01.catalogue MVAC-BRCM PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 52

PROJECT:

BRCM HQ

2020

MVAC CATALOGUE

CONTENTS

I. MVAC CATALOGUE
1. AIR CONDITIONING
2. COPPER PIPE
3. INSULATION
4. FILTER DRIER & SIGHT GLASS
5. FAN
6. GRILLE
I. MVAC CATALOGUE
1. AIR CONDITIONING
DAIKIN
PCTVSG1808aprv

VRV A SERIES Cooling Only 50 Hz


Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

VRV is a trademark of Daikin Industries, Ltd.


VRV Air Conditioning System is the world’s first individual air conditioning system with variable refrigerant flow control and was commercialised by Daikin in 1982.
VRV is the trademark of Daikin Industries, Ltd., which is derived from the technology we call “variable refrigerant volume.”

Specifications, designs and other content appearing in this brochure are current as of February 2018 but subject to change without notice.
Cooling Only 50 Hz
c All rights reserved
AK
VRV A Series Outdoor Units RXQ-A

Model RXQ6AYM RXQ8AYM RXQ10AYM RXQ12AYM RXQ14AYM RXQ16AYM RXQ16AMYM-SG RXQ18AYM RXQ18AMYM RXQ18AMYM-SG

VRV A SERIES
— — — — — — RXQ6AYM — RXQ8AYM RXQ6AYM
Combination units — — — — — — RXQ10AYM — RXQ10AYM RXQ12AYM
— — — — — — — — — —
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
Btu/h 54,600 76,400 95,500 114,000 136,000 154,000 150,000 171,000 172,000 169,000
Cooling capacity
kW 16.0 22.4 28.0 33.5 40.0 45.0 44.0 50.0 50.4 49.5
Power consumption kW 3.38 5.17 6.84 8.70 10.7 12.9 10.2 15.3 12.0 12.1
Capacity Control % 25-100 20-100 13-100 12-100 11-100 10-100 8-100 10-100 7-100 8-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor Motor Output x
kW 2.3×1 3.4×1 4.5×1 5.6×1 6.4×1 (3.5×1)+(3.5×1) (2.3×1)+(4.5×1) (4.0×1)+(4.0×1) (3.4×1)+(4.5×1) (2.3×1)+(5.6×1)
Number of Units
Airflow rate m3/min 119 178 191 257 257 119+178 257 178+178 119+191
(1,657×930×765)+
Dimensions (H×W×D) mm 1,657×930×765 1,657×1,240×765 1,657×1,240×765 1,657×1,240×765 (1,657×930×765)+(1,657×930×765)
(1,657×930×765)
Machine weight kg 175 185 215 260 175+185 260 175+185
Sound level dB(A) 56 57 59 60 60 60 61 60 61
Operation range °CDB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 5.9 6.7 6.8 7.4 8.2 5.9+6.7 8.4 5.9+6.7 5.9+6.8
Piping Liquid mm φ9.5 (Brazing) φ12.7 (Brazing) φ12.7 (Brazing) φ15.9 (Brazing)
connections Gas mm φ19.1 (Brazing) φ22.2 (Brazing) φ28.6 (Brazing) φ28.6 (Brazing)

Model RXQ20AYM RXQ20AMYM RXQ20AMYM-SG RXQ22AMYM RXQ24AMYM RXQ26AMYM RXQ28AMYM RXQ28AMYM-SG RXQ30AMYM RXQ30AMYM-SG
— RXQ8AYM RXQ10AYM RXQ10AYM RXQ12AYM RXQ12AYM RXQ12AYM RXQ14AYM RXQ12AYM RXQ8AYM
Combination units — RXQ12AYM RXQ10AYM RXQ12AYM RXQ12AYM RXQ14AYM RXQ16AYM RXQ14AYM RXQ18AYM RXQ10AYM
— — — — — — — — — RXQ12AYM
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
Btu/h 191,000 191,000 191,000 210,000 229,000 251,000 268,000 273,000 285,000 286,000
Cooling capacity
kW 56.0 55.9 56.0 61.5 67.0 73.5 78.5 80.0 83.5 83.9
Power consumption kW 17.7 13.9 13.7 15.5 17.4 19.4 21.6 21.4 24.0 20.7
Capacity Control % 7-100 7-100 6-100 6-100 6-100 6-100 5-100 5-100 5-100 5-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor Motor Output x
kW (3.8×1)+(6.3×1) (3.4×1)+(5.6×1) (4.5×1)+(4.5×1) (4.5×1)+(5.6×1) (5.6×1)+(5.6×1) (5.6×1)+(6.4×1) (5.6×1)+(3.5×1)+(3.5×1) (6.4×1)+(6.4×1) (5.6×1)+(4.0×1)+(4.0×1) (3.4×1)+(4.5×1)+(5.6×1)
Number of Units
Airflow rate m /min
3
297 178+191 178+178 178+191 191+191 191+257 257+257 191+257 178+178+191
(1,657×930×765)+
(1,657×1,240×765)+ (1,657×930×765)+
Dimensions (H×W×D) mm 1,657×1,240×765 (1,657×930×765)+(1,657×930×765) (1,657×930×765)+(1,657×1,240×765) (1,657×930×765)+
(1,657×1,240×765) (1,657×1,240×765)
(1,657×930×765)
Machine weight kg 285 175+185 185+185 185+215 185+260 215+215 185+260 175+185+185
Sound level dB(A) 65 61 60 61 62 63 62
Operation range °CDB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 11.8 5.9+6.8 6.7+6.7 6.7+6.8 6.8+6.8 6.8+7.4 6.8+8.2 7.4+7.4 6.8+8.4 5.9+6.7+6.8
Piping Liquid mm φ15.9 (Brazing) φ19.1 (Brazing)
connections Gas mm φ28.6 (Brazing) φ34.9 (Brazing) φ34.9 (Brazing)
Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.
When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

15 16
VRV A Series Outdoor Units RXQ-A

Model RXQ32AMYM RXQ32AMYM-SG RXQ34AMYM RXQ34AMYM-SG RXQ36AMYM RXQ36AMYM-SG RXQ38AMYM RXQ38AMYM-SG RXQ40AMYM RXQ40AMYM-SG RXQ42AMYM

VRV A SERIES
RXQ14AYM RXQ8AYM RXQ16AYM RXQ10AYM RXQ18AYM RXQ12AYM RXQ18AYM RXQ12AYM RXQ20AYM RXQ12AYM RXQ12AYM
Combination units RXQ18AYM RXQ12AYM RXQ18AYM RXQ12AYM RXQ18AYM RXQ12AYM RXQ20AYM RXQ12AYM RXQ20AYM RXQ14AYM RXQ12AYM
— RXQ12AYM — RXQ12AYM — RXQ12AYM — RXQ14AYM — RXQ14AYM RXQ18AYM
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
Btu/h 307,000 305,000 324,000 324,000 341,000 343,000 362,000 365,000 382,000 387,000 399,000
Cooling capacity
kW 90.0 89.4 95.0 95.0 100 101 106 107 112 114 117
Power consumption kW 26.0 22.6 28.2 24.2 30.6 26.1 33.0 28.1 35.4 30.1 32.7
Capacity Control % 5-100 5-100 5-100 4-100 5-100 4-100 4-100 4-100 3-100 4-100 4-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor Motor Output x (6.4×1)+(4.0×1)+ (3.4×1)+(5.6×1)+ (3.5×1)+(3.5×1)+ (4.5×1)+(5.6×1)+ (4.0×1)+(4.0×1)+ (4.0×1)+(4.0×1)+ (3.8×1)+(6.3×1)+ (5.6×1)+(5.6×1)+
kW (5.6×1)+(5.6×1)+(5.6×1) (5.6×1)+(5.6×1)+(6.4×1) (5.6×1)+(6.4×1)+(6.4×1)
Number of Units (4.0×1) (5.6×1) (4.0×1)+(4.0×1) (5.6×1) (4.0×1)+(4.0×1) (3.8×1)+(6.3×1) (3.8×1)+(6.3×1) (4.0×1)+(4.0×1)
Airflow rate m3/min 257+257 178+191+191 257+257 178+191+191 257+257 191+191+191 257+297 191+191+257 297+297 191+257+257 191+191+257
(1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+
(1,657×1,240×765)+ (1,657×1,240×765)+ (1,657×1,240×765)+ (1,657×1,240×765)+ (1,657×1,240×765)+
Dimensions (H×W×D ) mm (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×1,240×765)+ (1,657×930×765)+
(1,657×1,240×765) (1,657×1,240×765) (1,657×1,240×765) (1,657×1,240×765) (1,657×1,240×765)
(1,657×930×765) (1,657×930×765) (1,657×930×765) (1,657×1,240×765) (1,657×1,240×765) (1,657×1,240×765)
Machine weight kg 215+260 175+185+185 260+260 185+185+185 260+260 185+185+185 260+285 185+185+215 285+285 185+215+215 185+185+260
Sound level dB(A) 64 63 64 63 64 64 66 64 68 64 65
Operation range °CDB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 7.4+8.4 5.9+6.8+6.8 8.2+8.4 6.7+6.8+6.8 8.4+8.4 6.8+6.8+6.8 8.4+11.8 6.8+6.8+7.4 11.8+11.8 6.8+7.4+7.4 6.8+6.8+8.4
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ34.9 (Brazing) φ41.3 (Brazing) φ41.3 (Brazing)

Model RXQ42AMYM-SG RXQ44AMYM RXQ44AMYM-SG RXQ46AMYM RXQ48AMYM RXQ50AMYM RXQ52AMYM RXQ54AMYM RXQ56AMYM RXQ58AMYM RXQ60AMYM
RXQ14AYM RXQ12AYM RXQ14AYM RXQ14AYM RXQ14AYM RXQ14AYM RXQ16AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ20AYM
Combination units RXQ14AYM RXQ12AYM RXQ14AYM RXQ14AYM RXQ16AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ20AYM RXQ20AYM
RXQ14AYM RXQ20AYM RXQ16AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ20AYM RXQ20AYM RXQ20AYM
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
Btu/h 409,000 420,000 427,000 444,000 461,000 478,000 495,000 512,000 532,000 553,000 573,000
Cooling capacity
kW 120 123 125 130 135 140 145 150 156 162 168
Power consumption kW 32.1 35.1 34.3 36.7 38.9 41.3 43.5 45.9 48.3 50.7 53.1
Capacity Control % 4-100 3-100 3-100 3-100 3-100 3-100 3-100 3-100 3-100 2-100 2-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor Motor Output x (6.4×1)+(6.4×1)+ (5.6×1)+(5.6×1)+ (6.4×1)+(6.4×1)+ (6.4×1)+(6.4×1)+ (6.4×1)+(3.5×1)+ (6.4×1)+(4.0×1)+ (3.5×1)+(3.5×1)+(4.0×1)+ (4.0×1)+(4.0×1)+(4.0×1)+ (4.0×1)+(4.0×1)+(4.0×1)+ (4.0×1)+(4.0×1)+(3.8×1)+ (3.8×1)+(6.3×1)+(3.8×1)+
kW
Number of Units (6.4×1) (3.8×1)+(6.3×1) (3.5×1)+(3.5×1) (4.0×1)+(4.0×1) (3.5×1)+(4.0×1)+(4.0×1) (4.0×1)+(4.0×1)+(4.0×1) (4.0×1)+(4.0×1)+(4.0×1) (4.0×1)+(4.0×1)+(4.0×1) (4.0×1)+(3.8×1)+(6.3×1) (6.3×1)+(3.8×1)+(6.3×1) (6.3×1)+(3.8×1)+(6.3×1)
Airflow rate m3/min 257+257+257 191+191+297 257+257+257 257+257+257 257+257+297 257+297+297 297+297+297
(1,657×1,240×765)+ (1,657×930×765)+
Dimensions (H×W×D ) mm (1,657×1,240×765)+ (1,657×930×765)+ (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)
(1,657×1,240×765) (1,657×1,240×765)
Machine weight kg 215+215+215 185+185+285 215+215+260 215+260+260 215+260+260 260+260+260 260+260+285 260+285+285 285+285+285
Sound level dB(A) 65 67 65 65 66 68 69 70
Operation range °CDB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 7.4+7.4+7.4 6.8+6.8+11.8 7.4+7.4+8.2 7.4+7.4+8.4 7.4+8.2+8.4 7.4+8.4+8.4 8.2+8.4+8.4 8.4+8.4+8.4 8.4+8.4+11.8 8.4+11.8+11.8 11.8+11.8+11.8
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ41.3 (Brazing) φ41.3 (Brazing)
Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.
When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

17 18
VRV A Series Outdoor Units RXQ-A

Model RXQ32AMYM RXQ32AMYM-SG RXQ34AMYM RXQ34AMYM-SG RXQ36AMYM RXQ36AMYM-SG RXQ38AMYM RXQ38AMYM-SG RXQ40AMYM RXQ40AMYM-SG RXQ42AMYM

VRV A SERIES
RXQ14AYM RXQ8AYM RXQ16AYM RXQ10AYM RXQ18AYM RXQ12AYM RXQ18AYM RXQ12AYM RXQ20AYM RXQ12AYM RXQ12AYM
Combination units RXQ18AYM RXQ12AYM RXQ18AYM RXQ12AYM RXQ18AYM RXQ12AYM RXQ20AYM RXQ12AYM RXQ20AYM RXQ14AYM RXQ12AYM
— RXQ12AYM — RXQ12AYM — RXQ12AYM — RXQ14AYM — RXQ14AYM RXQ18AYM
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
Btu/h 307,000 305,000 324,000 324,000 341,000 343,000 362,000 365,000 382,000 387,000 399,000
Cooling capacity
kW 90.0 89.4 95.0 95.0 100 101 106 107 112 114 117
Power consumption kW 26.0 22.6 28.2 24.2 30.6 26.1 33.0 28.1 35.4 30.1 32.7
Capacity Control % 5-100 5-100 5-100 4-100 5-100 4-100 4-100 4-100 3-100 4-100 4-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor Motor Output x (6.4×1)+(4.0×1)+ (3.4×1)+(5.6×1)+ (3.5×1)+(3.5×1)+ (4.5×1)+(5.6×1)+ (4.0×1)+(4.0×1)+ (4.0×1)+(4.0×1)+ (3.8×1)+(6.3×1)+ (5.6×1)+(5.6×1)+
kW (5.6×1)+(5.6×1)+(5.6×1) (5.6×1)+(5.6×1)+(6.4×1) (5.6×1)+(6.4×1)+(6.4×1)
Number of Units (4.0×1) (5.6×1) (4.0×1)+(4.0×1) (5.6×1) (4.0×1)+(4.0×1) (3.8×1)+(6.3×1) (3.8×1)+(6.3×1) (4.0×1)+(4.0×1)
Airflow rate m3/min 257+257 178+191+191 257+257 178+191+191 257+257 191+191+191 257+297 191+191+257 297+297 191+257+257 191+191+257
(1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+
(1,657×1,240×765)+ (1,657×1,240×765)+ (1,657×1,240×765)+ (1,657×1,240×765)+ (1,657×1,240×765)+
Dimensions (H×W×D ) mm (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×930×765)+ (1,657×1,240×765)+ (1,657×930×765)+
(1,657×1,240×765) (1,657×1,240×765) (1,657×1,240×765) (1,657×1,240×765) (1,657×1,240×765)
(1,657×930×765) (1,657×930×765) (1,657×930×765) (1,657×1,240×765) (1,657×1,240×765) (1,657×1,240×765)
Machine weight kg 215+260 175+185+185 260+260 185+185+185 260+260 185+185+185 260+285 185+185+215 285+285 185+215+215 185+185+260
Sound level dB(A) 64 63 64 63 64 64 66 64 68 64 65
Operation range °CDB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 7.4+8.4 5.9+6.8+6.8 8.2+8.4 6.7+6.8+6.8 8.4+8.4 6.8+6.8+6.8 8.4+11.8 6.8+6.8+7.4 11.8+11.8 6.8+7.4+7.4 6.8+6.8+8.4
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ34.9 (Brazing) φ41.3 (Brazing) φ41.3 (Brazing)

Model RXQ42AMYM-SG RXQ44AMYM RXQ44AMYM-SG RXQ46AMYM RXQ48AMYM RXQ50AMYM RXQ52AMYM RXQ54AMYM RXQ56AMYM RXQ58AMYM RXQ60AMYM
RXQ14AYM RXQ12AYM RXQ14AYM RXQ14AYM RXQ14AYM RXQ14AYM RXQ16AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ20AYM
Combination units RXQ14AYM RXQ12AYM RXQ14AYM RXQ14AYM RXQ16AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ20AYM RXQ20AYM
RXQ14AYM RXQ20AYM RXQ16AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ18AYM RXQ20AYM RXQ20AYM RXQ20AYM
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
Btu/h 409,000 420,000 427,000 444,000 461,000 478,000 495,000 512,000 532,000 553,000 573,000
Cooling capacity
kW 120 123 125 130 135 140 145 150 156 162 168
Power consumption kW 32.1 35.1 34.3 36.7 38.9 41.3 43.5 45.9 48.3 50.7 53.1
Capacity Control % 4-100 3-100 3-100 3-100 3-100 3-100 3-100 3-100 3-100 2-100 2-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor Motor Output x (6.4×1)+(6.4×1)+ (5.6×1)+(5.6×1)+ (6.4×1)+(6.4×1)+ (6.4×1)+(6.4×1)+ (6.4×1)+(3.5×1)+ (6.4×1)+(4.0×1)+ (3.5×1)+(3.5×1)+(4.0×1)+ (4.0×1)+(4.0×1)+(4.0×1)+ (4.0×1)+(4.0×1)+(4.0×1)+ (4.0×1)+(4.0×1)+(3.8×1)+ (3.8×1)+(6.3×1)+(3.8×1)+
kW
Number of Units (6.4×1) (3.8×1)+(6.3×1) (3.5×1)+(3.5×1) (4.0×1)+(4.0×1) (3.5×1)+(4.0×1)+(4.0×1) (4.0×1)+(4.0×1)+(4.0×1) (4.0×1)+(4.0×1)+(4.0×1) (4.0×1)+(4.0×1)+(4.0×1) (4.0×1)+(3.8×1)+(6.3×1) (6.3×1)+(3.8×1)+(6.3×1) (6.3×1)+(3.8×1)+(6.3×1)
Airflow rate m3/min 257+257+257 191+191+297 257+257+257 257+257+257 257+257+297 257+297+297 297+297+297
(1,657×1,240×765)+ (1,657×930×765)+
Dimensions (H×W×D ) mm (1,657×1,240×765)+ (1,657×930×765)+ (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)
(1,657×1,240×765) (1,657×1,240×765)
Machine weight kg 215+215+215 185+185+285 215+215+260 215+260+260 215+260+260 260+260+260 260+260+285 260+285+285 285+285+285
Sound level dB(A) 65 67 65 65 66 68 69 70
Operation range °CDB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 7.4+7.4+7.4 6.8+6.8+11.8 7.4+7.4+8.2 7.4+7.4+8.4 7.4+8.2+8.4 7.4+8.4+8.4 8.2+8.4+8.4 8.4+8.4+8.4 8.4+8.4+11.8 8.4+11.8+11.8 11.8+11.8+11.8
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ41.3 (Brazing) φ41.3 (Brazing)
Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.
When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

17 18
Indoor Unit Lineup VRV Indoor Units

Ceiling Mounted Duct Type FXMQ-PA / MA

Specifications
Middle and high static pressure MODEL FXMQ20PAVE FXMQ25PAVE FXMQ32PAVE FXMQ40PAVE FXMQ50PAVE
allows for flexible duct design Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h 7,500 9,600 12,300 15,400 19,100
Cooling capacity
kW 2.2 2.8 3.6 4.5 5.6
Power consumption kW 0.056 1 0.056 1 0.060 1 0.151 1 0.128 1

Casing Galvanised steel plate


Using a DC fan motor, the external static pressure can
be controlled within a range of 30 Pa* to 200 Pa*. m3/min 9/7.5/6.5 9/7.5/6.5 9.5/8/7 16/13/11 18/16.5/15
Airflow rate (HH/H/L)
cfm 318/265/230 318/265/230 335/282/247 565/459/388 635/582/530
Adjustable external static pressure External static pressure Pa 30-100 (50) 2 30-100 (50) 2 30-100 (50) 2 30-160 (100) 2 50-200 (100) 2

Sound level (HH/H/L) dB(A) 33/31/29 33/31/29 34/32/30 39/37/35 41/39/37


Dimensions (H×W×D) mm 300x550x700 300x550x700 300x550x700 300x700x700 300x1,000x700
30 Pa* 200 Pa* Machine weight kg 25 25 25 27 35
Liquid (Flare) 6.4 6.4 6.4 6.4 6.4
Piping
Gas (Flare) mm 12.7 12.7 12.7 12.7 12.7
connections
Set to low static Set to high static pressure for
Drain VP25 (External Dia, 32/Internal Dia, 25)
pressure when ducts advanced needs such as when
are short. using dampers and long ducts. MODEL FXMQ63PAVE FXMQ80PAVE FXMQ100PAVE FXMQ125PAVE FXMQ140PAVE
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Comfortable airflow is achieved in accordance with Cooling capacity
Btu/h 24,200 30,700 38,200 47,800 54,600
conditions such as duct length. kW 7.1 9.0 11.2 14.0 16.0
Power consumption kW 0.138 1 0.185 1 0.215 1 0.284 1 0.405 1
*30 Pa–100 Pa for FXMQ20P-32PA
Casing Galvanised steel plate
*30 Pa–160 Pa for FXMQ40PA
*50 Pa–200 Pa for FXMQ50PA-125PA m3/min 19.5/17.5/16 25/22.5/20 32/27/23 39/33/28 46/39/32
Airflow rate (HH/H/L)
*50 Pa–140 Pa for FXMQ140PA cfm 688/618/565 883/794/706 1,130/953/812 1,377/1,165/988 1,624/1,377/1,130
External static pressure Pa 50-200 (100) 2 50-200 (100) 2 50-200 (100) 2 50-200 (100) 2 50-140 (100) 2
All models are only 300 mm in height and the
Sound level (HH/H/L) dB(A) 42/40/38 43/41/39 43/41/39 44/42/40 46/45/43
weight of the FXMQ40-140PA has been reduced.
Dimensions (H×W×D) mm 300×1,000×700 300×1,000×700 300×1,400×700 300×1,400×700 300×1,400×700
Drain pump is equipped as Machine weight kg 35 35 45 45 46
standard accessory with 700 mm Liquid (Flare) 9.5 9.5 9.5 9.5 9.5
700 mm lift. Piping
Gas (Flare) mm 15.9 15.9 15.9 15.9 15.9
Separate drain pipe connections
Ceiling
Easy maintenance and inspection opening Drain VP25 (External Dia, 32/Internal Dia, 25)
Control of the airflow rate can be selected from 3-step Inspection and cleaning is Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
control and Auto. Auto airflow rate control can be facilitated by separating the •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
selected with wired remote controller BRC1E63. drain pipe and inspection During actual operation, these values are normally somewhat higher as a result of ambient conditions.
1: Power consumption values are based on conditions of rated external static pressure.
2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32PA), thirteen (FXMQ40PA), fourteen (FXMQ50-125PA) or ten (FXMQ140PA) levels of
Low operation sound level opening and by the drain pan control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ20-32PA and 100 Pa for FXMQ40-140PA.

maintenance check hole.


Energy-efficient Drain pan maintenance
check hole MODEL FXMQ200MAVE FXMQ250MAVE

Indoor Unit Lineup


DC fan motor is used to realise energy-saving
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
operation. An antibacterial treatment that uses silver ions has Btu/h 76,400 95,500
Cooling capacity
Easy installation been applied to the drain pan, preventing the kW 22.4 28.0
Airflow rate can be controlled using a remote controller growth of slime, mould and bacteria that cause Power consumption kW 1.294 1
1.465 1

during test operation. It is automatically adjusted to the blockages and odours. (The lifespan of a silver ion Casing Galvanised steel plate
range between approximately ±10% of the rated HH tap cartridge depends on the usage environment, but m3/min 58/50 72/62
Airflow rate (H/L)
airflow for FXMQ20P–125PA. should be changed once every two to three years.) cfm 2,047/1,765 2,542/2,189
External static pressure Pa 132-221 2 191-270 2

220 V 48/45 48/45


Sound level (H/L) dB(A)
Simplified Static Built-in Drain Pump (Option) 240 V 49/46 49/46
Pressure Control Housing the drain pump inside the unit reduces the Dimensions (H×W×D) mm 470×1,380×1,100 470×1,380×1,100
External static pressure can space required for installation. kg
Machine weight 137 137
be easily adjusted using a Without drain pump With drain pump
change-over switch inside Liquid (Flare) 9.5 9.5
Piping mm
the electrical box to meet the 0–250 connections
Gas (Brazing) 19.1 22.2
resistance in the duct mm
Drain PS1B
system. 470 mm 470 mm
FXMQ200/250MA 222 mm
Note: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
25 mm • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Indoor unit Indoor unit
1: Power consumption values are based on conditions of standard external static pressure.
2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure".

41 42
Indoor Unit Lineup VRV Indoor Units

Ceiling Mounted Duct Type FXMQ-PA / MA

Specifications
Middle and high static pressure MODEL FXMQ20PAVE FXMQ25PAVE FXMQ32PAVE FXMQ40PAVE FXMQ50PAVE
allows for flexible duct design Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h 7,500 9,600 12,300 15,400 19,100
Cooling capacity
kW 2.2 2.8 3.6 4.5 5.6
Power consumption kW 0.056 1 0.056 1 0.060 1 0.151 1 0.128 1

Casing Galvanised steel plate


Using a DC fan motor, the external static pressure can
be controlled within a range of 30 Pa* to 200 Pa*. m3/min 9/7.5/6.5 9/7.5/6.5 9.5/8/7 16/13/11 18/16.5/15
Airflow rate (HH/H/L)
cfm 318/265/230 318/265/230 335/282/247 565/459/388 635/582/530
Adjustable external static pressure External static pressure Pa 30-100 (50) 2 30-100 (50) 2 30-100 (50) 2 30-160 (100) 2 50-200 (100) 2

Sound level (HH/H/L) dB(A) 33/31/29 33/31/29 34/32/30 39/37/35 41/39/37


Dimensions (H×W×D) mm 300x550x700 300x550x700 300x550x700 300x700x700 300x1,000x700
30 Pa* 200 Pa* Machine weight kg 25 25 25 27 35
Liquid (Flare) 6.4 6.4 6.4 6.4 6.4
Piping
Gas (Flare) mm 12.7 12.7 12.7 12.7 12.7
connections
Set to low static Set to high static pressure for
Drain VP25 (External Dia, 32/Internal Dia, 25)
pressure when ducts advanced needs such as when
are short. using dampers and long ducts. MODEL FXMQ63PAVE FXMQ80PAVE FXMQ100PAVE FXMQ125PAVE FXMQ140PAVE
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Comfortable airflow is achieved in accordance with Cooling capacity
Btu/h 24,200 30,700 38,200 47,800 54,600
conditions such as duct length. kW 7.1 9.0 11.2 14.0 16.0
Power consumption kW 0.138 1 0.185 1 0.215 1 0.284 1 0.405 1
*30 Pa–100 Pa for FXMQ20P-32PA
Casing Galvanised steel plate
*30 Pa–160 Pa for FXMQ40PA
*50 Pa–200 Pa for FXMQ50PA-125PA m3/min 19.5/17.5/16 25/22.5/20 32/27/23 39/33/28 46/39/32
Airflow rate (HH/H/L)
*50 Pa–140 Pa for FXMQ140PA cfm 688/618/565 883/794/706 1,130/953/812 1,377/1,165/988 1,624/1,377/1,130
External static pressure Pa 50-200 (100) 2 50-200 (100) 2 50-200 (100) 2 50-200 (100) 2 50-140 (100) 2
All models are only 300 mm in height and the
Sound level (HH/H/L) dB(A) 42/40/38 43/41/39 43/41/39 44/42/40 46/45/43
weight of the FXMQ40-140PA has been reduced.
Dimensions (H×W×D) mm 300×1,000×700 300×1,000×700 300×1,400×700 300×1,400×700 300×1,400×700
Drain pump is equipped as Machine weight kg 35 35 45 45 46
standard accessory with 700 mm Liquid (Flare) 9.5 9.5 9.5 9.5 9.5
700 mm lift. Piping
Gas (Flare) mm 15.9 15.9 15.9 15.9 15.9
Separate drain pipe connections
Ceiling
Easy maintenance and inspection opening Drain VP25 (External Dia, 32/Internal Dia, 25)
Control of the airflow rate can be selected from 3-step Inspection and cleaning is Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
control and Auto. Auto airflow rate control can be facilitated by separating the •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
selected with wired remote controller BRC1E63. drain pipe and inspection During actual operation, these values are normally somewhat higher as a result of ambient conditions.
1: Power consumption values are based on conditions of rated external static pressure.
2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32PA), thirteen (FXMQ40PA), fourteen (FXMQ50-125PA) or ten (FXMQ140PA) levels of
Low operation sound level opening and by the drain pan control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ20-32PA and 100 Pa for FXMQ40-140PA.

maintenance check hole.


Energy-efficient Drain pan maintenance
check hole MODEL FXMQ200MAVE FXMQ250MAVE

Indoor Unit Lineup


DC fan motor is used to realise energy-saving
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
operation. An antibacterial treatment that uses silver ions has Btu/h 76,400 95,500
Cooling capacity
Easy installation been applied to the drain pan, preventing the kW 22.4 28.0
Airflow rate can be controlled using a remote controller growth of slime, mould and bacteria that cause Power consumption kW 1.294 1
1.465 1

during test operation. It is automatically adjusted to the blockages and odours. (The lifespan of a silver ion Casing Galvanised steel plate
range between approximately ±10% of the rated HH tap cartridge depends on the usage environment, but m3/min 58/50 72/62
Airflow rate (H/L)
airflow for FXMQ20P–125PA. should be changed once every two to three years.) cfm 2,047/1,765 2,542/2,189
External static pressure Pa 132-221 2 191-270 2

220 V 48/45 48/45


Sound level (H/L) dB(A)
Simplified Static Built-in Drain Pump (Option) 240 V 49/46 49/46
Pressure Control Housing the drain pump inside the unit reduces the Dimensions (H×W×D) mm 470×1,380×1,100 470×1,380×1,100
External static pressure can space required for installation. kg
Machine weight 137 137
be easily adjusted using a Without drain pump With drain pump
change-over switch inside Liquid (Flare) 9.5 9.5
Piping mm
the electrical box to meet the 0–250 connections
Gas (Brazing) 19.1 22.2
resistance in the duct mm
Drain PS1B
system. 470 mm 470 mm
FXMQ200/250MA 222 mm
Note: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
25 mm • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Indoor unit Indoor unit
1: Power consumption values are based on conditions of standard external static pressure.
2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure".

41 42
Indoor Unit Lineup VRV Indoor Units

Wall Mounted Type FXAQ-P Floor Standing Type FXLQ-MA

Stylish flat panel design harmonised Suitable for perimeter zone air conditioning
with your interior décor

Stylish flat panel design creates a graceful harmony that Discharge angle is automatically set at the same angle as
enhances any interior space. the previous operation when restarting. (Initial setting: 10°
for cooling) Floor Standing types can be hung on the wall for easier
Flat panel can be cleaned with only the single pass of a cloth cleaning. Running the piping from the back allows the
across their smooth surface. Flexible installation unit to be hung on walls. Cleaning under the unit, where
Flat panel can also be easily removed and washed for more dust tends to accumulate, is considerably easier.
Drain pipe can be fitted to from either left or right sides.
thorough cleaning.

Low operation sound level Drain pump kit is available as optional accessory, which
The adoption of a fibre-less discharge grille featuring an
lifts the drain 1,000 mm from the bottom of the unit. original design to prevent condensation also helps
Drain pan and air filter can be kept clean by mould-proof prevent staining and makes cleaning easier.
polystyrene. Height of drain-up Wall hanging Floor installation

Vertical auto-swing realises efficiency of air distribution. A long-life filter (maintenance free up to one year*) is
The louvre closes automatically when the unit stops. 1,000 mm equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

5 steps of discharge angle can be set by remote controller.


Indoor unit
Drain pump kit

Specifications Specifications
MODEL FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE MODEL FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Cooling capacity Cooling capacity
kW 2.2 2.8 3.6 4.5 5.6 7.1 kW 2.2 2.8 3.6 4.5 5.6 7.1
Power consumption kW 0.019 0.028 0.030 0.020 0.033 0.050 Power consumption kW 0.049 0.049 0.090 0.090 0.110 0.110
Casing White (3.0Y8.5/0.5) Casing Ivory white (5Y7.5/1)
m3/min 7.5/4.5 8/5 8.5/5.5 12/9 15/12 19/14 m3/min 7/6 7/6 8/6 11/8.5 14/11 16/12
Airflow rate (H/L) Airflow rate (H/L)
cfm 265/159 282/177 300/194 424/318 530/424 671/494 cfm 247/212 247/212 282/212 388/300 494/388 565/424
Sound level (H/L) dB(A) 35/31 36/31 38/31 39/34 42/37 47/41 220 V 35/32 35/32 35/32 38/33 39/34 40/35

Indoor Unit Lineup


Sound level (H/L) dB(A)
Dimensions (H×W×D) mm 290×795×238 290×795×238 290×795×238 290×1,050×238 290×1,050×238 290×1,050×238 240 V 37/34 37/34 37/34 40/35 41/36 42/37
Machine weight kg 11.0 11.0 11.0 14.0 14.0 14.0 Dimensions
mm 600×1,000×222 600×1,000×222 600×1,140×222 600×1,140×222 600×1,420×222 600×1,420×222
Liquid (Flare) 6.4 6.4 6.4 6.4 6.4 9.5 (H×W×D)
Piping
connections Gas (Flare) mm 12.7 12.7 12.7 12.7 12.7 15.9 Machine weight kg 25.0 25.0 30.0 30.0 36.0 36.0
Drain VP13 (External Dia, 18/Internal Dia, 13) Liquid (Flare) 6.4 6.4 6.4 6.4 6.4 9.5
Piping Gas (Flare) mm 12.7 12.7 12.7 12.7 12.7 15.9
Note: Specifications are based on the following conditions; connections
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. Drain 21O.D.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. Note: Specifications are based on the following conditions;
During actual operation, these values are normally somewhat higher as a result of ambient conditions. • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

45 46
3. COPPER PIPE
3. INSULATION
4. FILTER DRIER & SIGHT GLASS
Data sheet

ELIMINATOR® Hermetic filter drier


Types DCL and DML

All ELIMINATOR® driers have a solid core with


binding material held to an absolute minimum.

There are two types of ELIMINATOR® cores.


Type DML driers have a core composition of
100% Molecular Sieve, while type DCL contain 80%
Molecular Sieve with 20% activated alumina.

ELIMINATOR® type DML driers are designed for


applications requiring the highest moisture
capacity.

ELIMINATOR® type DCL driers are designed for


applications requiring high moisture capacity and
acid adsorption capacity.

Available with solder (pure copper) and flare


connections.

Features The Core type DML The Shell


• 100% 3Å Molecular Sieve core • UL approved for MWP 667 psig
• High drying capacity minimizing the risk of acid • Available with solder (pure copper) and flare
formation (hydrolysis) connections
• Recommended for use with HFO, HC, HFC and • Corrosion resistant powder-painted finish.
HCFC refrigerants Special coating for marine applications available
• Will not deplete oil additives upon request
• Allows installation with any orientation provided
The Core type DCL the arrow is in the flow direction
• 80% 3Å Molecular Sieve with 20% activated • Available in sizes 3 – 75 cubic inches
alumina
• Perfect core blend for systems that operate at The Filter
high condensing temperatures and require high • 25 μm (0.001 in.) filter provides high retention
drying capacity with minimal pressure drop
• Recommended for use with HFO, HC, HFC and • Thermally stable up to 250 °F
HCFC refrigerants

© Danfoss | DCS (az) | 2016.04 DKRCC.PD.EB0.B4.22 | 520H10985 | 1


Data sheet | ELIMINATOR® Hermetic filter drier, types DCL and DML

Technical data and capacities

Drying and liquid capacity, type DML


Drying capacity [lb] refrigerant 1) Liquid capacity [TR] 2)
R134a R404A R507 R22 R407C R410A R32
Type
[°F] R134a R404A R507 R22 R407C R410A R32
75 125 75 125 75 125 75 125 75 125 75 125 75 125
DML 1.52s 6.4 6.0 6.8 6.6 7.1 6.4 6.4 6.0 6.4 6.0 5.7 5.3 6.0 5.5 1.70 1.20 1.10 1.80 1.70 1.70 2.50
DML 1.52x2/2s 6.4 6.0 6.8 6.6 7.1 6.4 6.4 6.0 6.4 6.0 5.7 5.3 6.0 5.5 1.70 1.20 1.10 1.80 1.70 1.70 2.50
DML 032/032s 10.9 10.3 11.8 11.2 12.0 11.1 11.1 10.3 11.0 10.1 10.0 9.2 10.1 9.3 1.90 1.42 1.38 2.12 2.02 2.11 3.09
DML 032.5s 10.9 10.3 11.8 11.2 12.0 11.1 11.1 10.3 11.0 10.1 10.0 9.2 10.1 9.3 2.73 1.98 1.92 2.99 2.84 2.93 4.30
DML 033/033s 10.9 10.3 11.8 11.2 12.0 11.1 11.1 10.3 11.0 10.1 10.0 9.2 10.1 9.3 3.65 2.80 2.72 4.11 3.94 4.17 6.10
DML 034s 10.9 10.3 11.8 11.2 12.0 11.1 11.1 10.3 11.0 10.1 10.0 9.2 10.1 9.3 7.03 5.72 5.56 8.13 7.86 8.57 12.47
DML 052/052s 17.4 16.5 18.7 17.8 19.1 17.6 17.6 16.3 17.5 16.1 15.9 14.6 16.1 14.8 2.18 1.60 1.55 2.40 2.28 2.37 3.47
DML 052.5s 17.4 16.5 18.7 17.8 19.1 17.6 17.6 16.3 17.5 16.1 15.9 14.6 16.1 14.8 2.72 1.99 1.93 3.00 2.85 2.95 4.33
DML 053/053s 17.4 16.5 18.7 17.8 19.1 17.6 17.6 16.3 17.5 16.1 15.9 14.6 16.1 14.8 3.66 2.79 2.71 4.10 3.92 4.15 6.06
DML 054s 17.4 16.5 18.7 17.8 19.1 17.6 17.6 16.3 17.5 16.1 15.9 14.6 16.1 14.8 7.31 5.91 5.74 8.43 8.14 8.83 12.87
DML 055s 17.4 16.5 18.7 17.8 19.1 17.6 17.6 16.3 17.5 16.1 15.9 14.6 16.1 14.8 10.30 8.26 8.03 11.84 11.42 12.35 18.00
DML 082/082s 27.9 26.3 29.9 28.4 30.5 28.2 28.2 26.1 27.9 25.8 25.4 23.4 25.8 23.8 2.18 1.55 1.50 2.37 2.23 2.28 3.35
DML 082.5s 27.9 26.3 29.9 28.4 30.5 28.2 28.2 26.1 27.9 25.8 25.4 23.4 25.8 23.8 3.00 2.23 2.16 3.32 3.16 3.31 4.85
DML 083/083s 27.9 26.3 29.9 28.4 30.5 28.2 28.2 26.1 27.9 25.8 25.4 23.4 25.8 23.8 4.03 3.12 3.03 4.56 4.37 4.65 6.79
DML 084/084s 27.9 26.3 29.9 28.4 30.5 28.2 28.2 26.1 27.9 25.8 25.4 23.4 25.8 23.8 8.14 6.07 5.88 9.03 8.60 8.99 13.17
DML 085/085s 27.9 26.3 29.9 28.4 30.5 28.2 28.2 26.1 27.9 25.8 25.4 23.4 25.8 23.8 12.46 10.04 9.76 14.35 13.85 15.02 21.88
DML 162/162s 61.2 57.8 65.7 62.3 66.9 61.8 61.9 57.3 61.3 56.6 55.8 51.4 56.4 52.0 2.18 1.54 1.50 2.36 2.23 2.28 3.35
DML 162.5s 61.2 57.8 65.7 62.3 66.9 61.8 61.9 57.3 61.3 56.6 55.8 51.4 56.4 52.0 3.01 2.09 2.02 3.23 3.04 3.08 4.53
DML 163/163s 61.2 57.8 65.7 62.3 66.9 61.8 61.9 57.3 61.3 56.6 55.8 51.4 56.4 52.0 4.64 3.18 3.08 4.95 4.64 4.67 6.88
DML 164/164s 61.2 57.8 65.7 62.3 66.9 61.8 61.9 57.3 61.3 56.6 55.8 51.4 56.4 52.0 9.15 6.69 6.49 10.07 9.55 9.90 14.53
DML 165/165s 61.2 57.8 65.7 62.3 66.9 61.8 61.9 57.3 61.3 56.6 55.8 51.4 56.4 52.0 12.69 10.41 10.12 14.74 14.26 15.59 22.69
DML 166/166s 61.2 57.8 65.7 62.3 66.9 61.8 61.9 57.3 61.3 56.6 55.8 51.4 56.4 52.0 12.95 10.63 10.34 15.04 14.56 15.93 23.17
DML 167s 61.2 57.8 65.7 62.3 66.9 61.8 61.9 57.3 61.3 56.6 55.8 51.4 56.4 52.0 12.49 11.41 11.14 15.21 15.01 17.34 25.01
DML 303/303s 127.2 120.2 136.7 129.6 139.2 128.6 128.8 119.1 127.5 117.8 116.0 106.9 117.5 108.5 4.46 3.00 2.90 4.72 4.41 4.40 6.49
DML 304/304s 127.2 120.2 136.7 129.6 139.2 128.6 128.8 119.1 127.5 117.8 116.0 106.9 117.5 108.5 9.24 7.11 6.90 10.41 9.97 10.58 15.46
DML 305/305s 127.2 120.2 136.7 129.6 139.2 128.6 128.8 119.1 127.5 117.8 116.0 106.9 117.5 108.5 13.00 10.51 10.22 14.99 14.48 15.72 22.90
DML 306/306s 127.2 120.2 136.7 129.6 139.2 128.6 128.8 119.1 127.5 117.8 116.0 106.9 117.5 108.5 12.43 11.34 11.07 15.13 14.92 17.22 24.85
DML 307s 127.2 120.2 136.7 129.6 139.2 128.6 128.8 119.1 127.5 117.8 116.0 106.9 117.5 108.5 18.27 15.34 14.93 21.44 20.84 23.05 33.48
DML 309s 127.2 120.2 136.7 129.6 139.2 128.6 128.8 119.1 127.5 117.8 116.0 106.9 117.5 108.5 23.78 19.84 19.31 27.83 27.02 29.79 32.61
DML 413 171.6 162.2 184.5 174.9 187.8 173.5 173.8 160.7 172.0 158.9 156.6 144.3 158.5 146.2 5.23 3.54 3.42 5.54 5.19 5.19 7.65
DML 414/414s 171.6 162.2 184.5 174.9 187.8 173.5 173.8 160.7 172.0 158.9 156.6 144.3 158.5 146.2 9.49 7.52 7.31 10.85 10.44 11.23 16.38
DML 415/415s 171.6 162.2 184.5 174.9 187.8 173.5 173.8 160.7 172.0 158.9 156.6 144.3 158.5 146.2 15.78 11.90 11.54 17.61 16.80 17.66 25.85
DML 417s 171.6 162.2 184.5 174.9 187.8 173.5 173.8 160.7 172.0 158.9 156.6 144.3 158.5 146.2 18.98 16.01 15.59 22.32 21.71 24.08 34.96
DML 419s 171.6 162.2 184.5 174.9 187.8 173.5 173.8 160.7 172.0 158.9 156.6 144.3 158.5 146.2 27.10 21.69 21.08 31.11 29.99 32.42 47.25
DML 604s 257.6 243.5 276.9 262.5 281.9 260.4 260.9 241.2 258.2 238.6 235.0 216.5 237.9 219.6 7.93 7.45 7.29 9.77 9.69 11.37 16.36
DML 607s 257.6 243.5 276.9 262.5 281.9 260.4 260.9 241.2 258.2 238.6 235.0 216.5 237.9 219.6 19.93 19.94 19.54 25.16 25.22 30.71 43.90
DML 609s 257.6 243.5 276.9 262.5 281.9 260.4 260.9 241.2 258.2 238.6 235.0 216.5 237.9 219.6 17.45 20.77 20.59 23.25 23.99 33.37 46.38
DML 757s 352.3 333.0 378.7 359.0 385.5 356.1 356.8 329.9 353.0 326.2 321.3 296.1 325.2 300.0 24.16 20.39 19.85 28.42 27.65 30.66 44.51
DML 759s 352.3 333.0 378.7 359.0 385.5 356.1 356.8 329.9 353.0 326.2 321.3 296.1 325.2 300.0 23.95 24.79 24.34 30.61 30.86 38.41 54.69
1
) Drying capacity is based on following moisture content test standards before and after drying:
–– R32: 990 ppm W - 50 ppm W
–– R134a: 1050 ppm W – 50 ppm W
–– R404A, R507: 1020 ppm W – 50 ppm W
–– R407C: 1020 ppm W – 50 ppm W
–– R410A: 1050 ppm W – 50 ppm W
–– R22: 1050 ppm W – 60 ppm W
in accordance with ARI 710-2004

) Given in accordance with ARI 710-2004 for


2

–– te= 5 °F
–– tc= 85 °F
–– Δp = 1 psi

For technical data on other refrigerants, please contact your Danfoss Sales Representative

© Danfoss | DCS (az) | 2016.04 DKRCC.PD.EB0.B4.22 | 520H10985 | 3


Data sheet | ELIMINATOR® Hermetic filter drier, types DCL and DML

Ordering Type DML Solder (copper)


(continued) Industrial pack Industrial pack
Conn. Multi pack Conn. Multi pack
Type for OEM only for OEM only
[in.] Code no. Qty. Code no. Qty. [mm] Code no. Qty. Code no. Qty.
DML 1.52s 1
⁄4 – – 023Z8253 36 – – – – –
DML 1.52x2/2s 1
⁄4 – – 023Z8250 36 – – – – –
23Z8410.10

DML 032s 1
⁄4 023Z5048 1) 32 023Z8048 1) 28 6 – – 023Z8047 28
Danfoss

DML 032.5s 5
⁄16 023Z5049 32 – – 8 – – – –
DML 033s 3
⁄8 023Z5050 32 023Z8050 28 10 023Z5051 32 – –
DML 034s 3
⁄8 023Z5121 32 – – 12 – – – –
DML 052s 1
⁄4 023Z5053 24 — — 6 023Z5052 24 – –
DML 053s 3
⁄8 023Z5054 24 023Z8054 16 10 023Z5055 24 023Z8055 16
23Z8405.10
Danfoss

DML 054s 1
⁄2 023Z5101 24 – – – – – – –
DML 055s 5
⁄8 023Z5100 24 – – 16 023Z5100 24 – –
DML 082s 1
⁄4 023Z5057 24 – – 6 – – – –
DML 082.5s 5
⁄16 023Z5117 24 – – 8 – – – –
DML 083s 3
⁄8 023Z5058 24 – – 10 023Z5059 24 – –
DML 084s 1
⁄2 023Z5061 24 – – 12 023Z5060 24 – –
DML 085s 5
⁄8 023Z5072 24 – – 16 – – – –
DML 162s 1
⁄4 023Z5063 12 – – 6 – – – –
DML 163s 3
⁄8 023Z5064 12 – – 10 023Z5065 12 – –
DML 164s 1
⁄2 023Z5067 12 023Z8067 12 12 023Z5066 12 – –
DML 165s 5
⁄8 023Z5068 12 023Z8068 12 16 – – – –
23Z8404
Danfoss

DML 166s 3
⁄4 023Z5071 12 023Z8071 12 19 – – – –
DML 167s 7 8
/ 023Z5069 12 – – 22 – – – –
DML 303s 3
⁄8 023Z0067 8 – – 10 – – – –
DML 304s 1
⁄2 023Z0068 8 – – 12 – – – –
DML 305s 5
⁄8 023Z0069 8 023Z3069 8 16 – – – –
DML 306s 3
⁄4 023Z0070 8 – – 19 – – – –
DML 307s 7
⁄8 023Z0071 8 023Z3071 8 22 – – – –
DML 309s 11⁄8 023Z0072 8 – – 28 – – – –
DML 414s 1
⁄2 023Z0111 8 – – 12 – – – –
DML 415s 5
⁄8 023Z0112 8 – – 16 – – – –
DML 416s 3
⁄4 – – – – 19 023Z8246 8 – –
DML 417s 7
⁄8 023Z0113 8 – – 22 – – – –
DML 419s 11⁄8 023Z0114 8 023Z3114 6 28 – – – –
DML 604s 1
⁄2 – – – – 12 – – – –
DML 607s 7
⁄8 023Z0073 12 – – 22 – – – –
DML 609s 11⁄8 023Z0074 12 – – 28 – – – –
DML 757s 7
⁄8 023Z0117 12 – – 22 – – – –
DML 759s 11⁄8 023Z0118 12 – – 28 – – – –
) Wire mesh in filter drier outlet
1

© Danfoss | DCS (az) | 2016.04 DKRCC.PD.EB0.B4.22 | 520H10985 | 8


SGP - Sight Glasses
Danfoss sight glasses are designed to accurately indicate the The indication of dangerous moisture levels is essential in helping
presence of moisture in refrigeration and air-conditioning systems. prevent the formation of harmful acids which are detrimental to the
When system moisture content rises above permissible levels, the system.
“dry/green” indicator will change to yellow indicating a “wet” system.

Features
SGP

High visibility view port

Moisture indicator
• Green for dry
• Yellow for wet

Connections:
• Solder x Solder (illustrated)
• Flare external x external
• Flare internal x external
• Socket

Corrosion resistant
brass body design

Product Selection
Ambient Maximum working
Danfoss Connection Danfoss
Version temperature pressure
Type (in.) Code No.
(°F) (psig)

SGP 6 N 1/4 x 1/4 014L0171


Flare
SGP 10 N int. x ext.1 3/8 x 3/8 014L0172

SGP 12 N 1/2 x 1/2 014L0173

SGP 6s N 1/4 x 1/4 014L0181

SGP 10s N 3/8 x 3/8 –60 to 175 750 014L0182

SGP 12s N ODF x ODF solder 1/2 x 1/2 014L0183

SGP 16s N 5/8 x 5/8 014L0145

SGP 22s N 7/8 x 7/8 014L0186

SGP 1/2 RN NPT 1/2 014L0006

1
Can be screwed directly onto Danfoss filter drier.

34 Quick Select Guide


Installation guide

Sight glass
Type SGP X, SGP I, SGP N, SGP RX, SGP RI, SGP RN, SGR, SGI, SGRI, SGN, SGRN
014R9572

014R9572
Refrigerant: SGP (I indicator): R290, R600, R600a, R22
SGP (N indicator): R410A, R404A, R507, R134a, R407C, R32, R22, R1270, R744, R407A, R407F, R448A,
R449A, R450A, R452A, R513A, R454B, R1234ze
SG (I indicator): R22
SG (N indicator): R22, R134a,R404A, R407C, R507, R407A,R407F, R448A,R449A,R450A, R452A,R513A
For complete list of approved refrigerants, go to http://products.danfoss.com/all-products/
For the application use with R744 as part of a secondary loop or cascade system should refer to the
datasheet for more attentions.

Media temperature: Tmin. : -50 °C / -58 °F Max. working Pressure PS / MWP: SGP: 52 bar / 754 psig
Tmax. : +80 °C / +175 °F SG: 35 bar / 508 psig

Green Yellow
Grün Gelb
Vert Jaune

Danfoss
14-210
Verde Amarillo
Verde Giallo
綠色 黄色
Verde Amarelo
зеленый желтый

Danfoss
14-125.12

Dry N2
Type W W
mm in. mm in. Max. 80 °C / 175 °F
SGP/SG flare 6 14 9
/16 16 5
/8 Min. 5% Ag
SGP/SG flare 10 19 3
/4 22 7
/8
SGP/SG flare 12 22 7
/8 24 15
/16
SGP/SG flare 16 27 11/16 27 11/16
SGP/SG flare 19 32 11/4 32 11/4

d>22 mm – 7/8 in.


14-47.15
Danfoss

14-50.15
Danfoss

SGP/SG socket max. torque


100 Nm / 74 ft-lbs
14-67.15
Danfoss

Max. torque With O-ring max. torque


Size Nm ft-lbs 50 Nm / 37 ft-lbs
1
/4 in / 6 mm 20 15
3
/8 in / 10 mm 30 22 Hex 27 mm / 11/16 in
1
/2 in / 12 mm 60 44 Hex 32 mm / 11/4 in
5
/8 in / 16 mm 100 74
3
/4 in / 19 mm 200 148

­ DKRCC.PI.EK0.D8.02 | 1
© Danfoss | DSC (sw) | 2017.01
Technical leaflet Ball valves, type GBC

Introduction

Danfoss ball valves, type GBC, are manually


operated shut-off valves suitable for applications
where bi-directional flow is a requirement.
GBC valves are approved for applications in
liquid, suction, and hot gas lines in refrigeration
and air- conditioning systems.
GBC valves offer maximum tightness across the
seat and seal, with minimum pressure drop.
These ball valves give maximum flow in the fully
open position. They are designed for operation
within a broad temperature range and are
approved for use with any fluorinated refrigerant.
They may be used in applications using high
pressure refrigerants including R-410A.
GBC valves are equipped with a one-piece seal
cap to prevent tampering.

Features Slimline body – easier to install and service. Burst-proof spindle design.
¼ turn from fully open to fully closed. Valve seal of low friction, tight-sealing modified
PTFE Teflon®.
Rotation stops at fully open and fully closed
positions. Drilled and tapped for panel mounting.
Indicator on spindle top shows degree of opening.
Bi-flow – valve orientation is not an issue.
Precision laser welded construction.

Technical data Refrigerants CFC, HCFC, HFC


Temperature range –40 ➞ +300°F (–40 ➞ +150°C)
Max. working pressure (PS/MWP) 653 psig (45 bar)
Max. test pressure 943 psig (65 bar)

Approvals

*Safety and environmental requirements

0 USCOC.PK.000.C.22 © Danfoss Inc. 0-07 (USCO)


Technical leaflet Ball valves, type GBC

Ordering The product range consists of two valve types: sizes from 1/4 in. to 31/8 in. (6 mm to 54 mm).
one with and one without access port. Both All valves have holes for panel mounting.
versions can be supplied in inch or millimeter

GBC without access port


Solder ODF connection Cv value *)
Type [in.] Code no. [gal/min]
GBC 6s 1/4 009G7020 9
GBC 10s 3/8 009G7021 25
GBC without access port 1/2 009G7022
GBC 12s 47
GBC 16s 5/8 009G7023 62
GBC 18s 3/4 009G7024 90
GBC 22s 7/8 009G7025 124
GBC 28s 11/8 009G7026 229
GBC 35s 13/8 009G7027 356
GBC 42s 15/8 009G7028 533
GBC 54s 21/8 009G7029 990
Restricted flow
GBC 67s 25/8 009G7036 1082
GBC 79s 31/8 009G7037 980

GBC without access port


Solder ODF connection Cv value *)
Type [in.] Code no. [gal/min]
GBC 6s 1/4 009G7050 9
GBC 10s 3/8 009G7051 25
GBC with access port GBC 12s 1/2 009G7052 47
GBC 16s 5/8 009G7053 62
GBC 18s 3/4 009G7054 90
GBC 22s 7/8 009G7055 124
GBC 28s 11/8 009G7056 229
GBC 35s 13/8 009G7057 356
GBC 42s 15/8 009G7058 533
GBC 54s 21/8 009G7059 990
Restricted flow
GBC 67s 25/8 009G7066 1082
GBC 79s 31/8 009G7067 980

*) CFD calculated values (Computational Fluid Dynamics)

© Danfoss Inc. 01-07 (USCO) USCOC.PK.000.C1.22 105


Technical leaflet Ball valves, type GBC

Dimensions and weights

Weight
Type Conn [in.] H [in.] H1 [in.] L [in.] L1 [in.] L2 [in.] L3 [in.] L4 [in.] L5 [in.] M [in.] D [in.] d [in.]
(lbs)
GBC-6S 1/4’’ 1.96 0.59 5.43 0.27 2.91 2.83 0.87 1.22 M4 x 0.027 0.55 0.06 0.44
GBC-10S 3/8” 1.96 0.59 5.43 0.31 2.91 2.83 0.87 1.22 M4 x 0.027 0.55 0.06 0.44
GBC-12S 1/2” 1.96 0.59 6.30 0.39 3.35 3.27 0.87 1.22 M4 x 0.027 0.55 0.06 0.44
GBC-16S 5/8” 1.96 0.59 6.30 0.47 3.35 3.27 0.87 1.22 M4 x 0.027 0.55 0.06 0.44
GBC-18S 3/4” 2.44 0.75 7.28 0.55 3.90 3.78 1.18 1.46 M4 x 0.027 0.75 0.06 0.88
GBC-22S 7/8” 2.44 0.75 7.28 0.70 3.90 3.78 1.18 1.46 M4 x 0.027 0.75 0.06 0.88
GBC-28S 11/8” 2.95 0.98 8.19 0.79 4.41 4.25 1.50 1.73 M4 x 0.027 1.00 0.06 1.98
GBC-35S 13/8” 3.46 1.18 9.88 0.98 5.35 5.12 1.89 1.73 M4 x 0.39 1.26 0.06 3.09
GBC-42S 15/8” 4.01 1.38 11.06 1.14 5.94 5.71 2.17 2.20 M4 x 0.39 1.50 0.06 4.85
GBC-54S 21/8” 4.84 1.81 12.00 1.34 6.67 6.18 2.91 2.20 M4 x 0.39 1.97 0.06 9.26
GBC-67S 25/8” 4.84 1.81 12.00 1.46 6.67 6.18 2.91 2.20 M4 x 0.39 1.97 0.06 9.70
GBC-79S 31/8” 4.84 1.81 12.00 1.65 6.67 6.18 2.91 2.20 M4 x 0.39 1.97 0.06 9.92

106 USCOC.PK.000.C1.22 © Danfoss Inc. 01-07 (USCO)


5. FAN
BSB Series
SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

Kruger Ventilation Industries certifies that the BSB


series shown herein is licensed to bear the AMCA
Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
publication 211 and AMCA publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.
BSB ‘UII’

BSB 315-400 ‘UII’


B N
G X
R

t1

z
C

S
D

Y
Ød-g6
A

V1
V2

V
w
=

E
= F = uxs
J Q
P H M
L

Model A B C D E F G H J L M N P Q R S V V1 V2 X Y t t1 w z ∅d uxs

315 578 518 340 404 223 330 236 480 253 705 60 279 38 274 3 460 315 356 395 251 432 8 7 40 28 25 13x18

355 654 578 383 452 247 368 260 548 287 765 60 303 30 300 6 508 355 395 435 275 480 8 7 40 33 30 13x18

400 736 650 432 506 274 402 290 612 314 812 60 330 38 320 5 562 400 438 480 302 534 8 7 40 33 30 13x18
All Dimensions in mm.

BSB 450-1000 ‘UII’


B N
G X
R

t
=

t1

z
C

S
Y
D

Ød-g6
F1
A

V1
V2

w
F
=

uxs E
= F F1 F =
P J Q
H M
L

Model A B C D E F F1 G H J L M N P Q R S V V1 V2 X Y t t1 w z ∅d uxs

450 827 726 486 568 308 200 111 322 681 348 876 70 364 45 340 5 624 450 487 530 336 596 10 8 50 38 35 13x18

500 918 800 538 638 345 245 120 352 750 385 933 70 401 50 360 5 694 500 541 580 373 666 10 8 50 38 35 13x18

560 1030 892 603 714 383 280 125 390 844 433 1018 90 439 48 378 7 770 560 605 646 411 742 12 8 70 43 40 13x18

630 1157 998 679 800 433 328 110 434 945 483 1090 90 489 53 400 6 856 630 674 716 461 828 12 8 70 43 40 13x18

710 1302 1120 765 898 479 360 150 484 1057 529 1176 110 535 63 420 7 954 710 751 796 507 926 14 9 90 53.5 50 17x22

800 1468 1254 862 1006 533 405 171 540 1180 583 1248 110 589 74 440 7 1062 800 837 886 561 1034 14 9 90 53.5 50 17x22

900 1648 1408 971 1130 595 455 189 604 1319 645 1360 110 651 89 490 7 1186 900 934 986 623 1158 18 11 90 64 60 17x22

1000 1810 1540 1066 1266 663 500 200 656 1450 713 1448 110 719 90 510 9 1322 1000 1043 1086 691 1294 18 11 90 64 60 17x22
All Dimensions in mm.

28
TDA-F Series
SMOKESPILL AXIAL FAN
SMOKESPILL AXIAL FLOW FAN

Application

TDA-F
Applicable for smoke exhaust system in Shopping malls, hospitals, commercial
buildings, Airport etc.

Construction
SERIES Double flanged casing is manufactured in mild steel or galvanised steel sheet.
Fan incorporate with a high efficiency axial impeller with manually adjustable
pitch blades of pressure-casted Aluminium.

Finish
Painting or galvanised after manufacture are normal finishes on all parts.

Motors
High temperature resistance Class ‘H’ motor, compliance to BS7346 Part2 1990,
Class B, C and D performance.
Standard motor up to 2.2kW are usually supplied on DOL starting, motor 3.0kW
and above are star/delta starting.

Airflow Direction
Air flowing from impeller to motor are fitted as standard. Air flowing from motor
to impeller can be supplied on request.

IMPORTANT NOTE :
Motor should be selected to handle air at ambient temperature based on specified air volume and static pressure.
This is to allow periodic testing of the fan and in case of a fire, the smoke temperature is lower than specified.

Dimension

D
N? x


All Dimension in mm.

Weight Max. Motor* Weight Max. Motor*


Model A B C D N° ∅ Model A B C D N° ∅
( kg ) Frame Size ( kg ) Frame Size

315 315 355 395 355 8 10 8 D71 800 800 845 900 560 18 12 49 D132M
355 355 395 435 355 8 10 10 D80 900 900 945 1000 630 18 12 66 D160M
400 400 440 480 355 12 10 11 D90S 1000 1000 1050 1100 630 24 12 73 D160M
450 450 490 530 400 12 10 14 D90L 1120 1120 1185 1250 900 24 12 135 D225M
500 500 540 580 500 12 10 18 D90L 1250 1250 1315 1380 1000 24 12 170 D250M
560 560 605 660 500 12 10 22 D112M 1400 1400 1465 1530 1100 32 14 220 D250M
630 630 675 730 500 12 10 24 D112M 1600 1600 1663 1730 1250 32 14 275 D250M
710 710 755 810 500 18 12 40 D112M

• Motor frame size beyond this range, please consult KRUGER for details
• Weight without motor and impeller.
CCE Series
IN-LINE FAN - DIRECT DRIVEN
In-Line Direct Driven Fan – CCE Series

• Cabinet is manufactured in
galvanized sheet steel. Dimension
• Incorporates a direct driven,
DIDW forward curved centrifugal
fan.
• Removable access panel on both
sides for easy access to fan and motor.
• Flanged inlet and outlet for easy
ductwork connection.
• Operating temperature -40°C to +40°C

Optional Features:
• Internal Insulation.
• Filter with throwaway media.
• Different discharge orientation.

Weight
Model A B C D E F G H J K
(kg)
CCE 140 403 316 268 198 111 210 160 441 25 233 11
Kruvent Industries (M) Sdn Bhd certifies
that the CCE series shown herein CCE 160 453 356 308 204 204 230 270 490 25 265 16
is licensed to bear the AMCA Seal. CCE 7-7 442 401 392 263 232 240 344 491 25 340 18
The ratings shown are based on tests and
procedures performed in accordance with CCE 8-8 502 451 442 291 260 291 384 549 25 379 21
AMCA Publication 211 and AMCA Publication CCE 9-7T 572 401 393 236 266 348 322 621 25 340 24
311 and comply with the requirements of
the AMCA Certied Ratings Program. CCE 9-7 573 451 442 236 266 348 382 619 25 378 27
CCE 9-9T 572 401 393 302 266 348 322 621 25 340 25
CCE 9-9 573 451 442 302 266 348 382 619 25 378 27
CCE 10-8 652 561 502 269 293 410 462 699 25 431 33
CCE 10-10 652 561 502 335 293 410 462 699 25 431 35
CCE 12-9 743 631 573 313 345 510 547 790 25 526 42
CCE 12-12 743 631 573 399 345 510 547 790 25 526 44
All dimension in mm.

Technical Data
Lp (A) at
Maximum Motor Maximum
Max Q Motor Voltage Capacitor Insulation 3m free Speed
Model Input Power Phase Hz Current
(m3/ h) Protection (V) (μF/ V) Class discharge (RPM)
(W) (A)
(dB (A))

CCE 140 4P-1 1SY 641 112 IP20 1 50 0.6 220 4.0/450 F 61 1450

CCE 160 4P-1 1SY 914 148 IP20 1 50 0.7 220 4.0/450 F 52 1400

CCE 7-7 4P-1 1SY 1577 255 IP20 1 50 1.1 220 7.5/450 F 52 1300

CCE 8-8 4P-1 1SY 1613 328 IP20 1 50 1.4 220 7.5/450 F 50 1300

CCE 9-7T 4P-1 3SY 1879 560/500/430 IP20 1 50 2.6/2.3/2.1 220 7.5/450 F 51 1200/1150/1100

CCE 9-7 4P-1 3SY 2084 590/500/430 IP20 1 50 2.7/2.5/2.0 220 7.5/450 F 47 1200/1150/1100

CCE 9-9T 4P-1 3SY 2426 780/520/360 IP20 1 50 3.5/2.5/1.8 220 12.5/450 F 56 1300/1100/800

CCE 9-9 4P-1 3SY 2574 800/520/360 IP20 1 50 3.6/2.4/1.7 220 12.5/450 F 51 1300/1100/800

CCE 10-8 4P-1 3SY 3639 1370/1120/940 IP20 1 50 6.3/5.2/4.5 220 16.0/450 F 59 1300/1250/1150

CCE 10-10 4P-1 3SY 3857 1420/1100/950 IP20 1 50 6.6/5.2/4.6 220 16.0/450 F 59 1300/1250/1150

CCE 12-9 6P-1 3SY 4547 1150/700/450 IP20 1 50 5.8/3.6/2.5 220 12.5/450 F 59 940/820/620

CCE 12-12 6P-1 3SY 5200 1220/700/450 IP20 1 50 6.2/3.7/2.5 220 12.5/450 F 62 940/820/620

- Values shown are for inlet Lwi(A) sound power levels for installation type D – Ducted inlet, Ducted outlet. The A-weighted sound ratings shown have been calculated per AMCA International Standard 301.
Ratings include the effects of duct end correction.
- Performance certified is for installation type D – Ducted inlet, Ducted outlet.
- Performance ratings do not include the effects of appurtenances (accessories).
- Speed (RPM) shown is nominal. Performance is based on actual speed of test.
- Lp(A) at 3m free discharge dB(A) levels are not licensed by AMCA International.
MTD Series
MIXED FLOW IN-LINE DUCT FAN
Mixed Flow In-Line Duct Fan – MTD Series

Mixed Flow in-line Duct Fan-MTD series are


specifically designed for direct connection in- Dimension
line with industry standard diameter circular
ducting.
MTD 100/1
It includes the combination of a powerful motor
factory matched to a mixed flow impeller.
151
The combination enables the MTD Series fan Ø4.5
82

to deliver high airflow performances with


minimum noise generation against high static

95.5
pressures typically found in ducted ventilation

51.5
34

95
systems.
MTD models are manufactured in tough
reinforced plastic, except models 100, 250 & 28 47.5 28 Ø 97
315 in steel casing and finished in tough epoxy- 232 Ø 137.5
polyester paint coating.
1.4 kg
Impeller blades moulded in tough ABS plastic,
except models 250 & 315 constructed from
pressed galvanised sheet steel.
Easy installation or maintenance with support
MTD 100/2 - 315
brackets which allow the motor and impeller
assembly to be fitted or removed without
J
dismantling the adjacent ducting.
Ø5.5 E
MTD Series fans are fitted with direct
connection two speed motors as standard with
thermal over load protection. All motors are

C
suitable for speed control regulation using
H

F
electronic or auto-transformer.
Max. operating temperature +40 ºC.
G ØD

Kruger Ventilation Industries Pte Ltd certifies that A ØB


the MTD series shown herein is licensed to bear
the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
with AMCA publication 211 and AMCA publication
311 and comply with the requirements of the
AMCA Certified Ratings Program. Models MTD
100/2-6 and MTD 125-6 are not licensed by AMCA
International.

Model A !B C !D E F G H J Kg

MTD 100/2 303 176 115 97 100 90 80 60 188 2.0

MTD 100/2-6 303 176 115 97 100 90 80 60 188 2.0

MTD 125 258 176 115 123 100 90 80 60 188 2.0

MTD 125-6 258 176 115 123 100 90 80 60 188 2.0

MTD 160 275 200 127 157 112 130 80 60 212 4.9

MTD 200 302 217 141 198 124 140 100 94 232.5 4.9

MTD 250 386 272 192 248 155 168 145 140 291 9.4

MTD 315 450 336 224 312 188 210 182 178 356 14.0
          All dimensions in mm.
Technical Data

Technical Data
Max Q Power Motor N° Max Insulation dB (A)
Model Phase Hz RPM
m3/h W Protection Pole Amp Class at 3m
148 / 125 33 / 20 IP44 1 2 50 0.25 / 0.15 B 58 / 56 2400 / 2150
MTD 100/1
145 / 85 31 / 21 IP44 1 2 60 0.18 / 0.13 B 45 / 37 2600 / 2100
MTD 100/2 225 / 150 44 / 27 IP44 1 2 50 0.26 / 0.18 B 50 / 44 2250 / 1800
MTD 100/2-6 250 / 185 55 / 37 IP44 1 2 60 0.26 / 0.18 B 46 / 42 2100 / 1400
MTD 125 335 / 250 49 / 33 IP44 1 2 50 0.37 / 0.26 B 52 / 42 2210 / 1900
MTD 125-6 360 / 300 55 / 39 IP44 1 2 60 0.37 / 0.26 B 51 / 40 2350 / 1900
520 / 390 55 / 48 IP44 1 2 50 0.30 / 0.22 B 48 / 41 2500 / 1850
MTD 160
558 / 335 68 / 52 IP44 1 2 60 0.31 / 0.23 B 49 / 38 2600 / 1600
840 / 690 115 / 94 IP44 1 2 50 0.55 / 0.41 B 55 / 48 2500 / 2150
MTD 200
860 / 615 170 / 109 IP44 1 2 60 0.68 / 0.51 B 54 / 46 2650 / 2000
970 / 905 130 / 101 IP44 1 2 50 0.65 / 0.39 B 54 / 51 2680 / 2400
MTD 250/1
1110/ 932 180 / 135 IP44 1 2 60 0.65 / 0.39 B 56 / 52 1450 / 1150
1270/1020 192 / 141 IP44 1 2 50 0.72 / 0.48 B 57 / 52 2420 / 1950
MTD 250/2
1295/ 885 257 / 162 IP44 1 2 60 1.00 / 0.67 B 57 / 50 2400 / 1650
1670/1315 283 / 175 IP44 1 2 50 1.30 / 0.90 B 59 / 53 2350 / 1700
MTD 315
1757/1188 352 / 186 IP44 1 2 60 1.50 / 1.00 B 60 / 52 2300 / 1550
- Speed (RPM) shown is nominal. Performance is based on actual speed of test.
- Performance ratings do not include the effects of appurtenances (accessories).
- dB(A) at 3m with ducted inlet and outlet at free field conditions. dB(A) is not licensed by AMCA International.
- MTD 100/2-6 and MTD 125-6 are not licensed by AMCA.

Accessories

Grilles Rectangular Duct


Mounted at the inlet or
Adapters
outlet of the fan, the grille The adapter enables the
prevents the entry of any MTD fan to be connected
foreign objects. to rectangular ducting

Back-Draft Shutter
Mounted at the outlet of
the MTD fan, the shutter
prevents the air re-
circulating when the fan
is not in use.
KCE-F Silver Series
CEILING MOUNT TYPE
CEILING MOUNT TYPE – KCE – F Silver Series
Features

A. Round spigot opening for easy


A B
connection to flexible hose.
B. Non return flap to prevent back-flow.
C. Body made of high impact ABS plastic. D
D. Balanced turbine with new wide angle, C
curved blade for quiet operation and F
high air volume. E
E. High static pressure design for ducted air
handling.
F. Capacitor operated motor with thermal
switch. G
G. Spring clip on front cover easily H
removable for cleaning.
H. Modern discreet designed cover in silver.

Performance

KCE 110X-F Silver 7


Ø9 160

120

242

Ø4.5 80

200
40
160

35
223

0
0 40 80 120 160 200 240
15

242

KCE 150X-F Silver


7 240
Ø9

200

160
303

120
Ø4.5
80
264
40
35
284

175

0
0 40 80 120 160 200 240 280
17

303

Technical Data
Model Max. Flow Max. Press. N° Power Hz dB RPM Weight
m3/h Pa Poles W kg
KCE 110X-F Silver 205 150 4 30 50 42 1250 1.3

KCE 150X-F Silver 260 200 4 30 50 43 1250 1.7

The company is always improving and developing its products, therefore the company reserves the right of making changes to the illustrated products.
Certified dimension can be provided upon request.

LEA024F.E0 KRUVENT INDUSTRIES (M) SDN BHD A member of

KVM0.1 - Lot 850, Jalan Subang 7, Taman Perindustrian Subang,


Edition 1 47500 Subang Jaya, Selangor DE.
- Tel 03-8074 3399 Fax 03-8074 3388
- www.krugerfan.com
6. GRILLI
\lair/ech \lair/ech
Company profile jjJFJnfiAt:il~~!] SQUARE CEILING AIR DIFFUSER
N
Sizen.!il.:l'~ N/~~fl'~(mm) F/imfl'~(mm) H/}]i:(mm)
VAIRTECH VENTILATION CO. , LTD. Is a member of XUXING AIRCONDITIONING EQUIPMENT FACTORY 150 150x150 275x275 45
which was established in 2001 in Foshan. Now, VAIRTECH is one of leading brand & manufacture of air diffusion
225 225x225 350x350 45
products in China.
300 300x300 425x425 45
With advantaged technology and strict quality control , Vairtech staff is devoting in designing & supplying a wide SD-A1 375 375x375 500x500 45
range of air diffuser, air grille , air damper, air vent, air register, air filter, access door, flexible duct, aluminum foil tape aluminum, white Ral9016/9010 450 450x450 575x575 45
and other HVAC accessories. ~g~~. Pi~s@. 475 475x475 600x600 45

Now, Our products are well sell to more than 25 countries with praise for the great structures , various style, nice ap-
Sizen.!il.:l'~ N/~~fl'~(mm) F/imfl'~(mm) H/}]i:(mm)
pearance and high quality.
150 150x150 295x295 50
"Customer first, Quality first"-we are sincerely welcome you to contact us for business. 225 225x225 370x370 50
300 300x300 445x445 50
SD-A2 X structure
19t LLrrtH=t~imJXl i~fi1HI.H~~, ~~IJ ElaiiT-2001 if-a{] if~ 00 ~if- ( i!fi~) 1HN 0~ ~IJif~/~~JXl~!l.IDic1tf I~ l~mlJJX: SD-A3 rod structure 375 375x375 520x520 55
a{], ~~~[I$:!k::2iml*~illlfi~: ~?JH8~~, 1'l51HfXJ~IJABS~~fXIJXlD; iml:Pil~~IJ~JJXH~; l8~~~1J=Ei ~ t&~f~~o aluminum, white Ral9016/901 0 450 450x450 595x595 50
; ~~M$~~ii1il:f.H o II.~, UiJ~.R~i1100001¥1J*. 1'±19twifiia~IJ$Ll.J,H~±1:l~::*:~a{]~r$f8J, o jg~~. Pi~s@.

fi~F~m*~•. ~~~~. #M~~. ~;~a. ~~*~· •m~oo~~#womm~. $*. m~~. Sizen.!il.:l'~ N/~~fl'~(mm) F/imfl'~(mm) H/}]i:(mm)
i-*
~~ i#l ~ 20 ~-t 00 ~t r ~ ~ ; ~ ffl P~IJ ~W a{] ~fi!f o
150 150x150 295x295 51
225 225x225 370x370 51
300 300x300 445x445 51
SD-A4 375 375x375 520x520 51
aluminum, white Ral9016/901 0
~g~~. Pi~s@. 450 450x450 595x595 51

Sizen.!il.:l'~ N/~~fl'~(mm) F/imfl'~(mm) H/}]i:(mm)


I s:s I

L)/A".~ _ ·.- .fi


150 150x150 595x595 55
225 225x225 595x595 55
300 300x300 595x595 55
SD-A5
aluminum, white Ral9016/901 0 375 375x375 595x595 55
~g~~. Pi~s@. 425 425x425 595x595 55

595

Sizen.!il.:l'~ N/~~fl'~(mm) F/imfl'~(mm) H/}]i:(mm)

300 300x300 595x595 55


SD-A7 375 375x375 595x595 55
aluminum, white Ral9016/901 0
~g~~. Pi~s@.
\lair/ech \lair/ech
ROUND CEILING AIR DIFFUSER OOJF~Itilitil~~lj 'fi!VtlxJ./~ ant ADJUSTABLE DEFLECTION AIR GRILLE
Sizen.!i/.1~ N/~~ll'~(mm) F/imll'~(mm) H/}]i:(mm)
100 98 250 65
150 148 300 65
DDG-A2
F=N+SS
200 198 350 65 material: aluminum
230 228 380 65
N standard color: white Ral9016/901 0
blades are adjustable
250 248 400 65 customerized size upon request
300 298 450 65 Ut
350 348 500 65
380 378 530 65
RD-A1 400 398 550 65
aluminum, white Ral9016/901 0
450 448 600 135
~g~~, 11!~13@. 500 498 650 185
550 548 700 200
DDG-P
material: PVC
standard color: white
Sizen.!i/.1~ N/~~ll'~(mm) F/imll'~(mm) H/}]i:(mm) blades are adjustable
customerized size upon request
150 148 260 50
200 198 310 50
250 248 360 50
RD-A2 300 298 410 50
aluminum, white Ral9016/901 0 350 348 460 50
SDG-A1
material: aluminum
standard color: white Ral9016/901 0
I blades are adjustable
customerized size upon request
Sizen.!i/.1~ N/~~ll'~(mm) F/imll'~(mm) H/}]i:(mm)

150 148 260 65


! ! ! A ! ! ! ! A

200 198 310 65


250 248 360 65
300 298 410 65 F=N+SS SDG-A2
RD-A3 350 348 460 65 N material: aluminum
aluminum, white Ral9016/901 0 standard color: white Ral9016/901 0
blades are adjustable
~g~~~ 11!~13@., mm~1iiil
• • • • • • • t..J customerized size upon request

ADJUSTABLE DEFLECTION AIR GRILLE 'fi!Vtl=ftantlfiJXl~~lj

DDG-A1 F=N+4 SDG-P


material: aluminum material: PVC
standard color: white Ral9016/901 0 standard color: white
blades are adjustable blades are adjustable
customerized size upon request customerized size upon request

E
\lair/ech \lair/ech
RETURN GRILLE @/Xlal1t~9Y @/Xlal1t~9Y RETURN GRILLE
SG-FB: without metal screen ;if'-;;~~JXXJ
SG-FBN: clw metal screen -;;~~JXXJ r-------- liP ~ SG-P
material : aluminum "1'
standard color: white Ral9016 I 9010 material: PVC
standard size: 150x150 200x200 , 250x250 , standard color: white
300x300, 350x350 (mm) blades in 45 degree
customerized size upon request customerized size upon request

M*-4: fgg.~ tff-;tgffi-@.: 8@.


fi-;tR "'1: 150x150 200x200, 250x250 ,
300x300, 350x350 (mm) ,........,
R-t~tl.~iliiJ

SG-FA
material: aluminum
standard color: white Ral9016 I 9010 SG-PHF
blades in 45 degree material: PVC
customerized size upon request
- standard color: white
door-hinged design for easy remaintance
clw nylon air filter
- customerized size upon request

SG-FC
material: aluminum
standard color: white Ral9016 I 9010
curve designed blades
customerized size upon request
ii/1~9Y LINEAR SLOT DIFFUSER

F=N+35 LS-A
SG-L material: aluminum
material: aluminum standard color: white Ral9016 I 9010
standard color: white Ral9016 I 9010 25mm slot
customerized size upon request 1, 2, 3, 4, 5, 6, 7, 8 slots for option
round louver: SG-LR = customerized length upon request
0100 , 125, 150, 200, 250mm

t--n!J. : f8 g.~ ti- ;t gyj @_ : s @_


R-t~~:I.~iliiJ
WlJJf~@JJXls~t: SG-LR
*.W.~: 100, 125, 150, 200, 250mm

LS-B
SG-HF F=N+35 material: aluminum

I material: aluminum
standard color: white Ral9016 I 9010
door-hinged design for easy remaintance
standard color: white Ral9016 I 9010
19mm slot
1, 2, 3, 4, 5, 6, 7, 8 slots for option
clw nylon air filter customerized length upon request
customerized size upon request =
\lair/ech \lair/ech
LINEAR BAR GRILLE f!JfjJXlCJ~9Y fi!'aJXlCJ~9Y EGGCRATE GRILLE

LG-AHO EG-F
F=N+38 F-N+SS
-
N material: aluminum material: aluminum
standard color: white Ral9016 I 9010 N standard color: white Ral9016 I 9010
- -------------------- 0 degree linear blades 12.7x12.7mm core, 90 degree core
customerized size upon request customerized size upon request
""
IIII .6 HHH H HK HH HH
F. F.

EG-H
LG-A30
material: aluminum
material: aluminum + standard color: white Ral9016 I 9010
standard color: white Ral9016 I 9010 12.7x12.7mm, 90 degree core
30 degree linear blades hinged design for easy remaintance
customerized size upon request customerized size upon request

EG-AU
LG-PO material: aluminum
material: PVC standard color: white Ral9016 I 9010
standard color: white 12.7x12.7mm, 90 degree core
0 degree linear blades hinged design clw removable G3 filter
customerized size upon request customerized size upon request

EG-C45
LG-P30 material: aluminum
white Ral9016 I 9010 I mill finished
...--- material: PVC
12.7x12.7mm,45 degree core
standard color: white
;; ~
iijiiiiiO" ~
30 degree linear blades
customerized size upon request 777777777777777777777
standard size: 600x600, 1200x600,
1200x1200 (mm)

l
= M~:W~~ ~*R@: S@. M~
12.7x12.7mmB~JJX45Jljfj B~~f~ ~
tff-;ftR ""1: 600x600 , 1200x600,
1200x1200 (mm)

EG-C
material: aluminum

1II
0; ; :2.1L I I I I I I I I I I I I I I I
white Ral9016 I 9010 I mill finished
12.7x12.7, 15x15, 9x9mm for option
90 degree core
standard size: 600x600, 1200x600,

M~:W~~ ~*R@:
1200x1200 (mm)
S@. M~
t~T-:*: 11' i=iJm12.7x12.7, 15x15, 9x9mm
90Jl~
LG-AC [!:!]5Jil LG-AV c:J 5Jil LG-AS ~7f~ fi-;ftR ""1: 600x600 , 1200x600,
1200x1200 (mm)
\lair/ech \lair/ech
LINEAR BAR GRILLE f!JfjJXlCJ~9Y fi!'aJXlCJ~9Y EGGCRATE GRILLE

LG-AHO EG-F
F=N+38 F-N+SS
-
N material: aluminum material: aluminum
standard color: white Ral9016 I 9010 N standard color: white Ral9016 I 9010
- -------------------- 0 degree linear blades 12.7x12.7mm core, 90 degree core
customerized size upon request customerized size upon request
""
IIII .6 HHH H HK HH HH
F. F.

EG-H
LG-A30
material: aluminum
material: aluminum + standard color: white Ral9016 I 9010
standard color: white Ral9016 I 9010 12.7x12.7mm, 90 degree core
30 degree linear blades hinged design for easy remaintance
customerized size upon request customerized size upon request

EG-AU
LG-PO material: aluminum
material: PVC standard color: white Ral9016 I 9010
standard color: white 12.7x12.7mm, 90 degree core
0 degree linear blades hinged design clw removable G3 filter
customerized size upon request customerized size upon request

EG-C45
LG-P30 material: aluminum
white Ral9016 I 9010 I mill finished
...--- material: PVC
12.7x12.7mm,45 degree core
standard color: white
;; ~
iijiiiiiO" ~
30 degree linear blades
customerized size upon request 777777777777777777777
standard size: 600x600, 1200x600,
1200x1200 (mm)

l
= M~:W~~ ~*R@: S@. M~
12.7x12.7mmB~JJX45Jljfj B~~f~ ~
tff-;ftR ""1: 600x600 , 1200x600,
1200x1200 (mm)

EG-C
material: aluminum

1II
0; ; :2.1L I I I I I I I I I I I I I I I
white Ral9016 I 9010 I mill finished
12.7x12.7, 15x15, 9x9mm for option
90 degree core
standard size: 600x600, 1200x600,

M~:W~~ ~*R@:
1200x1200 (mm)
S@. M~
t~T-:*: 11' i=iJm12.7x12.7, 15x15, 9x9mm
90Jl~
LG-AC [!:!]5Jil LG-AV c:J 5Jil LG-AS ~7f~ fi-;ftR ""1: 600x600 , 1200x600,
1200x1200 (mm)
\lair/ech \lair/ech
GRAVITY LOUVER @¥ant~9if {I/Iifi$k'lff~9if FLEXIBLE DUCT
GL-A
AFD-S: alu foil +PE f8t€i+~li SIZEnY.!m N/IJ{2(mm) Ll*il(m)
material: aluminum
standard color: white Ral9016 I 9010 AFD-D: alu foil +PE +alu foil
3" 075 10
air extraction and automatic close of duct spring wire: carbon steel from 0.9-1.3mm
when the air equipment is switched off temperature rating -30 to 150 oc 4" 0100 10
customerized size upon request fire resistant
standard length: 1Om 5" 0125 10
6" 0150 10
~"'-ji: 0.9-1 . 3mm~~IXI
I I 11=1./ffi.Ji 18: IBJ : -30 to 150 oc 8" 0200 10
*ff-;1t1fli: 10*
10" 0250 10
CFD 12" 0300 10
PVC combine flexible duct
WHEATHER-PROOF LOUVER JI/i7./<ant~9if constructure: PVC+PET +alu foil
temperature rating -30 to 150 oc
14" 0350 10
16" 0400 10
fire resistant
FL-A standard length: 1Om 18" 0450 10
material:aluminum Pvc~g.$xl[ 20" 0500 10
white Ral9016 I 9010; any size is available
~*~: PVC+~~~+f8t€i
M*-4: fgg.~ *;r-aUY!@: S@ I 11=1./ffi.Ji 18: IBJ: -30 to 150 oc
R "1 ~H.~.O:E: iM *ff-;it1fli: 10*
f_~ 7AR: round louv~rl~Hf~M"7.1<sllt SIZEnY.!m N/IJ~£(mm) Ll*il(m)
~~d~R "1 /standard s1ze: 2.5" 060 3
0100, 125, 150, 200, 250mm SFD 3" 075 3
semi-rigid aluminum flexible duct
!temperature rating -70 to 220 oc 4" 0102 3
fire resistant 5" 0127 3
standard length : 3m 6" 0152 3

DOOR GRILLE j]JX(,CJ~9if ~81&:~.)(1[


7"
8"
0165
0203
3
3
I 11=1./ffi.Ji 18: IBJ: -70 to 220 °(
DG-A
~i-;1t1fli: 3* 10" 0254 3
12" 0305 3
material:aluminum
standard color: anodized silver IFD-S&D
double layer blades
air transfer on doors or walls single/double layer alu foil duct
+ fiberglass+alu foil jacket Duct Spring wire!~"'-ji(mm)
any customerized size is available
temperature rating -30 to 150 oc Diameter
;1:.9.!1~ Space/ (8] '~
Diameter
M:¥!11ii£
fire resistant
standard length: 1Om 4" 25 1.0
5" 25 1.0
6" 30 1.0
7" 30 1.1
8" 35 1.1
IFD-PD
ltem/tlffl-5 alu foil/f85a Thickness/~!~ 10" 40 1.2
backing : aluminum foil double layer alu foil duct
adhesive: water-based acrylic adhesive AT503 16um 51um + polyester +alu foil jacket 12" 40 1.2
linear: white silicone release paper AT602 23um 61um temperature rating -30 to 150 oc 14" 40 1.2
fire resistance fire resistant
customerized size upon request AT702 30um 68um standard length: 1Om 16" 40 1.3
AT802 35um 73um
18" 40 1.3
AT902 38um 88um
20" 40 1.3
\lair/ech \lair/ech
ACCESS PANNEL ~f~CJ~~lj ~f~CJ~~lj ACCESS PANNEL

AD-H r---
SIZE/#1.~ N/~HB(mm) F/JmltB(mm ) H/~(mm)
material : aluminum '" 200 200x200 250x250 60
standard color: white Ral9016 I 9010
door-hinged design
customerized size upon request
I 250 250x250 300x300 60
key lock or touch lock 300 300x300 350x350 60
I 350 350x350 400x400 60
;fvt*-~: f8 ~~ *ff-;'fU9!@ : 13@
R ""1 jiJ ~~ ;;E iM 400 400x400 450x450 60
450 450x450 500x500 60

,,,,,, A D-R 500 500x500 550x550 60


zw ,, material : aluminum 550 550x550 600x600 60
a.
0
'i
llo standard color: white Ral9016 I 9010
''"' 600 600x600 650x650 60
~*
¢1 inner core is totally removable
J:
rn ,,,,''"' customerized size upon request
:::>
a. ,,,, AD-FC: without gypsum board
,,,, aluminum , white Ral9016 I 9010
:if''M=li. t&
AD-FCG: c/w gypsum board false ceiling design, touch lock
'M=li. t& l8~~. ~i#<13@, -;;~JH!li

AD-HG i/l11t!illtl1¥/W~9Y AIR DAMPER & DAMPER HARDWARE


frame: aluminum door:steel
standard color: white Ral9016 I 9010
door-hinged design
customerized size upon request
VCD-A
material:aluminum
standard color: anodized silver
blades are adjustable
customerized size upon request

+ +
AD-GC
material: steel
standard color: white Ral9016 I 9010
tf~ H

door-hinged design I
customerized size upon request
I VCD-G
material: galvanized sheet
standard color: original silver

\
blades are adjustable
+ +
1-- customerized size upon request

AD-GD
N/~HB(mm ) F/JmltB(mm) H/~(mm)
I
245x85 295x135 45
245x155 295x205 45
380x245 430x295 45
505x375 555x425 45
655x505 705x555 45
H-A H-AR H-C SET BR-S BJ-S RR-G
MOTORED FIRE DAMPER(NORMAL CLOSED)
NECK SIZE : any size available
TYPE: "TDC= transverse duct connection"Joint Type
Or welding
MATERIAL: GALVANIZED STEEL WITH 30MM BORDER WIDTH OF
ANTI-FLANGE
THICKNESS::FRAME:2.0MM;BLADE:1.5MM;
280 DEGREE FUSIBLE ALLOY;
COLOR:ZINC COAT
ACTUATOR:BELIMO BF 230-T(SPRING RETURN TYPE, AC230;60HZ )

You might also like