FOR OUTLET AMMONIA DOSING ROOM
58 J0SAG81AN001 L=2737m /h, H=70Pa 1
AXIAL EXHAUST FAN 台 进风侧配法兰,出风侧配自垂百 氨加药间
400V, N=0.12kW
玻璃钢防腐防爆轴 叶
流排风机
AIR COLLECTOR AND STEEL MESH
STEEL AXIAL #4.5, α=20°, n=1450r/min FOR INLET, GRAVITY LOUVER FOR 400V WATER TREATMENT PC
3 SET
59 EXHAUST FAN J0SAG80AN001、002 L=4504m /h, H=110Pa 2 OUTLET DISTRIBUTION ROOM

钢制轴流排风机 400V, N=0.18kW 进风侧配集流器和钢丝网,出风 400V 水处理 PC 配电室
侧配自垂百叶
FRP FLANGE FOR INLET,2 FLANGEFOR
CORROSION-PROOF #5, α=20°, n=1450r/min OUTLET,1 GRAVITY LOUVER FOR
3 SET DOSING AND CLEANING ROOM
60 AXIAL EXHAUST FAN J0SAG81AN002 ~004 L=6178m /h, H=135Pa 3 OUTLET
台 加药及清洗间
玻璃钢防腐轴流排 400V, N=0.37kW 进风侧均配法兰,2 台出风侧配
风机 法兰,1 台配自垂百叶
DWT-I, #5, n=960r/min
POWER ROOF FAN 3 SET PUMP AND ROOTS BLOWER ROOM
61 J0SAG82AN001~003 L=6700m /h, H=122Pa 3
屋顶风机 台 水泵及风机间
400V, N=0.37kW
DWT-I, #8, n=960r/min
POWER ROOF FAN 3 SET WORKSHOP HALL
62 J0SAG82AN004~008 L=25000m /h, H=207Pa 5
屋顶风机 台 车间大厅
400V, N=2.2kW

-10-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
WATER ANALYSIS ROOM
CHROMATOGRAPHIC ANALYSIS ROOM
LENGTH OF REFRIGERATING PIPE
AIR-COOLED HEAT TESTER'S OFFICE
COOLING CAPACITY, QL=5.00kW 5×3m,4×9m
PUMP WALL-MOUNTED OPERATING TESTING ROOM
HEATING CAPACITY, QR=5.86kW SET 室内外机制冷剂管单程接管长
63 AIR CONDITIONER J0SAG80AH904~912 3 9 WATER TREATMENT SYSTEM CONTROL
L=750m /h 台 度:5 台 3m,4 台 9m
风冷热泵型壁挂式 ROOM
230V, N=1.77kW LENGTH OF CONDENSATE PIPE 3m
空调机 OIL ANALYSIS ROOM
冷凝水管长度:3m
BALANCE HEATING AND
CALORIMETER ROOM
CAPACITY 3 × 50% LENGTH OF
REFRIGERATING PIPE 5m、6m、
AIR-COOLED 10m
COOLING CAPACITY, QL=33.6kW
CEILING AIR 3 SET 室内外机制冷剂管单程接管长
64 J0SAG80AH901 L=6500m /h 1
CONDITIONER 台 度:5m、
400V, N=13.44kW
风冷吊顶式空调机 6m、10m LENGTH OF CONDENSATE
PIPE 3m、3m、4m
400V WATER TREATMENT PC
冷凝水管长度:3m、3m、4m
DISTRIBUTION ROOM
CAPACITY 3 × 50% LENGTH OF
400V 水处理 PC 配电室
REFRIGERATING PIPE 5m、6m、
FLOOR MOUNTED 10m
COOLING CAPACITY, QL=30.0kW
PACKAGED AIR 3 SET 室内外机制冷剂管单程接管长
65 J0SAG80AH902、903 L=5500m /h 2
CONDITIONER 台 度:5m、
400V, N=12.61kW
风冷柜式空调机 6m、10mLENGTH OF CONDENSATE
PIPE 3m、3m、4m
冷凝水管长度:3m、3m、4m
N0402 VENTILATION AND AIR CONDITIONING FOR GENERATING CHLORITE ROOM KEPPT-RUPP-0-SDEP-SAP-DHV-0000
(10)
N0402 制氯间通风空调
STEEL AXIAL #2.8,α=25°, n=1450r/min
3 SET STEEL MESH FOR INLET, GRAVITY LOUVER AND STEEL MESH FOR OUTLET
66 EXHAUST FAN J0SAP10AN002 L=1346m /h, H=44Pa 1
台 进风侧配钢丝网,出风侧配自垂百叶和钢丝网
钢制轴流排风机 400V, N=0.025kW

-11-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
STEEL AXIAL #3.55,α=25°, n=1450r/min
3 SET STEEL MESH FOR INLET, GRAVITY LOUVER AND STEEL MESH FOR OUTLET
67 EXHAUST FAN J0SAP10AN001 L=2737m /h, H=70Pa 1
台 进风侧配钢丝网,出风侧配自垂百叶和钢丝网
钢制轴流排风机 400V, N=0.09kW
LENGTH OF REFRIGERATING PIPE 5m,5m,5m,8m
2×100% 室内外机制冷剂管单程接管长度:5m、5m、5m、8m
AIR-COOLED HEAT COOLING CAPACITY, QL=7.20kW LENGTH OF CONDENSATE PIPE 5m
PUMP WALL-MOUNTED J0SAP10AH904 HEATING CAPACITY,QR=9.10kW SET 冷凝水管长度:5m
68 3 2
AIR CONDITIONER J0SAP10AH903 L=1200m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
2×100% 风冷热泵 230V, N=3.12kW 制冷剂管道材料为铜管
型壁挂式空调机 THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管
LENGTH OF REFRIGERATING PIPE 5m,5m,5m,8m
2×100% 室内外机制冷剂管单程接管长度:5m、5m、5m、8m
AIR-COOLED LENGTH OF CONDENSATE PIPE 5m
COOLING CAPACITY, QL=33.6kW
CEILING AIR J0SAP10AH902 3 SET 冷凝水管长度:5m
69 L=7000m /h 2
CONDITIONER J0SAP10AH901 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
400V, N=12.21kW
2×100% 风冷吊顶 制冷剂管道材料为铜管
式空调机 THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管
N0403 VENTILATION AND AIR CONDITIONING FOR HYDROGEN GENERATION STATION KEPPT-RUPP-0-SDEP-SAT-DHV-0000
(11)
N0403 制氢站通风空调
STEEL
EXPLOSION-PROOF #4.5, α=25°, n=1450r/min
3 SET STEEL MESH FOR INLET, GRAVITY LOUVER AND STEEL MESH FOR OUTLET
70 AXIAL EXHUAST FAN J0SAT20AN002 L=4991m /h, H=96.5Pa 1
台 进风侧配钢丝网,出风侧配自垂百叶和钢丝网
钢制防爆轴流排风 400V, N=0.25kW

STEEL
EXPLOSION-PROOF #4.5, α=25°, n=1450r/min
3 SET FLANGE FOR INLET, GRAVITY LOUVER FOR OUTLET
71 AXIAL EXHUAST FAN J0SAT20AN001 L=4991m /h, H=96.5Pa 1
台 进风侧配法兰,出风侧配自垂百叶
钢制防爆轴流排风 400V, N=0.25kW

-12-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
STEEL AXIAL #2.8, α=25°, n=1450r/min
3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
72 EXHUAST FAN J0SAT10AN001 L=1133m /h, H=35.7Pa 1
台 进风侧配集流器和钢丝网,出风侧配自垂百叶
钢制轴流排风机 400V, N=0.025kW
2×50% FLOOR LENGTH OF REFRIGERATING PIPE 5m
MOUNTED PACKAGED 室内外机制冷剂管单程接管长度:5m
AIR-COOLED AND COOLING CAPACITY, QL=13.8kW LENGTH OF CONDENSATE PIPE 3m
EXPLOSION-PROOF J0SAT20AH902 HEATING CAPACITY, QR=14.0kW SET 冷凝水管长度:3m
73 3 2
HEAT PUMP AIR J0SAT20AH901 L=2500m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
CONDITIONER 400V, N=5.23kW 制冷剂管道材料为铜管
2×50% 风冷热泵 THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
防爆柜式空调机 冷凝水管材料为 PVC 塑料管
LENGTH OF REFRIGERATING PIPE 5m
2×50% WALL
室内外机制冷剂管单程接管长度:5m
MOUNTED
COOLING CAPACITY, QL=3.50kW LENGTH OF CONDENSATE PIPE 3m
AIR-COOLED HEAT
J0SAT10AH904 HEATING CAPACITY, QR=4.40kW SET 冷凝水管长度:3m
74 PUMP AIR 3 2
J0SAT10AH903 L=650m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
CONDITIONER
230V, N=1.43kW 制冷剂管道材料为铜管
2×50%风冷热泵壁
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
挂式空调机
冷凝水管材料为 PVC 塑料管
LENGTH OF REFRIGERATING PIPE 5m
2×50% WALL
室内外机制冷剂管单程接管长度:5m
MOUNTED
COOLING CAPACITY, QL=2.6kW LENGTH OF CONDENSATE PIPE 3m
AIR-COOLED HEAT
J0SAT10AH902 HEATING CAPACITY, QR=3.0kW SET 冷凝水管长度:3m
75 PUMP AIR 3 2
J0SAT10AH901 L=500m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
CONDITIONER
230V, N=1.05kW 制冷剂管道材料为铜管
2×50% 风冷热泵
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
壁挂式空调机
冷凝水管材料为 PVC 塑料管
N0501 VENTILATION AND AIR CONDITIONING FOR INDUSTRIAL WASTEWATER TREATMENT ROOM KEPPT-RUPP-0-SDEP-SAG-DHV-0100
(12)
N0501 工业废水处理间通风空调
STEEL AXIAL #3.15, α=25°, n=1450r/min
3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
76 EXHAUST FAN J0SAG40AN001 L=1905m /h, H=55Pa 1
台 进风侧配集流器和钢丝网,出风侧配自垂百叶
钢制轴流排风机 400V, N=0.04kW

-13-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
FRP
CORROSION-PROOF #3.15, α=25°, n=1450r/min
3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
77 AXIAL EXHAUST FAN J0SAG40AN004 L=1905m /h, H=55Pa 1
台 进风侧配集流器和钢丝网,出风侧配自垂百叶
玻璃钢防腐轴流排 400V, N=0.04kW
风机
STEEL AXIAL #3.15, α=25°, n=1450r/min
3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
78 EXHAUST FAN J0SAG40AN005 L=1905m /h, H=55Pa 1
台 进风侧配集流器和钢丝网,出风侧配自垂百叶
钢制轴流排风机 400V, N=0.04kW
FRP
CORROSION-PROOF #5, α=25°, n=1450r/min
3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
79 AXIAL EXHAUST FAN J0SAG40AN002、003 L=7655m /h, H=138Pa 2
台 进风侧配集流器和钢丝网,出风侧配自垂百叶
玻璃钢防腐轴流排 400V, N=0.37kW
风机
LENGTH OF REFRIGERATING PIPE 15m
2×100% FLOOR
室内外机制冷剂管单程接管长度:15m
MOUNTED PACKAGED
COOLING CAPACITY, QL=10.6kW SET LENGTH OF CONDENSATE PIPE 4m、3m
80 AIR CONDITIONER J0SAG40AH901、902 2
230V, N=3.5kW 台 冷凝水管长度:4m、3m
2×100%风冷柜式
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
空调机
冷凝水管材料为 PVC 塑料管
N0502 VENTILATION AND AIR CONDITIONING FOR C.W. PUMP HOUSE
(13)
N0502 循环水泵房通风空调 KEPPT-RUPP-0-SDEP-SAQ-DHV-0000
#9,a=22°,n=720r/min
POWER ROOF FAN 20SAQ01AN004~006 SET
81 L=33000m³/h,H=126Pa 6
屋顶轴流排风机 10SAQ01AN004~006 台
400V,N=2.2kW
20SAQ01AN003
STEEL AXIAL #5, α=30°, n=1450r/min
20SAQ01AN002 SET FLANGE FOR INLET, GRAVITY LOUVER FOR OUTLET
82 EXHAUST FAN L=8327m³/h, H=149Pa 4
10SAQ01AN003 台 进风侧配法兰,出风侧配自垂百叶
钢制轴流排风机 400V, N=0.55kW
10SAQ01AN002
BF500-1,n=950r/min
FAN BOX 20SAQ01AN001 SET AIR INLET:800X700, AIR OUTLET:600X505.
83 L=18000m³/h, H=703Pa 2
风机箱 10SAQ01AN001 台 进风口:800X700,出风口:600X505
400V, N=7.5kW

-14-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
LENGTH OF REFRIGERATING PIPE 5m
室内外机制冷剂管单程接管长度:5m
3×50% AIR-COOLED
LENGTH OF CONDENSATE PIPE 5m
CEILING AIR 20SAQ01AH905 COOLING CAPACITY, QL=42.5kW
3 SET 冷凝水管长度:5m
84 CONDITIONER 20SAQ01AH904 L=8000m /h 3
台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
3×50%风冷吊顶式 20SAQ01AH903 400V, N=16.73kW
制冷剂管道材料为铜管
空调机
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管
LENGTH OF REFRIGERATING PIPE 5m
室内外机制冷剂管单程接管长度:5m
3×50% AIR-COOLED
LENGTH OF CONDENSATE PIPE 5m
CEILING AIR 10SAQ01AH905 COOLING CAPACITY, QL=33.6kW
3 SET 冷凝水管长度:5m
85 CONDITIONER 10SAQ01AH904 L=6500m /h 3
台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
3×50% 风冷吊顶 10SAQ01AH903 400V, N=13.44KW
制冷剂管道材料为铜管
式空调机
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管
LENGTH OF REFRIGERATING PIPE 5m
2×100% FLOOR
室内外机制冷剂管单程接管长度:5m
MOUNTED PACKAGED
20SAQ01AH902 COOLING CAPACITY, QL=13.8kW LENGTH OF CONDENSATE PIPE 5m
AIR-COOLED AND
20SAQ01AH901 HEATING CAPACITY, QR=14.0kW SET 冷凝水管长度:5m
86 HEAT PUMP AIR 3 4
10SAQ01AH902 L=2500m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
CONDITIONER
10SAQ01AH901 400V, N=5.23kW 制冷剂管道材料为铜管
2×100% 风冷热泵
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
柜式空调机
冷凝水管材料为 PVC 塑料管
N0503 VENTILATION AND AIR CONDITIONING FOR FIRE FIGHTING WATER PUMP HOUSE KEPPT-RUPP-0-SDEP-SAS-DHV-0000
(14)
N0503 消防水泵房通风空调
#5.0, α=35°, n=1450r/min
STEEL AXIAL FAN 3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
87 J0SAS10AN001~002 L=9133m /h, H=185Pa 2
方形钢制轴流风机 台 进风侧配集流器和钢丝网,出风侧配自垂百叶
400V, N=0.75kW
#3.15, α=30°, n=1450r/min
STEEL AXIAL FAN 3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
88 J0SAS10AN001 L=2072m /h, H=59Pa 1
方形钢制轴流风机 台 进风侧配集流器和钢丝网,出风侧配自垂百叶
400V, N=0.06kW

-15-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
2x100% AIR-COOLED
LENGTH OF REFRIGERATING PIPE 3m
FLOOR MOUNTED AIR COOLING CAPACITY, QL=14.10kW
3 SET 室内外机制冷剂管单程接管长度:3m
89 CONDITIONER J0SAS10AH901~902 L=2500m /h 2
台 LENGTH OF CONDENSATE PIPE 3m
2x100% 风冷柜式 400V, N=4.7kW
冷凝水管长度:3m
空调机
N0601 VENTILATION AND AIR CONDITIONING FOR ADMINISTRATION BUILDING
(15)
N0601 行政办公楼通风空调 KEPPT-RUPP-0-SDEP-SAU-DHV-0100
TUBULAR
3
VENTILATING FAN L=400m /h,H=160Pa SET CONNECTED ∅150
90 4
天花板管道式换气 230V,N=0.044kW 台 接管尺寸∅150

LENGTH OF REFRIGERATING PIPE 3m
AIR-COOLED HEAT
J0SAU02AH910~912、915、 COOLING CAPACITY, QL=3.50kW 室内外机制冷剂管单程接管长度:3m
PUMP WALL-MOUNTED
917 HEATING CAPACITY, QR=4.40kW SET LENGTH OF CONDENSATE PIPE 3m
91 AIR CONDITIONER 3 11
J0SAU02AH902、905~908 L=550m /h 台 冷凝水管长度:3m
风冷热泵型壁挂式
J0SAU01AH910 230V, N=1.43kW THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
空调机
制冷剂管道材料为铜管
J0SAU03AH911~919
J0SAU03AH901~903、 LENGTH OF REFRIGERATING PIPE 3m
AIR-COOLED HEAT
906~909 COOLING CAPACITY, QL=5.00kW 室内外机制冷剂管单程接管长度:3m
PUMP WALL-MOUNTED
J0SAU02AH913、914、916 HEATING CAPACITY, QR=5.86kW SET LENGTH OF REFRIGERATING PIPE 3m
92 AIR CONDITIONER 3 28
J0SAU02AH901、903、904、 L=750m /h 台 冷凝水管长度:3m
风冷热泵型壁挂式
909 230V, N=1.77kW THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
空调机
J0SAU01AH904、905、909、 制冷剂管道材料为铜管
911~912
AIR-COOLED HEAT
COOLING CAPACITY, QL=7.20kW
PUMP WALL-MOUNTED J0SAU03AH904~905、910
HEATING CAPACITY, QR=9.10kW SET THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
93 AIR CONDITIONER J0SAU01AH906~908 3 9
L=1200m /h 台 冷凝水管材料为 PVC 塑料管
风冷热泵型壁挂式 J0SAU01AH901~903
230V, N=3.12kW
空调机
N0602 VENTILATION AND AIR CONDITIONING FOR DORMITORY BUILDING KEPPT-RUPP-0-SDEP-SAU-DHV-0000
(16)
N0602 宿舍楼通风空调

-16-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
TUBULAR
3
VENTILATING FAN L=400m /h,H=160Pa SET CONNECTED ∅150, WITH NON-RETURN DAMPER
94 69
天花板管道式换气 230V,N=0.044kW 台 接管尺寸∅150,配止回阀

LENGTH OF REFRIGERATING PIPE 5m
室内外机制冷剂管单程接管长度:5m
AIR-COOLED HEAT
J0SAU41AH914~924 COOLING CAPACITY, QL=3.50kW LENGTH OF CONDENSATE PIPE 5m
PUMP WALL-MOUNTED
J0SAU41AH901~911 HEATING CAPACITY, QR=4.40kW SET 冷凝水管长度:5m
95 AIR CONDITIONER 3 44
J0SAU40AH913~923 L=650m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
风冷热泵型壁挂式
J0SAU40AH901~911 230V, N=1.43kW 制冷剂管道材料为铜管
空调机
THE MATERIALS OF CONDENSATE PIPING IS PVC PIPE
冷凝水管材料为塑料管
LENGTH OF REFRIGERATING PIPE 5m
室内外机制冷剂管单程接管长度:5m
AIR-COOLED HEAT J0SAU42AH914~926
COOLING CAPACITY, QL=5.00kW LENGTH OF CONDENSATE PIPE 5m
PUMP WALL-MOUNTED J0SAU42AH901~912
HEATING CAPACITY, QR=5.86kW SET 冷凝水管长度:5m
96 AIR CONDITIONER J0SAU41AH925、926 3 29
L=750m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
风冷热泵型壁挂式 J0SAU41AH911
230V, N=1.77kW 制冷剂管道材料为铜管
空调机 J0SAU40AH912
THE MATERIALS OF CONDENSATE PIPING IS PVC PIPE
冷凝水管材料为塑料管
LENGTH OF REFRIGERATING PIPE 5m
室内外机制冷剂管单程接管长度:5m
AIR-COOLED HEAT
COOLING CAPACITY, QL=7.20kW LENGTH OF CONDENSATE PIPE 5m
PUMP WALL-MOUNTED
J0SAU42AH913 HEATING CAPACITY, QR=9.10kW SET 冷凝水管长度:5m
97 AIR CONDITIONER 3 2
J0SAU41AH913 L=1200m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
风冷热泵型壁挂式
230V, N=3.12kW 制冷剂管道材料为铜管
空调机
THE MATERIALS OF CONDENSATE PIPING IS PVC PIPE
冷凝水管材料为塑料管
N0603 VENTILATION AND AIR CONDITIONING FOR WORKSHOP AND STORE BUILDING KEPPT-RUPP-0-SDEP-SAU-DHV-0200
(17)
N0603 检修间和材料库通风空调

-17-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
TUBULAR
3
VENTILATING FAN L=780m /h,H=160Pa SET
98 3
天花板管道式换气 230V,N=0.130kW 台

#6.3, α=35°, n=1450r/min
STEEL AXIAL FAN 3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
99 J0SAU61AN002~004 L=17426m /h, H=260.7Pa 3
方形钢制轴流风机 台 进风侧配集流器和钢丝网,出风侧配自垂百叶
400V, N=2.2kW
#2.8, α=25°, n=1450r/min
STEEL AXIAL FAN 3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
100 J0SAU61AN001 L=1133m /h, H=35.7Pa 1
方形钢制轴流风机 台 进风侧配集流器和钢丝网,出风侧配自垂百叶
400V, N=0.025kW
LENGTH OF REFRIGERATING PIPE 3m
室内外机制冷剂管单程接管长度:3m
AIR-COOLED HEAT
COOLING CAPACITY, QL=3.50kW LENGTH OF CONDENSATE PIPE 3m
PUMP WALL-MOUNTED J0SAU62AH904
HEATING CAPACITY, QR=4.40kW SET 冷凝水管长度:3m
101 AIR CONDITIONER J0SAU62AH903 3 3
L=550m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
风冷热泵型壁挂式 J0SAU61AH907
230V, N=1.25kW 制冷剂管道材料为铜管
空调机
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管
LENGTH OF REFRIGERATING PIPE 3m
室内外机制冷剂管单程接管长度:3m
AIR-COOLED HEAT
J0SAU62AH905~906 COOLING CAPACITY, QL=5.00kW LENGTH OF CONDENSATE PIPE 3m
PUMP WALL-MOUNTED
J0SAU62AH901~902 HEATING CAPACITY, QR=5.86kW SET 冷凝水管长度:3m
102 AIR CONDITIONER 3 7
J0SAU61AH905~906 L=750m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
风冷热泵型壁挂式
J0SAU61AH908 230V, N=1.77kW 制冷剂管道材料为铜管
空调机
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管

-18-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
LENGTH OF REFRIGERATING PIPE 3m
室内外机制冷剂管单程接管长度:3m
2x100% AIR-COOLED
LENGTH OF CONDENSATE PIPE 3m
WALL-MOUNTED AIR COOLING CAPACITY, QL=7.20kW
3 SET 冷凝水管长度:3m
103 CONDITIONER J0SAU61AH903、904 L=1200m /h 2
台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
2x100% 风冷壁挂 230V, N=3.12kW
制冷剂管道材料为铜管
式空调机
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管
LENGTH OF REFRIGERATING PIPE 3m
室内外机制冷剂管单程接管长度:3m
AIR-COOLED HEAT
COOLING CAPACITY, QL=7.20kW LENGTH OF CONDENSATE PIPE 3m
PUMP WALL-MOUNTED
HEATING CAPACITY, QR=9.10kW SET 冷凝水管长度:3m
104 AIR CONDITIONER J0SAU61AH901、902 3 2
L=1200m /h 台 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
风冷热泵型壁挂式
230V, N=3.12kW 制冷剂管道材料为铜管
空调机
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管
N0604 VENTILATION AND AIR CONDITIONING FOR ADMINISTRATIVE ZONE SWITCHGEAR ROOM
(18)
N0604 厂前区配电室通风空调 KEPPT-RUPP-0-SDEP-SAU-DHV-0300
#3.15, α=25°, n=1450r/min
STEEL AXIAL FAN 3 SET AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
105 J0SAU70AN001 L=1905m /h, H=55Pa 1
方形钢制轴流风机 台 进风侧配集流器和钢丝网,出风侧配自垂百叶
400V, N=0.04kW
2x100% AIR-COOLED
LENGTH OF REFRIGERATING PIPE 3m
FLOOR MOUNTED AIR COOLING CAPACITY, QL=14.10kW
3 SET 室内外机制冷剂管单程接管长度:3m
106 CONDITIONER J0SAU70AH901~902 L=2500m /h 2
台 LENGTH OF CONDENSATE PIPE 3m
2x100% 风冷柜式 400V, N=4.7kW
冷凝水管长度:3m
空调机

HVAC EQUIPMENT FOR RIVER WATER INTAKE AREA 厂外取水部分暖通设备

N0504 VENTILATION FOR RIVER WATER INTAKE PUMP HOUSE


(19)
N0504 取水泵房通风 KEPPT-RUPP-0-SDEP-SAP-DHV-0100

-19-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
#6.3, α=25°, n=1450r/min AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
STEEL AXIAL FAN J0SAP20AN005~008 3 SET
1 L=15297m /h, H=220Pa 4 进风侧配集流器和钢丝网,出风侧配自垂百叶
钢制轴流进风机 台
400V, N=1.5kW PRUCHASED BY KEPPT
#6.3, α=25°, n=1450r/min STEEL MESH FOR INLET AND OUTLET
STEEL AXIAL FAN J0SAP20AN001~004 3 SET
2 L=15297m /h, H=220Pa 4 进风侧及出风侧配钢丝网
钢制轴流进风机 台
400V, N=1.5kW PRUCHASED BY KEPPT
N0505 VENTILATION AND AIR CONDITIONING FOR ELECTRIC ROOM AT RIVER WATER INTAKE PUMP STATION KEPPT-RUPP-0-SDEP-SAP-DHV-0200
(20)
N0505 取水泵房配电室通风空调
AIR COLLECTOR AND STEEL
STEEL AXIAL MESH FOR INLET, GRAVITY LOUVER
#2.8, α=25°, n=1450r/min SET
3 EXHAUST FAN J0SAP30AN003 3 1 FOR OUTLET INTEGRATED WITH FAN
L=1346 m /h, H=44Pa400V, N=0.025kW 台
钢制轴流排风机 进风侧配集流器和钢丝网,出风侧配自垂百叶
PRUCHASED BY KEPPT
STEEL FLANGE FOR INLET
EXPLOSION-PROOF #2.8, α=25°, n=1450r/min GRAVITY LOUVER FOR
3 SET
4 AXIAL EXHAUST FAN J0SAP30AN004 L=1346 m /h, H=44Pa 1 OUTLET INTEGRATED WITH FAN

钢制防爆轴流排风 400V, N=0.12kW 进风侧配法兰,出风侧配自垂百叶
机 PRUCHASED BY KEPPT
AIR COLLECTOR AND STEEL
STEEL AXIAL #4.5, α=20°, n=1450r/min MESH FOR INLET, GRAVITY LOUVER
3 SET
5 EXHAUST FAN J0SAP30AN006、007 L=4504 m /h, H=110Pa 2 FOR OUTLET INTEGRATED WITH FAN

钢制轴流排风机 400V, N=0.18kW 进风侧配集流器和钢丝网,出风侧配自垂百叶
PRUCHASED BY KEPPT
3
CENTRIFUGAL FAN DBF100, L=10000 m /h
SET
6 BOX J0SAP30AN005 H=594Pa 1 PRUCHASED BY KEPPT

通风机箱 400V, N=3.0kW
AIR-COOLED HEAT LENGTH OF REFRIGERATING
PUMP COOLING CAPACITY, Q L=5.0kW PIPE: 6*3m
WALL-MOUNTED AIR HEATING CAPACITY, Q R=5.86kW SET 室内外机制冷剂管单程接管长度:6*3m
7 J0SAP30AH901、902 3 2
CONDITIONER L=750 m /h 台 LENGTH OF CONDENSATE
风冷热泵型壁挂式 230V, N=1.77kW PIPE: 6*3m
空调机 冷凝水管长度:6*3m

-20-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
2*100% THE MATERIALS OF REFRIGERATING
EXPLOSION-PROOF PIPING IS COPPER PIPE
AIR-COOLED HEAT COOLING CAPACITY, Q L =5.0kW 制冷剂管道材料为铜管
PUMP HEATING CAPACITY, Q R =5.86kW SET THE MATERIALS OF CONDENSATE
8 J0SAP30AH905、906 3 2
WALL-MOUNTED AIR L=750 m /h 台 PIPING IS PVC PLASTIC PIPE
CONDITIONER 230V, N=1.77kW 冷凝水管材料为 PVC 塑料管
2*100%防爆风冷热 PRUCHASED BY KEPPT
泵型壁挂式空调机
2*100% AIR-COOLED
HEAT PUMP COOLING CAPACITY, Q L =7.2kW
WALL-MOUNTED AIR HEATING CAPACITY, Q R =9.1kW SET
9 J0SAP30AH903、904 3 2
CONDITIONER L=1200 m /h 台
2*100%风冷热泵型 230V, N=3.12kW
壁挂式空调机
LENGTH OF REFRIGERATING
PIPE 4*3m. LENGTH OF
CONDENSATE PIPE 4*3m.
4*33% FLOOR
室内外机制冷剂管单程接管长度:4*3m
MOUNTED
COOLING CAPACITY, Q L =21.7kW 冷凝水管长度:4*3m
PACKAGED AIR J0SAP30AH907~910 3 SET
10 L=4000 m /h 4 THE MATERIALS OF REFRIGERATING
CONDITIONER 台
400V, N=7.98kW PIPING IS COPPER PIPE 制冷剂管道为铜管
4*33%风冷柜式空
THE MATERIALS OF CONDENSATE
调机
PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管
PRUCHASED BY KEPPT
N0506 VENTILATION AND AIR CONDITIONING FOR DOSING DEVICE ROOM AND ELECTRIC ROOM KEPPT-RUPP-0-SDEP-SAP-DHV-0300
(21)
N0506 加药间及配电室通风空调

-21-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
LENGTH OF REFRIGERATING PIPE 1 × 11m,1 × 7m,2 × 3m. LENGTH OF
CONDENSATE PIPE 1×10m,1×6m,2×3m.
4×33% FLOOR 室内外机制冷剂管单程接管长度 1 台 11m,1 台 7m,2 台 3m,冷凝水管长
MOUNTED PACKAGED COOLING CAPACITY, QL=13.6kW 度 1 台 10m,1 台 6m,2 台 3m
3 SET
11 AIR CONDITIONER J0SAP40AH907~910 L=2500m /h 4 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE

4×33% 风冷柜式 400V, N=5.5kW 制冷剂管道为铜管
空调机 THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
冷凝水管材料为 PVC 塑料管
PRUCHASED BY KEPPT
LENGTH OF REFRIGERATING PIPE 3×6m
室内外机制冷剂管单程接管长度:3×6m
2×100%
LENGTH OF CONDENSATE PIPE 3×6m
AIR-COOLED HEAT COOLING CAPACITY, QL=7.2kW
冷凝水管长度:3×6m
PUMP WALL-MOUNTED HEATING CAPACITY, QR=9.1kW SET
12 J0SAP40AH901、902 3 2 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
AIR CONDITIONER L=1200m /h 台
制冷剂管道材料为铜管
2×100% 风冷热泵 230V, N=3.12kW
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
型壁挂式空调机
冷凝水管材料为 PVC 塑料管
PRUCHASED BY KEPPT
LENGTH OF REFRIGERATING PIPE 3×6m
2×100%
室内外机制冷剂管单程接管长度:3×6m
EXPLOSION-PROOF
LENGTH OF CONDENSATE PIPE 3×6m
AIR-COOLED HEAT COOLING CAPACITY, QL=5.0kW
冷凝水管长度:3×6m
PUMP WALL-MOUNTED HEATING CAPACITY, QR=5.86kW SET
13 J0SAP40AH903、904 3 2 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
AIR CONDITIONER L=750m /h 台
制冷剂管道材料为铜管
2×100%防爆风冷 230V, N=1.77kW
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
热泵型壁挂式空调
冷凝水管材料为 PVC 塑料管

PRUCHASED BY KEPPT

-22-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
LENGTH OF REFRIGERATING PIPE 3×6m
室内外机制冷剂管单程接管长度:3×6m
2×50% AIR-COOLED
LENGTH OF CONDENSATE PIPE 3×6m
HEAT PUMP COOLING CAPACITY, QL=5.0kW
冷凝水管长度:3×6m
WALL-MOUNTED AIR HEATING CAPACITY, QR=5.86kW SET
14 J0SAP40AH905、906 3 2 THE MATERIALS OF REFRIGERATING PIPING IS COPPER PIPE
CONDITIONER L=750m /h 台
制冷剂管道材料为铜管
2×50% 风冷热泵 230V, N=1.77kW
THE MATERIALS OF CONDENSATE PIPING IS PVC PLASTIC PIPE
型壁挂式空调机
冷凝水管材料为 PVC 塑料管
PRUCHASED BY KEPPT
3
CENTRIFUGAL FAN DBF140, L=14000m /h
SET
15 BOX J0SAP40AN007 H=579Pa 1 PRUCHASED BY KEPPT

通风机箱 400V, N=3.6kW
FRP
CORROSION-PROOF #5.6, α=25°, n=1450r/min AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
3 SET
16 AXIAL EXHAUST FAN J0SAP40AN001、002 L=10379m /h, H=174Pa 2 进风侧配集流器和钢丝网,出风侧配自垂百叶

玻璃钢防腐轴流排 400V, N=0.75kW PRUCHASED BY SINOHYDRO
风机
STEEL AXIAL #4.5, α=35°, n=1450r/min AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
3 SET
17 EXHAUST FAN J0SAP40AN005、006 L=6658m /h, H=150Pa 2 进风侧配集流器和钢丝网,出风侧配自垂百叶

钢制轴流排风机 400V, N=0.37kW PRUCHASED BY KEPPT
STEEL
EXPLOSION-PROOF #2.8, α=25°, n=1450r/min FLANGE FOR INLETGRAVITY LOUVER FOR OUTLET
3 SET
18 AXIAL EXHAUST FAN J0SAP40AN004 L=1346m /h, H=44Pa 1 进风侧配法兰,出风侧配自垂百叶

钢制防爆轴流排风 400V, N=0.12kW PRUCHASED BY KEPPT

STEEL AXIAL #2.8, α=25°, n=1450r/min AIR COLLECTOR AND STEEL MESH FOR INLET, GRAVITY LOUVER FOR OUTLET
3 SET
19 EXHAUST FAN J0SAP40AN003 L=1346m /h, H=44Pa 1 进风侧配集流器和钢丝网,出风侧配自垂百叶

钢制轴流排风机 400V, N=0.025kW PRUCHASED BY KEPPT
N0507 AIR CONDITIONING FOR WATER INTAKE GUARD ROOM KEPPT-RUPP-0-SDEP-SAT-DHV-0400
(22)
N0507 取水警卫室空调

-23-
LIST OF HVAC EQUIPMENT IN THE PLANT
暖通设备清册
ITEM KKS CODE EQUIPMENT TYPE AND SPECIFICATION UNIT QTY. REMARK
序号 KKS 编码 名 称 型 号 规 格 单位 数量 备 注
AIR-COOLED HEAT LENGTH OF REFRIGERATING PIPE 3m
COOLING CAPACITY, QL=5.00kW
PUMP WALL-MOUNTED 室内外机制冷剂管单程接管长度:3m
J0SAP50AH902 HEATING CAPACITY, QR=5.86kW SET
20 AIR CONDITIONER 3 2 LENGTH OF CONDENSATE PIPE 3m
J0SAP50AH901 L=750m /h 台
风冷热泵型壁挂式 冷凝水管长度:3m
230V, N=1.77kW
空调机 PRUCHASED BY KEPPT