Locking Devices

Security Door Controls


1

Electric
Bolt Locks
Recommended for high security interior door and
cabinet applications where electromagnetic locks are
not required.

The SDC family of electric bolt locks include long life


solenoid driven direct throw mortise bolts, Spacesaver®
right angle bolts for narrow frames and door stiles
and surface mounted bolt locks for door and cabinet
applications. Compatible with virtually any access
control system, electromechanical bolt locks are
available in failsafe and failsecure modes.

As the inventor of numerous


electronic lock designs,
SDC founder Art Geringer
is credited with ushering in
the modern era of access
control hardware with his
development of the 90° throw
electric lock. Now commonly
used, this creation opened the potential of
electric locking capabilities and began the great
migration to electric locking systems.

122
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric
Locking
1090 / 1290 Spacesaver®

Bolt
Bolt Locks

Devices
Locks
The Spacesaver®, first
designed and patented
by SDC, is a fundamental
innovation in electric
locking technology
for access control
applications.

FEATURES INSTALLATION
STAINLESS STEEL BOLT
Greater security is provided by the 0.625” diameter
SDC Spacesaver®
solid stainless steel bolt. The bolt rotates freely, making
locks may be
attempts to tamper or cut extremely difficult.
mounted in the frame
header, side jamb or
SPECIFICATION GRADE SOLENOID
door lock stile.
All Spacesaver® lock solenoids are manufactured by SDC
to precision specifications. SDC solenoids are capable of
superior overall performance in both force and longevity,
providing years of service compared to commercial grade
The stainless steel bolt projects at right angles to the lock
solenoids.
mechanism, allowing installation of Spacesaver® locks, by means
of a simple cutout, in virtually any standard 1.75” frame, or in
CODE COMPLIANT
most door lock stiles. With the entire lock concealed, aesthetic
Classified in accordance with Uniform Building Code
acceptability is complete, security is greater and installation in
standard 7-2, “Fire Test for Door Assemblies”
old or new construction is fast, easy and economical.
FIELD ADJUSTABLE AUTO-RELOCK SWITCH
The automatic relock switch keeps the bolt retracted MODELS
while the door is open. The door depresses the ball 1091AI Failsafe 12/24VDC
switch assembly on closure, causing the bolt to project 1091AIWD Failsafe 12/24VDC,
automatically, locking the door. In addition, the ball with 8-1/2” x 1-1/2” x 1/8”
switch assembly is bidirectional, permitting the locks to faceplate, specifically for wood
be used on swinging and sliding doors. frames
1091ADLI Failsafe Deadlocking 12/24VDC
1091ADLWDI Failsafe Deadlocking 12/24VDC
with 8-1/2” x 1-1/2” x 1/8”
faceplate, specifically for wood
Fig. 1 Fig. 2 frames
1291AH Failsecure 12/24VDC
The auto relock assembly is field adjustable to
1291AHWD Failsecure 12/24VDC,
compensate for wide door gap. (See Figure 1 & 2 above)
with 9” x 1-1/2” x 1/8” faceplate,
specifically for wood frames

FIELD YEAR
12
5
POWER

24 W
EL
E

DATA
L
S

AR
RANT
Y

E C TA B

123
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric Bolt Locks

LOCK FUNCTION SPECIFICATIONS


1091A FAILSAFE 8”L x 1-1/2”W x 1/8”D
Face Plate
The 1091A is locked when energized. Recommended for safety (unless noted differently)
applications, it is intended that the door unlock automatically Strike 4”L x 1-1/2”W x 1/8”D
when power is interrupted by the access control, power failure
Frame Inner
or signal from a fire life safety system. 8”L x 1-1/2”W x 1-1/2”D
Dimension
• Bolt Throw 0.75” See figure 4 below
Requirements
The 1091ADL is equipped with a deadlocking mechanism
Bolt Material Solid Stainless Steel
that prevents the bolt from being tampered with and pried to
unlock. The 1091ADL has all the operational features of the Bolt Diameter 5/8”
1091A (above) and is recommended for failsafe applications
1091A/1091ADL: 3/4”
requiring a higher level of security. Bolt Throw
1291A: 5/8”
1291A FAILSECURE Mounting Tabs Two aluminum mounting tabs are
The 1291A is locked when de-energized and unlocked when provided for easy lock installation.
energized. Recommended for security applications only, See figure 3B below
it is intended that the door remains locked when power is Dual Voltage Coil 0.45 Amp @ 24VDC Continuous Duty
interrupted by a power failure. 0.9 Amp @ 12VDC Continuous Duty
• Bolt Throw 0.625”
Weight 1.45 lbs

Figure 3A, 3B, 3C, 3D: Typical Frame Header or Side Jamb Installation Figure 4: End View

3C. Connect
3A. Mortise cutout in wiring to lock.
tube for face plate
(fits flush with
surface of tube).
3B. 3D.
Position screws Slide lock
for attaching into position,
tabs, drill holes, attach to tabs.
attach tabs.

PRODUCT SKU SAMPLE: 1091AI V D B

HOW TO ORDER
1| SPECIFY MODEL
1091AI Failsafe 12/24VDC 3| SPECIFY OPTIONS
1091AIWD Failsafe 12/24VDC, with 8-1/2” x 1-1/2” x 1/8”
B Magnetic Bolt Status Switch
faceplate, specifically for wood frames
SPDT 0.25 Amp @ 30VDC
1091ADLI Failsafe Deadlocking 12/24VDC
Indicates bolt locked and
1091ADLWDI Failsafe Deadlocking 12/24VDC, with 8-1/2” x
bolt unlocked.
1-1/2” x 1/8” faceplate, specifically for wood frames
D Mechanical Door Position
1291AH Failsecure 12/24VDC
Switch
1291AHWD Failsecure 12/24VDC, with 9” x 1-1/2” x 1/8”
SPDT 5 Amps @ 30VDC
faceplate, specifically for wood frames
Integral to the auto relock
2| SPECIFY FINISH ball switch assembly.
V 628 Clear Anodized Aluminum (Standard) Indicates, door closed and
C 605 Bright Brass door open. Recommended
D 606 Dull Brass for minimum security
F 611 Bright Bronze applications only
G 612 Dull Bronze
H 613 Oil Rubbed Bronze
P 625 Bright Chrome
Q 626 Dull Chrome
U 630 Satin Stainless Steel
Y 335 Black Anodized

124
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric
Locking
1091ADMR / 1291ADMR Spacesaver®

Bolt
Devices
Electric Dead Bolt Locks with Mechanical Release

Locks
The Spacesaver®, first designed and patented by
SDC, is a fundamental innovation in electric locking
technology for access control applications.

FEATURES
STAINLESS STEEL BOLT
Greater security is provided by the 0.625” diameter stainless steel
bolt. The bolt rotates freely, making attempts to tamper or cut
extremely difficult.

SPECIFICATION GRADE SOLENOID


All Spacesaver® lock solenoids are manufactured by SDC to
precision specifications. SDC solenoids are capable of superior
overall performance in both force and longevity, providing years of
service compared to commercial grade solenoids.

MECHANICAL RELEASE FUNCTION


When used with a mortise key cylinder (not included), the manual
release assembly will retract the bolt.

FIELD ADJUSTABLE AUTO-RELOCK SWITCH


The automatic relock switch keeps the bolt retracted while the
door is open. The door depresses the ball switch assembly
on closure, causing the bolt to project automatically, locking
the door. In addition, the ball switch assembly is bidirectional,
permitting the locks to be used on swinging and sliding doors.

Fig. 1 Fig. 2
The auto relock assembly is field adjustable to compensate for
wide door gap. (See Figure 1 & 2 above)

INSTALLATION
SDC Spacesaver® locks may be
mounted in the frame header, side
jamb or door lock stile.

MODELS
The stainless steel bolt projects at right angles to the lock
mechanism, allowing installation of Spacesaver® locks, by means 1091ADMR Failsafe 12/24VDC
of a simple cutout, in virtually any standard 1.75” frame, or in 1291ADMR Failsecure 12/24VDC
most door lock stiles. With the entire lock concealed, aesthetic
acceptability is complete, security is greater and installation in
old or new construction is fast, easy and economical.

FIELD YEAR
12
EL
24 W 5
E

L
S

AR
RANT
Y

E C TA B

125
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric Bolt Locks

LOCK FUNCTION SPECIFICATIONS


1091ADMR FAILSAFE 10-1/2”L x 1-1/2”W x 1/8”D
Face Plate
The 1091ADMR is locked when energized. (unless noted differently)
Recommended for safety applications, it is intended Strike 4”L x 1-1/2”W x 1/8”D
that the door unlock automatically when power is
Frame Inner
interrupted by the access control, power failure or 8”L x 1-1/2”W x 1-1/2”D
Dimension
signal from a fire life safety system. See figure 4 below
Requirements
• Bolt Throw 0.75”
Bolt Material Stainless Steel
1291ADMR FAILSECURE
Bolt Diameter 5/8”
The 1291ADMR is locked when de-energized and
1091ADMR: 3/4”
unlocked when energized. Recommended for security Bolt Throw
1291ADMR: 5/8”
applications only, it is intended that the door remains
locked when power is interrupted by a power failure. Mounting Tabs Two aluminum mounting tabs are
• Bolt Throw 0.625” provided for easy lock installation.
See figure 3B below

Dual Voltage 0.45 Amp @ 24VDC Continuous Duty


Coil 0.9 Amp @ 12VDC Continuous Duty

Weight 2.0 lbs

Figure 3A, 3B, 3C, 3D: Typical Frame Header or Side Jamb Installation Figure 4

3A. Mortise cutout in


tube for face plate 3C. Connect wiring
(fits flush with to lock
surface of tube).

3B. Position screws


3D. Slide lock into
for attaching
position, attach
tabs, drill holes,
to tabs.
attach tabs.

PRODUCT SKU SAMPLE: 1091ADMR V D B CYL-6KDQ

HOW TO ORDER
1| SPECIFY MODEL 3| SPECIFY OPTIONS
1091ADMR Failsafe 12/24VDC
1291ADMR Failsecure 12/24VDC B Magnetic Bolt Status Switch
SPDT 0.25 Amp @ 30VDC
Indicates bolt locked and bolt unlocked.
D Mechanical Door Position Switch
2| SPECIFY FINISH SPDT 5 Amps @ 30VDC
V 628 Clear Anodized Aluminum (Standard) Integral to the auto relock ball switch
C 605 Bright Brass assembly. Indicates, door closed and
D 606 Dull Brass door open. Recommended for minimum
F 611 Bright Bronze security applications only
G 612 Dull Bronze
CYL-6KDQ 6 pin, 1-1/8" Keyed different,
H 613 Oil Rubbed Bronze
626 Dull Chrome
P 625 Bright Chrome
Q 626 Dull Chrome CYL-6KAQ 6 pin, 1-1/8" Keyed alike,
U 630 Satin Stainless Steel 626 Dull Chrome
Y 335 Black Anodized

126
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric
Locking
FS23M Dual Failsafe Spacesaver®

Bolt
Bolt Lock

Devices
Locks
Repelling Magnet in Bolt

Repelling Magnet in Strike

The FS23M dual failsafe feature is available only from SDC. Conventional failsafe locking bolts
rely solely on a spring to retract the bolt while the FS23M bolt will unlock with or without the
assistance of the spring. This is the only electric bolt lock listed by the California State Fire
Marshal for locking of perimeter entrance and emergency exit doors after-hours.

FEATURES
DUAL FAILSAFE BOLT DESIGN
The SDC designed and patented FS23M is locked when The bolt is made of a lightweight and extremely resilient
energized. Recommended for safety applications, the door nylon material. While lack of weight enables the magnet to
unlocks automatically when power is interrupted by the eject the bolt, an inherent feature is powerful and smooth
access control, power failure or a signal from the fire life operation. The longevity of this lock is unsurpassed
safety system. compared to electromechanical locks with steel bolts with
abrasive metal to metal interaction.
Large repelling magnets are located within the bolt and Additional bolt features include:
strike. When power is interrupted the bolt is retracted and • 2500lbs Bolt Strength
held back by a spring. Should the spring fail, repelling • Hardened Magnet Core,
magnets eject the bolt from the strike, unlocking the door. Resistant to Metal Cutting Saws

While designed for perimeter applications the performance


characteristics of the FS23M make it the first choice for all
interior or exterior openings where the use of an electric
bolt lock is applicable.

SPECIFICATION GRADE SOLENOIDS


All Spacesaver® lock solenoids are manufactured by MODELS
SDC to precision specifications. SDC solenoids are
FS23MI Dual Failsafe 12/24VDC
capable for superior overall performance in both force and
Dual Failsafe 12/24VDC,
longevity, providing years of service compared to other FS23MWDI
specifically for wood frames
manufacturers off-the-shelf or commercial grade designs.

FIELD YEAR
12
5
POWER

CSFM
24 W
EL
E

DATA
L
S

AR
RANT
Y

E C TA B
3774-0324:001
127
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric Bolt Locks

Figure 3A, 3B, 3C, 3D: Typical Frame Header or Side Jamb Installation Figure 4: End View

3C. Connect
3A. Mortise cutout in wiring to lock.
tube for face plate
(fits flush with
surface of tube).
3B. 3D.
Position screws Slide lock
for attaching into position,
tabs, drill attach to
holes, tabs.
attach tabs.

SPECIFICATIONS
Face Plate 8”L x 1-1/2”W x 1/8”D - standard
8-1/2”L x 1-1/2”W x 1/8”D - wood
INSTALLATION

Strike 4”L x 1.5”W x 1-9/16”D

Frame Inner 8”L x 1-1/2”W x 1-5/8”D


Dimension Requirements See figure 4

Bolt Material Nylon with Center Magnet

Bolt Diameter 5/8”

Bolt Throw 5/8”

Mounting Tabs Two Aluminum Mounting Tabs Are Provided


for Easy Lock Installation See figure 3B

Dual Voltage Coil 0.45 Amp @ 24VDC Continuous Duty, SDC Spacesaver® locks may be
0.9 Amp @ 12VDC Continuous Duty mounted in the frame header, side
jamb or door lock stile.
Weight 1.5 lbs

PRODUCT SKU SAMPLE: FS23MI C D B


HOW TO ORDER

1| SPECIFY MODEL
3| SPECIFY OPTIONS
FS23MI Dual Failsafe 12/24VDC
FS23MWDI Dual Failsafe 12/24VDC, B Magnetic Bolt Status
specifically for wood frames Switch
SPDT 0.25 Amp @ 30VDC
2| SPECIFY FINISH
Indicates bolt locked and
V 628 Clear Anodized Aluminum (Standard) bolt unlocked.
SPECIAL FINISHES: D Mechanical Door Position
C 605 Bright Brass Switch
D 606 Dull Brass SPDT 5 Amps @ 30VDC
F 611 Bright Bronze Integral to the auto relock
G 612 Dull Bronze ball switch assembly.
H 613 Oil Rubbed Bronze Indicates, door closed and
P 625 Bright Chrome door open. Recommended
Q 626 Dull Chrome for minimum security
U 629 Satin Stainless Steel applications only
Y 335 Black Anodized

128
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric
Locking
1190 / 2090 Spacesaver®

Bolt
Bolt Locks

Devices
Locks
1190A 2090A

The Spacesaver®, first designed and patented by SDC, is a fundamental innovation in electric
locking technology for access control applications. The stainless steel bolt projects at right angles
to the lock mechanism, allowing installation of Spacesaver® locks, by means of a simple cutout,
in virtually any standard 1.75” frame, or in most door lock stiles. With the entire lock concealed,
esthetic acceptability is complete, security is greater and installation in old or new construction is
fast, easy and economical.

FEATURES
POWERFUL EXTRA HEAVY DUTY DESIGN FIELD ADJUSTABLE AUTO-RELOCK SWITCH
The 1190 and 2090 Spacesaver® bolt locks are the The automatic relock switch keeps the bolt retracted
most powerful commercial grade units available on the while the door is open. The door depresses the ball
market. They are designed to provide years of trouble free switch assembly on closure, causing the bolt to project
operation. There are only three moving parts within the automatically, locking the door. In addition, the ball switch
hefty solid metal body of the 1190A and five in the 2090A. assembly is bidirectional, permitting the locks to be used
on swinging and sliding doors.
POWERFUL EXTRA HEAVY DUTY SOLENOID
The solenoids are the strongest found in the industry
for commercial or industrial grade applications. The
power and strength of the solenoids far surpasses any
competitive models. All Spacesaver® lock solenoids are
Fig. 1 Fig. 2
manufactured by SDC to precision specifications. SDC
solenoids are capable of superior overall performance in The auto relock assembly is field adjustable to
both force and longevity, providing years of service. compensate for wide door gap. See Figure 1 & 2

CODE COMPLIANCE
Classified in accordance with Uniform Building Code MODELS
standard 7-2, “Fire Test for Door Assemblies” 1190AU Failsafe, 24VDC only
1190AWD Failsafe, 24VDC only,
SOLID STAINLESS STEEL BOLT specifically for wood frames
Greater security is provided by the 0.75” (19 mm) 2090AU Failsecure, 24VDC only
diameter solid stainless steel bolt. The bolt rotates freely, Failsecure, 24VDC only,
making attempts to tamper or cut extremely difficult. 2090AWD
specifically for wood frames

YEAR

W 5
AR
RANT
Y

129
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric Bolt Locks

LOCK FUNCTION
1190A FAILSAFE INSTALLATION
The 1190A is locked when energized. Recommended for safety
applications, it is intended that the door unlock automatically
when power is interrupted by the access control, power failure
or signal from a fire life safety system.
• Bolt Throw 0.75”

2090A FAILSECURE
The 2090A is locked when de-energized and unlocked when
energized. Recommended for security applications only, it
is intended that the door automatically locks when power is
interrupted by the access control or power failure. SDC Spacesaver® locks may
• Bolt Throw 0.75” be mounted in the frame
• Auxiliary Locks header, side jamb or door
• Complies with “Positive Pressure” lock stile.
Requirements of Standard UL10C
• Listed US & Canada
• Bolt Throw 0.75”

Figure 3A, 3B, 3C, 3D: Typical Frame Header or Side Jamb Installation Figure 4

3A. Mortise cutout in


tube for face plate 3C. Connect wiring
(fits flush with to lock
surface of tube).

3B. Position screws


3D. Slide lock into
for attaching
position, attach
tabs, drill holes,
to tabs.
attach tabs.

SPECIFICATIONS

Face Plate 8”H x 1-1/2”W x 1/8”D - standard


PRODUCT SKU SAMPLE: 1190AU D
11”H x 1-3/4”W x 1/8”D - wood
HOW TO ORDER
Strike 4”H x 1-1/2”W x 1/8”D
Frame Inner
1| SPECIFY MODEL
1190A: 8”H x 1-1/2”W x 1-1/2”D
Dimension (See figure 4) 1190AU Failsafe, 24VDC only
Requirements 2090A: 10”H x 1-1/2”W x 1-1/2”D 1190AWD Failsafe, 24VDC only,
specifically for wood frames
Bolt Material Solid Stainless Steel 2090AU Failsecure, 24VDC only
Bolt Diameter 3/4” 2090AWD Failsecure, 24VDC only,
specifically for wood frames
Bolt Throw 3/4”
Mounting Tabs Two aluminum mounting tabs are
2| SPECIFY OPTION
provided for easy lock installation.
See figure 3B B Bolt Position Sensor, SPDT
1190A: 0.7 Amp @ 24VDC
2090A: Inrush 2.5 Amp, Continuous D Door Position Sensor, SPDT
0.5 Amp @ 24VDC
Weight 1.45 lbs
130
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric
Locking
1490 / 2490 Spacesaver®

Bolt
Bolt Locks

Devices
Locks
The Spacesaver® Extra Narrow is fully concealed and easily installed in 1.5” (38.1mm)
frame or door stile. First designed and patented by SDC, the Spacesaver® is a
fundamental innovation in electric locking technology for access control applications.
The stainless steel bolt projects at right angles to the lock mechanism, allowing
installation of Spacesaver® locks, by means of a simple cutout, in virtually any
standard 1.5” frame, or in most door lock stiles. With the entire lock concealed,
esthetic acceptability is complete, security is greater and installation in old or new
construction is fast, easy and economical.

FEATURES
MODELS
SOLID STAINLESS STEEL BOLT
1490AI Failsafe, 24VDC only
Greater security is provided by the .625” diameter
2490AH Failsecure, 24VDC only
stainless steel bolt. The bolt rotates freely, making
attempts to tamper or cut extremely difficult.

SPECIFICATION GRADE SOLENOIDS LOCK FUNCTION


All Spacesaver® lock solenoids are manufactured by
1490A FAILSAFE
SDC to precision specifications. SDC solenoids are
capable of superior overall performance in both force The 1490A is locked when energized. Recommended
and longevity, providing years of service. for safety applications, it is intended that the door
unlock automatically when power is interrupted by
FIELD ADJUSTABLE AUTO-RELOCK SWITCH the access control, power failure or signal from a fire
The automatic relock switch keeps the bolt retracted life safety system.
while the door is open. The door depresses the ball • Bolt Throw 1/2” (12.7mm)
switch assembly on closure, causing the bolt to
project automatically locking the door. In addition,
2490A FAILSECURE
the ball switch assembly is bi-directional, permitting The 2490A is locked when de-energized and
the locks to be used on swinging and sliding doors. unlocked when energized. Recommended for
security applications only, it is intended that the door
automatically locks when power is interrupted by the
access control or power failure.
• Bolt Throw 1/2” (12.7 mm)
Fig. 1 Fig. 2
The auto relock assembly is field adjustable to
compensate for wide door gap. See Figure 1 & 2
YEAR

W 5
AR
RANT
Y

131
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric Bolt Locks

Figure 3A, 3B, 3C, 3D: Typical Frame


INSTALLATION
Header or Side Jamb Installation
3A. Mortise cutout in
tube for face plate
(fits flush with SDC
surface of tube). Spacesaver®
locks may be
mounted in the
frame header,
3B. Position screws side jamb or
for attaching
tabs, drill holes,
door lock stile.
attach tabs.

3C. Connect wiring Figure 4


to lock

1-1/2 1-3/8

3D. Slide lock into


position, attach
to tabs. 1-1/4"

1-1/2

PRODUCT SKU SAMPLE: 1490AI C D B

HOW TO ORDER SPECIFICATIONS

1| SPECIFY MODEL Face Plate 8”L x 1-1/4”W x 1/8”D


1490AI Failsafe, 24VDC Strike 4”L x 1-1/2”W x 1/8”D
2490AH Failsecure, 24VDC
Frame Inner 8”L x 1-1/4”W x 1-3/8”D
2| SPECIFY FINISH Dimension See figure4
V 628 Clear Anodized Aluminum (Standard) Requirements

SPECIAL FINISHES: Bolt Material Stainless Steel


C 605 Bright Brass Bolt Diameter 5/8”
D 606 Dull Brass
F 611 Bright Bronze Bolt Throw 1/2”
G 612 Dull Bronze Mounting Tabs Two aluminum mounting tabs are
H 613 Oil Rubbed Bronze
provided for easy lock installation.
P 625 Bright Chrome
See figure 3B
Q 626 Dull Chrome
U 630 Satin Stainless Steel 1490 Failsafe
Y 335 Black Anodized 0.45 Amp @ 24VDC Continuous Duty
0.9 Amp @ 12VDC Continuous Duty
3| SPECIFY OPTIONS
2490 Failsecure
B Bolt Position Sensor, SPDT
0.45 Amp @ 24VDC Continuous Duty
D Door Position Sensor, SPDT 0.9 Amp @ 12VDC Continuous Duty
Weight 1.4 lbs

132
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric
Locking
100 / 200 Conventional Mortise

Bolt
Bolt Lock

Devices
Locks
The failsafe 110 and failsecure
210 are the most basic bolt
locks available. The bolt
assembly is adjustable forward
up to 1” past the face plate to
accommodate wide door gaps
or special applications Fig. 1 Fig. 2

(See figures 1 & 2).


110/210 Series Not for use in wood frames.

The failsafe 160 and failsecure


260 bolt locks are equipped
with an auto relock switch that
keeps the bolt retracted when
the door is open and causes the
door to lock when closed. The
Fig. 3 Fig. 4
auto relock switch and the bolt
assembly are both adjustable
for wide door gaps.
(See Fig. 3 & 4).
160/260 Series
Not for use in wood frames.

MODELS

110IV Failsafe 160IV Failsafe


2-3/4” H x 1-1/4” W faceplate less auto relock switch 4-7/8” H x 1-1/4” W faceplate with auto relock switch
210HV Failsecure 260HV Failsecure
2-3/4” H x 1-1/4” W faceplate less auto relock swich 4-7/8” H x 1-1/4” W faceplate with auto relock switch

OPTION MC-4 Door Contact Switch (mounted separate from lock)

SPECIFICATIONS APPLICATION
Electrical Specifications •Pharmacy Cabinets
Voltage Dual 900/450 mA @ 12/24 VDC •Gun Cabinets
Mechanical Specifications •Utility Cabinets
Finish 628 Anodized Aluminum •Display Cabinets
Faceplate 110IV, 210HV: 2-3/4” H x 1-1/4” W x 0.25” D
•OEM Applications
160IV, 260HV: 4-7/8” H x 1-1/4” W x 0.25” D
Strike Mortise strike standard. Not for wood frames.
•Swing and Sliding Doors
Bolt 1/2” dia. x 1/2” throw
FIELD
Depth 5”
12
POWER

Weight 1.7 lbs 24


EL
E

DATA
L
S

E C TA B

133
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric Bolt Locks

134
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric
Locking
180 / 280 Series

Bolt
Surface Mount Bolt Locks

Devices
Locks
UNIVERSAL MOUNTING CAPABILITY PROVIDES CONTROLLED
ACCESS OF DOORS, CLOSETS AND CABINETS.

The SDC universal surface mount


electric bolt locks are available in
failsafe and failsecure, non-handed. The
addition of a card reader, digital keypad
or remote control provides access
control and convenience of use for a
variety of applications.

APPLICATION
The SDC 180 and 280 series locks provide the ability to electronically secure several door configurations.
• Swinging or sliding doors • Gun cabinets
• Outswing or inswing doors • Utility cabinets
• Closet doors • Museum display cases
• Pharmaceutical cabinets • Retail display cases

SPECIFICATIONS
Solid Stainless Steel,
Bolt
1/2” dia. x 1/2” throw
0.9 Amp @ 12VDC Continuous PRODUCT SKU SAMPLE: 180AI V MC-4
Dual Voltage Coil
0.45 Amp @ 24VDC Continuous
HOW TO ORDER
Lock Dimensions 6”L x 2”W x 2”H
Auto Relock standard 1| SPECIFY MODEL
Power Regulator standard Surface mount, failsafe, auto relock,
180AI
Weight 2.5 lbs power regulator standard
280AI Surface mount, or top jamb mount,
failsecure, auto relock, power
INSTALLATION
regulator standard
Surface Mount Top Jamb
Outswing Door Inswing or Sliding Door 2| SPECIFY FINISH
V 628 Aluminum (standard)
Y 335 Black
LOCK

LOCK STRIKE 3| SPECIFY OPTIONS


STRIKE
END VIEW Door Contact Switch MP-4
D
(mounted separate from lock)

FIELD YEAR
12
EL
24 W 5
E

L
S

AR
RANT
Y

E C TA B

135
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric Bolt Locks

136
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric
Locking
PD2090A PanicLok™

Bolt
Panic Device Bolt Lock

Devices
Locks
Top Latch Release for Dor-O-Matic and Kawneer Vertical Rod Exit Devices. The PBD2090A
PanicLok™ permits access control and remote timer control of narrow stile glass doors
equipped with Dor-O-Matic or Kawneer concealed vertical rod exit devices.

While the PanicLok™ is used to control entry from the outside only, the exit device is always
operable from the inside for uninhibited egress.

FEATURES
MODELS
FAILSECURE
PD2090ALCU LH/RHR Failsecure
When the PanicLok™ is energized the door is unlocked for free
PD2090ARCU RH/LHR Failsecure
access and egress. When the PanicLok™ is de-energized, the
is door locked on the exterior only. A power supply with battery
backup capability is required for electrical unlocking during a
power failure. INSTALLATION

POWERFUL EXTRA HEAVY DUTY DESIGN


The PanicLok™ is designed with just a few moving parts. The
solenoid is manufactured by SDC to precision specifications
and provides superior performance for years of service.

AUTO RELOCK SWITCH


A ball type auto relock ball switch assembly is standard to
keep the lock bolt retracted when the door is open. When
depressed on door closure the ball switch causes the bolt
to project, locking the door automatically. The auto relock
assembly is also adjustable to compensate for wide door gaps.
The PanicLok™ is adaptable to
single or pairs of center hung
SPECIFICATIONS doors and offset doors with a
Face Plate 10”H x 1-1/2”W x 1/8”D minimum of 0.125” reveal.

Frame I.D. Requirements 1.5”H x 1.5”W


Bolt Beveled Stainless Steel
Voltage 24VDC Only (Suffix C)
Current 2.5 Amp Inrush, 400 mA Continuous YEAR

Weight 2.0 lbs W 5


AR
RANT
Y

137
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric Bolt Locks

138
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Specialty
Locking Locks
GL160/GL260 GateLok™

Devices
Outdoor Lock for Swinging or Sliding Gates
The SDC GL160 and 260 Series GateLok™ are
designed to provide access control and remote locking
and unlocking capability for manual or automatic chain
link, tubular steel and wrought iron sliding or swinging
Tubular Steel and Wrought Iron Gates. Higher Security
than Electromagnetic Locks.
FEATURES
• Higher Security Than Electromagnetic Locks
• Solid Stainless Steel 0.625" Diameter Locking Bolt
• Continuous Duty Operation
• Low Current Draw
• Auto Relock Switch
• Heavy Gauge 0.125"
• Weather Sealed Steel Housing
• Access Control Compatible
• Designed for 3” Fence Post and 2” Gate Post and are Adaptable for Smaller Sizes

LOCK OPERATION
The GL160A/GL260A* GateLoks™ may be unlocked by
an access control and remote control.
SPECIFICATIONS
The GL163A/GL263A* GateLok™ may be unlocked by Size 5”W x 6-1/2”H x 2”D
an access control, remote control and built-in keyswitch.
Material 1/8” Steel

The GL260MRA GateLok™ may be unlocked by an Bolt 5/8” Dia. x 5/8” Throw
access control, remote control and built-in mechanical
ANSI 1-1/8” or 1-1/4” Standard or
key. The mechanical key is for momentary override Key Cylinder Interchangeable Core Mortise Key Cylinder.
and does not maintain a sustained unlocked mode. Provided by Others.
Mechanical key retracts the bolt even without DC power.
Failsafe 12/24 VDC 900/450mA

Standard with all GateLoks™ the adjustable Auto Failsecure 12/24 VDC 900/450mA
Relock Switch keeps the bolt retracted until the gate is
Finish Black
in the closed position.
*Note: GL260A and GL263A cannot be unlocked without DC power. Weight 9.0 lbs

PRODUCT SKU SAMPLE: GL160AI D B


HOW TO ORDER
1| SPECIFY MODEL 2| SPECIFY OPTIONS
GL160AI Failsafe, 12/24VDC D Gate Position Sensor SPDT,
GL163AI Failsafe, Built-In Keyswitch 12/24VDC 10Amp @ 30VDC
GL260AH Failsecure 12/24VDC B Bolt Lock Position Sensor,
GL263AH Failsecure, Built-In Keyswitch, 12/24VDC 10Amp @ 30VDC
GL260MRAH Failsecure, Mechanical Key Release, 12/24VDC CYL-KDQ 6 pin, 1.125” mortise cylinder,
Mortise Key Cylinder Provided by Others. keyed different, dull chrome

FIELD YEAR
12
EL
24 W 5
E

L
S

AR
RANT
Y

E C TA B

139
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Specialty Locks

140
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Specialty
Locking Locks
290 Micro
Cabinet Lock

Devices
The 290 Micro Cabinet Lock is designed to
electronically secure cabinets and drawers.
The need for keys is eliminated and the
addition of a keypad or remote control of
your choice provides true access control and
convenience of use.

FEATURES
MODELS
• For Swinging or Sliding Doors
290 Micro Cabinet Lock
• Failsecure Continuous Duty
290LS Micro Cabinet Lock with Lock Status Switch
• Field Reversible Solenoid for Failsafe Operation
• Dual 12/24VDC
• Nonhanded
• 600lbs of Holding Force SWINGING SLIDING DOOR
DOOR DRAWER

APPLICATION
• Pharmaceutical Cabinets and Drawers
• Retail Display Cases and Drawers
• Gun Cabinets
• File Cabinets
• Utility Cabinets and Drawers
• Museum Dsplay Cases Side entry Side entry Slide entry

SPECIFICATIONS Strike can enter lock from


any of 3 sides and also
Dual Voltage 250/130mA @ 12/24VDC Front entry sliding from the side

Dimensions 3-1/4”L x 1-1/8”W x 1-1/8D”

Weight 0.4 lbs


FIELD YEAR
12
EL
24 W 5
E

L
S

AR
RANT
Y

E C TA B

141
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Specialty Locks

142
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Specialty
Locking Locks
295 Programmable
Cabinet Lock

Devices
The SDC 295 Battery Powered Keyless
Cabinet Lock provides an easy, economical
solution for security and keyless access
control for a wide variety of cabinet doors,
drawers, storage lockers and more. Quickly
and easily add/delete up to 30 individual
user PIN codes with programmable keypad.
Powered by 2 x AAA batteries, the need for
low voltage wiring is eliminated.

FEATURES
• For New Installations or Retrofit of Existing Manual
Cam Lock Prep MODELS
• Vertical or Horizontal Keypad Mounting 295 Programmable Cabinet Lock
• Multiple Locking Cam Positions, Left/Right, Bottom
• Programmable Multiple User Mode or 1-Time
Use Mode
• 1 Master Code: Full Programming and
Control Capabilities.
• 1 Sub-Master: Limited Programming for User Codes,
SPECIFICATIONS
Maintained Unlock, Unlock Time Only
• 30 User, 4-6 Digit PIN Codes, Must be Same Length Supplied Locking (A) 1-1/2” From Spindle Centerline
as Master Code. Field Optional User Changeable PIN Cams (B) 1” From Spindle Centerline
• Unlock Time Programmable From 1 to 9 sec. Door Thickness Up to 3/4”
Factory Default 3 Sec.
Cam Mounting 5/16” Square Spindle
• Red/Blue Bi-Color LED
Hole Required for
• Keypad Tamper Lockout: Inoperable for 10 Seconds 15/16” Diameter
Spindle
After 3 Incorrect Code Entries
• 2 x AAA Batteries (Included), Up to 15,000 Operations Battery Powered 2x AAA Batteries

• Concealed Manual Key Cylinder (Replaceable), 2 Keys Dimensions 4.75”H x 1.4”W x 0.8”D - 1.4”D w/Dial

• Battery Failure Override, Apply 9V Battery to External Weight 0.4 lbs


Contacts, Enter Master Code
YEAR

W 5
AR
RANT
Y

143
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Specialty Locks

APPLICATION
• Retail and Museum: Display Cases, Cabinets • Law Enforcement: Firearm, Evidence Lockers,
• Laboratory, Healthcare, Pharmaceutical: Files, Cabinets, Desk Drawers
Cabinets, Lockers and Carts • Rack / Cabinets: Servers, LAN, HVAC,
• Businesses and Schools: Office, kitchen and Communications
Bathroom Cabinets, File Cabinets, Desk Drawers, • Electrical/Equipment Enclosures: Hinged Electrical
Lockers and Carts Cabinets, NEMA, Floor and Wall Mount
• Industrial/Manufacturing: Metal and Wood Cabinetry • Security Equipment: Key Control Cabinets, Alarm and
for Tools, Supplies, Inventory, Hazardous Material Power Supply Cabinets
Storage • Console Cabinets: Security/CCTV, Guard Console
• Residential: Cabinetry, Closets, Desks and Files Station/Cabinet

PROGRAMMING FUNCTIONS OVERVIEW


• Change Master Code/Code Length: • Add/Change/Delete Sub-Master Code:
Performs all program functions Performs following programs only
• Select Operation Mode • Set Unlock Time
• Delete ALL User Codes • Add / Change User Code
• Reset to Factory Settings • Suspend / Restore User Code
• Suspend / Restore ALL User Codes
• Enable/Disable Maintained Unlock Mode

144
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Electric
LockingBolt
Devices
Locks

145
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM

You might also like