Preset Load Cell Tension Measuring Roll: 15.03.2016 Hrahn
Preset Load Cell Tension Measuring Roll: 15.03.2016 Hrahn
15.03.2016 HRahn
To Preset Service Mode must be activated. Therefore the Key switch in Main Desk +CD
must be turned to “ON” Position.
Emergency Stop must not be active and all Drives must be switched Off
Seite 1 von 5
JAGENBERG-GRUPPE
When Service Mode is active it is Shown on Main Screen in “Operation Mode” Field
To Reset to zero the Tension Roller must be without any load (No Film).
To Reset hold the Softbutton “Reset” for 3s.
When Reset is done the actual Tension will show 0N
Seite 2 von 5
JAGENBERG-GRUPPE
Now Preset can be done. Therefore hold the Softbutton “Preset” for 3s.
When Preset is done the actual Tension will show the Preset force, e.g. 1000N (100Kg).
To see whether the ratio Drive Side to Non Drive Side Load Cell is even the feedback of
both Load cells can be checked on Main Screen
Seite 3 von 5
JAGENBERG-GRUPPE