Download as pdf or txt
Download as pdf or txt
You are on page 1of 75

vFactory test run manual

For Ver3.40.0X

Modify History

Author
Rev. Date Content
Company Name
1 2010/11/10 AMADA K.Shinoda For Ver3.40.0X
2 2011/05/18 AMADA K.Shinoda For Windows server 2008R2
vFactory test run manual For Ver3.40.0X

Table of Contents
Introduction .......................................................................................... 3
1. Check MauiFactory ......................................................................... 4
2. How to connect to AMNC-F ............................................................ 5
3. UNIT-8 Setting ................................................................................ 8
4. How to Connect to AMNC Bender Ver4........................................ 15
5. How to Connect to AMNC Bender Ver5........................................ 20
6. Make and install a factory layout................................................... 34
7. Setup vFactory .............................................................................. 35
8. Setup Notification .......................................................................... 47
9. Setup camera ................................................................................ 53
10. Setup vFactory Client ................................................................. 57
11. IE8 settings ................................................................................. 59
12. IE9 settings (Optional) ................................................................ 62
13. Backup vFactory environment .................................................... 64
14. Restore vFactory environment ................................................... 69

2
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Introduction
This manual is described of the work sequence at the time of supplying and making a test run
of vFactory.

vFactory test run work sequence

Start

Installation of the vFactory server


1. Check MauiFactory

Set up for connecting with vFactory by each machine.


2. How to connect to AMNC-F
3. UNIT-8 Setting
4. How to Connect to AMNC Bender Ver4.
5. How to Connect to AMNC Bender Ver5.

Setup on vFactory computer


6. Make and install a factory layout
7. Setup vFactory
8. Setup Notification
9. Setup camera

Internet explorer setting.


10. Setup vFactory Client
11. Ie8 settings
12. Ie9 settings

Backup customer environment


13. Backup environment

3
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

1. Check MauiFactory
Log on to MauiFactory and check whether MauiFactory is working correctly.

Log on to MauiFactory from Internet Explorer.


Start Internet Explorer in vFactory computer. Select MauiFactory from Favorites menu.
After you open the web page, the following interface will display.
Input Admin as the Username, Maui as the Password and log on.

Please check whether the screen of MauiFactory is displayed.

4
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

2. How to connect to AMNC-F


In this chapter, we will explain the connection method of AMNC-F to vFactory.
The connection with AMNC-F is set up by AMNC Daemon of a task tray.

Notice
The IP address of vFactory is inputted during installation. First, please examine the IP
address of vFactory.

After opening the interface of AMNC-F, press Ctrl and Esc at the same time to display start
menu. Press Ctrl, then click the icon of AMNC Daemon.

5
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Click the Virtual Factory Viewer tab.

Enable : If you want to connect to vFactory, turn on the check mark in the checkbox.
IP Address : Input the IP address of vFactory computer.
Machine Name : Input the machine name which you want to register to vFactory.
FMS : When the FMS controller is connected, turn on the check mark in the
checkbox.
IP Address : Input the IP address of FMS controller.

After that, click Apply and OK to reflect the modified content.

All the steps for connecting with vFactory are completed.


Please restart the AMNC-F.

6
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Log on to MauiFactory after the AMNC-F starts. Check the machine object which you set up
exists in MauiFactory or not.

Refer to 1. Check MauiFactory for the method of logon to MauiFactory.

Check whether a status changes according


to the status of a processing machine.

7
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

3. UNIT-8 Setting
In this chapter, we will talk about how to use UNIT-8, that is, the method of connecting ordinary
machine to vFactory.
Example: The old NCT (COMA, PEGA, VIPROS) and L/UL Device.

We can set up Unit-8 with the PC connected by LAN. UNIT8 has the server function of WWW,
and we can set the parameter by Internet Explorer.

Notice
Recommend to use the later version of Ver5.5SP1 of Internet Explorer.

3.1. Registration to Trusted sites


If OS of your PC is Windows2003 server or Windows2008 server, register the IP address of
AMC-UNIT8 into a trusted site. This work is unnecessary when the OS is WindowsXP.

(1) Start Internet Explorer and select the Internet options of Tools menu.
(2) Select the Security tab.
(3) Select the Trusted sites.
(4) Click the Sites button.
(2) Select the Security (3) Select the Trusted
tab. sites.

(4) Click the Sites


button.

8
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(5) Input the IP address of UNIT8 in Add this site to the zone:.
(6) Click the Add button.
(7) Turn off the check box of Require server verification (https:) for all sites in this zone.
(8) Click the Close button.

(5) Input the UNIT-8 IP (6) Click the Add button.


address.

(7) Put off the check box

(8) Click the Close button.

3.2. How to access AMC-UNIT8


Start Internet Explorer on your PC. Input http://192.9.200.155 in URL.
* Set the default IP address of AMC-UNIT8 as 192.9.200.155.

The screen which enters a user name and a password will appear. Input admin in Account
and password in Password, then logon.

9
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

3.3. Change IP Address of UNIT-8


When connecting two or more UNIT-8, or customer network environment differs from the IP
address class of an ASIS network, please change the IP address of UNIT-8.

Select the NETWORK page. Please modify the web item according to the customer
environment. After the modification, click the Apply button.

3.4. Set up vFactory IP Address


Please change when the IP address of vFactory is different from the standard address.
(192.9.200.150)

Select the SOAP page. Input vFactory IP address in Server URL.


Default address is http://192.9.200.150:8989
When you want to change IP address, modify part of the IP address. It does not change after
":". For example, “10.11.12.13” -> http://10.11.12.13:8989.
After the modification, click the Apply button.

10
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

3.5. Time Server Setting


Set up synchronize the time of vFactory, and the time of UNIT-8, so that the time stamp of
machine working information to become the same.
Please set when the IP address of vFactory is not the standard one. (192.9.200.150)

Select the SYSTEM panel. Then click the Setup button on Time Setup.

Please input vFactory IP address in the Time Server area.


After the modification, click the Change button.

11
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

3.6. Channel Setting


Input a name to signal of the Channel, which connects to UNIT-8.

Select the CHANNEL page, and input the information.


When UNIT-8 connects to ASR48M, the following table displays three working statuses: Ch1 is
power ON, Ch2 is working and Ch3 is alarm active.

Channel Parent Unit Reverse On-Delay OFF-Delay


Name Name Name
Ch1 POW f01 ASR48M 0 0
Ch2 RUN f01 ASR48M 0 0
Ch3 ALM f01 ASR48M 0 0

[Explanation]

Channel Name
Input Channel’s name. vFactory regards the following five words as key words.
POW : Power ON
RUN : Working
SET : Setting
ALM : Alarm active
CNT : Count. Calculate the shot quantity of the bender.

* The signal name of each machine is described on the drawing of each connection kit.

Parent Name
Input the name of Parent object. The default name is f01.

Unit Name
Input the connected machine name.

12
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Reverse
If you want to reverse and output the inputted signal logic, turn on a check mark in the
checkbox.

On-Delay, OFF-Delay
Input when we need ON-Delay and Off-Delay. Signal’s ON and OFF will delay according to the
inputting second.

3.7. VIDEO Parameter Setting


When using the monitoring camera, it need adjust the video parameter.

Select the VIDEO panel.


Input the machine name in Parent area. (Machine name is the name registered into
MafuiFactory.)
Input the camera name in Name area.
Confirm whether Video Pattern is Streaming.
After the modification, click the Apply button.

13
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

3.8. Restart the UNIT-8


Restart the UNIT-8 in order to enable change of a setup.

Select the MAINTAIN panel, then click the Shutdown button.

Log on to MauiFactory after the Unit-8 starts. Check the machine object which you set up
exists in MauiFactory or not.

Refer to 1. Check MauiFactory for the method of logon to MauiFactory.

Check whether a status changes according


to the status of a machine.

14
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

4. How to Connect to AMNC Bender Ver4.


In this chapter, we will explain the connection method of AMNC bender ver4 to vFactory.

Notice
* It needs a keyboard for installation. Please start the AMNC bender after connecting a
keyboard.
* If EWF machine, please install after cancel protection.
* Installation should use the installer corresponding to the version of AMNC.

Installer exists in CD according to a version as below:


¥STD_PUBLIC¥PUBLIC¥VF-AMNCB_MON¥Ver4.06.02 – Ver4.07.07
¥STD_PUBLIC¥PUBLIC¥VF-AMNCB_MON¥Ver4.07.08
¥STD_PUBLIC¥PUBLIC¥VF-AMNCB_MON¥Ver4.08.03 -

Start the installer.

Click the Next button.

15
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Click the Next button. Please do not change a destination folder.

Input the IP address of the vFactory computer, then click the NEXT button.

16
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Input the machine name to register to vFactory. Then click the NEXT button.

Click the NEXT button.

17
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Click the NEXT button.

Click the Finish button.

18
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Notice
It is necessary to change a parameter or later the AMNC bender Ver4.08.03.

Please change parameter No.92 into 1.


In the case of the EWF machine, please change into write-protected mode.

All the steps for connecting with vFactory are completed.


Please restart the AMNC bender.

Log on to MauiFactory after the AMNC bender starts. Check the machine object which you set
up exists in MauiFactory or not.

Refer to 1. Check MauiFactory for the method of logon to MauiFactory.

Check whether a status changes


according to the status of a machine.

19
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

5. How to Connect to AMNC Bender Ver5.


5.1. Preparation
It needs a keyboard for installation. Please start the AMNC bender after connecting a
keyboard.

5.2. Change System adjustment


(1) Push the MAINT button.

20
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(2) Push the PARAM button.

(3) The screen of a password will appear. Input “14789632”, then push the enter button.

21
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(4) Change the parameter No.32 into 1 from 0. Then push the EXIT button.

Change into 1 from 0

5.3. Disable EWF function


(1) Push the UTILITY button.

22
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(2) Push the EwfMgr operate button.

When push the EwfMgr operate button, the next screen will appear.

(b)

(c)
(a)

(a) Push the EwfDisable button.


(b) Please check that COMMAND text area is yellow.
(c) Push the OK button.

23
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(4) Push the SHIUTDOWN button.

Notice
When you turn off the power, please be sure to make oil pressure into "OFF."

(5) If the AMNC bender is started again, the following dialog message will appear.
Push the No button will start AmncV5.

24
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(6) After the AmncV5 starts, please check whether the mark of the key in the screen upper
right is blinking.
When the mark of a key is not blinking, please redo the work of 5.3 Disable EWF function.

25
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

5.4. Change ProcessAdmin.ini file.


(1) Push the MAINT button.
(2) Push the UTILITY button.
(3) Pus the iniFile Editor button.

Open “C:¥Program Files¥Amada¥Amnc¥VirtualFactory¥ProcessAdmin.ini” file.

Input the IP address of vFactory computer into Server of an Env section.


Input the machine name that you want to register to vFactory into Name of an Object section.

After the modification, push the save button to save ini file.

26
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

5.5. Enable vFactory communication function


(1) Push the MAINT button.

(2) Push the PARAM button.

27
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(3) Change the system parameter No74 into 1. Then push the EXIT button.

Change into 1 from 0

5.6. Enable EWF function


(1) Push the UTILITY button of a MAINT screen.

28
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(2) Push the EwfMgr operate button.

Following screen will appear.

(b)

(c)
(a)

(a) Push the EwfEnable button.


(b) Please check that STATE and COMMAND are yellow.
(c) Please push the OK button after checking that it is yellow.

29
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(3) Push the SHIUTDOWN button.

Notice
When you turn off the power, please be sure to make oil pressure into "OFF."

30
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

5.7. Change System adjustment


(1) After the AmncV5 starts, please check whether the mark of the key in the screen upper
right is on. When the mark of a key is not on, please redo the work of 5.6 Enable EWF
function. When the key mark is on, push the MAINT button.

(2) Push the PARM button.

31
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(3) Change the parameter No.32 into 0 from 1. Then push the EXIT button.

Change into 0 from 1

(4) Push the PARAM button.

32
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(5) Check whether a password input screen appears.

All the steps for connecting with vFactory are completed.


Please restart the AMNC bender.

5.8. Check machine object


Log on to MauiFactory after the AMNC bender starts. Check the machine object which you set
up exists in MauiFactory or not.

Refer to 1. Check MauiFactory for the method of logon to MauiFactory.

Check whether a status changes


according to the status of a machine.

33
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

6. Make and install a factory layout


You can make the layout of a customer factory with layout tool software.

Please save the layout which you created by the name f01.ovf at the following folder.

Windows Server 2008R2


C:¥Program Files (x86)¥Amada¥VPSS¥vFactory¥web¥vfsj¥layout¥f01¥OrViewer

Other OS
C:¥Program Files¥Amada¥VPSS¥vFactory¥web¥vfsj¥layout¥f01¥OrViewer

Notice!
* Please be sure to save in a lower case character.
* Please refer to another document for operation of LayoutTool software.

34
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

7. Setup vFactory
7.1. Start vFactory Setup program
Click [Start] -> [All programs] -> [vFactory] -> [vFactorySetup].
Please input Maui into the column of a password. vFactorySetup program will appear.

35
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

7.2. Edit the customer company name


Click "Virtual" on the left-hand side of a screen, setting screen will appear on right-hand side.

Please input a customer's company name into the column of Server Name.
Other columns are the items set up when using the notification function of E-mail.

Please click the Register button after edit. Click the Yes button.

36
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Explanation
Server Name Input the customer company name.
Email SMTP Server Input the customer’s SMTP server name.
Port No. If the provider is doing Outbound Port 25 Blocking control,
please input the port number.
Email SMTP Account Name Input the customer’s SMTP account name.
Email SMTP Account Password Input the customer’s SMTP password.
Email Return Address Input the customer’s mail address.
Email Charset Please select what is suitable.
Email Interface Enable Do not edit.
Email POP Server Do not edit.
Email Account Name Do not edit.
Email Account Password Do not edit.
POP before SMTP Do not edit.
POP before SMTP TimeOut Do not edit.

37
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

7.3. Edit the customer factory name


(1) Click f01.
(2) Edit Description. Please input the customer’s factory name.
(3) Please confirm Process Sequence.
(4) Click the Register button.

(1) (2)

(3)

(4)

38
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

7.4. Setup blanking machine


(1) Click the machine which you want to setup.
(2) Edit parameter.
(3) Click the Register button.

(2)

(1)

(3)

Explanation
Notify Process Please check in the case of the AMNC machine.
Object name Cannot edit.
Process Types Please select Cutting.
Workcenter Please select CuttingWorkCenter.
Machine Name Input the machine name. It is the machine name displayed on
vFactory.
PCLID Input the machine name. It is the name of the machine management
of SDD.
If customer is sharing the processing program with other processing
machines, please input the other machine name after a semicolon.
Ex) EM3510NT;EML3510NT
3D Model ID Please input the identification name (model ID) of the machine of a
factory layout file.
Amada Type Please select what is suitable.
NCT : NCT, Hybrid : Combi machine. ex) EML. Laser: Laser
Image Please select what is suitable.

39
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

7.5. Setup bending machine


(1) Click the machine which you want to setup.
(2) Edit parameter.
(3) Click the Register button.

(2)

(1)

(3)

40
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Explanation
Notify Process Please check in the case of the AMNC machine.
Object name Cannot edit.
Process Types Please select Bending.
Workcenter Please select BendingWorkCenter.
Machine Name Input the machine name. It is the machine name displayed on
vFactory.
PCLID Input the machine name. It is the name of the machine
management of SDD.
If customer is sharing the processing program with other
processing machines, please input the other machine name after a
semicolon.
When there is Dr.ABE Bend, please also input the machine name
which Dr.ABE Bend created data.
Ex) BEND0;HDS8025NT
3D Model ID Please input the identification name (model ID) of the machine of a
factory layout file.
Amada Type Please select Bend.
Image Please select what is suitable.
ST shots Do not edit.
StandardTime Please input the Working time for Bending. EX) 8H
Tonnage Input able tonnage
BendLength Input able bend length.
STThreshholdCaution Do not edit.
STThreshholdWarning Do not edit.

41
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

7.6. Setup other machine


(1) Click the machine which you want to setup.
(2) Edit parameter.
(3) Click the Register button.

(2)

(1)

(3)

Explanation
Notify Process Please check off.
Object name Cannot edit.
Process Types Please select None.
Workcenter Cannot edit.
Machine Name Input the machine name. It is the machine name displayed on
vFactory.
PCLID Cannot edit.
3D Model ID Please input the identification name (model ID) of the machine of a
factory layout file.
Amada Type Please select Other.
Image Please select what is suitable.

42
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

7.7. Create information file


(1) Set up the order of the machine displayed on vFactory. Please change by drag and drop.

(2) Select File -> CreateInformationFile .

(3) Click the Yes button.

Notice!
Please be sure to do CreateInfromationFile after changing a setup of Machine object.

43
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

7.8. How to connect to SDD (PCL or AP100 Server)


(1) Create the user for accessing to a SDD server. Please create in the SDD-J server PC.
User name: MAUI
Password: MAUI

(2) Set up Windows Firewall in SDD server.


If the Windows firewall is working with PC of SDD Server, please set up exception of
1433/TCP and a 1434/UDP port.

Open Windows Firewall setting widow.


[Start] -> [Control Panel] -> [Windows Firewall]

(a)

(b)

(a) Select the Exceptions panel.


(b) Click the Add Port button.

44
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(c) Setup Port number : 1433 (TCP).


Input “SQL (TCP)” into Name and input 1433 into Port number. Then click the OK
button.

(d) Setup Port number : 1434 (UDP).


Input “SQL (UDP)” into Name and input 1434 into Port number.
Select the UDP radio button. Then click the OK button.

45
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(3) Select the PCL Settings panel of vFactorySetup program.


Please input parameters. Click the Apply button after editing.

Explanation
Use PCL Check on, when connecting with SDD-J.
Host Name Input the PC name of SDD-J (PCL or AP100) which you want
to connect.
Account Name Input the user name of accessing SDD-J.
Password Input the password of accessing SDD. (PCL, AP100)
SQL Server SQL Server Ver6.5 -> Select Ver6.5.
SQL Server Ver7.0, MSDE1.0 or later. -> Select Ver7.0
SQL Server Account Name Input “SQLUSR”
SQL Server Password Input “sqlusr”
Measuring Unit Select mm or inch.

46
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

8. Setup Notification
8.1. Create event
An event is created by vFactorySetup.

(2)

(1)

(3)

(4)

(1) Right click the machine which you want to create an event and select Add Event.
(2) Select the notification type of an event from a pull down menu. And click the Confirm
button.
(3) Edit Title and Text field, if needed.
(4) Click the Register button.

* The example of a setting of the processing machine.


Power off
Stop – Alarm
Start processing

* The example of a setting of the L-UL machine.


Stop – Alarm

47
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

8.2. Create user


(1) Click the System settings button.
(2) Click Manager.
(3) Please input admin into the password of a dialog.

(2)

(3)
(1)

(4) Click the New user button.

(4)

48
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(5) Input user information. Please click the Register button, if inputs are completed.

(5)

User name : Input user name.


Email address : Input mail address of user.
Password : Input user’s password.
Send test email : You can send test e-mail.

(6) Click Return to the administrative control panel.

(6)

49
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

8.3. Register the item to notify to the newly registered user.


(1) Click the Event setup button at the bottom of the window.

(1)

(2) When users and notification items are displayed, check the desired items for each person,
and then click the Register button.

* Select what to notify to each e-mail recipient based on the model for which the recipient is
responsible.

(2)

50
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

8.4. Setting of notification conditions by the e-mail recipient


(1) Click the System settings button.

(2) When User is clicked, the password input window appears. Input the registered password,
and then click the OK button.

51
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(3) Click the event tab of notification items and select the item you want to enable e-mail
notification for.

(4) Click the schedule tab and set the time period during which you want to receive e-mail
notification.
After the following items have been set, click the Register button to complete the settings.

To cancel notification, access the window as the user and clear the Event notice check
box, and then click Register.

52
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

9. Setup camera
Notice
In order to use monitoring camera, it requires firmware version of UNIT-8 1.30 or later.
Please upgrade the firmware of UNIT-8, if the version is old.

(1) Log on to UNIT-8


Start Internet Explorer on your PC. Input http://192.9.200.155 in URL.
The screen which enters a user name and a password will appear. Input admin in Account
and password in Password, then logon.

(2) Create camera object.


Select the VIDEO panel.
Input the machine name in Parent area. (Machine name is the name registered into
MafuiFactory.)
Input the camera name in Name area. Confirm whether Video Pattern is Streaming.
After the modification, click the Apply button.

53
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Notice!
Please install an ActiveX control, when you set up.

54
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(3) Restart the UNIT-8 in order to enable change of the setup.


Select the MAINTAIN panel, then click the Shutdown button.

(4) Check a camera object.


Start the vFactorySetup program after the Unit-8 starts, check the camera object which you set
up exists or not.

55
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(5) Create information file.


(a) Select File -> CreateInformationFile .

(b) Click Yes.

(6) Click the connected machine from a vFactory main screen. Then, check whether the Live
View menu can be selected in the displayed window.

56
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

10. Setup vFactory Client


(1) Start Internet Explorer. Then input “htp://mauiserver/vfs” (http://the computer name/vfs) into
an address bar.

(2) After a while, the main screen of vFactory will appear. If you haven’t installed Orbit Viewer,
download it from vFactor server and install it.
Click screen according to an install message.

Click This website wants to install the following add-on: 'Virtual Factory 3D Viewer'
from 'Orbit Technology Corporation'. If you trust the website and the add-on and
want to install it, click here...

57
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

(3) Select Install ActiveX Control…

(4) Click the Install button.

(5) You can see the Virtual factory view.

58
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

11. IE8 settings


When you operate vFactory using IE8, please setup following steps.
If you start the Internet explorer ver8 first after WindowsUpdate, the next screen will appear.
Click the Next button.

Select the Yes, turn on Suggested Sites radio button. Then click the Next button.

59
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Select the Use express settings radio button. Then click the Finish button.

Start the Internet explorer. Select Compatibility View Settings from Tools menu.
Check on Display all websites in Compatibility View. Then click the Close button.

60
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Confirm the clock control will appear in the vFactory main screen.

If clock control will not appear, please recheck Compatibility View Settings.

61
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

12. IE9 settings (Optional)


When you operate vFactory using IE9, please setup following steps.
Start the Internet explorer. While pressing the [Alt] key, you can select the menu bar.
Select [Compatibility View Settings] from [Tools] menu.
Turn on the [Display all websites in Compatibility View] check box. Then click the [Close]
button.

62
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Confirm the clock control will appear in the vFactory main screen.

If clock control will not appear, please recheck [Compatibility View Settings].

63
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

13. Backup vFactory environment


Backup database by DBAdmin program.
[Start] -> [All Programs] -> [Maui Virtual Factory] -> [Stop Maui Virtual Factory]
The message [Press any key to continue...] is displayed, press ‘Enter’ key to close the
command prompt window.

[Start] -> [All Programs] -> [Maui Virtual Factory] -> [DB Admin]
Click localhost on the tree and click Backup Database.

64
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

The below dialog will appear.

Include New SDD database : Check on


Include files. When checked, this option will include all data files in the backup : Check OFF
Input Backup file name. Please input the name of a file as vfs.mauibk.
Select the Backup Now radio button.

Confirm Backup file name. Should be “vfs.mauibk”.


Click the Backup Now button. -> Backup processing will start.

vfs.mauibk

Click the OK button. Close the DBAdmin window.

65
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

[Start] -> [All Programs] -> [Maui Virtual Factory] -> [Start Maui Virtual Factory]
The message [Press any key to continue...] is displayed, press ‘Enter’ key to close the
command prompt window.

Start vFactory Setup program.


Click [Start] -> [All programs] -> [vFactory] -> [vFactorySetup].
Please input Maui into the column of the password. vFactorySetup program will appear.

66
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Select Backup Configuration from File menu.

Select Backup file name and location.


Check on Save vFactory layout file.
Then click the Execute button. -> Backup processing will start.

67
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Click the OK button.

68
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

14. Restore vFactory environment


Restore database by DBAdmin program.
[Start] -> [All Programs] -> [Maui Virtual Factory] -> [Stop Maui Factory]
The message [Press any key to continue...] is displayed, press ‘Enter’ key.

[Start] -> [All Programs] -> [Maui Virtual Factory] -> [DB Admin]
Click localhost on the tree and click Restore Database.

69
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Select Backup File dialog will appear.


Please select the file which you backed up. Click the Open button.

Confirm both check boxes (NewSDD and Maui) are on. Click the OK button.

Next, the below dialog will appear.


Select the Overwrite the existing database radio button.

70
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Click the OK button.

Next, the below dialog will appear.


Select the Overwrite the existing database radio button.

Click the OK button.

The restore processing will start.

71
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

The restore processing is finished, the below dialog will appear. Click the OK button.

Start vFactory Setup program.


Click [Start] -> [All programs] -> [vFactory] -> [vFactorySetup].
Please input Maui into the column of the password. vFactorySetup program will appear.

72
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Select Restore Configuration from File menu.

Select Backup file name.


Check on Restore vFactory layout file.
Then click the Execute button. -> Restore processing will start.

73
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Click the OK button.

Click the OK button.

Please click the Apply button of each vFactorysetup tab and reflect the contents of
restoration.

Note: A restoration result will not be reflected if you forget to click the Apply button with
each tab!

Select CreateInformationFile from File menu.

74
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X

Click the Yes button.

75
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.

You might also like