Professional Documents
Culture Documents
PVI 10.0 Datasheet PDF
PVI 10.0 Datasheet PDF
Disconnect
PV DC + AC
Designed for commercial systems, the This inverter is feature rich, enabling Highlights:
PVI-10.0, isolated, three-phase inverter the desired design flexibility to master − − This isolated inverter is available in
is highly unique in its ability to control any design challenge. 208V, 480V and 600V outputs.
the performance of the PV panels, The input voltage range makes this − − It has an efficiency rating of up to
especially during periods of variable inverter suitable for installations with 97.3%.
weather conditions. reduced string size. − − The high-speed and precise MPPT
The PVI-10.0-I is built to endure harsh algorithm enables real-time power
The dual Multiple Power Point Tracker environmental conditions with its NEMA tracking and improved energy
(MPPT) maximizes energy production 4X rating. harvesting.
and increases design flexibility. The PVI-10.0-I is available with an − − The electrolyte-free power converter
This dual independent MPPT functionality optional fully-integrated DC combiner increases the life expectancy and
enables optimal energy harvesting from box equipped either with DC or AC and reliability.
two sub-arrays oriented at different DC disconnect switches and DC fuses.
azimuths, tilts and varying string lengths.
The wide input voltage range makes this
inverter suitable for installations with a
reduced string size.
The flat efficiency curves offer high
efficiency at all output levels ensuring
consistent and stable performance
across the entire input voltage and output
power range.
Additional highlights:
− − True three-phase bridge topology − − NEMA 4X outdoor enclosure for
for DC/AC output conversion use under any environmental
− − It features a night wake up button conditions
to access energy harvesting data − − Integrated combiner box equipped
and information when inverter is with a DC switch in compliance
sleeping with international standards
− − The dual independent MPPT (-S1,-S2)
allows optimal energy harvesting − − RS-485 communication interface
from two sub-arrays oriented in (for connection to laptop or
different azimuths and tilts datalogger)
PV DC + AC Disconne
ct
IN1.3(-)
IN2.1(+) MPPT 2 HF
(DC/DC) TRANSFORMER -S2 VERSION
+
IN2.2(+)
IN2.1(+)
+
+ IN2.3(+) IN2 IN2
IN2.2(+)
IN2
IN2.1(-)
IN2.1(-) - -
-
IN2.2(-)
IN2.2(-)
IN2.3(-) RS485
+ T/R
- T/R
STANDARD VERSION -S1 / -S2 VERSION
RTN
DC/DC DC/AC
DSP DSP REMOTE CONTROL
GROUND CONTR. CONTR.
FAULT +R
DETECTION
-R
µP ALARM
N.C
N.O
CONTROL CIRCUIT C
PVI-10-I-OUTD
98
97
96
Efficiency, %
95
220 Vdc
220 Vdc
94
362 Vdc
362 Vdc
93
416 Vdc
416 Vdc
92
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
% of Rated Output Power