CI/SfB

Yu4 (K2)
CAW G12
Uniclass JM61:L68116

• Steelwork should be blast cleaned


Product Information

SC902
in dry atmospheric conditions using
abrasive of suitable type and size,
Description
free from fines, moisture and oil.
SC902 is a low VOC, one coat, high build
Continue blasting until finish complies
system, based on patented technology.
with Swedish Standard SIS 05 59 00, Intumescent
preparation grade SA 2.5 or ISO 8501-1.
Usage / Purpose
• Coat blasted steel within 2 weeks. Steel Coating
It provides a fast cure effective structural
fire performance, for steelwork, up to a
All surfaces to be coated should be Fast Track, On-Site
clean, dry and free from loose friable
120 minute fire rating.
materials and any other contaminants
SC902 is designed to provide upto 120
likely to impair adhesion.
minutes fire resistance to ‘I’ section
• Nullifire recommends and have tested
beams, columns, hollow columns,
a number of primers depending on
concrete filled hollow columns and
the application. Refer to the Approved
cellular beams. As a fast-track coating,
Primer list from Nullifire Technical
all 120 minute loadings are possible
Services.
to apply in a single coat and weather
• The system is not suitable for use over
resistant in one hour.
single pack primers and compatibility
with 2 pack primers should be checked
Finish
with Nullifire Technical Services.
Can be applied to a smooth matt finish.
• For use over galvanised surfaces
A compatible top seal can be applied if a
or other substrates please contact
decorative finish is required.
Nullifire Technical Services.

Colour
Application Conditions
Part A: White
• Ensure adequate through ventilation
Part B: Translucent Black
during application
Mixed: Off-white
• Application temperature range -5°C to
Cured: Off-white Key Benefits Summary
+35°C, relative humidity <95% and a
steel surface temperature at least 3°C
Packaging
above the dew point. • Fast cure, even below 0°C,
Part A 22.3 kg pail touch dry in 1 hour
Part B 2.7 kg tin
Application Equipment
Graco Mark V or equivalent
• Early weather resistance,
Environmental Considerations shower proof within 1 hour
Low VOC and no solvent entrapment or
Mixing • Self-priming system tolerant
prolonged solvent odour. of light rusting to steel, up to 2
• Always mechanically mix product in
full pack volumes. weeks post blasting
Availability
• Ensure the two components are • High build potential with
Only available to Nullifire Specialist
thoroughly combined until a uniform all ratings possible in one
Contractors direct from Nullifire (see
colour is obtained. application
back of leaflet for address and telephone
details).
Application • Fire rating up to 120 minutes
• Keep all product containers closed tested to BS476 and EN13381:
Usage Guidelines when not in use. Parts 6 & 8

Protective Equipment
• Part B is moisture sensitive and should • Designed for on-site use
remain tightly closed before use.
Use in well ventilated conditions and
• The product is self-priming onto
ensure all recommended protective
correctly prepared steelwork.
equipment is worn during handling
Damaged primer does not need to be ETA 14/0079 APPROVAL N° CF5144
& use of this product. For full
repaired in C1 or C2 environments.
recommendation, refer to safety data
• The product should be spray applied
sheet.
at close proximity, approximately
600 mm from the surface, to avoid
Surface Preparation & Priming
dusting and promote good surface
• No primer required for C1 or C2 coalescence.
environments.
• Use of a wet film gauge is essential.
SC902
Intumescent Steel Coating

• As a fast-track coating, it is possible


to apply single coat thicknesses
Technical Data
significantly greater than traditional
coatings, upto 10 mm without defect. Property Result
All 120 minute loadings are possible A low VOC, high build formulation based on
to apply in a single coat; however, we Composition
advanced hybrid technology
recomend that the applicator select Performance
a target WFT in line with substrate
geometry, access and level of finsh ‘Prohesion’ Cyclic Corrosion test to ASTM G85:2009 Annex A5
required for the project. At 1000 hours Maximum extent of undercut corrosion 6.00 mm from scribe mark
Note: The above test was carried out on a primer-less steel substrate
Note: If the user needs to stop spraying
Certifire CF5144, BS476 Part 20/21, EN13381:
for longer than 15 minutes flushing will
Part 6 & 8 and Cellular Beams YB5
be necessary.
GOST Russian approval
Certification
Australian standards AS4100 and AS1530
Site Work
Japanese standard JIS A1304
• Galvanised bolts, once degreased, can (for other certification requirements, contact Nullifire)
be coated with no further preparation.
• Damaged coatings can be trimmed C1, C2, C3, C4 and C5 environments
to a feathered edge and the material Building Classification For full details, please consult Nullifire Specification
Guidelines.
troweled in one application.
• The applied product once cured can Properties (Typical Values)
be easily finished to a high level, Part A: 1.55 ±0.02
by sanding or tooling with either Specific Gravity Part B: 0.99 ±0.01
electrical or hand tools. Mixed: 1.46 ±0.02
• Repairs can be carried out using an Volume Solids 85% ±3%
SC900 Repair Kit.
VOC 137 g/litre
Cleaning By Weight 100:12
Mix Ratio
Flush spray equipment with FC150 or By Volume 5.6:1
an equivalent xylene based solvent, Gel Time (Liquid to Gel) 90 - 120 minutes
do not use solvents which contain
Pot-life or Sprayable Life 60 minutes
water, as these can result in premature
curing of the product in the spray line. 1,750 g/m² based on an applied 1.00 mm dry
Theoretical Coverage
Contact Technical Support if unsure of film thickness
compatibility of cleaning agents. Store in secure, dry warehouse conditions
Storage
between +0°C and +35°C
Top Seal Requirements
12 months when stored as recommended in
Once DFT’s have been achieved as Shelf Life (at +20°C)
original unopened container
specified, a Nullifire top seal can be
applied. Ensure the SC902 is completely
Specification Guarantee / Warranty
dry before applying top seal. For
A Tremco CPG UK Limited Tremco CPG UK Limited products are
approved top seals, please consult
Representative will provide a manufactured to rigid standards of
Nullifire’s Approved Topcoat List.
specification for each project. quality. Any product which has been
Tremco CPG UK Limited accepts no applied (a) in accordance with Tremco
Maintenance & Repair
responsibility for defects arising from CPG UK Limited written instructions and
Damaged areas should be abraded
failure to follow the specification. (b) in any application recommended by
back to a sound surface. The surface
Tremco CPG UK Limited, but which is
should then be clean and dry before
Health & Safety Precautions proved to be defective, will be replaced
re-applying. The SC900 repair kit should
Safety data sheet must be read and free of charge.
be used (sold separately) for repairing
understood before use. No liability can be accepted for the
scratches and chips. Once repaired
Flammable - keep away from open information provided in this leaflet
top seal should be re-applied. Refer to
flames and other ignition sources. although it is published in good faith
Nullifire System SC900 Maintenance
and believed to be correct.
Instructions.
Technical Service Tremco CPG UK Limited reserves the
Tremco CPG UK Limited has a team right to alter product specifications
of experienced Technical Sales without prior notice, in line with
Representatives who provide assistance Company policy of continuous
in the selection and specification of development and improvement.
products. For more detailed information,
service and advice, please call Customer
Services on 01322 551010.
SC902
Intumescent Steel Coating

Topseal Requirements
Once DFT’s have been achieved as specified, TS134 Top Seals can be applied. Ensure the SC902 is completely cured before
applying top seal.
ETAG018: Part 2 Condition Description of Environment Example Approved Topseals
Exposure to rain
Fully external steelwork
X: Exposed Exposure to UV Consult ETA or Nullifire
Exposed perimeter steel
(also qualifies for Y & Z) Uncontrolled humidity Technical Department
Open construction site
Uncontrolled temperature
Uncontrolled humidity
Car park
Y: Semi-exposed Uncontrolled temperature Not required
Undercrofts
(also qualifies for Z) No exposure to rain (consider other factors)
Areas under a canopy
Limited exposure to UV
Z1: Humid internal Humidity over 85% RH Plant rooms, Basements, Not required
(also qualifies for Z2) Temperature above 0°C Warehouse and production (consider other factors)
Humidity below 85% RH Office, Hospitals, Schools, Not required
Z2: Dry internal
Temperature above 0°C Airports Decorative only

Tremco CPG UK Limited Customer Service Unit:


2020-06

Coupland Rd, Hindley Green +44 (0)1322 551010


Wigan WN2 4HT UK Technical Hub:
www.cpg-europe.com Tel: +44 (0)1942 251400 +44 (0)20 3917 1776