Professional Documents
Culture Documents
Vfactory Test Run Manual For Ver3.40.0X
Vfactory Test Run Manual For Ver3.40.0X
For Ver3.40.0X
Modify History
Author
Rev. Date Content
Company Name
1 2010/11/10 AMADA K.Shinoda For Ver3.40.0X
2 2011/05/18 AMADA K.Shinoda For Windows server 2008R2
vFactory test run manual For Ver3.40.0X
Table of Contents
Introduction .......................................................................................... 3
1. Check MauiFactory ......................................................................... 4
2. How to connect to AMNC-F ............................................................ 5
3. UNIT-8 Setting ................................................................................ 8
4. How to Connect to AMNC Bender Ver4........................................ 15
5. How to Connect to AMNC Bender Ver5........................................ 20
6. Make and install a factory layout................................................... 34
7. Setup vFactory .............................................................................. 35
8. Setup Notification .......................................................................... 47
9. Setup camera ................................................................................ 53
10. Setup vFactory Client ................................................................. 57
11. IE8 settings ................................................................................. 59
12. IE9 settings (Optional) ................................................................ 62
13. Backup vFactory environment .................................................... 64
14. Restore vFactory environment ................................................... 69
2
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Introduction
This manual is described of the work sequence at the time of supplying and making a test run
of vFactory.
Start
3
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
1. Check MauiFactory
Log on to MauiFactory and check whether MauiFactory is working correctly.
4
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Notice
The IP address of vFactory is inputted during installation. First, please examine the IP
address of vFactory.
After opening the interface of AMNC-F, press Ctrl and Esc at the same time to display start
menu. Press Ctrl, then click the icon of AMNC Daemon.
5
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Enable : If you want to connect to vFactory, turn on the check mark in the checkbox.
IP Address : Input the IP address of vFactory computer.
Machine Name : Input the machine name which you want to register to vFactory.
FMS : When the FMS controller is connected, turn on the check mark in the
checkbox.
IP Address : Input the IP address of FMS controller.
6
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Log on to MauiFactory after the AMNC-F starts. Check the machine object which you set up
exists in MauiFactory or not.
7
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
3. UNIT-8 Setting
In this chapter, we will talk about how to use UNIT-8, that is, the method of connecting ordinary
machine to vFactory.
Example: The old NCT (COMA, PEGA, VIPROS) and L/UL Device.
We can set up Unit-8 with the PC connected by LAN. UNIT8 has the server function of WWW,
and we can set the parameter by Internet Explorer.
Notice
Recommend to use the later version of Ver5.5SP1 of Internet Explorer.
(1) Start Internet Explorer and select the Internet options of Tools menu.
(2) Select the Security tab.
(3) Select the Trusted sites.
(4) Click the Sites button.
(2) Select the Security (3) Select the Trusted
tab. sites.
8
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(5) Input the IP address of UNIT8 in Add this site to the zone:.
(6) Click the Add button.
(7) Turn off the check box of Require server verification (https:) for all sites in this zone.
(8) Click the Close button.
The screen which enters a user name and a password will appear. Input admin in Account
and password in Password, then logon.
9
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Select the NETWORK page. Please modify the web item according to the customer
environment. After the modification, click the Apply button.
10
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Select the SYSTEM panel. Then click the Setup button on Time Setup.
11
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
[Explanation]
Channel Name
Input Channel’s name. vFactory regards the following five words as key words.
POW : Power ON
RUN : Working
SET : Setting
ALM : Alarm active
CNT : Count. Calculate the shot quantity of the bender.
* The signal name of each machine is described on the drawing of each connection kit.
Parent Name
Input the name of Parent object. The default name is f01.
Unit Name
Input the connected machine name.
12
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Reverse
If you want to reverse and output the inputted signal logic, turn on a check mark in the
checkbox.
On-Delay, OFF-Delay
Input when we need ON-Delay and Off-Delay. Signal’s ON and OFF will delay according to the
inputting second.
13
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Log on to MauiFactory after the Unit-8 starts. Check the machine object which you set up
exists in MauiFactory or not.
14
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Notice
* It needs a keyboard for installation. Please start the AMNC bender after connecting a
keyboard.
* If EWF machine, please install after cancel protection.
* Installation should use the installer corresponding to the version of AMNC.
15
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Input the IP address of the vFactory computer, then click the NEXT button.
16
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Input the machine name to register to vFactory. Then click the NEXT button.
17
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
18
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Notice
It is necessary to change a parameter or later the AMNC bender Ver4.08.03.
Log on to MauiFactory after the AMNC bender starts. Check the machine object which you set
up exists in MauiFactory or not.
19
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
20
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(3) The screen of a password will appear. Input “14789632”, then push the enter button.
21
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(4) Change the parameter No.32 into 1 from 0. Then push the EXIT button.
22
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
When push the EwfMgr operate button, the next screen will appear.
(b)
(c)
(a)
23
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Notice
When you turn off the power, please be sure to make oil pressure into "OFF."
(5) If the AMNC bender is started again, the following dialog message will appear.
Push the No button will start AmncV5.
24
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(6) After the AmncV5 starts, please check whether the mark of the key in the screen upper
right is blinking.
When the mark of a key is not blinking, please redo the work of 5.3 Disable EWF function.
25
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
After the modification, push the save button to save ini file.
26
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
27
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(3) Change the system parameter No74 into 1. Then push the EXIT button.
28
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(b)
(c)
(a)
29
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Notice
When you turn off the power, please be sure to make oil pressure into "OFF."
30
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
31
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(3) Change the parameter No.32 into 0 from 1. Then push the EXIT button.
32
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
33
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Please save the layout which you created by the name f01.ovf at the following folder.
Other OS
C:¥Program Files¥Amada¥VPSS¥vFactory¥web¥vfsj¥layout¥f01¥OrViewer
Notice!
* Please be sure to save in a lower case character.
* Please refer to another document for operation of LayoutTool software.
34
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
7. Setup vFactory
7.1. Start vFactory Setup program
Click [Start] -> [All programs] -> [vFactory] -> [vFactorySetup].
Please input Maui into the column of a password. vFactorySetup program will appear.
35
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Please input a customer's company name into the column of Server Name.
Other columns are the items set up when using the notification function of E-mail.
Please click the Register button after edit. Click the Yes button.
36
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Explanation
Server Name Input the customer company name.
Email SMTP Server Input the customer’s SMTP server name.
Port No. If the provider is doing Outbound Port 25 Blocking control,
please input the port number.
Email SMTP Account Name Input the customer’s SMTP account name.
Email SMTP Account Password Input the customer’s SMTP password.
Email Return Address Input the customer’s mail address.
Email Charset Please select what is suitable.
Email Interface Enable Do not edit.
Email POP Server Do not edit.
Email Account Name Do not edit.
Email Account Password Do not edit.
POP before SMTP Do not edit.
POP before SMTP TimeOut Do not edit.
37
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(1) (2)
(3)
(4)
38
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(2)
(1)
(3)
Explanation
Notify Process Please check in the case of the AMNC machine.
Object name Cannot edit.
Process Types Please select Cutting.
Workcenter Please select CuttingWorkCenter.
Machine Name Input the machine name. It is the machine name displayed on
vFactory.
PCLID Input the machine name. It is the name of the machine management
of SDD.
If customer is sharing the processing program with other processing
machines, please input the other machine name after a semicolon.
Ex) EM3510NT;EML3510NT
3D Model ID Please input the identification name (model ID) of the machine of a
factory layout file.
Amada Type Please select what is suitable.
NCT : NCT, Hybrid : Combi machine. ex) EML. Laser: Laser
Image Please select what is suitable.
39
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(2)
(1)
(3)
40
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Explanation
Notify Process Please check in the case of the AMNC machine.
Object name Cannot edit.
Process Types Please select Bending.
Workcenter Please select BendingWorkCenter.
Machine Name Input the machine name. It is the machine name displayed on
vFactory.
PCLID Input the machine name. It is the name of the machine
management of SDD.
If customer is sharing the processing program with other
processing machines, please input the other machine name after a
semicolon.
When there is Dr.ABE Bend, please also input the machine name
which Dr.ABE Bend created data.
Ex) BEND0;HDS8025NT
3D Model ID Please input the identification name (model ID) of the machine of a
factory layout file.
Amada Type Please select Bend.
Image Please select what is suitable.
ST shots Do not edit.
StandardTime Please input the Working time for Bending. EX) 8H
Tonnage Input able tonnage
BendLength Input able bend length.
STThreshholdCaution Do not edit.
STThreshholdWarning Do not edit.
41
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(2)
(1)
(3)
Explanation
Notify Process Please check off.
Object name Cannot edit.
Process Types Please select None.
Workcenter Cannot edit.
Machine Name Input the machine name. It is the machine name displayed on
vFactory.
PCLID Cannot edit.
3D Model ID Please input the identification name (model ID) of the machine of a
factory layout file.
Amada Type Please select Other.
Image Please select what is suitable.
42
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Notice!
Please be sure to do CreateInfromationFile after changing a setup of Machine object.
43
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(a)
(b)
44
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
45
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Explanation
Use PCL Check on, when connecting with SDD-J.
Host Name Input the PC name of SDD-J (PCL or AP100) which you want
to connect.
Account Name Input the user name of accessing SDD-J.
Password Input the password of accessing SDD. (PCL, AP100)
SQL Server SQL Server Ver6.5 -> Select Ver6.5.
SQL Server Ver7.0, MSDE1.0 or later. -> Select Ver7.0
SQL Server Account Name Input “SQLUSR”
SQL Server Password Input “sqlusr”
Measuring Unit Select mm or inch.
46
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
8. Setup Notification
8.1. Create event
An event is created by vFactorySetup.
(2)
(1)
(3)
(4)
(1) Right click the machine which you want to create an event and select Add Event.
(2) Select the notification type of an event from a pull down menu. And click the Confirm
button.
(3) Edit Title and Text field, if needed.
(4) Click the Register button.
47
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(2)
(3)
(1)
(4)
48
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(5) Input user information. Please click the Register button, if inputs are completed.
(5)
(6)
49
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(1)
(2) When users and notification items are displayed, check the desired items for each person,
and then click the Register button.
* Select what to notify to each e-mail recipient based on the model for which the recipient is
responsible.
(2)
50
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(2) When User is clicked, the password input window appears. Input the registered password,
and then click the OK button.
51
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(3) Click the event tab of notification items and select the item you want to enable e-mail
notification for.
(4) Click the schedule tab and set the time period during which you want to receive e-mail
notification.
After the following items have been set, click the Register button to complete the settings.
To cancel notification, access the window as the user and clear the Event notice check
box, and then click Register.
52
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
9. Setup camera
Notice
In order to use monitoring camera, it requires firmware version of UNIT-8 1.30 or later.
Please upgrade the firmware of UNIT-8, if the version is old.
53
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Notice!
Please install an ActiveX control, when you set up.
54
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
55
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(6) Click the connected machine from a vFactory main screen. Then, check whether the Live
View menu can be selected in the displayed window.
56
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
(2) After a while, the main screen of vFactory will appear. If you haven’t installed Orbit Viewer,
download it from vFactor server and install it.
Click screen according to an install message.
Click This website wants to install the following add-on: 'Virtual Factory 3D Viewer'
from 'Orbit Technology Corporation'. If you trust the website and the add-on and
want to install it, click here...
57
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
58
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Select the Yes, turn on Suggested Sites radio button. Then click the Next button.
59
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Select the Use express settings radio button. Then click the Finish button.
Start the Internet explorer. Select Compatibility View Settings from Tools menu.
Check on Display all websites in Compatibility View. Then click the Close button.
60
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Confirm the clock control will appear in the vFactory main screen.
If clock control will not appear, please recheck Compatibility View Settings.
61
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
62
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Confirm the clock control will appear in the vFactory main screen.
If clock control will not appear, please recheck [Compatibility View Settings].
63
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
[Start] -> [All Programs] -> [Maui Virtual Factory] -> [DB Admin]
Click localhost on the tree and click Backup Database.
64
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
vfs.mauibk
65
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
[Start] -> [All Programs] -> [Maui Virtual Factory] -> [Start Maui Virtual Factory]
The message [Press any key to continue...] is displayed, press ‘Enter’ key to close the
command prompt window.
66
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
67
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
68
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
[Start] -> [All Programs] -> [Maui Virtual Factory] -> [DB Admin]
Click localhost on the tree and click Restore Database.
69
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Confirm both check boxes (NewSDD and Maui) are on. Click the OK button.
70
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
71
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
The restore processing is finished, the below dialog will appear. Click the OK button.
72
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
73
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
Please click the Apply button of each vFactorysetup tab and reflect the contents of
restoration.
Note: A restoration result will not be reflected if you forget to click the Apply button with
each tab!
74
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.
vFactory test run manual For Ver3.40.0X
75
C Copyright 2003-2011 AMADA Co.,LTD. All rights reserved.