Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

RM-40 Service Manual

z 11. Scanner initialization


11.1. Enable scan function

When starting using the scanner, customer should change some SPEC of the

scale referring to the CUSTOMER SPECIFICATION LIST.

CUSTOMER SPECIFICATION [REZERO] + [1][4][1]


Spec No BIT 3 BIT 2 BIT 1 BIT 0
RTS/CTS Baud rate of RS-232C
handshaking of
001 RS-232C 000 - 1200 bps 011 - 9600 bps
0 - On 001 - 2400 bps 100 - 19200 bps
1 - OFF 010 - 4800 bps 101 ~ 111 - Not used

Stop bit of RS-232C Data length of Parity of RS-232C


RS-232C
002
0 - 1 bit 0 - 7 bit 00 - None 10 - Even
1 - 2 bit 1 - 8 bit 01 - Odd 11 - Not used
Centering of shop name Center of commodity Barcode scanner Non-PLU item enter
by barcode scanner
on label name on label
023
0 - Allow 0 - Allow 0 - Allow 0 - Allow
1 - Inhibit 1 - Inhibit 1 - Inhibit 1 - Inhibit
SPEC001=”1011” SPEC002=”0100” SPEC023=”**0*”

11.2. Scanner initialization

The CCD barcode scanner is STE factory optional parts. Normally, the

initialization had been finished when left factory so the customers can use the

scanner directly without setting it again. In some cases, when you find it not

working please initial the scanner according the following steps. (Connect the

scanner to the scale RS232 port first, plug in the DC power supplier for the

scanner, and then scan the following barcode one by one)

Page No. 71
RM-40 Service Manual

1、Enter Setup

2、Restore Default Settings

3、Update

4、Enter Setup

5、Postfix Code

6、Hexadecimal Digits=0

7、Hexadecimal Digits=D

8、Hexadecimal Digits=0

9、Hexadecimal Digits=A

10、Validate

11、Update

Page No. 72