Download as pdf
Download as pdf
You are on page 1of 13
National Accreditation Board for Testing and Calibration Laboratories {XX __ (AConstituent Board of Quality Council of India) NABL CERTIFICATE OF ACCREDITATION AUTOCAL SYSTEMS has been assessed and accredited in accordance with the standard ISO/TEC 17025:2005 "General Requirements for the Competence of Testing & Calibration Laboratories" for ts faclities at 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra inthe field of CALIBRATION Certificate Number CC-2614 (in eu of C-1346,C-1347,C-1348) Issue Date 10/03/2018 Valid Until 99/03/2020 This certificate remains valid for the Scope of Accreditation as specified in the annexure subject to continued satisfactory compliance to the above standard & the relevant requirements of NABL. {To see the scope of accreditation ofthis laboratory, you may also visit NABI. website www.nabl-inda.org) Signed for and on behalf of NABL Avijit Das ict Anil Relia Program Director Chief Executive Officer Laboratory Accreditation Standard Certificate Number | Guantity Weasured7 | Instrument Temperature | Simulation” (Temperature Indicator) | RTD | K Type Dheeraj Chawla Convenor National Accreditation Board for _ Testing and Calibration Laboratories (A Constituent Board of Quality Council of india) SCOPE OF ACCREDITATION Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra ISO/IEC 17025: 2005 CC-2614 (in iow of C-1346,c-1347 & C-1348) Page 4 of 12 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 “T RaiigelPteduenéy | “Calibration Capability (2) | ELECTRO-TECHNICAL CALIBRATION ising Zeal Z% lultitunction Calibrator By irect Method 33% to 0.32% | Calibrator By Direct 0.32% t0 0.24% | Method Hi Using Multifunction 0.6% t0 0.45% Calibrator with Current 0.45% to 0.33% Coil By Direct Method | 10,A to 900 A 3.31% to 1.96% y | ()200°C to. 400°C | 1.00 °C Using Massibus Unical 0 °C to 1250 °C [071°C 3001 M Calibrator 0 °C to 700 °C | 0.70 °C By Direct Method (150°C 10 400°C | 0.71 °C 100 °C to 1700 °C 1.90 °C 100 °C to 1700 °C |4.30.°C. | | Oe ‘Avijit Das Program Director y Laboratory Accreditation Standard National Accreditation Board for — Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) SCOPE OF ACCREDITATION Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra ISOMEC 17025: 2005 Certificate Number Validity Quantity Measured) | _ Instrument Resistance” 10 kA to 100 KO 100 kQ to 1 MO 1 MQ to 10 Ma 10 MQ to 100 Ma [i mivto tooo qo z +14 mA to 20 mA 20 mA to 100 mA 100 mA to 10. VAC Voitage” | + ‘AC Current” mA to 10 mA TAWOA i2otocka | 2kQ to 100 ka 100 kA to 1 MA Convenor (CO-2614 (in ew of 6-1340,6-1347 & 0.1548) 10.03.2018 to 09.03.2020 RangelFrequency Page 2 of 12 Last Amended on 16.03.2018 | *Cai A | Capability (#) Using Zeal Precision decade Resistance Box By Direct Method | 0.91% 10 0.58% | 0.20% 10 0.117% | 0.117% 10 0.117% 0.417% 10 0.117% 0.117% t0 0.117% 0.117% t0 0.117% 0.147% t0 0.117% | 0.117% to 0.964% ing 6 BNI Mieco 65°” ty Direct Method ising 6% DMM Meco 65> By Direct Method 10.50 % to 0.10% | 0.10% to 0.07% | 0.07% to 0.60% a Using 6 DMM Meco 65> 0.50 % to 0.10 % By Direct Method 0.10% to 0.07% | | 0.07% to 0.50% | | | Tsing 6 BU Wess BE) 0.46 % 10 0.16% By Direct Method | 10.16 % to 0.246 % | | EEE Re -ee feeeee eeeececec / 0.50% to O80% vig 6 Dis BaP 0.05% to 0.013% By Direct Method | 0.013 % t0 0.20% co Avijit Das Program Director Laboratory Accreditation Standard | Quantity Measured / _ Instrument badl Dheeraj Chawla Convenor | | p National Accreditation Board for Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) SCOPE OF ACCREDITATION Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra ISOMEC 17025: 2005 CC-2614 (In eu of €-1346,0-1347 & C-1348) Page Sof 12 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 | Using HV Probe 1 KVAC to 10 VAC | 7.555% to 6.310% | DMM By Direct Method JO KVAC to 20 KVAC | 5.310% 10 5.293% 2OKVAC to 40 KVAG | 5.293 % to 6.000 % ‘BO Hz | Using HV Probe With 1 RVAC 10 5 KVAC 555% 10 5.310% | DMM By Direct Method e ‘sec to 3600 Sec” Se ~~ Using Digital Timer ‘Autonics CT6S By ‘Comparison Method 1 Avijit Das Program Director Laboratory Accreditation Standard Certificate Number Validity Bt Instrument "Quantity Measured | RangeiFrequency | “Calibration Measurement] Remarks National Accreditation Board for _ Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) SCOPE OF ACCREDITATION Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra ISONEC 17025: 2005 CC-2614 (in teu of c-1346,0-1347 & C-1348) Page 4of12 10.03.2048 to 09.03.2020 Last Amended on 16.03.2018 | Capability (2) MECHANICAL CALIBRATION DIMENSION (BASIC MEASURING INSTRUMENT, GAUGE ETC.) | | Recker Gauge* | 4 | ¥ | & Parallelism® 5 iuge™ iain Plog /Wiath Gauge® ' ‘| | Brn Dheeraj Chawla Convenor Block Syrngiairciy | ~~} Using Electronic dial Comparator with Probe & slip Gauges Length Bar by | Upto 100 mm 100 mm to 300 mm Sa un 3.6 um 0.01 to. 0.7 mm | Using Electronic dial | Comparator with Probe & | slip Gauge by comparison jethod 309m “Using Electronic dial Comparator with Probe & slip Gauges by comparison Method Using Siraight tiandrat & Plunger Dial by direct Method | ip Gauge by | comparison Method ~~ Using Elecivnie iat | Comparator with Probe & slip Gauges by comparison i Method pis 166" in 400mm to 250mm | Upto 100 ‘mm — 400mm to 250 mm Vo ‘Avijit Das Program Director Laboratory Acce’ Cerificate Number Validity BL “Quantity Meas Leo: 0.02mm Height Gauge | Verniet/ Dial / | Electronic® LC: 0.01mm LC 0.01mm | Depth Gauge? | Vernier / Dial Electronic® LC -0.01mm Internal Micrometer* (Two Point) LC:-0.01 mm National Accreditation Board for Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) SCOPE OF ACCREDITATION Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra ion Standard ISO/IEC 17025: 2005 CC-2614 (in feu of €-1346,c-1347 & C-1348) Page 5 of 12 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 1 | RangelFrequency | *Calibration Measurement] Remarks | | Capability (#) | de | Using Caliper checker, | 010 1000 ‘mm | Length Bar & Slip Gauge | Set by direct Method | 010600. mm. | Using Caliper checker [Oto 1000 mm. &Surface Plate Length Bar & Surface Plate by direct Ising Depth Micrometer hecker by direct Method | Using Slip Gauge set length Bar by comparison Method | ee Up to. 300 mm, Using Slip Gauge set , Electronic Dial Comparator | with Probe by comparison Method Avijit Das Program Director on ex 3) National Accreditation Board for w / Testing and Calibration Laboratories ok (A Constituent Board of Quality Council of India) NABL SCOPE OF ACCREDITATION Laboratory Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra Accreditation Standard ISO/IEC 17025: 2005 Certificate Number (CC-2614 (in teu of C-1346,6-1347 &C-1348) Page 6 of 12 Validity 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 “| Quantity Measured / | RangeiFrequency | *Calibration Measurement] Remarks — [ Instrument | Capability (+) | ae | 142." [Two Pin Dial Cail LC 0.05 mm Up to 50 mm 23.91 um sing Slip Gauge set Electronic Dial Comparator with Probe by direct Method “13. | Depth Micrometer® | LC 0.01 mm 1010. 300 mm Using Depth Micrometer | Checker by direct Method 74. | Plunger Type Dial Gauge® LC 0.001 mm Up to 25 mm Using Dial Calibration | | Tester by direct Method Lever Type Dial iat Using Dial Calibration Tester by direct Method | Dial Bore Gauige™™ | (for Transmission | Mechanism) 47. | Dial Lc 0.001 mm Up to 260 mm | Using Gauge Block Set by | | comparison Method Up to 25 mm Using Gauge Block Set by comparison Method Dheeraj Chawla Avijit Das ‘Convenor Program Director National Accreditation Board for Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) SCOPE OF ACCREDITATION Laboratory Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra Accreditation Standard ISO/IEC 17025: 2005 Certificate Number CC-2614 (in teu of 6-1386,0-1347 46-1348) Page 7 of 12 Validity 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 s Quantity Measured 7] Range/Frequency ration Measurement] Remarks Instrument Capability (+) LC = 5min 0° -90° -0° Using Angle Gauge Block Set by comparison Method 19, ee Protector® | i 130." Combination | SeV/Angle Protector’ | 0-180" Using Angle Gauge Block Le. ‘Set by comparison Method 24. | Surface Piate™ mm X 2000mm | 2. 100 Using Spirit Level by direct ‘Method ressure Pneumatic | Oto i Bar 0.006 Bar Using Digital Pressure Dial and Digital | 1 to 30 Bar 0.1 Bar jauge & DMM. Pressure Gauge | 0 to 2000 Pa wurce :- Pressure Pressure Transmitier* ‘omparator by Comparison jethod based on DKD-R-6-1 | Pressure Hydraulic ising Digital Pressure Dial and Digital jauge & DMM Pressure Gauge source = Pressure Pressure Transmitter” jomperator by Comparison | lethod based on DKD-R-6 30 Vacca Gauge | (90.85 to 0 Bar ot 5 oo “Using Digital Pressure | Dial and Digital Gauge & DMM |PressureGauge | | source :- Pressure | Pressure Transmitter” -omparator by Comparison Bhenfoo | Dheeraj Chawla Convenor Program Director National Accreditation Board for _ Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) SCOPE OF ACCREDITATION Laboratory Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra Accreditation Standard ISO/IEC 17025: 2005 Certificate Number CC-2614 (in tow of ¢-1946,c-1947 £01348) Page B of 12 Validity 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 ‘T Quantity Measured 7 | RangeiFrequency | *Calibration Measurement Instrument | Capability (+) | ACOUSTICS | Sound Level wieter” | eh ig Sain Cava Caiator By Direct Method Weights of 1 mg to 200 g & Weight of £2 class | Balance of d : 0.01 mg up (img to 200 g) to 82.g and 0.1 mg upto | 2009 | Calibration Of M1 Class | Weights & Coarser as per | OIML R114 :2004 | Based on uncertainty and repeatability of Balance. | By Substitution Method | through ABBA Cycle “Using E2 Ciass Standard | ' ' | ge Dheeraj Chawla Avijit Das: Convenor Program Director National Accreditation Board for Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) SCOPE OF ACCREDITATION Laboratory Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra Accreditation Standard ISO/IEC 17025: 2005 Certificate Number CC-2614 (in ow of C-1346,c-1347 46-1348) Page 9 of 12 Validity 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 Quantity Measured 7” | RangelFrequency | ‘Calibration Measurement] Remarks Instrument _Capabity (2) | Weight of Fi class | Using F1 Class Standard 10 to 20 kg) Weights and balance of 30 | | kg and d: 0.1 g & Calibration OF M2 Class Weights & | | Coarser as per OIML R-111 | 2004 Based on uncertainty | and repeatability of Balance. | By Substitution Method | through ABBA Cycle V. [WEIGHING SCALE AND BALANCE Balance" [d:1mg | Using E2 Class Standard iatg Weights of 1 mg to 200 9 | & Calibration of class 2 | Weighing balances & | Coarser as per OIML R-76 | | Electeie Weighing | i | Standard Weights of 500g to 20 kg.& Calibration of class 3 Weighing balances & Coarser as per OIML R- 76 rn Dheeraj Chawia ‘Avijit Das Convenor Program Director ie) National Accreditation Board for _ Ly) Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) Nant SCOPE OF ACCREDITATION Laboratory Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra ISONEC 17025: 2005 CC-2614 (now of C-1346,6-1347 &-1348) Page 10 of 12 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 iy Measured 7 | RangelFrequency | i Mesrenient] Remarks | Capability (+) | Micro Pipette | Using Weighing Balance | with 4: 0.01 mg and 0.1 | mg & Distiled Water & £2 | Class Standard Weights & Calibration of Micro Pipette. Based on | Gravimetric Method as per ISO 8655-6 Glassware *~ lo5mi 00i7mi Using Weighing balance (Glass Pipettes, with 200 g & d:0.01/0.1 mg Burettes, Conical 102 & Distilled Water & E2 Flask, Beakers, Class Standard weights | Measuring Cylinder) | Calibration of Glassware Based on Gravimetric Method as per ISO 4787 | | | ‘Avijit Das Convenor Program Director ) National Accreditation Board for / Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) SCOPE OF ACCREDITATION Laboratory Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra Accreditation Standard ISO/IEC 17025: 2005 Certificate Number CC-2614 (in iow of C-1346,0-1347 86-1348) Page 14 of 12 Validity 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 aii” RangeiRvequsney | "Calibration Woacivement] Remarks | | Capability (2) | } A THERMAL CALIBRATION ‘TEMPERATURE RTDITC With & (30 °C to 50 °C Using Standard PRT , Without indicator, | §0 °C 10 250 °C R Type T/C With 6 % Temperature } 250 °C to 1100 °C DMM, Measuring Device Liquid Baths, Dry Well with Probe/ Data Baths & Dry Well Furnace. | | ogger Recorder! By Comparison Method | Temp.Transmitter* ()10 °C to 250" ~~ | Using Standard PRT, | 6 4 DMM & Liquid Bath | By Comparison Method | Glass Thermorneier® 0 °C to 250 °C ~~ Using Standard PRT, 6 % DMM & Liquid Bath | By Comparison Method Dial Thermometer® | with sensor of 1 50°C to 250 °C 0.63 °C | 6% DMM & Liquid Bath | Freezer, oven, | 250°C to1100°C | 243°C By single position Furnace, Bath, Dry calibration (At Measuring Block furnace” | | | Location in DUC) 1 / | Temperature indicator | (30% to 60°S P03 °S ~———"T Using Standard PRT | J ¥, oh Laut fe oo heeraj Chawla Avijit Das Convenor Program Director National Accreditation Board for Testing and Calibration Laboratories (A Constituent Board of Quality Council of India) SCOPE OF ACCREDITATION Laboratory Autocal Systems, 83/526, Sant Tukaram Nagar, Pimpri, Pune, Maharashtra Accreditation Standard ISO/IEC 17025: 2005 Certificate Number CC-2614 (in ou of C-1346,¢-1347 & C-1348) Page 12 of 12 Validity 10.03.2018 to 09.03.2020 Last Amended on 16.03.2018 Si.) Guantity tweasured’7 | Rangelfrequency | Calibration Measurement Instrument | | Capability (#) fs | Using Standard | | Chamber, i Sensors (Minimum Nine) | [sszasenk Room’ | with Data Logger By Muti position calibration ¥ Measurement Capal ‘expressed as an uncertainty (2) at a confidence probability of 95% Sonly in Permanent Laboratory “Only for Site Calibration *The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual environmental conditions and master equipment used. Program Director

You might also like