Professional Documents
Culture Documents
HAT Reen Uilding: Pdate Ourse
HAT Reen Uilding: Pdate Ourse
Learning Objective: Upon completing this section, licensees should have a better
understanding of the primary rating standards used in the United States to certify structures as
energy efficient or green and the distinction between a structure that has been certified as “energy
efficient” versus a structure that has been certified as “green” or “green built.”
INTRODUCTION
In recent years, an increasing percentage of the population has become more aware of and
concerned about various environmental and ecological issues, including stewardship of our
natural resources and man’s impact on his surroundings. This increased sensitivity and
awareness has spurred some consumers to assess factors such as energy efficiency and
environmental impact when comparing various products to purchase and has prompted some
vendors to engage in “greenwashing.” The EPA defines “greenwashing” as “[T]he practice of
advertising a product or process as “green” or environmentally friendly, when the product
really is not, or does not achieve the advertised marketing claims. A false or misleading picture
of environmental friendliness used to conceal or obscure damaging activities.”
It has only been within the past two to three decades that attempts have been made to
qualify or define what is meant by labels such as “energy efficient” and “green built” to provide
guidelines for industry and consumers. This section will explore those labels — what they
mean, by what measurement standards, and who certifies compliance. Why? It is important
that licensees understand that certain terms may have a specific meaning and licensees must
use such terms accurately and appropriately when marketing or describing a property’s
features to avoid negligent misrepresentations. While numerous “green” standards may exist,
whether at the international, state or local level, this Section will mention what are believed to be
-1-
the primary evaluation standards used in the United States to assess energy efficiency, as well as
green construction in residential and commercial structures. The common elements of the
various standards discussed herein are that they were all developed by consensus and require
third party verification of compliance to be certified at any given level.
This section will not explore the evolution of the green/energy efficient movement, nor
provide an economic assessment of the cost/benefits of utilizing energy efficient or green
building concepts, nor review various financial incentives available to consumers, of which there
are many. There are numerous resources available to licensees who are interested in
learning more about energy efficiency, green building, sustainability and renewable energy
sources, including various Real Estate Commission approved continuing education courses
on these topics ranging from 4 to 8 hours, longer courses offering specific designations in
this area, and a host of websites providing a wealth of information, some of which are
referenced at the end of this section.
BACKGROUND
Social consciousness in the United States concerning “green” considerations in buildings
and lifestyles began emerging in the 1960s and 1970s, spurred in part by the spike in oil prices in
the 1970s, coupled with a growing environmental movement that championed conservation,
stewardship of resources, and consideration of alternate renewable energy sources, rather than
reliance on traditional depletable fossil fuels. Various entities, both governmental and private,
engaged in research to explore ways of improving energy efficiency and to find and harness
sources of renewable energy. While the primary research focus originally was energy efficiency,
some pioneers began experimenting with contemporary green building concepts.
Nonetheless, it was not until the early 1990s that formal attempts were made to develop
standards that could be applied more objectively to evaluate how energy efficient a product or
structure was and what minimum standards must be met before a structure could be called
“green.” These early attempts to promulgate guidelines or standards included the following:
! The American Institute of Architects (AIA) formed a Committee on the Environment in
1989 and published an Environmental Resource Guide in 1992, funded in part by the
Environmental Protection Agency;
! The U.S. Environmental Protection Agency (EPA) in conjunction with the U.S.
Department of Energy (DOE) introduced the ENERGY STAR program in 1992.
! The U.S. Green Building Council (USGBC) was founded in 1993 and published its first
version of Leadership in Energy and Environmental Design (LEED) in 1998.
! The National Association of Home Builders (NAHB), which had introduced the term
“green building” in the 1980s, formed a Green Building Subcommittee in 1998, held its
first annual green building conference in 1999, and developed the Model Green Home
Building Guidelines in 2006.
-2-
The federal government also initiated several programs during the first decade of this
century promoting energy efficient and sustainable building practices in federal buildings. This
history is contained in a report by the Office of the Federal Environmental Executive titled “The
Federal Commitment to Green Building: Experiences and Expectations” which may be found on
the EPA’s website. The EPA formed a Green Building Workgroup in July 2003 to consolidate
the various programs within the Agency that worked with builders and developers to improve
environmental performance. It issued its “Green Building Strategy” in 2008 to guide the
Agency’s green building initiatives.
The common threads linking all of these initiatives regardless of source were improving
energy efficiency to reduce greenhouse gas emissions and the corresponding “carbon
footprint” while realizing economic savings from decreased utility costs over the life of the
product and conserving our non-renewable energy resources, e.g., fossil fuels.
The most abundant naturally occurring “greenhouse gases” in order of their prevalence
are:
! water vapor (H2O)
! carbon dioxide (CO2)
! methane (CH4)
! nitrous oxide (N2O)
! ozone (O3)
While the foregoing gases are naturally present in our atmosphere, they also result from human
activities. For example, both carbon dioxide and nitrous oxide are emitted into the atmosphere
whenever solid waste or fossil fuels (oil, coal and natural gas) are burned. Burning wood
products releases carbon dioxide. Methane is released whenever organic waste decomposes,
whether in landfills or as a result of livestock farming, as well as during the production and
transport of fossil fuels. Both carbon dioxide and methane are colorless and odorless (but
methane is flammable). Nitrous oxide is colorless, but has a sweet odor, and is released from
the production of livestock feed containing large amounts of nitrogen based fertilizers, as well as
from livestock waste.
Understand that not all greenhouse gases are equal in their heat-retaining capabilities.
HFCs and PFCs are the most heat-absorbent gases and are sometimes referred to as High Global
Warming Potential gases (high GWP gases), but in the naturally-occurring category, nitrous
oxide absorbs 270 times more heat per molecule than carbon dioxide, and methane absorbs 21
times more heat per molecule than carbon dioxide, although carbon dioxide still accounts for
60% of the greenhouse effect.
The last complete energy conservation code formulated by the ICC is the 2009
International Energy Conservation Code (IECC), although it is being revised in 2012. The
2009 IECC was the springboard for the most recent North Carolina Energy Conservation
Code (NCECC) promulgated in late 2010 and effective January 1, 2012. The 2012 NCECC
used the 2009 IECC as a guide, but is not identical, as the NCECC contains amendments and
revisions that are specific to North Carolina. The new Code requires improved insulation levels,
window performance and building envelope air leakage reduction. The North Carolina Code
also includes a “High Efficiency Residential Option” (HERO) appendix that delivers 15-20%
more energy efficiency than the base 2009 IECC. Reducing one’s energy consumption by 15%
is equivalent to parking your car for two months, or planting 200 trees.
-4-
How Rating Determined
A HERS rating is a number that indicates the energy efficiency of a home and has been
likened to the “miles per gallon” ratings for automobiles. The rating is determined by dividing
the projected energy consumption of the subject home by the projected energy consumption of a
reference home and multiplying by 100. The “reference home” is a home of the same
dimensions in the same climate zone that is built in compliance with the standards of the model
energy code and has an assigned HERS index of 100. The software used to calculate the energy
consumption of a home considers the areas and insulation values of the walls, windows, ceilings,
floors, etc. (often referred to as “the thermal envelope”), the efficiency of the heating, cooling
and hot water systems, the lighting systems, the appliances, and energy loss through air
infiltration and duct leakage.
Under HERS, homes are rated on a scale of 0-150 with the reference home rated at 100.
Most existing homes fall between 120-150. In residential evaluations, the higher the
number, the less efficient the structure. Each point on the scale is equivalent to a 1%
reduction in energy consumption. Thus, a house with a HERS rating of 70 would be 30% more
energy efficient than the reference home built according to the applicable energy code and 70%
more efficient than an existing home with a 140 HERS rating. HERS raters often will conduct a
“Blower Door test” as well as duct blasting tests to gauge how tight a house is sealed. HERS
certified raters are used by various programs to determine eligibility for certifications, including
both ENERGY STAR and the NAHB’s National Green Building Standards program. NOTE
however, that a property may have a HERS rating but not be certified as either ENERGY STAR
Qualified or “green-built.”
According to the EPA’s 2010 ENERGY STAR report, the program now encompasses
more than 40,000 products in more than 60 categories including major appliances, office
equipment, lighting, home electronics, and heating and cooling systems. Additionally, the
ENERGY STAR program has established energy performance rating systems for new homes,
existing homes, commercial and institutional buildings, as well as manufacturing facilities.
Note that ENERGY STAR focuses SOLELY on assessing energy efficiency and performance.
It does not evaluate other aspects or features typically considered in “green building” that will be
discussed later. Information concerning the rating standards for any given category or product
may be found at www.energystar.gov.
-5-
The ENERGY STAR website frequently refers to “green building” or “green homes”
which, unfortunately, may give the public the impression that ENERGY STAR certification
means a building is “green-built,” which technically is not true. The criteria for qualifying a
structure as “green-built” go far beyond considerations of energy efficiency alone. The
ENERGY STAR website acknowledges this reality in subtle statements such as “energy
efficiency is the place to start” when looking for a green home and that a homeowner will have
addressed “two critical green home elements” when purchasing an ENERGY STAR Qualified
home that is also certified under ENERGY STAR’s IndoorairPlus standard that assesses indoor
air quality.
Residential Structures
Any residential structure three stories or less may apply for ENERGY STAR
certification including (per EPA’s website): “site-constructed homes, attached or detached
homes, single or low-rise multi-family buildings, manufactured homes, systems-built homes (e.g.,
SIP or modular), log homes, existing homes, or retrofitted homes.” A home may qualify for an
ENERGY STAR rating by following a “Prescriptive Path” if it meets or is less than the
“Benchmark Home Size.” The benchmark home size currently is 1000 square feet for a one
bedroom home, and adds 600 square feet for each additional bedroom, e.g., 2 bedrooms = 1600
SF, 3 bedrooms = 2200SF, etc. If the “conditioned floor area” (square footage) exceeds the
benchmark home size, then the home must qualify via the “Performance Path.” The
Performance Path utilizes energy modeling to determine an ENERGY STAR HERS Index Target
which is different for each home and depends on the size, location and orientation of the subject
home.
-6-
performing satisfactorily according to the standards required by whatever ENERGY STAR
Version was applied to evaluate the home. There have been at least 4-5 versions of the
standards and the ENERGY STAR label will indicate certification under a particular ENERGY
STAR Version X. ENERGY STAR Version 3.0 rating criteria was just released and became
effective January 1, 2012. Each successive version establishes more stringent standards.
Copies of the current and prior ENERGY STAR Versions may be found at www.energystar.gov.
Residences for which permits were first issued after 1/1/2012 must comply with Version
3.0. Structures initially permitted between 4/1/2011 and 12/31/2011 may be qualified under
ENERGY STAR Version 2.5 IF the final inspection occurred prior to July 1, 2012. If the final
inspection occurred after July 1, 2012, the structure must satisfy Version 3.0 standards to be
qualified. Thus, as a practical matter, all homes seeking ENERGY STAR certification must
now satisfy ENERGY STAR Version 3.0 standards. If granted, the ENERGY STAR label is to
be affixed to the circuit breaker box in the home and the Certificate of qualification under
ENERGY STAR Version 3.0 (at present) is given to the owner. The energy efficiency of a home
constructed in compliance with both the 2012 NCECC and the optional High Efficiency
Residential Option (HERO) is believed to be comparable to that of a home certified under
ENERGY STAR Version 3.0.
According to the national ENERGY STAR website, any residential property bearing the
ENERGY STAR label will possess the following characteristics.
1. Effective Insulation. The floors, walls and attic will have been inspected to ensure that
not only was the proper grade of insulation used, but that it was properly installed as
well. “Proper installation” requires that the insulation be in contact with all surrounding
surfaces, front, back, top, bottom, and both sides, to be fully effective. Effective
insulation promotes uniform temperatures throughout the house, physical comfort, and
reduced energy costs.
3. Tight Construction and Ducts. Perhaps one of the most important factors in achieving
energy efficiency is a well built, well-sealed home. Energy efficient appliances or
HVAC systems cannot offset a house that’s built like a sieve. Thus, sealing around all
openings (doors, windows, ductwork, recessed light canisters, cracks, etc.) within the
structure’s “envelope” is critical to reduce, if not eliminate, leaks, drafts, moisture, dust,
pollen and noise. A tightly sealed structure with controlled air exchanges maximizes
energy efficiency, thereby reducing utility bills, and substantially improves both comfort
and indoor air quality. The standards also require the rater to assess the adequacy of the
flashing and moisture barriers to keep water from roofs, walls and foundations to improve
both durability and indoor air quality.
-7-
4. Efficient Heating and Cooling Equipment. While a tightly sealed house will require
less heating and cooling because less energy is escaping, the HVAC system in an
ENERGY STAR qualified home must also be energy efficient. Such systems cost less to
operate, are quieter, reduce indoor humidity, improve the comfort of the home, and often
are more durable, requiring less maintenance than standard models.
5. Lighting and Appliances. While ENERGY STAR qualified homes most likely will
also have other ENERGY STAR certified products, such as refrigerators, stoves,
dishwashers, washing machines, lighting fixtures, ventilation fans and compact
fluorescent bulbs, all of which would result in even greater energy efficiency, it does not
appear that such features are absolutely required, if a home otherwise meets the stated
energy efficient standards.
Commercial Buildings
Commercial buildings may also qualify for ENERGY STAR certification through the
ENERGY STAR Commercial Builders Program, although the criteria are not as exact or
precise as those established for the residential certification process. In the commercial/industrial
arena, the ENERGY STAR website offers a “Portfolio Manager,” a tool that allows managers of
certain types of buildings to input various information concerning the property and obtain an
energy performance score. This rating is calculated on a scale of 1 to 100 based on surveys of
similar buildings in the national population. The peer group is identified through the
Commercial Building Energy Consumption Survey (CBECS) conducted every four years by the
Department of Energy.
The survey gathers information from those who agree to participate and submit the
requested information regarding actual energy consumption of buildings in various categories
and the scale is then devised from this information for the next four years. A score of 50 means
the building is performing energy-wise at the industry average. Contrary to the rating system
for residential buildings where lower scores are more energy efficient, when rating commercial
buildings the higher the score the more energy efficient the building is. A score of 75 or
higher is required to obtain an ENERGY STAR label for a commercial building. The
factors considered in the equation are the type of building, its operating characteristics, and its
energy data. Presumably, the benchmark will continually rise as more and more commercial
structures improve their energy efficiency, thereby increasing the “industry average” in a given
category.
-8-
Type of Building
To be eligible to obtain an energy performance rating, more than 50% of the building’s
gross floor space, excluding parking lots and garages, must fall within one of the following
fifteen categories, namely:
Several other limitations may also apply depending on what other space types are within the
building that do not fall in the primary use category, but these additional limitations are detailed
and well beyond the scope of this discussion. One enters data into the Portfolio Manager tool
concerning key operating characteristics for each space use in one’s building. The standards set
minimum and maximum thresholds for certain values to “make sure that your building falls into
an operation pattern consistent with that of the peer group used for comparison.” One example
of a threshold minimum is a requirement that:
1) all buildings minimally must have 5000 square feet except: a) banks and houses of
worship may be as small as 1000 square feet; b) hospitals must be at least 20,000 square
feet; and c) data centers have no minimum square footage requirements;
and
2) the facility must be in operation at least 30 hours per week except a) houses of worship
and b) buildings for which no hours of operation are requested, e.g., hospitals and hotels.
To obtain an energy performance rating, one must input energy data from all active meters for an
11 consecutive month period.
New Home Construction: 126,000 ENERGY STAR Qualified homes were built in
2010, representing 25% of housing starts in the United States. Total ENERGY STAR
Qualified homes increased from approximately 25,000 in 2000 to more than 1.2 million
as of 2010 and the number of ENERGY STAR building partners increased from 1600 in
2000 to 8400 in 2010.
-9-
Home Improvement: The ENERGY STAR home performance improvement program
was implemented in 2001 or 2002. In 2010 alone 35,000 homes were retrofitted through
this program, bringing the total to 110,000 homes. This program is being transferred
from EPA management to the Department of Energy. The EPA offers an online Home
Energy Yardstick that allows owners to compare their home’s energy use to that of others
across the country. Nearly 100,000 consumers used this interactive tool in 2010.
Total estimated utility savings from all ENERGY STAR products in 2010 was $20 billion,
resulting in reduced greenhouse gas emissions equivalent to 38 million vehicles.
GREEN BUILDING
While energy efficiency is a key component of a green built structure, the requirements to
be certified as “green built” go well beyond energy efficiency alone. Thus one could say that all
green built structures will be energy efficient, but not all energy efficient buildings are “green
built.” The EPA launched a Green Building Strategy in 2008 the purpose of which is to
“facilitate the mainstream adoption of effective green building practices” through public
education and strengthening the scientific, technical, economic and institutional foundations of
green building.
Traditionally, building codes have focused more on human safety and how the
environment affects buildings. Green building standards consider how buildings impact or
affect the environment. Buildings account for almost 40% of the total energy usage in the
United States and 68% of total electricity consumption. They generate 40% of the national
carbon dioxide emissions and consume 12% of the freshwater usage.
The EPA defines “green building” as, among other things, “the practice of creating
structures and using processes that are environmentally responsible and resource-efficient
throughout a building’s life cycle from siting to design, construction, operation, maintenance,
renovation, and deconstruction. This practice expands and complements the classical building
design concerns of economy, utility, durability and comfort. Green building is also known as a
sustainable or high performance building.”
The goal of green building is to reduce the overall impact of buildings on the natural
environment and human health by:
-10-
! efficiently using energy, water, and other resources;
! reducing waste, pollution and environmental degradation; and
! protecting occupant health and improving employee productivity.
The environmental benefits include protecting biodiversity and ecosystems, improving air
and water quality, reducing waste streams, and conserving and restoring natural resources.
Economic benefits include reduced operating costs, optimizing life-cycle economic performance,
improved occupant productivity, and expanding markets for green products and services. While
green building concepts may be integrated into buildings at any stage, the most significant
benefits are realized when the design and construction teams take an integrated approach at the
outset of a building project.
Note that renovations and additions to existing residences, which comprise approximately 90%
of the housing market, may now be rated, as well as new construction. The NGBS criteria rate
buildings in six categories, namely:
1) lot and site development that minimizes disruptions and preserves open space;
-11-
2) resource efficiency considers materials and techniques used, such as wood alternatives,
recycled building materials, and sustainably harvested lumber, as well as the local
availability of these materials and costs to transport;
3) energy efficiency reviews the level of insulation used, the efficiency of the HVAC
systems, and the presence of energy efficient appliances, lighting, and high performance
windows;
4) water efficiency/conservation assesses use of water-efficient appliances and fixtures,
filtration systems, as well as whether the landscaping is low maintenance or drought
resistant;
5) indoor environmental quality considers the HVAC equipment, formaldehyde-free
finishes, low-allergen materials, and use of products with minimum off-gassing or low
volatile organic compounds (VOCs);
6) homeowner education through manuals and operating guides.
A minimum number of points must be scored in each category in order to receive one of
four green certifications - either bronze, silver, gold or emerald, with bronze being the lowest
and emerald the highest certification. While there are some mandatory requirements that must
be satisfied, the standards prefer to give designers, builders and owners a range of options or
features from which to choose with each option having a corresponding point value. The
specifications are incredibly detailed and complex and will not be reviewed here. However, the
energy efficiency component of the rating must exceed the standards set in the 2009 International
Energy Conservation Code for each level as follows: Bronze - 15% more efficient; Silver = 30%
more efficient; Gold = 50% more efficient, and Emerald = 60% more efficient.
-12-
2) water efficiency: encourages more efficient appliances, fixtures and fittings inside and
water-conscious landscaping outside.
4) materials and resources: encourages use of sustainably grown, harvested, produced and
transported materials and reducing waste through reuse and recycling.
5) indoor environmental quality: promotes strategies that improve indoor air and provide
access to natural light, outdoor views and improved acoustics.
There are a total of 100 base points maximum from the above five categories. Additionally, a
maximum of six points may also be earned in the optional Innovation in Design category which
addresses sustainable building expertise as well as design measures not covered under the first
five categories and rewards projects for including a LEED Accredited Professional on the team.
The standards also allow up to four points in the other optional “regional credits” category for
projects that address environmental issues facing their region. The LEED rating system is
scheduled to be reviewed and possibly updated in 2012. The four current levels of LEED
certification and the points necessary to attain each level are: Certified = 40 - 49 points; Silver =
50 - 59 points; Gold = 60 - 79 points; Platinum = 80 points or more.
Green Globes
Green Globes provides an alternate certification program to LEED. It was introduced to
the United States by the Green Building Initiative (GBI) in 2004 and is patterned after a
Canadian green building rating system that was first developed in the United Kingdom and
known as BREEAM, Building Research Establishment Environmental Assessment Method. In
the United States, Green Globes offers two assessment tools, one for new construction that has
been available since 2005, and a recently introduced evaluation tool for Continual Improvement
of Existing Buildings (CIEB). Both are intended to evaluate commercial buildings, rather than
residential. The Green Building Initiative was accredited as a standards developer by the
American National Standards Institute in 2005 and is in the process of seeking ANSI approval of
its Green Buildings Assessment Protocol for Commercial Buildings.
-13-
Green Globes is touted as being more user-friendly and easier than LEED certification.
It is a web-based interactive green building assessment tool that is questionnaire-driven. Users
answer a series of questions with a combination of yes/no, not-applicable, multiple choice or date
insertion responses. Questions become more complex as one proceeds through the assessment.
Upon completing the questionnaire, the system generates a written report with suggested
improvements and references to supplemental information. Online training is available on
GBI’s website (www.thegbi.org) or personal training may be arranged for a fee.
CONCLUSION
Almost any building, whether new or existing, residential or commercial, is now capable
of being rated as to how energy efficient it is, and whether it is eligible for a “green built”
certification. Questions to ask include not only what rating standards were utilized, but what
version of those standards, who performed the certification, what the resulting score was and
what documentation exists to verify the certification. All of the rating programs discussed
herein require compliance certification by third party verifiers, although the educational
background and training of those verifiers will vary depending on what agency or group is
issuing the approval. Credentialing requirements for any given program may be found on the
approving body’s website.
Certification under any program will entail certain fees or costs, depending on the
program. All focus on a total systems approach, recognizing that each system supports and
affects other systems for an integrated unified building. The most critical features of a building
that impact how energy efficient it is are how well sealed it is around all openings (doors,
windows, walls, ducts, light fixtures, exhaust vents, etc.), appropriate grade insulation properly
installed, efficient heating and cooling systems and high performance windows. Licensees
should be mindful that while energy efficiency is one of the primary goals of green building, an
energy efficient building may not necessarily be green built. Licensees should choose their
words carefully in describing the attributes of any given property. As previously stated, all
green built structures will be energy efficient, but not all energy efficient structures may be
certified as “green built.”
-14-
Licensees must understand the significance of and difference between these “terms of art”
and use them correctly. Before a licensee makes any assertions (a.k.a. “representations”) about
a property or its features in any forum, the licensee should request written verification of the
ENERGY STAR or green built certification from the owner. The certification should answer
the above questions as to what version of whose standards were applied and who certified
compliance. As with most important documentation, a prudent licensee will retain a copy of the
certification in his/her transaction file, even if not technically required by the record retention
rule. While new construction, whether residential or commercial, either qualifies or doesn’t as
energy efficient or green built, structures that have been renovated, remodeled or additions made
may not be as easy to rate or describe. Having a copy of the applicable certification in the
transaction file evidences reasonable discovery by a licensee and helps dispel doubt.
One example of a LEED certified building of which some licensees may be aware is the
National Association of REALTORS® building in Washington DC. Additionally, appended
hereto is a description of some of the sustainability features incorporated into the North Carolina
American Institute of Architects’ Center for Architecture and Design located in Raleigh, NC
(www.cfadnc.org) that has applied for a platinum LEED certification, as well as features
incorporated into the Wells Fargo Duke Energy Center building in Charlotte, which has a
platinum LEED certification.
-15-
Lastly, licensees (or at least REALTOR members) should be aware that some MLS
organizations have incorporated a “Green Fields” category within TEMPO. It is believed that
the Triangle, Triad and Charlotte MLS systems have this field available. Reprinted is the cover
page from Green Fields. Explanations of the “Green Building Features,” “Green Building
Certifications,” and “Green Building HERS Rating” are further explained within the TEMPO
program, but are not reprinted herein. NAR also offers various green certification programs and
initiatives, such as “Greening the MLS” to its members.
Recommended Websites
www.energystar.gov National ENERGY STAR program
www.ncenergystar.org North Carolina Energy Efficiency Alliance based at ASU*
www.epa.gov/greenbuilding U.S. Environmental Protection Agency
www.doe.gov U.S. Dept of Energy
www.usgbc.org U.S. Green Building Council (LEED)
www.resnet.us Residential Energy Services Network (certifies HERS raters)
www.nahbgreen.org NAHB Resource Center: National Green Building Stds & Certifications
www.thegbi.org Green Building Initiative: Green Globe standards
www.greenmadesimple.tv Videos, incentive programs, and energy saving tips
www.advancedenergy.com Advanced Energy - international corporation
www.dsireusa.org Database of State incentives for renewable energy & energy efficiency
www.ncsc.ncsu.edu NC Solar Center at NCSU
www.irecusa.org Interstate Renewable Energy Council
* This organization was formed approximately 2 years ago with a federal grant that has now
expired; whether the organization will continue to exist is unknown, but there is a wealth of
information, training videos and other resources on this website.
-16-
Green Fields in Some MLS Systems
-17-
Statistics for the AIA NC Center for Architecture &
Design, Raleigh, NC See www.cfadnc.org for info & photos
2. Down Spout- Every drop of rain that falls on the building’s roof is collected by a gutter
system that includes a 12-inch-diameter steel pipe cut in half and attached along the entire roof.
The gutter collects the water and directs it to the downspout, which spills into collection pool,
then dumps into the bio-retention cell.
3. Wood Siding- The use of wood for this project became a major element in the final design.
Wood siding helps cut down on solar gain, insulates the building, and is relatively low
maintenance. The cypress is local to North Carolina; reclaimed from the Great Dismal Swamp
in Gates County as a result of being felled by hurricanes; milled locally; sent to Greensboro for
finishing; and finally delivered to the building for installation.
4. Rock Wall- The stone wall is a major design element in this project. The stones used are
local to North Carolina and provide an inside-outside connection for the building and landscape.
The wall running north/south creates a division between the parking garden and the planted
garden, while the east/west wall serves to retain the earth on the southern portion of the site,
which allows the building to have a ground level connection to the street at the corner of Peace
and Wilmington Streets.
5. Bio Retention Cell- The bio-retention garden is a key water management system for the
building and site. Planted with magnolia trees and ground cover, it collects water run-off from
the roof of the building and the parking garden and filters it through layers of soil, gravel, and
sand. Water not fully absorbed into the cell to support the plant life is released into the city’s
storm water system in a much cleaner state.
6. Geothermal Wells- This building is completely heated and cooled by the earth through a
geothermal system. Geothermal systems take advantage of the earth’s constant temperature
with a series of pipes that move water from underground to the building. The water transfers the
warmth or chill from the ground to a series of 10 heat pumps that condition the air in the
building. There is a system of 20 wells, each dug to 350 feet beneath the parking lot. By heating
and cooling the building this way, there is an approximate 64% reduction in energy usage.
7. Porous Paver Parker- Rather than paving with asphalt, the parking garden is comprised of
porous pavers that are installed over 3 feet of gravel and engineered fill. This system slows the
flow of water and allows it to percolate into the ground acting as a filter before it is drained into
the city’s storm water system.
-18-
8. Ventilation- Every floor has been designed with a passive system for free flowing air. Doors
and windows have been strategically placed across from each other to create cross-ventilation.
On days with good weather, heating and cooling systems are not needed at all.
10. Location- Located on the north side of downtown Raleigh, this site required the installation
of 34 parking spaces. To accommodate this mandate, the building was positioned on the
northern-most edge on the lot, leaving ample room for parking as well as a beautiful landscape
on the southern side. The building form is also long and thin, allowing for cross ventilation and
access to light on two to three sides in all spaces. The building has two distinct sides. One side
is park-like and looks toward the Government Complex and Capitol building. This is the front
door of AIA North Carolina. The side that faces Peace Street is much more urban with zinc
siding and individual windows. This is a contribution to Raleigh’s growing urban environment,
which is developing around the Center.
Water efficiency: The Duke Energy Center saves approximately 30 million gallons of water per
year through a combination of rainwater collection, groundwater purification and a 46 percent
reduction of domestic water used in bathrooms.
Energy efficiency: The Duke Energy Center is 22 percent more energy efficient than a
traditionally built tower of comparable size, saving approximately 5 million kilowatt hours per
year, equivalent to the annual energy use of about 450 homes or more than 3,500 metric tons
of greenhouse gas emissions each year, through the use of daylight harvesting blinds that
direct light into the building, lighting controls that respond to the amount of daylight, high
performance glazing on the exterior walls, and highly efficient HVAC systems and controls, all
of which reduce demands on the Duke Energy Center’s lighting and cooling systems.
Other sustainable features: A Green roof is planted with native and adaptive plants, which
reduces the “heat island” effect, reduces heating and cooling loads on the building, mitigates
stormwater runoff, and provides an enjoyable outdoor space for tenants. Also, tenants and
visitors are encouraged to use alternate transportation to get to the Duke Energy Center. The
building provides secure bicycle racks, as well as showers and changing rooms for tenants who
bike to work. It also provides preferred parking for low-emission vehicles, and easy access to
the Charlotte Area Transit System bus and lightrail routes.
During construction of the building, Wachovia/Wells Fargo also took into consideration the
impact of construction activities on both the building site itself and the surrounding city and
region. As a result,
- 75,000 cubic yards of soil were remediated to cleanse and revitalize the land on this
brownfield site.
- 93 percent, or 16, 500 tons, of the construction waste was diverted from landfills.
- 350,000 cubic yards of rock from the site were excavated, crushed, and reused for the
construction of 4 miles of new highway.
- More than 34 percent of the materials used in construction were harvested or extracted and
manufactured regionally, within a 500-mile radius of Charlotte, N.C.
-20-
- Approximately 24 percent of the materials used in construction contain recycled content.
Approximately 50 percent of the wood used in construction is Forest Stewardship Council (FSC)
certified, promoting and supporting sustainably managed forests.
- Materials with low VOC (Volatile Organic Compound) content are used throughout the building
to create a healthier interior environment.
- Recycling areas are an integral part of the building infrastructure, facilitating the collection of
paper, cardboard, metal, plastic and glass.
-21-