1.

GROUND RELAY
Check GROUND RELAY tripped in DB OR POWER
a) Dynamic brake
Avoid dynamic brake and work further. Switch OFF blended brake cut out
switch. Check any foreign body struck up with the Grid.

b) POWER
Check GR operates in standstill or loco moving.
Check GR tripping frequently or occasionally.
Stop loco and disable truck 1 and work further. If GR trip again enable truck 1
and disable truck 2. Inform PRC/Shed as loco can work around 3 hours with
single truck.

Check any cable rubbing in TA room, behind ECC1, water in ECC2, water
falling to IPR resistance in TA room, water entry to ECC1.

If GR trip in both truck stop loco and conduct excitation test from self test
menu.
If GR trip in excitation test, problem may be in TA circuit. Conduct self load
test and GR trip is noticed arrange for relief loco.