1 2 3 4 5 6 7 8 9 10 11 12

KEY PLAN
PLANT NORTH/ PLANT NORTH /
TRUE NORTH PREVAILING WIND
TRUE NORTH DIRECTION
PREVAILING WIND .70
° (SSW)

E 578000.000
DIRECTION MECCA
78
(SSW) N 2121000.000
0 °
7 8.7
MECCA

2120152465.03
578162500.00N
E
N 2120500.000

A A
A
MATCH LINE FOR CONT. ON DWG. No. 9686-8230-01-820-5002 N 2120007.750
CL 6M WIDE ROAD FRL EL +91.650

E 578258.000

E 578298.300
CRANE STANDING AREA

E 578237.100
CRANE STANDING AREA
713-HD-121

E 580500.000
E 578264.050
N 2119000.000
PEDESTRIAN PEDESTRIAN
MH CROSSING 713-HD-122 (NOTE-6) MH MH CROSSING

E 578225.220

E 578230.720
E 578219.220
THIS DRAWING

E 578287.300
E 578281.300

E 578291.900

E 578297.900
GENERAL NOTES

E 578236.720
713-T-405B 1. ALL COORDINATES ARE IN METRES AND ALL DIMENSIONS ARE
N 2119988.150 CL

RENTAL DESALINATION UNIT


N 2119995.200 N 2119995.200 IN MILLIMETRES (U.N.O).
ELECTRICAL CABLE TRENCH (BURIED) 2. ALL ELEVATIONS ARE IN METRES AND RELATIVE TO MEAN
713-T-XXXX 713-T-XXXX N 2119990.150 SEA LEVEL (MSL) EL +0.000m.

PAVING EXTENT
EL +91.600 713-T-405C 713-T-403B

E 578210.000
FUTURE PHASE FUTURE PHASE EL +91.600 3. MEAN SEA LEVEL EQUALS CHART DATUM +1.53M.

E 578204.000
N 2119986.150

E 578222.220
(FUTURE PHASE)

E 578210.810
(FUTURE PHASE)
HPP N 2119989.900

(FUTURE PHASE)
HPP

CL 713-P-405A

CL 713-P-405B
4. PLANT COORDINATES REFER TO HORIZONTAL DATUM, WGS-84,

E 578260.200

E 578284.300

E 578294.900
E 578264.640

E 578273.700
E 578233.720
CL 713-T-403C UTM PROJECTION, ZONE 40N.

CL 713-P-403A
713-P-402A

CL 713-P-403B

CL 713-P-403C
713-P-402B

CL 713-P-405C
713-P-402C
B EL +91.500 N 2119988.150 5. FUTURE PHASE EQUIPMENTS LOCATIONS ARE PRELIMINARY. B
FUTURE ELECTRICAL CABLE TRENCH PAVING EXTENT
N 2119983.050 FGL 6. FOR LOCATION OF ALL CSW MANHOLE REFER DRAWING
(BURIED)
RAMP DYKE WALL PAVING EXTENT DYKE WALL B 9686-8310-45-000-4531 STORM WATER DRAINAGE LAYOUT
N 2119983.050 VC AREA-B

E 578304.900
R2760 RAMP

E 578301.900
713-P-401A
NOTE-7

713-P-401B
SAFETY ZONE RADIUS R2760 R2760 7. FOR LOCATION OF ALL CB,VC,PCSWMH REFER DRAWING
PCSWMH N 2119981.140 SAFETY ZONE RADIUS 9686-8310-45-000-4537 OILY WATER DRAINAGE LAYOUT
NOTE-7
AREA-B.

DESALINATION UNIT
RAMP 8. FOR FIRE AND EXPLOSION HAZARD ANALYSIS (FEHA) REPORT

START SYSTEM
NOTE-7 CB CB PAVING EXTENT REFER DOC NO. 9686-8150-ST-000-2002

START SYSTEM
CB CB 9. FOR REFERENCE DRAWINGS REFER SHEET 01 & 02 OF THIS

HYDRAULIC
N 2119976.550

CL
CL
N 2119974.385 CURB WALL CURB WALL N 2119974.385 NOTE-7 DRAWING.
CB

HYDRAULIC
CL NOZZLE CL NOZZLE N 2119973.060

(TYP)

RENTAL
CLOF NOZZLE LEGEND

(TYP)
EL +91.600
CL 6M WIDE ROAD

SLEEPERS SLEEPERS PAVING EXTENT


(TYP) EL +91.600 (TYP) HPP N 2119970.250 FGL - FINISHED GRADE LEVEL
HPP N 2119968.950
FRL - FINISHED ROAD LEVEL

PAVING EXTENT
PAVING EXTENT PAVING EXTENT TOS - TOP OF STEEL

E 578306.725

E 578322.900
N 2119966.800 N 2119966.800

PAVING EXTENT
E 578300.900
E 578267.080
TOGr - TOP OF GRATING

PAVING EXTENT

PAVING EXTENT
TOC - TOP OF CONCRETE

CSW CHANNEL
E 578240.000

E 578258.050
C TOP - TOP OF PLATE C
HPP - HIGH PAVING POINT
TOS EL. +92.200 TOG EL. +92.200 CO - CLEAN OUT
(TYP) (TYP) TOS EL. +94.360 TOS EL. +92.200 B CB - CATCH BASIN
INSTRUMENT CABLE TRENCH (BURIED) (TYP) CP - CATHODIC PROTECTION
E 578135.500

CSW - CLEAN SURFACE WATER

MATCH LINE E 578322.900 FOR CONT. ON DWG. No. 9686-8230-01-712-5001


PIPE SUPPORTS

CL 6M WIDE ROAD
TELECOM CABLE TRENCH (BURIED) (TYP) PCSW - POTENTIALLY CONTAMINATED
SURFACE WATER
MH - MAN HOLE
TOP OF BERM EL +92.930 (TYP) VC - VALVE CHAMBER
TOP

TOGr EL. +94.392


- EMBANKMENT
BOTTOM
PIPE SUPPORTS
MATCH LINE FOR CONT. ON DWG. No. 9686-8230-01-820-5002

TOS EL. +94.360 - CONCRETE PAVING


CSW CHANNEL

C - GRADE (OPEN UNPAVED AREAS)

(TYP)
STAIRCASE STAIRCASE
(TYP) VALVE ACCESS (TYP) - ELECTRICAL CABLE TRENCH (BURIED)

E 578231.900

CL E 578280.900
D PLATFORM (TYP) D
TANK EMBANKMENT - INSTRUMENT CABLE TRENCH (BURIED)
UP UP
- TELECOM CABLE TRENCH (BURIED)
- FUTURE

CL
EL +91.500 PACKAGE 1 : EPC PKG 1.1.1 - SUB PHASE 1.1. EPC PACKAGE 1.1.1.
FGL
PACKAGE 2 : EPC PKG 1.1.2 - SUB PHASE 1.1. EPC PACKAGE 1.1.2.
CL N 2119928.000 713-T-401A 713-T-401B
TOGr EL. +96.632 PACKAGE C : EPC PKG 1.1.3 - SUB PHASE 1.1. EPC PACKAGE 1.1.3.
(TYP)

Drawing limit
C

RECTIFER/JUNCTION BOX
RECTIFER/JUNCTION BOX
N 2119921.500

SLEEPER

MH
(TYP)

CP TRANSFORMER
CP TRANSFORMER

E 578251.400

E 578261.400
CRANE REFERENCE DRAWINGS
STANDING AREA
DRAWING NO. TITLE

N 2119912.500 UP UP N 2119912.500 9686-8310-41-000-4505 OVERALL SITE PREPARATION PLAN


E E

6M WIDE ROAD

E 578304.200
E 578208.600

E 578256.400
9686-8310-41-000-4508 OVERALL SITE PREPARATION PLAN INDEX
SPIRAL STAIR SPIRAL STAIR
(TYP) (TYP) 9686-8230-02-000-5001 PLOT PLAN DRAWING INDEX SUB PHASE 1.1

9686-8230-01-000-5002 OVERALL SITE PLAN SUB PHASE 1.1

9686-8230-01-000-5003 OVERALL PLOT PLAN FOR SUB PHASE 1.1.2

CL
MH CSW CHANNEL
9686-8230-02-000-5002 UNIT PLOT PLAN DRAWING INDEX -
SUB PHASE 1.1.2
EL +91.650 6M WIDE ROAD EL +91.650 9686-8310-45-000-4522 GRADING AND PAVING LAYOUT INDEX
CL
FRL N 2119898.500 FRL
TELECOMMUNICATION CABLE ROUTING FOR
9686-8540-80-940-3040
FIREWATER AREA
9686-8320-43-713-4503 TYPICAL SLEEPER FOUNDATION DETAILS -
FIRE WATER AREA
MH CSW CHANNEL A 9686-8310-41-000-4521 ROAD AND FENCE LAYOUT AREA B

9686-8310-45-000-4546 UNDERGROUND SERVICE LAYOUT INDEX


F ELECTRICAL CABLE ROUTING LAYOUT F
FRL EL +91.650 TELECOM CABLE TRENCH (BURIED) 9686-8530-78-920-3505
FIRE WATER AREA
9686-8320-43-713-4504 TYPICAL PIPE SUPPORT FOUNDATION
]

DETAILS-FIRE WATER AREA


9686-8310-46-713-4501 TYPICAL PIPE SUPPORT STRUCTURE
]

ELECTRICAL CABLE TRENCH (BURIED) DETAILS-FIRE WATER AREA


9686-8550-68-713-3001 INSTRUMENT CABLE ROUTING FOR FIRE
WATER AREA (713)
]
]

01 16-07-20 ISSUED FOR CONSTRUCTION SAN KKT HP MJH


FUTURE ELECTRICAL CABLE TRENCH (BURIED)
B2 17-02-20 ISSUED FOR APPROVAL SAN KKT HP MJH
]

B1 27-10-19 ISSUED FOR APPROVAL SAN KKT MU MJH


]

A1 27-08-19 ISSUED FOR REVIEW/COMMENTS SAN KKT MU SRA


FUTURE ELECTRICAL CABLE TRENCH (BURIED) REV DATE DESCRIPTION BY CH'D APP APP
]

G G
REVISIONS
]

CLIENT:
FRL EL +93.950

TELECOM CABLE TRENCH (BURIED) OMAN TANK TERMINAL COMPANY (OTTCO)

CRASH BARRIER
EPC CONTRACTOR:
] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ]
中国石油管道局工程有限公司
CHINA PETROLEUM PIPELINE ENGINEERING CO., LTD.
6M WIDE ROAD FRL EL +93.950
CL

PLOT DATE / TIME : 7/16/2020 5:24 PM


PROJECT TITLE:
MATCH LINE FOR CONT. ON DWG. No. 9686-8230-01-620-5001 N 2119844.500 MATCH LINE FOR CONT. ON DWG. No. 9686-8230-01-720-5001 N 2119844.500 RAS MARKAZ CRUDE OIL PARK PROJECT (PHASE 1)
E 578235.500

EQUIPMENT NO. DESCRIPTION SCOPE DRAWING TITLE:

H
713-P-405 A FIREWATER PUMPS FULL SURFACE FIRE (ELECTRIC DRIVEN) (EPC PKG 1.1.2.) UNIT PLOT PLAN
713-P-405 B/C FIREWATER PUMPS FULL SURFACE FIRE (DIESEL DRIVEN) (EPC PKG 1.1.2.)
713-P-403 A SMALL FIREWATER PUMPS (ELECTRIC DRIVEN) (EPC PKG 1.1.2.)
FOR
713-P-403 B/C SMALL FIREWATER PUMPS (DIESEL DRIVEN) (EPC PKG 1.1.2.) FIREWATER AREA
713-P-401A/B FIREWATER JOCKEY PUMPS (EPC PKG 1.1.2.)
THIS DRAWING IS GENERALLY REVISED, HENCE REVISION
713-T-401A/B FIREWATER TANKS (EPC PKG 1.1.2.) CLOUD AND HOLD IS NOT SHOWN.
713-T-405B/C DIESAL DAY TANKS (EPC PKG 1.1.2.)
DRAWING No: PROJECT

A0 (1189x841)
713-T-403B/C DIESAL DAY TANKS (EPC PKG 1.1.2.) 0 2.5m 5.0m 10m 15m 20m 25m
No. 9686
713-P-402A/B/C FIREWATER PUMPS (FUTURE PHASE) 9686-8230-01-713-5001
713-T-XXXX DIESAL DAY TANKS (FUTURE PHASE) SCALE DOC. CLASS/CAT. : SHEET REV.
SCALE 1:250 1 : 250 1 01 OF 02 01
This document contains information which is subject to obligations of non-disclosure and is to be returned to Oman Tank Terminal Company L.L.C. upon request. The contents may not be copied, disclosed or made available to any third party or used other than
for the intended purpose for which it has been provided unless Oman Tank Terminal Company L.L.C. provides written consent for such copy, disclosure, availability and/or use. 4 5 6 7 8 9 10 11 CAD FILE NAME: 9686-8230-0-1731-500_
1D0.W
1G 12
1 2 3 4 5 6 7 8 9 10 11 12

GENERAL NOTES
1. FOR OTHER NOTES, LEGENDS, HOLDS AND REFERENCE
DRAWINGS SEE SHEET 01 & 02 OF THIS DRAWING.

REFERENCE DRAWINGS

N 2119912.500
CL 713-T-401B
DRAWING NO. TITLE
A 9686-8310-41-000-4510 SITE PREPARATION PLAN - AREA B A

9686-8530-74-713-3501 LIGHTING & SMALL POWER LAYOUT


FIRE WATER AREA
LAYOUT DRAWING FOR TANKS
9686-8360-85-713-2504 INTERNAL CP SYSTEM-FIRE WATER
TANKS (713-T-401A/B)
LAYOUT DRAWING FOR TANKS
9686-8360-85-713-2503 EXTERNAL BOTTOM CP SYSTEM-FIRE
WATER TANKS(713-T-401A/B)
TYPICAL PIPE SUPPORTS STRUCTURE
9686-8320-43-000-4520
DETAIL ON TANK SHELL
CONCRETE GENERAL ARRANGEMENT
9686-8320-43-713-4508
FOR FIRE WATER AREA
STEELWORKS GENERAL ARRANGEMENT
9686-8320-46-713-4504 AND DETAILSFOR ACCESS PLATFORM-2
FIREWATER AREA
FIREWATER TANKS 713-T-401A/B TANK

CL 6M WIDE ACCESS ROAD

CL 6M WIDE ACCESS ROAD


B 9686-8430-14-713-4001-001 GENERAL ARRANGEMENT & BASIC DATA B

N 2119974.385
CL 713-P-403B
DRAWING
FIREWATER TANKS 713-T-401A
TOC EL. +92.930 9686-8430-14-713-4001-002 GENERAL ARRANGEMENT &

N 2120007.750

N 2119898.500
TOG EL. +92.400 ORIENTATION DRAWING
TOC EL. +92.005

CSW CHANNEL
FIREWATER TANKS 713-T-401B
713-T-403B 9686-8430-14-713-4001-003 GENERAL ARRANGEMENT &
TOS EL.+92.330
300 ORIENTATION DRAWING
(TYP) TOG EL. +93.280
ELECTRICAL DUCT BANK

900
TOS EL. +92.200 9686-6120-05-PO0035-0002 713-T-405 B/C FUEL TANK DRAWING
FGL EL. +91.500

1435
SMALL FIRE WATER PUMPS (ELECTRIC
900 9686-6120-05-PO0035-0008 MOTOR DRIVEN) 713-P-403 A GENERAL
800 INSTRUMENT CABLE TRENCH
ARRANGEMENT DRAWING WITH DETAILS

1000

1130
775
12330 2600 2020 5400 3450 5210 3000 2755 1385 2610 4955 5190 26495 22940 5665 SMALL FIRE WATER PUMPS (DIESEL

900
9686-6120-05-PO0035-0005 ENGINE DRIVEN) 713-P-403 B/C GENERAL
ARRANGEMENT DRAWING WITH DETAILS

9686-6120-05-PO0035-0006 713-T-403 B/C FUEL TANK DRAWING &


SIZING CALCULATIONS
C C
JOCKEY PUMP GENERAL ARRANGEMENT
SECTION A-A 9686-6120-05-PO0035-0009
DRAWING 713-P-401 A/B
GENERAL ARRANGEMENT DRAWING WITH
9686-6120-05-PO0035-0001 DETAILS FOR FIREWATER PUMPS FULL
SURFACE (DIESEL ENGINE DRIVEN)
713-P-405 B/C
GENERAL ARRANGEMENT DRAWING WITH
9686-6120-05-PO0035-0004 DETAILS FOR FULL SURFACE FIRE WATER
PUMP (MOTOR DRIVEN) 713-P-405 A

D D

E E
N 2119973.060
CL 713-P-401B

TANK SHELL

N 2119912.500
CL 713-T-401B
PIPE SUPPORTS
(TYP)
TOG EL. +91.830 TOS EL. +92.155
ELECTRICAL CABLE TRENCH
200 100

FGL EL. +91.500


900
1060

1100 300 1235 2055 345 470 1150 650 200 INSTRUMENT CABLE TRENCH

F F

VALVE ACCESS
SECTION B-B PLATFORM
SCALE 1:50 HANDRAIL
TOS EL. +96.600
LADDER

PIPE SUPPORT TOGr EL. +94.392


TOS EL. +94.360 TOS EL. +94.360 01 16-07-20 ISSUED FOR CONSTRUCTION SAN KKT HP MJH

B2 17-02-20 ISSUED FOR APPROVAL SAN KKT HP MJH


TOC EL. +92.930
B1 27-10-19 ISSUED FOR APPROVAL SAN KKT MU MJH

A1 27-08-19 ISSUED FOR REVIEW/COMMENTS SAN KKT MU SRA


REV DATE DESCRIPTION BY CH'D APP APP
G G
INSTRUMENT CABLE TRENCH REVISIONS
CLIENT:

SECTION C-C OMAN TANK TERMINAL COMPANY (OTTCO)

SCALE 1:100
EPC CONTRACTOR:

中国石油管道局工程有限公司
CHINA PETROLEUM PIPELINE ENGINEERING CO., LTD.

PLOT DATE / TIME : 7/16/2020 5:34 PM


PROJECT TITLE:
RAS MARKAZ CRUDE OIL PARK PROJECT (PHASE 1)
DRAWING TITLE:

H UNIT PLOT PLAN


FOR
0 0.5m 1.0m 2.0m 3.0m 4.0m 5.0m
FIREWATER AREA
SCALE 1:50

0 2.0m 4.0m 8.0m 12m 16m 20m


DRAWING No: PROJECT

A0 (1189x841)
No. 9686
SCALE 1:200
9686-8230-01-713-5001
SCALE DOC. CLASS/CAT. : SHEET REV.
1 : 200 1 02 OF 02 01