10mmØ Reinforcing

10mmØ Reinforcing 150mm


Steel Horizontal Bars
Vertical Bars Spaced @ Spaced @ every 3 Layers
800mm O.C. of C.H.B
350mm

150mm

Stiffener Column

150mm
4-12mmØ Reinforcing 10mmØ Reinforcing
Steel Vertical Bars Vertical Bars Spaced @
Stiffener Column 800mm O.C.
10mmØ Reinforcing (See location at plan)
Steel Ties Spaced
@ 200mm O.C.

10mmØ Reinforcing 10mmØ Reinforcing 10mmØ Reinforcing


Steel Horizontal Bars Vertical Bars Spaced @
Steel Horizontal Bars
Spaced @ every 3 Layers 800mm O.C. Spaced @ every 3 Layers
of C.H.B of C.H.B
Natural Grade Line
1000

3-10mmØ Continuous
250

Reinforcing Bars spaced equally


10mmØ temperature bars
Spaced @ 150mm O.C.
10mmØ Temperature bars
Gravel Bed Spaced @ 150mm O.C. 10mmØ Continuous
Gravel Bed
Reinforcing Bars.

WALL FOOTING DETAIL