GENERAL FEATURES APPLICATIONS

Environmentally friendly UPS & EPS


DATASHEET

 
 Can be used at vertical or horizontal  Emergency lighting Systems
orientation  Medical Equipment
 High Reliability and Good Quality  Cable TV Systems
 High gas recombination efficiency  Alarm Systems
 High Power Density  Electric Test Equipment
 Maintenance-Free Operation  Security Systems

DIMENSIONS & WEIGHT TECHNICAL SPECIFICATIONS Art. no: SAAS12-12


Length(mm) 152±1 Nominal Voltage 12V(6 cells per unit)
Width(mm) 99±1 Design Floating Life @25℃ 5 Years
Heighth(mm) 96±1 Nominal Capacity @25℃(20 hour rate@0.60A,10.50V) 12.0Ah

Total Heighth(mm) 102±1 10 hour rate (1.13A,10.8V) 11.3Ah


Capacity @25℃ 5 hour rate (2.14A,10.5V) 10.7Ah
Weight(kg) 3.38±3%
1 hour rate (7.83A,9.6V) 7.83Ah
152 99
62 79 Internal Resistance Full Charged Battery@25℃ ≤16.0mΩ
Discharge -20℃~50℃
Ambient Temperature Charge -20℃~50℃
102
96

Storage -20℃~50℃
Max.Discharge Current@25℃ 180A(5s)

F2(NO.250) Terminal
40℃ 102%
Capacity affected by
25℃ 100%
Unit: mm
A direction

Temperature
0.4

0℃ 85%
0.8
6

A direction
(10 hr Capacity )
-15℃ 65%
6.35
4.3

7.8

Self-Discharge@25℃ per Month 3%


COMPLIED STANDARDS
Initial Charging Current Less than 3.6A
IEC 60896-21/22 JIS C8704 Floating Charge
Charge (Constant Voltage 13.6-13.8V
YD/T799 BS6290 part4
Voltage) @25℃ Initial Charging Current Less than 3.6A
GB/T 19639 UL 1989 Cycle Charge
Voltage 14.4-14.9V

BATTERY DISCHARGE TABLE


Discharge Constant Current per Cell (Amperes at 25°C)
F.V/Time 5min 10min 15min 30min 45min 1h 2h 3h 5h 8h 10h 20h
1.60V 47.90 31.41 23.06 13.69 9.98 7.83 4.95 3.39 2.26 1.52 1.20 0.634
1.67V 45.63 30.10 22.56 13.46 9.82 7.58 4.87 3.33 2.23 1.49 1.18 0.622
1.70V 43.71 28.46 22.25 13.28 9.69 7.34 4.77 3.27 2.18 1.46 1.17 0.612
1.75V 41.66 27.14 21.07 12.84 9.44 7.11 4.68 3.21 2.14 1.45 1.15 0.600
1.80V 38.47 25.28 19.66 12.33 9.13 6.91 4.51 3.09 2.06 1.40 1.13 0.593
Discharge Constant Power per Cell (Watts at 25°C)
F.V/Time 5min 10min 15min 30min 45min 1h 2h 3h 5h 8h 10h 20h
1.60V 89.19 60.27 44.57 26.62 19.47 15.41 9.72 6.69 4.48 3.03 2.41 1.265
1.67V 85.47 57.83 43.71 26.25 19.22 14.88 9.55 6.57 4.40 2.99 2.39 1.246
1.70V 81.96 54.70 43.22 25.95 19.03 14.35 9.37 6.45 4.33 2.94 2.37 1.231
1.75V 78.51 52.23 41.01 25.17 18.57 13.82 9.20 6.33 4.24 2.92 2.33 1.205
1.80V 73.20 48.85 38.33 24.24 18.00 13.29 8.83 6.08 4.08 2.84 2.30 1.200

ABS-LINE | www.abs-line.de | anfrage@industriebatterie.de


In den Wiesen 2 · 49451 Holdorf · Germany
PERFORMANCE CHARACTERISTICS
Temperature effect on Design Service life
DATASHEET

Charging characteristics
Charging
Volume

Voltage
Current

@25℃/77°F 84
(%) (A) (V) Charging voltage:13.65±0.10V/piece
120 0.12C 15.00 72
charging volume

Life month
100 0.10C 14.40 60
80 0.08C 13.80
charging voltage 48
60 0.06C 13.20
36
40 0.04C 12.60
After 100%DOD
Float charging voltage:13.65±0.10V
After 50% DOD
24
20 0.02C 12.00
charging current

0 0
0 4 8 12 16 20 24 28 32 36
0 10 20 30 40 50 60
Charging time(hour) Temperature(°C)

Cycle life vs.Depth of discharge Discharge characteristics(@25℃/77°F)


@25°C/77°F 13.20
12.60
Voltage(V)
12.00

11.40
Capacity %

10.80
0.10C 0.05C
0.55C 0.25C 0.17C
10.20
100%DOD 50%DOD 30%DOD 9.60
3C 2C 1C
9.00
8.40

0 1 5 7 10 20 30 60 2 3 5 10 20
min h

Cycle life(times) Discharging time(hour)

Temperature effect Temperature effect on capacity


on battery self-discharge 120
Residual capacity(%)

0.05CA
120 0.10CA
100
Capacity(%)

0.20CA
100
80
80 0.55CA
0°C/32°F 1.00CA
60
10°C/50°F
60
2.0CA
20°C/68°F 40
40
40°C/104°F 30°C/86°F 20
20

0
0 2 4 6 8 10 12 14 16 18 20 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40

Storage time(month) Temperature(°C)

BATTERY CONSTRUCTION
Positive Container Pillar
Component Negative plate Safety valve Terminal Separator Electrolyte
plate &Cover seal
Balanced Two
Thick high Flame Female Advanced AGM
Pb-Ca grid for ABS Dilute high layers
Sn low Ca Si-Rubbeand Copper separator for
Features improved (UL94-V0 purity sulphuric epoxy
grid with aging Insert high pressure
recombination optional) acid resin
special paste resistancer (F1/F2) cell design
efficiency seal

ABS-LINE | www.abs-line.de | anfrage@industriebatterie.de