TEST CERTIFICATE

Date : 04-09-2020 , 03:00 PM

MEFT
Peenya . Bangalore
sample Identification : HEAT/BATCH A1393 /4467 HTBATCH10 H 110
Part description : SS 316
Part Number : H A1393 B 4467 HTB 10 H 110

Sample Identification : HEAT/BATCH A1393 /4467 HTBATCH10 H 110

Machine : Universal Testing Machine 400 kN

Input Data File Name : SS316 Record No. : 1


Sample Type : Round Solid Bar Area : 122.768 mm ²
Diameter : 12.5 mm Final Dia : 5.9 mm
Ext. Gauge Length: 50 mm Speciman Gauge Length: 50 mm
Final Gauge Length: 75.6 mm

Results of Extension Test


Maximum Force (Fm) : 81.880 kN Reduction in Area (Z) : 77.722 %
Disp. at Fm : 29.000 mm Youngs Modulus (E) : 304232.700 MPa
Max. Extension : 1.790 mm Yield Load : 65.140 kN
Tensile strength (Rm) : 666.950 MPa Yield Stress : 530.595 MPa
Total Elongation at Fm (Agt): More than 3.58 % 0 .2 % Proof Load : 52.140 kN
Elongation : 51.200 % Proof Stress (Rp0 .2) : 424.7040 MPa
YS/UTS Ratio : 0.796
* Note : Yield Calculated From Graph
Graph : Load Vs Extension
90.000

81.000

72.000

63.000

54.000

45.000

Load 36.000
kN
27.000

18.000

9.000

Y0=0.000 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00
X0=0.000 -----> Extension mm

TESTED BY INSPECTED BY WITNESSED BY

ISRAVEL RAJ RAGAVENDRA