WDG

1200 & 1210


FLUE GAS OXYGEN ANALYSERS

i 0 to 25 % Oxygen Concentration

QUALITY CUSTOMER SOLUTIONS


WDG
1200 & 1210
AMETEK LAND HAS BEEN MANUFACTURING
PRECISION MEASURING EQUIPMENT SINCE 1947.
:($5(63(&,$/,676,1121ˎ&217$&77(03(5$785(0($685(0(17
AND COMBUSTION MONITORING WITH OUR PRODUCTS FINDING
APPLICATIONS ACROSS DIVERSE INDUSTRIES SUCH AS STEEL AND GLASS
MAKING, POWER GENERATION AND CEMENT MANUFACTURE.
As part of AMETEK Process & Analytical Instruments Division since 2006,
RXUFXVWRPHUVEHQHƋWIURPWKHZRUOGZLGH$0(7(.VDOHVDQGVHUYLFHWHDP

THE WDG SERIES IS A HIGHLY FLEXIBLE RANGE OF The unique sensor design allows the entire sensor
+,*+ˎ35(&,6,21)/8(*$62;<*(1$1$/<6(56 assembly, including the heater, to be removed without
'(9(/23('63(&,),&$//<)25&20%867,21 disturbing the outer protection tube which remains in
$1$/<6,6$1'&21752/$33/,&$7,216. the process; this makes field service fast and easy, and
because there is no need to return the probe to the
The WDG 1200 and 1210 are rugged and reliable for net factory for repair, there’s no expensive downtime.
oxygen and use industry-proven zirconium oxide sensor
technology. The outer probe tube is 310 stainless steel,
MODELS
so no abrasion shield is needed for most applications.
The integrated/remote controller features precision MODEL MAXIMUM FLUE READING
temperature control for optimum stability, built-in GAS TEMPERATURE DISPLAY
diagnostics, and over- temperature protection. Modbus
WDG 1200 0 - 677 °C / 32 - 1250 °F INTEGRATED
and 4-20 mA outputs are standard; automatic calibration
is available. WDG 1210 0 - 677 °C / 32 - 1250 °F REMOTE

F E AT U R E S

• Zircconia sensorr for acccurate


e and sensittive oxxygen
meeasurem ment
• Sim
mple In
nstallattion an
nd ope
eration
n
• 4-kkey use
er interrface contro
ols all fu
unctio
ons
• Serrvice and maaintenance carried
d out on site
• All parts are field replaceab
ble
• Straaightfo
orward
d integ
gration
n in plant co
ontrol system
m
• Me
easurem
ment system
ms for most applicationss
• Wid
de range of option
ns
• Ou
utstand
ding se
ensor reliability
• Mo
odbus RTU and 4-2
20 mA
A outpu
uts

WDG 1200 & 1210


SPECIFICATION
& DESIGN
6,03/(86(5,17(5)$&(Simple MODBUS COMMUNICATIONS
push-button operation combined WDG probes can communicate
with a clear LED display enable using the RS485 Modbus protocol,
complete electronic control of for straightforward integration
the probe functions. Full setup into the plant DCS. There are also
and diagnostic information is 4-20 mA analog and relay outputs.
also accessible through the user
interface. 9(56$7,/(352%(
AND MOUNTING
EASY MAINTENANCE The WDG oxygen probes are available
WDG 1200 / 1210 is fully field in various lengths with a range
serviceable. The unique design of mounting flange options. The
allows the inner tube structure dust-protection filter screws into
to be completely removed for the end of the probe and prevents
servicing, leaving the outer the sensor from being damaged by
protection tube attached to fly ash. The sensor is manufactured
the process. to the highest possible standards.
The sensor design gives a large
UNIQUE FLEXIBILITY surface area and an excellent bond
WDG uniquely mounts the user between the zirconia and stainless-
interface onto the probe itself. steel holder
This enables complete local
control at the measurement
location and reduces installation
costs. Alternatively, a remote user • COMBUSTION EFFICIENCY
interface can be supplied. The
Remote Calibration Unit allows
AND CONTROL
• NOx REDUCTION SYSTEMS
automated calibration for the
highest measurement accuracy.

• POLLUTION CONTROL

KEY MARKETS $33/,&$7,216


• Bio-fuel boilers • Combustion efficiency and control
• Package boilers • Gas, oil or coal fired boilers
• Power generation • NOx reduction systems
• CCGT • Shipyard boilers
• Petrochemicals • Excess air measurement
• Process industries • Pollution Control
• Pharmaceuticals
• Incineration furnaces

: : : $ 0 ( 7 ( . ˎ / $ 1 '  & 2 0   | L A N D. E N Q U I RY @ A M E T E K . CO M
WDG 1200 & 1210
FLUE GAS OXYGEN ANALYSERS

SPECIFICATIONS
Measurement Range: From 0 to 1 %, 0 to 25 % O2 v/v
Accuracy: ±1 % of measured value or ± 0.05 % oxygen, whichever is greater
Response Time: < 3 secs to calibration gas 63 % of a process step change, 20 secs
Drift: < 0.1 % of cell output per month (< 0.005 % O2 per month with 2 % O2 applied)
Linearity: ±1 % of output span
Repeatability: ±1 % of output span
3UREH/HQJWKV 0.22 m (9 in), 0.45 m (18 in), 0.9 m (36 in), 1.8 m (72 in)
Mounting Options: 2” NPT thread, 3” 300 lb ANSI, 2” 150 lb ANSI, 3” 150 lb ANSI, 4” 300 lb ANSI, DN65 PN6 (JIS)
Max Flue Gas Temperature: 677 °C (1250 °F)
6DPSOH3UHVVXUH ±2 psig (± 13.8 kPa)
Environment: Ambient Temp. : -20 to 71 °C (-5 to 160 °F)
Relative Humidity: 10 % to 90 %, non-condensing
Calibration Gas Requirement: Use all calibration gases @ 10 psig, 3 to 6 scfh (0.70 kg/cm2, 1.41 to 2.82 L/min) O2 Span Gas: Air or
from 1.0 % to 25 % O2, balance N2 O2 Zero Gas: 2 % or from 0.1 to 10% O2, balance N2
Calibration: Manual, automatic and remote trigger
352%(&21752/81,7
Display/Keypad: Single-line 4-digit LED; 4 keys
Analog Outputs: Isolated 4-20 mA. Max impedance 500 ohms. Current loop isolation is 1000 V rms
Alarms: System Fault, Maintenance, Calibration in Progress – Single pole form C 2A at 30 V ac/dc
Communications: Modbus, Isolated RS-485 2-wire
Environment: Ambient Temp.: -20 to 71 °C (-5 to 160 °F)
Relative Humidity: 10 % to 80 %, non-condensing
Enclosure: IP65
3RZHU5HTXLUHPHQWV Nominal 115-230 Vac ±10 %, 47-63 Hz; 4 A 6 mm female thread for earth grounding
System Compliance: EMC directive 89/336/EEC Low Voltage Directive 73/23/ EEC, CE
AUTOMATIC CALIBRATION UNIT
Dimensions: 300 x 200 x 155 mm / 11.8” x 7.9” x 6.1” (HxWxD)
:HLJKW 6 kg / 13.2 lbs.
Operating Temperature: 0 to 50 °C / 32 - 122 °F
Enclosure Rating: IP65
3RZHU6XSSO\ Selected to 110 v or 230 v a.c. 50-60 Hz 10VA
Supply Tolerance: -10 %, +20 %
*DV,QOHW3UHVVXUH 25 - 30 psi (1.7 to 2.0 bar)
*DV2XWOHW)ORZ 3 to 6 scfh (1.6 to 2.8 l/min)
3UHVVXUH6ZLWFK 15 psi (1.0 bar) trip pressure
Span (slave) Relays: 2 - galvanically free changeover relay contacts
Control Interface: Single 8 core hard wire lead to Genesis Control Unit
Fuse Rating: 125 mA @ 230v antisurge, 250 mA @ 110v antisurge
,VRODWLRQ6ZLWFK5DWLQJ 240V 1A (customer supplied)
Installation: Category II
Overvoltage: Category II

SEE OUR OTHER COMBUSTION AND EMISSIONS PRODUCT LITERATURE:

DISCOVER HOW OUR BROAD RANGE


FGA
FGA S
SERIES LANCOMdžDŽDŽ
LANC
PORTABLE AC
ACID DEWPOINT
COMPACT MULTIGAS
MUL CEMS TEMPERATURE MONITORING
TEMPERATUR

2)121ˎ&217$&77(03(5$785(
i Measures
Measu
ures CO O2 NO - Calculates CO2 and NOX
i Acid Dewpoint • SO3 • H2 SO4

LANCOM 200 MEASUREMENT AND COMBUSTION &


(0,66,216352'8&762))(5$
FGA SERIES ACID DEWPOINT 62/87,21)25<285352&(66
MULTIGAS CEMS MONITOR
QUALITY CUSTOMER SOLUTIONS
48$/,7<&86720(562/87,216

:::$0(7(.ˎ/$1'&20

CONTACT US
www.ametek-land.com

land.enquiry@ametek.com Certificate No. CC-2041


APPLIES IN INDIA APPLIES IN THE UK APPLIES IN THE US

MARCOM0496 WDG 1200 & 1210 Rev 2 Copyright © 2008-20 LAND Instruments International. Continuous product development may make it necessary to change these details without notice.

You might also like