AS/NZS 1170.

2/Amdt 1/2005-04-04

STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND

Amendment No. 1
to
AS/NZS 1170.2:2002
Structural design actions
Part 2: Wind actions

CORRECTION
The 2002 edition of AS/NZS 1170.2 is amended as follows; the amendment(s) should be inserted in the
appropriate place(s).
SUMMARY: This Amendment applies to the Preface, Clauses 1.1, 1.2, 1.4, 2.5.1, 3.2, 4.3.2, 4.3.3, 5.4.1,
6.2.2, 6.4, Figures 3.1, 4.4, 5.1 (in part), 5.2, 5.3, Tables 3.1, 4.2(A), 5.2(B), 5.6, Equations 6.2(2), 6.2(5),
6.3(6), 6.4(1) and Appendices B, C, D, E, F and G.
Published on 4 April 2005.
Approved for publication in New Zealand on behalf of the Standards Council of New Zealand on
11 March 2005.

AMDT Page 3 PREFACE


No. 1
APR Add the following at the end of the Preface:
2005
Essentially, AS/NZS 1170.2 is independent of the design requirement specified—thus
becoming a purely technical document. It may be used to calculate wind speeds, wind
pressures and wind forces given any annual probability of exceedance. The annual
probability of exceedance (P) defines the wind event (in which pressures and forces occur).
Thus a major wind storm with an annual probability of exceedance in the range of 1/200 to
1/2500 is used for ultimate limit states, while a much more frequent wind event (say of
1/25) might be used for serviceability limit states.
In AS/NZS 1170.2, Table 3.1 gives the regional wind speeds for selected annual
probabilities of exceedance and Section 2 sets out the determination of site wind speeds,
design wind speeds, design wind pressures and wind actions (forces or loads) that are
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007

appropriate for the annual probability specified.


The annual probability of exceedance is not defined in AS/NZS 1170.2, but is set out in
AS/NZS 1170.0 [and by further reference for ultimate limit states in the BCA (Table of
annual probabilities of exceedance) and in the Guide to the BCA (examples of structures for
importance levels)]. AS/NZS 1170.0 gives the annual probability of exceedance for New
Zealand structures and for Australian structures not covered by the BCA. Guidance for
serviceability events and associated limits is given in an informative Appendix of
AS/NZS 1170.0 for loads associated with an appropriate annual probability of exceedance
(P) for serviceability.

AMDT Page 6 Clause 1.1


No. 1
APR Add the following NOTE 3:
2005
3 In this document, the words ‘this Standard’ indicate AS/NZS 1170.2, which is regarded as
Part 2 of the AS/NZS 1170 series of Standards (see Preface).

ISBN 0 7337 6575 0


AMDT Page 6 Clause 1.2
No. 1
APR Add the following NOTE:
2005
NOTE: Use of methods or information not given in this Standard should be justified by a special
study (see AS/NZS 1170.0).

AMDT Page 7 Clause 1.4


No. 1
APR Delete the last paragraph and replace with the following:
2005
The following wind actions, determined in accordance with this Standard (using the
procedures detailed in Section 2 and the values given in the remaining Sections), shall be
deemed to comply with the requirements of this Clause:
(a) W u determined using a regional wind speed appropriate to the annual probability of
exceedance (P) specified for ultimate limit states as given in AS/NZS 1170.0.
(b) W s determined using a regional wind speed appropriate to the annual probability of
exceedance for the serviceability limit states (see Note 3).
NOTES:
1 Information on serviceability conditions and criteria can be found in AS/NZS 1170.0 (see
Preface).
2 Some design processes require the determination of wind pressure (ultimate or serviceability
wind pressure). Such pressures should be calculated for the wind speed associated with the
annual probability of exceedance (P) appropriate to the limit state being considered.
3 For guidance on Item (b), see AS/NZS 1170.0.

AMDT Page 11 Clause 2.5.1


No. 1
APR Delete paragraph and replace with the following:
2005
Wind actions (W u and W s ) for use in AS/NZS 1170.0 shall be determined as given in
Clauses 2.5.2 to 2.5.5 and accelerations as given in Clause 2.5.6.

AMDT Page 13 Clause 3.2


No. 1
APR At the end of the first sentence add ‘(i.e., P for ultimate or serviceability limit states)’.
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007

2005

AMDT Page 13 Table 3.1


No. 1
APR Add the following row after ‘V20’:
2005

V 25 37 43 39 F C 47 F D 53

AMDT Page 13 Table 3.1, last row


No. 1
APR Insert multiplication symbol in columns 5 and 6 after F C and FD .
2005
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007

APR
2005
No. 1
AMDT Page 15 Figure 3.1
Delete Figure 3.1 and replace with the following:

FIGURE 3.1 (in part) WIND REGIONS


AMDT
Page 19 Table 4.2(A)
No. 1
APR Delete the last row from the Table.
2005

AMDT
Page 21 Clause 4.3.2
No. 1
APR 1 First line, delete ‘20ht’ and replace with ‘20h’.
2005
2 Second line, delete ‘h t’ and replace with ‘z’.

AMDT
Page 21 Clause 4.3.3
No. 1
APR Last line of the notation, delete ‘hs ≥ h’ and replace with ‘h s ≥ z’.
2005

AMDT
Page 23 Figure 4.4
No. 1
APR In Figure title delete ‘ GREATER THAN 0.44’ and replace with ‘GREATER THAN 0.45’.
2005

AMDT
Page 26 Figure 5.1 (in part)
No. 1
APR 1 Figure caption at the top of Page 26 should be at the bottom of Page 25.
2005
2 Caption (c), NOTE, last line, replace ‘ longitudibal’ with ‘longitudinal’.
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007
AMDT
Page 29 Figure 5.2
No. 1
APR Delete Figure 5.2 and replace with the following:
2005
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007

FIGURE 5.2 PARAMETERS FOR RECTANGULAR ENCLOSED BUILDINGS


AMDT
Page 30 Clause 5.4.1
No. 1
APR Delete third paragraph and Items (a), (b) and (c) and replace with the following:
2005
For roofs, the following alternative load cases shall be considered:
(a) When using Table 5.3(A) only, for the appropriate roof type, slope and edge
distance—
(i) apply the more negative value of Cp,e to all pressure zones and surfaces; and
(ii) apply the less negative (or most positive) value of C p,e to all pressure zones and
surfaces.
(b) When using both Tables 5.3(B) and 5.3(C), and for the appropriate parameters—
(i) apply the more negative value of Cp,e from Table 5.3(B) to the upwind slope
together with the value from Table 5.3(C) to the downwind slope; and
(ii) apply the less negative (or positive) value of Cp,e from Table 5.3(B) to the
upwind slope together with the value from Table 5.3(C) to the downwind slope.
(c) When using Table 5.3(C) only, for steeper crosswind slopes on hip roofs, apply the
appropriate C p,e value to both slopes.

AMDT
Page 30 Table 5.2(B)
No. 1
APR Delete the Table and replace with the following:
2005
TABLE 5.2(B)
WALLS—EXTERNAL PRESSURE COEFFICIENTS (C p,e) FOR
RECTANGULAR ENCLOSED BUILDINGS—LEEWARD WALL (L)
Wind direction Roof pitch
d/b External pressure
θ, degrees Roof shape α, degrees
(see Note 1) coefficients (C p,e )
(see Figure 2.2) (see Note 1)
≤1 −0.5
0 Hip or gable <10 2 −0.3
≥4 −0.2
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007

0 Hip or gable 10 −0.3


0 Hip or gable 15 All values −0.3
0 Hip or gable 20 −0.4
0 Hip or gable ≥25 ≤0.1 −0.75
≤1 −0.5
Gable
90 All values 2 −0.3
(see Note 2)
≥4 −0.2
NOTES:
1 For intermediate values of d/b and α, use linear interpolation.
2 For hip roofs use the same values as for θ = 0.
AMDT
Page 34 Table 5.6
No. 1
APR 1 Delete Column 4 and replace with the new column.
2005
2 Delete NOTE to Table and insert new NOTES.

Area, A

A ≤ 0.25a2

A ≤ a2
A ≤ 0.25a2
A ≤ a2
A ≤ 0.25a2
A ≤ a2
A ≤ 0.25a2
A ≤ 0.25a2
A ≤ a2
A ≤ 0.25a2

NOTES:
1 The dimension a and the Figure reference numbers are defined in Figure 5.3.
2 If an area of cladding is covered by more than one case in Table 5.6, use the largest value of K ℓ obtained
for any case.
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007
AMDT
Page 35 Figure 5.3
No. 1
APR Delete Figure 5.3 and replace with the following:
2005
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007

NOTE: The value of dimension a is the minimum of 0.2b, 0.2d and h.

FIGURE 5.3 LOCAL PRESSURE FACTORS (Kl )


AMDT
Page 38 Clause 6.2.2
No. 1 Add the following after the second sentence:
APR
2005
‘For the calculation of Cdyn , the value of Vdes,θ is calculated at the reference height, h (top of
the building or tower).’

AMDT
Page 39 Equation 6.2(2)
No. 1
APR Delete Equation 6.2(2) and replace with the following:
2005
1
Bs =
1+
[0.26(h − s) 2
+ 0.46bsh ]
2 0.5 . . . 6.2(2)

Lh

AMDT
Page 39 Equation 6.2(5)
No. 1
APR 1 Replace ‘n c’ with ‘n a’ and renumber Equation 6.2(5) to read 6.2(3).
2005
2 Renumber Equation 6.2(3) to read 6.2(4).
3 Renumber Equation 6.2(4) to read 6.2(5).

AMDT
Page 39 Clause 6.2.2
No. 1
APR In the definition of Vdes,θ add ‘determined at the building height, h’ after the words ‘wind
2005 speed’.

AMDT
Page 42 Equation 6.3(6)
No. 1
APR Replace ‘ − 0.028Vn3 ’ with ‘ − 0.0028V n3 ’.
2005

AMDT
Page 45 Equation 6.4(1)
No. 1
APR Delete Equation 6.4(1) and replace with the following:
2005
ε t = ε a,m + [(ε a,p − εa,m ) 2 + ε c,p 2]0.5
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007

AMDT
Page 45 Clause 6.4, Note
No. 1
APR Replace ‘2 gv ’ with ‘ 2g v’.
2005

AMDT
Page 54 Appendix B
No. 1
APR Add the following two rows after Notation ‘W’:
2005
W s = wind actions for serviceability limit states (determined using a regional wind speed
appropriate to the annual probability of exceedance for serviceability limit states)
W u = wind actions for ultimate limit states (determined using a regional wind speed
appropriate to the annual probability of exceedance specified for ultimate limit
states)
AMDT
Page 55 Appendix B
No. 1
APR 1 Delete the definition of θ a and replace with the following:
2005
θ a = angle of deviation of the wind stream from the line joining the centre of the
tower cross-section to the centre of the ancillary, in degrees
2 Definition ‘ρ air ’ delete ‘1.2 kg/m 3 ’ and replace with ‘1.2 kg/m 3’.

AMDT
Page 61 Paragraph C5
No. 1
APR Add the following new Paragraph after Figure C7:
2005
C5.2.3 Internal pressures in bins, silos and tanks
Internal pressures within bins, silos and tanks with vented roofs shall be determined as a an
area-weighted average of the external pressures at the position of the vents and openings,
determined according to Paragraph C5.2.2.
For open-top bins, silos or tanks, the internal pressure shall be determined as follows:
C fig = C p,i . . . 6.2(2)
= −0.9 − 0.35 log 10(c/b)
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007
AMDT
Page 61 Figure C7
No. 1
APR Delete Figure C7 and replace with the following:
2005
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007

FIGURE C7 EXTERNAL PRESSURE COEFFICIENTS (Cp,e) FOR ROOFS OF CIRCULAR


BINS, SILOS AND TANKS (0.25 < c/b < 4.0)

AMDT
Page 62 Table D1
No. 1
APR 1 Replace the text for Case 1 as follows:
2005
Pressures on an area between 0 and 1.0a2 within a distance 1.0a from a
roof edge, or a ridge with a pitch of 10° or more

2 Add the following NOTE after existing NOTE, and renumber as 1 and 2 respectively:
2 If an area of cladding is covered by more than one case in Table D1, the largest value of Kl shall
be used.
AMDT
Page 63 Equation D2
No. 1
APR Add the following NOTE after existing NOTE, and renumber as 1 and 2 respectively:
2005 2 Height for calculation of V des,θ is the top of the hoarding or wall (i.e., height (h), see
Figure D1).

AMDT
Page 63 Figure D1
No. 1
APR Delete Figure D1 and replace with the following (‘C p.n ’ corrected to ‘C p,n ’):
2005

FIGURE D1 FREESTANDING HOARDINGS AND WALLS

AMDT
Page 63 Table D2(A), Column 1, Second row
No. 1
APR Delete ‘0.2 to 5’ and replace with ‘0.5 to 5’.
2005

AMDT
Page 63 Table D2(B), Column 1, Second row
No. 1
APR Delete ‘0.2 to 5 inclusive’ and replace with ‘0.5 to 5 inclusive’.
2005

AMDT
Page 65 Paragraph D3.1
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007

No. 1
APR Add the following at the end:
2005
‘Where alternative pressure coefficient values are listed in Tables D4(A), D4(B), D5
and D6, for the appropriate roof slope, blockage and wind direction, all combinations of
values of C p,w and Cp,l shall be considered.
For θ = 90 degrees, and all configurations, the roof pitch is effectively zero, and
Table D4(A) shall be used to determine Cp,n .’

AMDT
Page 71 Paragraph D5
No. 1
APR Second paragraph, first line, delete ‘5.0(1 − x/l)’ and replace with ‘1.5(1 − x/l)’.
2005

AMDT
Page 73 Paragraph E2.2
No. 1
APR Item (a), delete and replace with the following:
2005
(a) For 0.2 < δe < 0.8 and 1/3 < (b/l) < 3 (where b/l is the aspect ratio of the whole
frame).
AMDT
Page 83 Paragraph E4.2.3
No. 1
APR Delete the definition of θ a and replace with the following:
2005
θ a = angle of deviation of the wind stream from the line joining the centre of the tower
cross-section to the centre of the ancillary, in degrees

AMDT
Page 84 Figure E4(a)
No. 1
APR Delete ‘θa = θ’ and replace with ‘θ a = 0’.
2005

AMDT
Page 85 Equation F1
No. 1
APR Add the following at the end of the equation:
2005
but not greater than 0.76

AMDT
Page 87 Paragraph G2
No. 1
APR Add I h in numerator as follows:
2005
SE t
ʕ ρ air g R I h
3 ζ  h h

=
m0 h 2 (1 + 2 g v I h ) 
C
 fig, windward ∑[ V des,θ ( z ]
)
2
b z z∆z − C [V
fig, leeward des ,θ (h ]∑
) 2
bz z∆z 

 z =0 z =0

. . . G2

AMDT
Page 88 Equation G3(2)
No. 1
APR Delete existing equation and replace with ‘ [2 × log e (600nc )] ’.
2005
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007
Accessed by CURTIN UNIVERSITY OF TECHNOLOGY on 03 Dec 2007