Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

i CHROMA II

Up coming
Parameter BELGIUM PORTABLE IMMUNE ASSAY ANALYZER

ACCURATE AND RELIABLE


CE
AMH
HBsAg
Anti-HBs
Anti-HCV
HIV Ag/Ab
Influenza/RSV CERTIFICATIONS
NORO
ROTA
Rota/Adeno
Strep A
Zika IgG/IgM
iFOB/Calp. Combo
H. pylori SA
ABOUT US
Quicklab Services is a small scale and influential manufacturer and trader of
medical equipment in India. The company is renowned as the prominent Medical
Equipment Manufacturer, Exporter, Importer, and Supplier in India. Our
comprehensive array of Medical Equipment encompasses Fully Automatic
Hematology Analyzer, Semi Automatic Biochemistry Analyzer, Fully Automatic
Biochemistry Analyzer, Electrolyte Analyzer, HbA1c Analyzer, Elisa Reader, Elisa
Washer, Coagulation Analyzer etc. We are focused upon various segments of
diagnostic industry and offer world class products across these diagnostic tools.

MISSION
At Quicklab Services Customers come first. By extension, providing quality
healthcare in our fields of expertise to Indian people through supply and support of
appropriate products and spread of healthcare related awareness is our primary goal.
Our customers are our partners. We guide our customers through a highly ethical and VISION
transparent product evaluation process to ensure that specific needs are fully
To lead the path towards a healthier world, we
addressed through an informed choice of the proper products from our wide range.
will strive to become most admired company by
Thereafter, thorough training ensures the optimization of all product benefits for
doctors, diagnostic labs, employees, international
increased productivity in the workplace. Our Professionally trained field support is freely
clients and all channel partners.
available to ensure maximum uptimes for all our customers.

MARKETED AND SERVICE PROVIDER

Plot No 31 B kauvery Street, Ram Nagar South,


Madiapakkam, Chennai - 600091
74490 92777, 74490 93777, 74490 95777 www.quicklab.in
Email : info@quicklab.in, info@quicklab.in
Web : www.quicklab.in
HOW DOES IT WORK? TEST PROCEDURE TEST ITEMS
TEST TEST WORKING
ichroma™ II is an automatic or semiautomatic in-vitro
diagnostic device that measures the concentration of NAME TIME RANGES
analytes, contained in blood, urine, or other samples, in Cardiac
quantitative or semi-quantitative ways. Compared to the first- 0.1-50.0 ng/mL
generation device, ichroma™, ichroma™ II has an improved TN - I 12 MIN.
user interface and display and an advanced optical system, TN-I PLUS 12 MIN. 0.01-15.00 ng/mL
which provide the user with disease test options in wide CK-MB 12 MIN. 3-100 ng/mL
range. 0.01-15.00 ng/mL
D-DIMER 12 MIN.
NT-PROBNP 12 MIN. 10-30,000 pg/mL
MYOGLOBIN 12 MIN. 5-500 ng/mL
HSCRP 3 MIN. 0.1-10.0 mg/L
CARDIAC TRIPLE 12 MIN. Tn-I: 0.01-15.00 ng/mL
CK-MB: 3-100 ng/mL
Cancer Myoglobin: 5-500 ng/mL

PSA 15 MIN. 0.1-100.0 ng/mL


AFP 15 MIN. 5-350 ng/mL
CEA 12 MIN. 1-500 ng/mL
IFOB 10 MIN. 25-1,000 ng/mL
ADVANTAGE Diabetes
Interface: Expansion of user interface through adoption of HBA1C 12 MIN. (NGSP) 4-15 %
Android OS MICROALBUMIN 12 MIN. 2-300 mg/L
Display: 7 "touch panel provides operational stability and CYSTATIN C 10 MIN. 0.1-7.5 mg/L
quick response Hormone
Portability: Battery for unexpected power failure or poor 12 MIN. 0.1-100.0 μ IU/mL
TSH
power environment for a certain period
TSH PLUS 12 MIN. 0.1-50.0 μ IU/mL
Data storage and update: Available to store and search
T3 16 MIN. 0.77-7.70 nmol/L
large amount of test results
Data back-up and OS update using SD card
T4 16 MIN. 10.23-300 nmol/L
Optical technology: Improved fluorescence optical module FSH 15 MIN. 1-100 mIU/mL
for high sensitive diagnosis LH 15 MIN. 1-100 mIU/mL
Measurement modes: Single, multi-mode, QC test and PRL 10 MIN. 1-100 ng/mL
review (save results) mode HCG 15 MIN. 2-3,000 mIU/mL
Stability: Reduced risk of test error based on the equation Β ETA-HCG 15 MIN. 5-50,000 mIU/mL
saving function TESTOSTERONE 15 MIN. 1-10 ng/mL
Connectivity: Built-in printer, improved wired / wireless PROGESTERONE 15 MIN. 1.4-40 ng/mL
connectivity, LIS / HIS communication CORTISOL 10 MIN. 80-800 nmol/L
USB hub chip supporting 4 USB ports
Infection
Convenience: Keyboard adaptable for non-touchpad user
PCT 12 MIN. 0.1-100.0 ng/mL
Improved convenience to input sample ID and tester ID
ASO 12 MIN. 25-800 IU/mL
I CHAMBER INCUBATOR The i-chamber is an CRP
SPECIFICATIONS auxiliary device for the
Dengue NS1 Ag
3 MIN.
12 MIN.
2.5-300.0 mg/L
qualitative
Dimensions 276 mm (L)x220 mm(W)x91 mm (H) ichroma(ichroma™,
ichroma™ II) systems and
Dengue IgG/IgM 12 MIN. qualitative
Power supply DC 12V/5A, AC/DC Adaptor, (AA battery)
provides an environment Influenza A+B 10 MIN. qualitative
DC 1.5V X 4ea. Input 100-240V ~ 50/60Hz, 1.8A. Output
DC 12V/5A set to the correct Total IGE 12 MIN. qualitative
temperature to the
Data output 7” touch color LCD
ichroma cartridge when Rheumatoid Arthritis
Motor Stepper Linear Actuator (5V, 0.34A) RF IGM 5 MIN. 8-200 IU/mL
heating is required
Communication ports USB 4 ports, LAN port ANTI-CCP 12 MIN. 5-200 U/mL
between tests. You can
Operation temperature/ humidity range15 ~ 35°C
Storage temperature/humidity range Temperature -20 ~
improve the reliability of Others
your test results by 10-1,000 ng/mL
50°C, Humidity Max. 70% FERRITIN 10 MIN.
keeping the temperature 8-70 ng/mL
Data output LCD and built-in printer constant, one of the
VITAMIN D 28 MIN.
Test result storage Patient test results (1,000) / System Calprotectin 10 MIN. 10-1,000 mg/kg
environmental factors
check results (500) that can cause unexpected Pack Size : 25 Test/Pack, PCT 10 Test / Pack
Standard material (control) test results (1,000) errors in your test results. Shelf life : 20 months at 2-8℃(Buffer)
www.quicklab.in : 20 months at 4-30℃(Cartridge)

You might also like