(TDB) CAC Universal For SAMCOL (R410A, HP) Ver.1.2 - 180920 (Liviano) PDF
(TDB) CAC Universal For SAMCOL (R410A, HP) Ver.1.2 - 180920 (Liviano) PDF
(TDB) CAC Universal For SAMCOL (R410A, HP) Ver.1.2 - 180920 (Liviano) PDF
Technical
Data Book
SINGLE for SAMCOL
(R410A, HP)
History
2
Features & Benefits
Maintain optimal comfort and control with energy Stabilize the atmosphere with broad temperature
and cost-efficient technologies allowance and control
Featuring a suite of energy-optimizing technologies, Samsung is dedicated to supporting comfortable living
Samsung CAC Single delivers top-class energy efficiency and working environments based on the strength of
to support business in saving costs and the environment. its technologies. With a single unit, CAC Single delivers
reliable comfort and control over multiple areas to
Small package, big performance ensure a pleasant atmosphere in any climate.
The Samsung Ceiling Type air conditioner boasts a Wide temperature performance
slim, compact design—half the size of conventional
products—with cooling power comparable to larger No matter how extreme the temperature, the high-
units. performing CAC Single can handle the condition-
without the need for an additional unit. Featuring a wide
Multi-unit operation temperature allowance, it can cool in heat of up to 50
Instead of connecting just one indoor unit, users can
ensure a constant and comfortable home environment.
connect two indoor units with a single outdoor unit for
more efficient cooling and heating. The indoor units
operate and are controlled simultaneously as one cycle Ideal comfort in minutes
within the same mode via one remote controller for up The CAC Single digital inverter air conditioner works
to four rooms. This system is ideal for spaces requiring at maximum capacity at startup. As soon as the
multiple indoor units, such as open-plan offices or shops. temperature reaches the desired or set temperature,
CAC Single performs fine adjustments to cope with any
Outdoor unit Capacity changes. This means less temperature fluctuation and
2 Rooms
(kBtu/h) ideal comfort in a matter of minutes.
48 24 + 24
Steady Temperature Fluctuation
Non-inverter
High Temperature Fluctuation
Uncomfortable 25 C
(Energy Loss)
24 C
Comfortable
Uncomfortable
(Energy Loss) 23 C
3
Nomenclature
Indoor Unit
Model Name
AC 036 M N 4 P K H CB
(1) (2) (3) (4) (5) (6) (7) (8) Buyer
(3) Version
(6) Feature
H 2014
J 2015 F Flagship
K 2016 S Standard
M 2017 D Deluxe
P Premium
(8) Mode
4
Nomenclature
Outdoor Unit
Model Name
AC 036 M X A D K H CB
(1) (2) (3) (4) (5) (6) (7) (8) Buyer
(6) Feature
(2) Capacity
F Flagship
X 1,000 Btu/h (3 digits) S Standard
D Deluxe
P Premium
(3) Version
H 2014
J 2015 (7) Rating Voltage
K 2016 K
M 2017 N
5
Line-up
Indoor unit
Capacity (kBtu/h)
Model
24.0 36.0 48.0
4Way CST
360 CST
Ceiling
Outdoor Unit
Capacity (kBtu/h)
Model
24.0 36.0 48.0
1Phase
6
Contents
4Way Cassette 8
360 Cassette 25
Big Ceiling 44
Outdoor Units 57
Installation 76
Accessory 98
7
4Way Cassette
1. Specification 10
2. Summary Table 13
3. Capacity Table 14
4. Dimensional Drawing 17
5. Center of Gravity 19
6. Electrical Wiring Diagram 20
7. Sound Data 21
8. Temperature and air flow distribution 22
8
Features & Benefits
4Way Cassette
Stage a beautiful yet comfortable environment The Samsung 4Way Cassette indoor air conditioning
system delivers polish, comfort and efficiency with
With its newly improved design, 4Way Cassette supports features such as:
a clean, aesthetically appealing atmosphere and adds
a sense of sophistication to work and living spaces. • Stylishly clean design. Add panache to interior
Not only is this unit attractively designed, but it also spaces with a choice of clean, streamlined panel
uses advanced technologies to optimize comfort in any patterns in a lightweight build.
environment. • Robust operation. Control the atmosphere
perfectly with an advanced design for superior air
flow and cooling/heating performance.
• Low maintenance and simple installation. Ease
installation and minimize maintenance with a
detachable, no-drip design.
Complement any interior with a sleek, lightweight design Neat and clean design
The new Samsung 4Way Cassette indoor air conditioner The indoor 4Way Cassette boasts a smart design
comes in a choice of patterns with a simple panel that promotes a neat and clean look. The completely
to better match the interior design. Its uniquely hermetic blade structure keeps the indoor unit clean
lightweight frame makes installation easy, while clever by preventing dust or other foreign substances from
blade construction keeps the unit clean for a tidy entering it. The internal parts of the indoor unit
appearance. are also out of sight when the blade is shut, thus
improving the unit’s appearance.
Lightweight build
The Samsung 4Way Cassette indoor unit is now lighter
in weight at 18 kg. It is one of the lightest indoor
units in the industry, about 40 percent lighter than
conventional products.
4Way Casseette Conventional
Aesthetic panel and display
4Way Cassette offers two different pattern designs for
the panel. Users can select either the Waffle or Classic
pattern to create just the right look to suit their design
preference. Plus, the simple display design with rounded
corners adds a chic sophistication to the interior.
*Based on 10kW
9
1. Specification
4Way Cassette
10
1. Specification
4Way Cassette
11
1. Specification
4Way Cassette
NOTE
• Specification may be subject to change without prior notice.
1) Capacities are based on (Equivalent refrigerant piping 5m, Level differences 0m);
- Cooling : Indoor temperature 27.0°C DB, 19.0°C WB / Outdoor temperature 35.0°C DB, 24.0°C WB
- Heating : Indoor temperature 20°C DB, 15°C WB / Outdoor temperature 7°C DB, 6°C WB
2) Select wire size based on the value of MCA
3) Sound pressure level is obtained in an anechoic room.
- Sound pressure level based on T1 condition (Indoor temperature 27°C DB, 19°C WB /
Outdoor temperature : 35°C DB, 24°C WB)
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A-weighted sound pressure level
- Reference acoustic pressure 0 dB = 20uPa
4) These products contain R410A which is fluorinated greenhouse gas.
• In case you want to know more information regarding capacity and correction, please refer to capacity table
TDB on pvi.samsung.com site.
12
2. Summary Table
4Way Cassette
Performance Characteristics
Capacity
Net Weight Airflow Sound Pressure Level
Model Code Cooling Heating Fan Speed
(kg) (CMM) (dBA)
(Btu/h) (Btu/h)
Max. 28,500 32,000 High 19.5 36
AC024MN4DKH/CB 15.0 Std. 24,000 27,000 Mid 16.5 33
Min. 7,500 6,500 Low 14.5 29
Max. 40,900 52,900 High 31.0 44
AC036MN4DKH/CB 18.0 Std. 34,000 38,000 Mid 25.0 39
Min. 10,200 7,500 Low 19.0 33
Max. 56,000 64,000 High 33.1 45
AC048MN4DKH/CB 20.0 Std. 42,000 52,900 Mid 27.5 41
Min. 12,000 12,000 Low 22.0 37
NOTE
• Sound data is based on cooling operation.
Electric Characteristics
NOTE
• MCA : Minimum circuit amperes
• MFA : Maximum fuse amperes
• Select wire size based on the value of MCA
13
3. Capacity Table
4Way Cassette
AC024MN4DKH/CB+AC024MXADKH/CB
Cooling
Outdoor 20 / 14 22 / 16 25 / 18 27 / 19 28 / 20 30 / 22 32 / 24
Temperature
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW
-15 23.4 19.3 1.69 24.6 19.9 1.72 25.7 20.5 1.76 26.5 21.2 1.79 27.0 21.0 1.81 28.3 20.7 1.83 29.8 20.3 1.87
21 22.3 18.4 1.78 23.5 19.0 1.81 24.4 19.6 1.85 25.2 20.2 1.89 25.7 20.0 1.91 27.0 19.8 1.93 28.3 19.4 1.96
35 21.2 17.5 2.22 22.3 18.1 2.27 23.3 18.6 2.31 24.0 19.2 2.36 24.5 19.0 2.38 25.7 18.8 2.41 27.0 18.4 2.46
46 18.0 16.3 2.00 19.0 16.8 2.04 19.8 17.3 2.08 20.4 17.8 2.12 20.8 17.6 2.15 21.8 17.5 2.17 22.9 17.1 2.21
50 13.8 12.8 1.78 14.5 13.2 1.81 15.1 13.6 1.85 15.6 14.0 1.89 15.9 13.9 1.91 16.7 13.8 1.93 17.5 13.5 1.96
Heating
Outdoor Temperature 16 18 20 21 22 24
TC PI TC PI TC PI TC PI TC PI TC PI
MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW
-20 19.0 3.12 18.8 3.09 18.6 3.06 18.4 3.02 18.3 2.99 18.1 2.96
-15 24.0 3.60 23.7 3.56 23.5 3.53 23.3 3.49 23.0 3.45 22.8 3.42
-5 27.0 3.36 26.7 3.32 26.5 3.29 26.2 3.26 25.9 3.22 25.7 3.19
0 28.1 2.88 27.8 2.85 27.5 2.82 27.3 2.79 27.0 2.76 26.7 2.74
7 27.5 2.40 27.3 2.37 27.0 2.35 26.7 2.33 26.5 2.30 26.2 2.28
24 35.8 2.76 35.5 2.73 35.1 2.70 34.7 2.68 34.4 2.65 34.1 2.62
NOTE
• The performance table shows the average value of each conditions.
14
3. Capacity Table
4Way Cassette
AC036MN4DKH/CB+AC036MXADKH/CB
Cooling
Outdoor 20 / 14 22 / 16 25 / 18 27 / 19 28 / 20 30 / 22 32 / 24
Temperature
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW
-15 33.3 27.5 2.23 35.0 28.3 2.28 36.5 29.2 2.32 37.6 30.1 2.37 38.4 29.8 2.39 40.3 29.5 2.42 42.3 28.9 2.47
21 31.7 26.2 2.35 33.4 27.0 2.40 34.8 27.8 2.45 35.8 28.7 2.50 36.5 28.4 2.52 38.4 28.1 2.55 40.3 27.5 2.60
35 30.2 24.9 2.94 31.8 25.7 3.00 33.1 26.5 3.06 34.0 27.3 3.10 34.8 27.0 3.15 36.5 26.8 3.18 38.4 26.2 3.25
46 25.7 24.1 2.64 27.0 24.8 2.70 28.1 25.6 2.75 29.0 26.4 2.81 29.6 26.1 2.84 31.1 25.9 2.86 32.6 25.3 2.92
50 19.6 19.2 2.35 20.7 19.8 2.40 21.5 20.4 2.45 22.2 21.1 2.50 22.6 20.9 2.52 23.8 20.6 2.55 24.9 20.2 2.60
Heating
Outdoor Temperature 16 18 20 21 22 24
TC PI TC PI TC PI TC PI TC PI TC PI
MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW
-20 26.9 4.11 26.6 4.07 26.4 4.03 26.1 3.99 25.8 3.95 25.6 3.91
-15 33.9 4.74 33.6 4.70 33.2 4.65 32.9 4.60 32.6 4.56 32.3 4.51
-5 38.2 4.43 37.8 4.38 37.5 4.34 37.1 4.30 36.7 4.25 36.3 4.21
0 39.8 3.79 39.4 3.76 39.0 3.72 38.6 3.68 38.2 3.65 37.8 3.61
7 39.0 3.16 38.6 3.13 38.0 3.08 37.8 3.07 37.5 3.04 37.1 3.01
24 50.7 3.64 50.2 3.60 49.7 3.57 49.2 3.53 48.7 3.49 48.2 3.46
NOTE
• The performance table shows the average value of each conditions.
15
3. Capacity Table
4Way Cassette
AC048MN4DKH/CB+AC048MXADKH/CB
Cooling
Outdoor 20 / 14 22 / 16 25 / 18 27 / 19 28 / 20 30 / 22 32 / 24
Temperature
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW
-15 41.0 33.8 2.55 43.1 34.9 2.60 44.9 35.9 2.65 46.3 37.0 2.71 47.2 36.7 2.73 49.6 36.3 2.76 52.1 35.6 2.81
21 39.0 32.2 2.68 41.1 33.2 2.74 42.8 34.2 2.79 44.1 35.3 2.85 45.0 34.9 2.88 47.2 34.6 2.90 49.6 33.9 2.96
35 37.2 30.7 3.35 39.1 31.6 3.42 40.7 32.6 3.49 42.0 33.6 3.56 42.8 33.3 3.60 45.0 32.9 3.63 47.2 32.3 3.70
46 31.6 28.5 3.02 33.2 29.3 3.08 34.6 30.2 3.14 35.7 31.2 3.20 36.4 30.9 3.24 38.2 30.6 3.27 40.1 29.9 3.33
50 24.2 22.4 2.68 25.4 23.1 2.74 26.5 23.8 2.79 27.3 24.6 2.85 27.8 24.3 2.88 29.2 24.1 2.90 30.7 23.6 2.96
Heating
Outdoor Temperature 16 18 20 21 22 24
TC PI TC PI TC PI TC PI TC PI TC PI
MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW
-20 37.2 6.35 36.9 6.29 36.5 6.23 36.1 6.16 35.8 6.10 35.4 6.04
-15 46.9 7.33 46.5 7.26 46.0 7.19 45.6 7.11 45.1 7.04 44.7 6.97
-5 52.9 6.84 52.4 6.77 51.8 6.71 51.3 6.64 50.8 6.57 50.3 6.51
0 55.0 5.86 54.5 5.81 54.0 5.75 53.4 5.69 52.9 5.63 52.4 5.58
7 54.0 4.89 53.4 4.84 52.9 4.79 52.4 4.74 51.8 4.69 51.3 4.65
24 70.2 5.62 69.5 5.56 68.8 5.51 68.1 5.45 67.4 5.40 66.7 5.34
NOTE
• The performance table shows the average value of each conditions.
16
4. Dimensional Drawing
4Way Cassette
AC024MN4DKH/CB
Units : mm [inches]
Description
No. Name
AC024MN4DKH/CB
1 Liquid pipe connection
2 Gas pipe connection
3 Drain pipe connection VP-25(OD32, ID25)
4 Power supply & Communication wiring conduit
5 Sub duct connection Use M4 Screw
6 Fresh air intake knockout hole
NOTE
• As for suspension bolt, please use M8 ~ M10.
(Procured at local site)
17
4. Dimensional Drawing
4Way Cassette
AC036/048MN4DKH/CB
Units : mm [inches]
NOTE
• As for suspension bolt, please use M8 ~ M10.
(Procured at local site)
18
5. Center of Gravity
4Way Cassette
Units : mm [inches]
A B C D
AC024MN4DKH/CB 204 [8] 70 [2-3/4] 410 [ 16-1/8] 360 [14-3/16]
AC036/048MN4DKH/CB 288 [11-3/8] 130[5] 420 [16-1/2] 420 [16-1/2]
19
6. Electrical Wiring Diagram
4Way Cassette
SUB PBA Printed Circuit Board(SUB) SPI S-Plasma ion ROOM(10K) Thermistor ROOM OUT(10K)
M-BLDC BLDC Motor Electronic Expansion Valve Thermistor EVA IN(10K)
EXT_CONTROL EXTERNAL_CONTROL Thermistor EVA OUT(10K)
NOTE
• This wiring diagram applies only to the Indoor unit.
• Symbols show as follow :
blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue: grn: green
• For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remote controller transmission F3-F4.
• Protective earth(screw), : connector, : The wire quantity
20
7. Sound Data
4Way Cassette
Microphone
• NC Curve
1) AC024MN4DKH/CB 2) AC036MN4DKH/CB
70 70 70 70
65 65 65 65
NC 70
60 60 60 NC 65 60
NC 60
55 55 55 55
Sound Pressure Level (dB)
NC 60
NC 55
50 50 50 NC 55 50
High
NC 50
45 45 45 NC 50 45
NC 45
40 40 40 Low 40
High NC 45
NC 40 35
35 35 35
Low NC 40
NC 35 30 30
30 30 NC 35
NC 30 25 25
25 25 NC 30
20 NC 25 20 20 20
NC 25
NC 20 15 15
15 15 NC 20
10 NC 15 10 10 10
NC 15
5 5 5 5
0 0 0 0
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency(Hz) Octave Band Center Frequency(Hz)
3) AC048MN4DKH/CB
70 70
65 65
NC 70
60 60
NC 60
55 55
NC 55
50 High 50
NC 50
45 45
NC 45
40 Low 40
NC 40
35 35
NC 35
30 30
NC 30
25 25
20 NC 25 20
15 NC 20 15
10 NC 15 10
5 5
0 0
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency(Hz)
NOTE
• Specifications may be subject to change without prior notice.
- Sound pressure level is obtained in an anechoic room.
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A weighted sound pressure level
-
21
8. Temperature and air flow distribution
4Way Cassette
AC024MN4DKH/CB
22
8. Temperature and air flow distribution
4Way Cassette
AC036MN4DKH/CB
23
8. Temperature and air flow distribution
4Way Cassette
AC048MN4DKH/CB
24
360 Cassette
1. Specification 27
2. Summary Table 30
3. Capacity Table 31
4. Dimensional Drawing 34
5. Center of Gravity 38
6. Electrical Wiring Diagram 39
7. Sound Data 40
8. Temperature and air flow distribution 41
25
Features & Benefits
360 Cassette
A bladeless design softly disperses cool air across the An innovative Booster Fan enables cool air to be
room, making you comfortably cool without feeling a expelled at much lower angles. It creates a low pressure
cold draft**. With no blades to block the air flow, it also area around the outlet, so that cool air comes out
expels 25% more air* and spreads it farther. parallel to the ceiling and disperses across a wider area.
Circular to perfectly fit in everywhere All round simpler & intuitive control
Its innovative circular design can match a multitude of Intuitively control its performance and see where the
interior designs, so it perfectly fits in everywhere. Its air is going. The Wireless Remote Controller's* Jog
minimalist modern styling creates a sophisticated look shuttle and button offer a fun way to adjust the air flow
and its circular shape stands out beautifully. and a Circular LED Display shows its direction.
*Optional
26
1. Specification
360 Cassette
27
1. Specification
360 Cassette
28
1. Specification
360 Cassette
NOTE
• Specification may be subject to change without prior notice.
1) Capacities are based on (Equivalent refrigerant piping 5m, Level differences 0m);
- Cooling : Indoor temperature 27.0°C DB, 19.0°C WB / Outdoor temperature 35.0°C DB, 24.0°C WB
-
2) Select wire size based on the value of MCA
3) Sound pressure level is obtained in an anechoic room.
- Sound pressure level based on T1 condition (Indoor temperature 27°C DB, 19°C WB /
Outdoor temperature : 35°C DB, 24°C WB)
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A-weighted sound pressure level
- Reference acoustic pressure 0 dB = 20uPa
4) These products contain R410A which is fluorinated greenhouse gas.
• In case you want to know more information regarding capacity and correction, please refer to capacity table
TDB on pvi.samsung.com site.
29
2. Summary Table
360 Cassette
Performance Characteristics
Capacity
Net Weight Airflow Sound Pressure Level
Model Code Cooling Heating Fan Speed
(kg) (CMM) (dBA)
(Btu/h) (Btu/h)
Max. 28,500 32,000 High 17.5 36
AC024MN4PKH/CB 20.2 Std. 24,000 27,000 Mid 15.9 33
Min. 7,500 6,500 Low 14.3 29
Max. 40,900 52,900 High 31.2 44
AC036MN4PKH/CB 23.5 Std. 34,000 38,000 Mid 25.5 39
Min. 10,200 7,500 Low 19.8 33
Max. 56,000 64,000 High 32.4 45
AC048MN4PKH/CB 25.5 Std. 42,000 52,900 Mid 27.1 41
Min. 12,000 12,000 Low 22.8 37
NOTE
• Sound data is based on cooling operation.
Electric Characteristics
NOTE
• MCA : Minimum circuit amperes
• MFA : Maximum fuse amperes
• Select wire size based on the value of MCA
30
3. Capacity Table
360 Cassette
AC024MN4PKH/CB+AC024MXADKH/CB
Cooling
Outdoor 20 / 14 22 / 16 25 / 18 27 / 19 28 / 20 30 / 22 32 / 24
Temperature
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW
-15 23.4 19.3 1.77 24.6 19.9 1.80 25.7 20.5 1.84 26.5 21.2 1.88 27.0 21.0 1.90 28.3 20.7 1.91 29.8 20.3 1.95
21 22.3 18.4 1.86 23.5 19.0 1.90 24.4 19.6 1.94 25.2 20.2 1.98 25.7 20.0 2.00 27.0 19.8 2.02 28.3 19.4 2.06
35 21.2 17.5 2.32 22.3 18.1 2.37 23.3 18.6 2.42 24.0 19.2 2.47 24.5 19.0 2.49 25.7 18.8 2.52 27.0 18.4 2.57
46 18.0 16.3 2.09 19.0 16.8 2.13 19.8 17.3 2.18 20.4 17.8 2.22 20.8 17.6 2.25 21.8 17.5 2.27 22.9 17.1 2.31
50 13.8 12.8 1.86 14.5 13.2 1.90 15.1 13.6 1.94 15.6 14.0 1.98 15.9 13.9 2.00 16.7 13.8 2.02 17.5 13.5 2.06
Heating
Outdoor Temperature 16 18 20 21 22 24
TC PI TC PI TC PI TC PI TC PI TC PI
MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW
-20 19.0 3.18 18.8 3.15 18.6 3.12 18.4 3.09 18.3 3.06 18.1 3.03
-15 24.0 3.67 23.7 3.64 23.5 3.60 23.3 3.56 23.0 3.53 22.8 3.49
-5 27.0 3.43 26.7 3.39 26.5 3.36 26.2 3.33 25.9 3.29 25.7 3.26
0 28.1 2.94 27.8 2.91 27.5 2.88 27.3 2.85 27.0 2.82 26.7 2.79
7 27.5 2.45 27.3 2.42 27.0 2.40 26.7 2.38 26.5 2.35 26.2 2.33
24 35.8 2.82 35.5 2.79 35.1 2.76 34.7 2.73 34.4 2.71 34.1 2.68
NOTE
• The performance table shows the average value of each conditions.
31
2. Summary Table
360 Cassette
AC036MN4PKH/CB+AC036MXADKH/CB
Cooling
Outdoor 20 / 14 22 / 16 25 / 18 27 / 19 28 / 20 30 / 22 32 / 24
Temperature
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW
-15 33.3 27.8 2.43 35.0 28.7 2.48 36.5 29.6 2.53 37.6 30.5 2.58 38.4 30.2 2.61 40.3 29.9 2.64 42.3 29.3 2.69
21 31.7 26.5 2.56 33.4 27.3 2.61 34.8 28.1 2.67 35.8 29.0 2.72 36.5 28.7 2.75 38.4 28.4 2.77 40.3 27.9 2.83
35 30.2 25.2 3.20 31.8 26.0 3.27 33.1 26.8 3.33 34.0 27.6 3.38 34.8 27.4 3.43 36.5 27.1 3.47 38.4 26.5 3.54
46 25.7 24.4 2.88 27.0 25.1 2.94 28.1 25.9 3.00 29.0 26.7 3.06 29.6 26.4 3.09 31.1 26.2 3.12 32.6 25.6 3.18
50 19.6 19.4 2.56 20.7 20.0 2.61 21.5 20.7 2.67 22.2 21.3 2.72 22.6 21.1 2.75 23.8 20.9 2.77 24.9 20.4 2.83
Heating
Outdoor Temperature 16 18 20 21 22 24
TC PI TC PI TC PI TC PI TC PI TC PI
MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW
-20 26.9 4.18 26.6 4.14 26.4 4.10 26.1 4.05 25.8 4.01 25.6 3.97
-15 33.9 4.82 33.6 4.77 33.2 4.73 32.9 4.68 32.6 4.63 32.3 4.58
-5 38.2 4.50 37.8 4.45 37.5 4.41 37.1 4.37 36.7 4.32 36.3 4.28
0 39.8 3.86 39.4 3.82 39.0 3.78 38.6 3.74 38.2 3.70 37.8 3.67
7 39.0 3.21 38.6 3.18 38.0 3.12 37.8 3.12 37.5 3.09 37.1 3.06
24 50.7 3.70 50.2 3.66 49.7 3.62 49.2 3.59 48.7 3.55 48.2 3.51
NOTE
• The performance table shows the average value of each conditions.
32
2. Summary Table
360 Cassette
AC048MN4PKH/CB+AC048MXADKH/CB
Cooling
Outdoor 20 / 14 22 / 16 25 / 18 27 / 19 28 / 20 30 / 22 32 / 24
Temperature
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW
-15 41.0 33.8 2.55 43.1 34.9 2.60 44.9 35.9 2.65 46.3 37.0 2.71 47.2 36.7 2.73 49.6 36.3 2.76 52.1 35.6 2.81
21 39.0 32.2 2.68 41.1 33.2 2.74 42.8 34.2 2.79 44.1 35.3 2.85 45.0 34.9 2.88 47.2 34.6 2.90 49.6 33.9 2.96
35 37.2 30.7 3.35 39.1 31.6 3.42 40.7 32.6 3.49 42.0 33.6 3.56 42.8 33.3 3.60 45.0 32.9 3.63 47.2 32.3 3.70
46 31.6 28.5 3.02 33.2 29.3 3.08 34.6 30.2 3.14 35.7 31.2 3.20 36.4 30.9 3.24 38.2 30.6 3.27 40.1 29.9 3.33
50 24.2 22.4 2.68 25.4 23.1 2.74 26.5 23.8 2.79 27.3 24.6 2.85 27.8 24.3 2.88 29.2 24.1 2.90 30.7 23.6 2.96
Heating
Outdoor Temperature 16 18 20 21 22 24
TC PI TC PI TC PI TC PI TC PI TC PI
MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW
-20 37.2 6.35 36.9 6.29 36.5 6.23 36.1 6.16 35.8 6.10 35.4 6.04
-15 46.9 7.33 46.5 7.26 46.0 7.19 45.6 7.11 45.1 7.04 44.7 6.97
-5 52.9 6.84 52.4 6.77 51.8 6.71 51.3 6.64 50.8 6.57 50.3 6.51
0 55.0 5.86 54.5 5.81 54.0 5.75 53.4 5.69 52.9 5.63 52.4 5.58
7 54.0 4.89 53.4 4.84 52.9 4.79 52.4 4.74 51.8 4.69 51.3 4.65
24 70.2 5.62 69.5 5.56 68.8 5.51 68.1 5.45 67.4 5.40 66.7 5.34
NOTE
• The performance table shows the average value of each conditions.
33
4. Dimensional Drawing
360 Cassette
AC024MN4PKH/CB
Units : mm [inches]
NOTE
• As for suspension bolt, please use M8 ~ M10. (Procured at local site)
• Make sure the spacing between the ceiling and the cassette is more than 29mm[1-1/4].
Max ceiling opening : 960mm[37-13/16].
•
and additional insulation is required (polyethylene foam , thickness 10mm[3/8] or more)
34
4. Dimensional Drawing
360 Cassette
AC024MN4PKH/CB
Units : mm [inches]
NOTE
• As for suspension bolt, please use M8 ~ M10. (Procured at local site)
• Make sure the spacing between the ceiling and the cassette is more than 29mm[1-1/4].
Max ceiling opening : 960mm[37-13/16].
•
and additional insulation is required (polyethylene foam , thickness 10mm[3/8] or more)
• The circular panel is by default available in exposed installation.
Make inspection holes on the ceiling for easier installation and maintenance, as shown in the following table.
(The size of an inspection hole must be at least 450 mm x 450 mm.)
• A suspended ceiling structure can substitute for the inspection holes.
35
4. Dimensional Drawing
360 Cassette
AC036MN4PKH/CB
Units : mm [inches]
NOTE
• As for suspension bolt, please use M8 ~ M10. (Procured at local site)
• Make sure the spacing between the ceiling and the cassette is more than 29mm[1-1/4].
Max ceiling opening : 960mm[37-13/16].
•
and additional insulation is required (polyethylene foam , thickness 10mm[3/8] or more)
36
4. Dimensional Drawing
360 Cassette
AC048MN4PKH/CB
Units : mm [inches]
NOTE
• As for suspension bolt, please use M8 ~ M10. (Procured at local site)
• Make sure the spacing between the ceiling and the cassette is more than 29mm[1-1/4].
Max ceiling opening : 960mm[37-13/16].
•
and additional insulation is required (polyethylene foam , thickness 10mm[3/8] or more)
• The circular panel is by default available in exposed installation.
Make inspection holes on the ceiling for easier installation and maintenance, as shown in the following table.
(The size of an inspection hole must be at least 450 mm x 450 mm.)
• A suspended ceiling structure can substitute for the inspection holes.
37
5. Center of Gravity
360 Cassette
Units : mm [inches]
A B
AC024MN4PKH/CB 233 [9-3/16] 165 [6-1/2]
AC036/048MN4PKH/CB 317 [12-1/2] 220 [8-5/8]
38
6. Electrical Wiring Diagram
360 Cassette
2-LINE SUB PBA Printed Circuit Board(2-LINE SUB) SPI S-Plasma ion ROOM(10K) Thermistor ROOM OUT(10K)
M-BLDC BLDC Motor Electronic Expansion Valve Thermistor EVA IN(10K)
EXT CONTROL EXTERNAL_CONTROL Thermistor EVA OUT(10K)
Ventilator
NOTE
• This wiring diagram applies only to the Indoor unit.
• Symbols show as follow :
blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue: grn: green
• For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remote controller transmission F3-F4.
• Protective earth(screw), : connector, : The wire quantity
39
7. Sound Data
360 Cassette
Microphone
• NC Curve
1) AC024MN4PKH/CB 2) AC036MN4PKH/CB
70 70 70 70
65 65 65 65
NC 70
60 60 60 NC 65 60
NC 60
55 55 55 55
Sound Pressure Level (dB)
NC 60
NC 55 High
50 50 50 NC 55 50
NC 50 Low
45 45 45 NC 50 45
NC 45
40 40 40 40
NC 45
High NC 40
35 35 35 35
Low NC 40
NC 35
30 30 30 30
NC 35
NC 30
25 25 25 25
NC 30
20 NC 25 20 20 20
NC 25
NC 20 15 15
15 15 NC 20
NC 15 10 10
10 10
NC 15
5 5 5 5
0 0 0 0
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency(Hz) Octave Band Center Frequency(Hz)
3) AC048MN4PKH/CB
70 70
65 65
NC 70
60 60
NC 60
55 55
NC 55
50 High 50
NC 50
45 45
Low NC 45
40 40
NC 40
35 35
NC 35
30 30
NC 30
25 25
20 NC 25 20
15 NC 20 15
NC 15
10 10
5 5
0 0
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency(Hz)
NOTE
• Specifications may be subject to change without prior notice.
- Sound pressure level is obtained in an anechoic room.
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A weighted sound pressure level
-
40
8. Temperature and air flow distribution
360 Cassette
AC024MN4PKH/CB
41
8. Temperature and air flow distribution
360 Cassette
AC036MN4PKH/CB
42
8. Temperature and air flow distribution
360 Cassette
AC048MN4PKH/CB
43
Big Ceiling
1. Specification 46
2. Summary Table 48
3. Capacity Table 49
4. Dimensional Drawing 51
5. Center of Gravity 52
6. Electrical Wiring Diagram 53
7. Sound Data 54
8. Temperature and air flow distribution 55
44
Features & Benefits
Ceiling Type (large capacity) - Powerful cooling with a long distance wind
45
1. Specification
Big Ceiling
46
1. Specification
Big Ceiling
NOTE
• Specification may be subject to change without prior notice.
1) Capacities are based on (Equivalent refrigerant piping 5m, Level differences 0m);
- Cooling : Indoor temperature 27°C DB, 19°C WB / Outdoor temperature 35.0°C DB, 24°C WB
-
2) Select wire size based on the value of MCA
3) Sound pressure level is obtained in an anechoic room.
- Sound pressure level based on T1 condition (Indoor temperature 27°C DB, 19°C WB /
Outdoor temperature : 35°C DB, 24°C WB)
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A-weighted sound pressure level
- Reference acoustic pressure 0 dB = 20uPa
4) These products contain R410A which is fluorinated greenhouse gas.
• In case you want to know more information regarding capacity and correction, please refer to capacity table
TDB on pvi.samsung.com site.
47
2. Summary Table
Big Ceiling
Performance Characteristics
Capacity
Net Weight Airflow Sound Pressure Level
Model Code Cooling Heating Fan Speed
(kg) (CMM) (dBA)
(Btu/h) (Btu/h)
Max. 40,900 52,900 High 26.0 42
AC036MNCDKH/CB 41.4 Std. 34,100 38,200 Mid 23.0 38
Min. 10,200 7,500 Low 19.0 34
Max. 59,000 68,000 High 37.0 50
AC048MNCDKH/CB 41.4 Std. 44,000 52,900 Mid 31.0 47
Min. 14,700 16,000 Low 26.0 43
NOTE
• Sound data is based on cooling operation.
Electric Characteristics
NOTE
• MCA : Minimum circuit amperes
• MFA : Maximum fuse amperes
• Select wire size based on the value of MCA
48
3. Capacity Table
Big Ceiling
AC036MNCDKH/CB+AC036MXADKH/CB
Cooling
Outdoor 20 / 14 22 / 16 25 / 18 27 / 19 28 / 20 30 / 22 32 / 24
Temperature
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW
-15 33.3 25.7 2.43 35.0 26.5 2.48 36.5 27.4 2.53 37.6 28.2 2.58 38.4 27.9 2.61 40.3 27.7 2.64 42.3 27.1 2.69
21 31.7 24.5 2.56 33.4 25.3 2.61 34.8 26.1 2.67 35.8 26.9 2.72 36.5 26.6 2.75 38.4 26.3 2.77 40.3 25.8 2.83
35 30.2 23.4 3.20 31.8 24.1 3.27 33.1 24.8 3.33 34.1 25.6 3.40 34.8 25.3 3.43 36.5 25.1 3.47 38.4 24.6 3.54
46 25.7 22.8 2.88 27.0 23.5 2.94 28.1 24.2 3.00 29.0 24.9 3.06 29.6 24.7 3.09 31.1 24.4 3.12 32.6 24.0 3.18
50 19.6 18.2 2.56 20.7 18.8 2.61 21.5 19.4 2.67 22.2 20.0 2.72 22.6 19.8 2.75 23.8 19.6 2.77 24.9 19.2 2.83
Heating
Outdoor Temperature 16 18 20 21 22 24
TC PI TC PI TC PI TC PI TC PI TC PI
MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW
-20 26.9 4.24 26.6 4.20 26.4 4.16 26.1 4.12 25.8 4.08 25.6 4.04
-15 33.9 4.90 33.6 4.85 33.2 4.80 32.9 4.75 32.6 4.70 32.3 4.66
-5 38.2 4.57 37.8 4.52 37.5 4.48 37.1 4.44 36.7 4.39 36.3 4.35
0 39.8 3.92 39.4 3.88 39.0 3.84 38.6 3.80 38.2 3.76 37.8 3.73
7 39.0 3.26 38.6 3.23 38.2 3.20 37.8 3.17 37.5 3.14 37.1 3.10
24 50.7 3.75 50.2 3.72 49.7 3.68 49.2 3.64 48.7 3.61 48.2 3.57
NOTE
• The performance table shows the average value of each conditions.
49
3. Capacity Table
Big Ceiling
AC048MNCDKH/CB+AC048MXADKH/CB
Cooling
Outdoor 20 / 14 22 / 16 25 / 18 27 / 19 28 / 20 30 / 22 32 / 24
Temperature
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW
-15 42.9 35.4 2.67 45.2 36.5 2.72 47.1 37.6 2.78 48.5 38.8 2.83 49.5 38.4 2.86 52.0 38.0 2.89 54.6 37.3 2.95
21 40.9 33.7 2.81 43.0 34.8 2.87 44.8 35.9 2.92 46.2 37.0 2.98 47.1 36.6 3.01 49.5 36.2 3.04 52.0 35.5 3.10
35 38.9 32.1 3.51 41.0 33.1 3.58 42.7 34.1 3.66 44.0 35.2 3.73 44.9 34.8 3.77 47.1 34.5 3.80 49.5 33.8 3.88
46 33.1 29.8 3.16 34.8 30.7 3.22 36.3 31.7 3.29 37.4 32.7 3.36 38.1 32.3 3.39 40.1 32.0 3.42 42.1 31.4 3.49
50 25.3 23.5 2.81 26.6 24.2 2.87 27.7 25.0 2.92 28.6 25.7 2.98 29.2 25.5 3.01 30.6 25.2 3.04 32.2 24.7 3.10
Heating
Outdoor Temperature 16 18 20 21 22 24
TC PI TC PI TC PI TC PI TC PI TC PI
MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW
-20 37.2 5.90 36.9 5.84 36.5 5.79 36.1 5.73 35.8 5.67 35.4 5.61
-15 46.9 6.81 46.5 6.74 46.0 6.68 45.6 6.61 45.1 6.54 44.7 6.48
-5 52.9 6.36 52.4 6.29 51.8 6.23 51.3 6.17 50.8 6.11 50.3 6.04
0 55.0 5.45 54.5 5.39 54.0 5.34 53.4 5.29 52.9 5.23 52.4 5.18
7 54.0 4.54 53.4 4.49 52.9 4.45 52.4 4.41 51.8 4.36 51.3 4.32
24 70.2 5.22 69.5 5.17 68.8 5.12 68.1 5.07 67.4 5.02 66.7 4.97
NOTE
• The performance table shows the average value of each conditions.
50
4. Dimensional Drawing
Big Ceiling
AC036/048MNCDKH/CB
Units : mm [inches]
NOTE
• As for suspension bolt, please use M8 ~ M10.
(Procured at local site)
51
5. Center of Gravity
Big Ceiling
Units : mm [inches]
52
6. Electrical Wiring Diagram
Big Ceiling
MAIN PBA Printed Circuit Board(MAIN) SPI S-Plasma ion ROOM(10K) Thermistor ROOM OUT(10K)
Printed Circuit Board(BLDC DRIVER) Electronic Expansion Valve Thermistor EVA IN(10K)
SUB PBA Printed Circuit Board(SUB) EXT_CONTROL EXTERNAL_CONTROL Thermistor EVA OUT(10K)
M-BLDC BLDC Motor DISCHARGE(10K) Thermistor DISCHARGE(10K)
NOTE
• This wiring diagram applies only to the Indoor unit.
• Symbols show as follow :
blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue: grn: green
• For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remote controller transmission F3-F4.
• Protective earth(screw), : connector, : The wire quantity
53
7. Sound Data
Big Ceiling
1m
Model HIGH MID LOW
AC036MNCDKH/CB 42 38 34
AC048MNCDKH/CB 50 47 43
1m
Microphone
• NC Curve
1) AC036MNCDKH/CB 2) AC048MNCDKH/CB
70 70 70 70
65 65 65 65
NC 70
60 NC 65 60 60 60
High NC 60
55 55 55 55
Sound Pressure Level (dB)
NC 60
NC 55
50 NC 55 50 50 50
Hig h
NC 50
45 NC 50 45 45 Low 45
NC 45
40 40 40 40
Low NC 45 NC 40
35 35 35 35
NC 40 NC 35
30 30 30 30
NC 35 NC 30
25 25 25 25
NC 30
NC 25
20 20 20 20
NC 25
15 15 NC 20
15 15
NC 20
NC 15
10 10 10 10
NC 15
5 5 5 5
0 0 0 0
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency(Hz) Octave Band Center Frequency(Hz)
NOTE
• Specifications may be subject to change without prior notice.
- Sound pressure level is obtained in an anechoic room.
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A weighted sound pressure level
-
54
8. Temperature and air flow distribution
Big Ceiling (Ceiling Installation Only)
AC036MNCDKH/CB
55
8. Temperature and air flow distribution
Big Ceiling (Ceiling Installation Only)
AC048MNCDKH/CB
56
Outdoor Units
1. Summary Table 58
2. Dimensional Drawing 59
3. Center of Gravity 62
4. Electrical Wiring Diagram 64
5. Sound Data 66
6. Capacity Correction 67
7. Operation Range 70
8. Piping Diagram 71
57
1. Summary Table
Outdoor Units
Performance Characteristics
Capacity Net Size Net Weight Airflow Sound Pressure Level (dBA)
Model Code
(Btu/h) (WxHxD mm) (kg) (CMM) Cooling Heating
24,000 AC024MXADKH/CB 880 x 798 x 310 54.0 51.0 49.0 51.0
36,000 AC036MXADKH/CB 940 x 998 x 330 72.0 78.0 52.0 54.0
48,000 AC048MXADKH/CB 940 x 1420 x 330 98.0 112.0 56.0 56.0
58
2. Dimensional Drawing
Outdoor Units
AC024MXADKH/CB
Units : mm [inches]
59
1. Summary Table
Outdoor Units
AC036MXADKH/CB
Units : mm [inches]
60
1. Summary Table
Outdoor Units
AC048MXADKH/CB
Units : mm [inches]
61
3. Center of Gravity
Outdoor Units
AC024MXADKH/CB
Units : mm [inches]
AC036MXADKH/CB
Units : mm [inches]
62
3. Center of Gravity
Outdoor Units
AC048MXADKH/CB
Units : mm [inches]
63
4. Electrical Wiring Diagram
Outdoor Units
AC024MXADKH/CB
NOTE
• This wiring diagram applies only to the outdoor unit.
• Colors blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue
•
•
the installation manual.
• : connector, : The wire quantity
64
4. Electrical Wiring Diagram
AC036/048MXADKH/CB
NOTE
• This wiring diagram applies only to the outdoor unit.
• Colors blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue
•
•
the installation manual.
• : connector, : The wire quantity
65
5. Sound Data
Outdoor Units
Front Front
•
AC024MXADKH/CB AC036MXADKH/CB
90 90 90 90
85 85 85 NC 90 85
80 80 80 NC 85 80
75 75 75 NC 8 0 75
70 70 70 70
Sound Pressure Level (dB)
NC 75
65 65 65 NC 70 65
NC 70 60 Cooling
Heating 60
60 60 NC 65
Heating NC 60 55 55
55 55 NC 60
Cool ing NC 55 50 NC 55 50
50 50
NC 50 45 NC 50 45
45 45
NC 45 40 40
40 40 NC 4 5
NC 40 35 35
35 35 NC 40
NC 35 30 NC 35
30
30 30 25 25
NC 30 NC 30
25 25 20 20
20 NC 25 20 Hearing NC 25
15 15
15 Hearing NC 20 15 threshold NC 20
threshold 10 10
10 NC 15 10 NC 15
5 5
5 5 0 0
0 0 63 125 250 500 1000 2000 4000 8000
63 125 250 500 1000 2000 4000 8000 Octave Band Center Frequency(Hz)
Octave Band Center Frequency(Hz)
AC048MXADKH/CB
90 90
85 85
80 80
75 75
70 70
65 65
NC 70
60 Heating 60
Cooling NC 60
55 55
NC 55
50 50
NC 50
45 45
NC 45
40 40
NC 40
35 35
NC 35
30 30
NC 30
25 25
20 NC 25 20
15 Hearing NC 20 15
threshold NC 15
10 10
5 5
0 0
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency(Hz)
NOTE
• Specifications may be subject to change without prior notice.
Sound pressure level is obtained in an anechoic room.
Sound pressure level is a relative value, depending on the distance and acoustic environment.
Sound pressure level may differ depending on operation condition.
dBA = A weighted sound pressure level
66
6. Capacity Correction
Outdoor Units
AC024MXADKH/CB
Cooling
10 98 97 96 94 93 92 91 90
5 99 98 97 96 94 93 92 91 90
0 100 99 98 97 96 94 93 92 91 90
-5 98 97 96 95 94 93 92 91 89
-10 97 96 95 94 92 91 90 88
-15 95 95 93 92 91 89 88
-20 94 93 92 90 89 87
-25 92 91 90 88 86
-30 91 89 88 85
Heating
10 98 97 96 96 95 94 93 92
5 99 98 97 96 96 95 94 93 92
0 100 99 98 97 96 96 95 94 93 92
-5 99 98 97 96 96 95 94 93 92
-10 98 97 96 96 95 94 93 92
-15 97 96 96 95 94 93 92
-20 96 96 95 94 93 92
-25 96 95 94 93 92
-30 95 94 93 92
67
5. Sound Data
Outdoor Units
AC036MXADKH/CB
Cooling
10 98 97 96 94 93 92 91 90
5 99 98 97 96 94 93 92 91 90
0 100 99 98 97 96 94 93 92 91 90
-5 98 97 96 95 94 93 92 91 89
-10 97 96 95 94 92 91 90 88
-15 95 95 93 92 91 89 88
-20 94 93 92 90 89 87
-25 92 91 90 88 86
-30 91 89 88 85
Heating
10 98 97 96 96 95 94 93 92
5 99 98 97 96 96 95 94 93 92
0 100 99 98 97 96 96 95 94 93 92
-5 99 98 97 96 96 95 94 93 92
-10 98 97 96 96 95 94 93 92
-15 97 96 96 95 94 93 92
-20 96 96 95 94 93 92
-25 96 95 94 93 92
-30 95 94 93 92
68
5. Sound Data
Outdoor Units
AC048MXADKH/CB
Cooling
10 98 97 97 96 95 94 93 92 91 91 90 89 88
5 99 98 97 97 96 95 94 93 92 91 91 90 89 88
0 100 99 98 97 97 96 95 94 93 92 91 91 90 89 88
-5 99 98 97 96 95 95 94 93 92 91 90 89 88 87
-10 98 97 96 95 94 93 93 92 91 90 89 88 86
-15 97 96 95 94 93 92 91 90 89 88 87 85
-20 95 95 94 93 92 91 90 89 88 86 84
-25 94 93 93 92 91 90 89 87 86 83
-30 93 92 91 90 89 88 87 85 82
Heating
10 99 98 97 96 96 95 94 94 93 92 91 91 90
5 99 99 98 97 96 96 95 94 94 93 92 91 91 90
0 100 99 99 98 97 96 96 95 94 94 93 92 91 91 90
-5 99 99 98 97 96 96 95 94 94 93 92 91 91 90
-10 99 98 97 96 96 95 94 94 93 92 91 91 90
-15 98 97 96 96 95 94 94 93 92 91 91 90
-20 97 96 96 95 94 94 93 92 91 91 90
-25 96 96 95 94 94 93 92 91 91 90
-30 96 95 94 94 93 92 91 91 90
69
7. Operation Range
Outdoor Units
NOTE
• The assumed installation conditions are follows
70
8. Piping Diagram
Outdoor Units
Thermistor-
IDU Heat Thermistor-
Exchanger Mid IDU
(T_IM) Heat
Exchanger
IN
(T_II)
Service
Valve-
Gas Pipe Heat Exchanger -
(SV_G) Indoor unit
(HX_ID)
Indoor
Fan Motor
(IFM)
Outdoor Fan Motor1 (OFM1)
Electronic Thermistor-
Expansion Valve- Indoor Room
Main1 (T_IR)
(E_M1)
Thermistor-
Ambient Heat Exchanger -
(T_A) Thermistor- Service
Main(Outdoor unit) Cond Out Valve-
(HX_M) (T_A) Liquid Pipe
(SV_L)
Solenoid valve -
4Way
(V_4W)
Accumulator
(AC)
Thermistor-
Thermistor- Discharge
Compressor pipe
Top (T_D)
(T_CT)
Compressor
(COMP)
71
7. Operation Range
Outdoor Units
Thermistor-
IDU Heat Thermistor-
Exchanger Mid IDU
(T_IM) Heat
Exchanger
IN
(T_II)
Service
Valve-
Gas Pipe Heat Exchanger -
(SV_G) Indoor unit
(HX_ID)
Indoor
Fan Motor
(IFM)
Outdoor Fan Motor1 (OFM1)
Electronic Thermistor-
Expansion Valve- Indoor Room
Main1 (T_IR)
(E_M1)
Thermistor-
Ambient Heat Exchanger -
(T_A) Thermistor- Service
Main(Outdoor unit) Cond Out Valve-
(HX_M) (T_A) Liquid Pipe
(SV_L)
Solenoid valve -
4Way
(V_4W)
Accumulator
(AC)
Thermistor-
Thermistor- Discharge
Compressor pipe
Top (T_D)
(T_CT)
Compressor
(COMP)
72
7. Operation Range
Outdoor Units
AC036MNCDKH/CB + AC036MXADKH/CB
Thermistor-
IDU Heat Thermistor-
Exchanger Mid IDU
(T_IM) Heat
Exchanger
IN
(T_II)
Service
Valve-
Gas Pipe Heat Exchanger -
(SV_G) Indoor unit
(HX_ID)
Thermistor-
Indoor Room
(T_IR)
Outdoor Fan Motor1 (OFM1)
Electronic
Expansion Valve-
Main1 Indoor Fan Motor
(E_M1) (IFM)
Thermistor-
Ambient Heat Exchanger -
(T_A) Thermistor- Service
Main(Outdoor unit) Cond Out Valve-
(HX_M) (T_A) Liquid Pipe
(SV_L)
Solenoid valve -
4Way
(V_4W)
Accumulator
(AC)
Thermistor-
Thermistor- Discharge
Compressor pipe
Top (T_D)
(T_CT)
Compressor
(COMP)
73
7. Operation Range
Thermistor-
IDU Heat Thermistor-
Exchanger Mid IDU
(T_IM) Heat
Exchanger
IN
(T_II)
Service
Valve-
Gas Pipe Heat Exchanger -
(SV_G) Indoor unit
(HX_ID)
Indoor
Fan Motor
(IFM)
OutdoorFanMotor1 (OFM1) OutdoorFanMotor2 (OFM2)
Thermistor-
Electronic Indoor Room
Expansion Valve- (T_IR)
Main1 (E_M1)
Thermistor-
Ambient Heat Exchanger -
(T_A) Thermistor- Service
Main(Outdoor unit) Cond Out Valve-
(HX_M) (T_A) Liquid Pipe
(SV_L)
Solenoid valve -
4Way
(V_4W)
Accumulator
(AC)
Thermistor-
Thermistor- Discharge
Compressor pipe
Top (T_D)
(T_CT)
Compressor
(COMP)
74
7. Operation Range
AC048MNCDKH/CB + AC048MXADKH/CB
Thermistor-
IDU Heat Thermistor-
Exchanger Mid IDU
(T_IM) Heat
Exchanger
IN
(T_II)
Service
Valve-
Gas Pipe Heat Exchanger -
(SV_G) Indoor unit
(HX_ID)
Thermistor-
Indoor Room
(T_IR)
OutdoorFanMotor1 (OFM1) OutdoorFanMotor2 (OFM2)
Electronic
Expansion Valve- Indoor Fan Motor
Main1 (E_M1) (IFM)
Thermistor-
Ambient Heat Exchanger -
(T_A) Thermistor- Service
Main(Outdoor unit) Cond Out Valve-
(HX_M) (T_A) Liquid Pipe
(SV_L)
Solenoid valve -
4Way
(V_4W)
Accumulator
(AC)
Thermistor-
Thermistor- Discharge
Compressor pipe
Top (T_D)
(T_CT)
Compressor
(COMP)
75
Installation
1. 4 Way Cassette
CAUTION
• You must install all of the suspension rods.
• It is important to leave sufficient space in the false ceiling to allow
access for maintenance or repairs to the drainage pipe connection, the
refrigerant pipe connection, or to remove the unit if necessary.
5 Hang the indoor unit to the suspension bolts between two nuts. Cut a
NOTE pad stopper and place it on the suspension bolts to hold the washers.
• Since the diagram is made of paper, it may shrink or stretch slightly due Remove the stopper and screw the nuts to fix the unit.
to temperature or humidity. For this reason, before drilling the holes, be
sure to maintain the correct dimensions between the markings.
6 Adjust the unit to the appropriate position, taking into account the
installation area for the front panel.
76
Installation
1. 4 Way Cassette
3 Wrap the supplied large sealing pad over the metal clamp and drain • If it is necessary to increase the height of the drain pipe, install the drain
hose to insulate and fix it with clamps. pipe straight within 300 mm from the drain hose port. If it is raised
higher than 550 mm, there may be water leaks.
4 Insulate the complete drain piping inside the building (field supply).
If the drain hose cannot be sufficiently set on a slope, fit the hose with
drain raising piping (field supply).
5 Push the drain hose up to insulation when connecting the drain hose to
drain socket.
• Do not give the hose an upward gradient beyond the connection port.
This will cause water to flow backwards when the unit is stopped,
resulting in water leaks.
77
Installation
1. 4 Way Cassette
• Do not apply force to the piping on the unit side when connecting the • Max. allowable axis gap.
drain hose. The hose should not be allowed to hang loose from its
connection to the unit. Fasten the hose to a wall, frame or other support
as close to the unit as possible.
• Install horizontally.
NOTE
• If a concentrated drain pipe is installed, refer to the figure below.
78
Installation
1. 4 Way Cassette
1 Remove the screw on the electrical component box and remove the cover
plate.
Tightening torque (kgf • cm)
2 Route the connection cord through the side of the indoor unit and
connect the cable to the terminals refer to the figure below. M3.5 8.0 to 12.0
3 Route the other end of the cable to the outdoor unit through the ceiling & M4 12.0 to 18.0
the hole on the wall.
• 1 N·m = 10 kgf·cm
4 Reassemble the electrical component box cover, carefully tightening the
screw. • Power supply cords of parts of appliances for outdoor use shall not be
lighter than polychloroprene sheathed flexible cord. (Code designation
IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC:
1 phase H07RN-F)
• Since it has the external power supply, refer to the outdoor unit
installation manual for MAIN POWER.
CAUTION
• When installing the indoor unit in a computer room or network room,
use the double shielded communication cable (tape aluminum /
polyester braid + copper) of FROHH2R type.
79
Installation
2. 360 Cassette
Installing the indoor unit b For recessed installation of the circular panel
• Install inspection holes to both directions of the connection part
When deciding on the location of the air conditioner the following of the refrigerant pipe and the drain hose and of the indoor unit
restrictions must be taken into account. display.
(2 points)
1 Determine the positions of the pipe and the drain hose hole as shown in
the pattern sheet, and drill the hole with an inner diameter of 14 mm.
NOTE
• Since the diagram is made of paper, it may shrink or stretch slightly due
to temperature or humidity. For this reason, before drilling the holes, be
sure to maintain the correct dimensions between the markings.
2 Perform the following steps to install inspection holes in accordance
with the panel type.
CAUTION
• Make sure that the ceiling is strong enough to support the weight of the
indoor unit. Before hanging the unit, test the strength of each attached
suspension bolt.
• If the length of the suspension bolt is more than 1.5 m, you are required
to prevent vibration.
5 Screw eight pairs of nuts and washers to the suspension bolts, making
space for hanging the indoor unit.
80
Installation
2. 360 Cassette
3 Wrap the supplied large sealing pad over the metal clamp and drain hose
to insulate and fix it with clamps.
4 Insulate the complete drain piping inside the building (field supply).
If the drain hose cannot be sufficiently set on a slope, fit the hose with
drain raising piping (field supply).
7 Adjust the unit to the appropriate position, taking into account the 5 Push the drain hose up to insulation when connecting the drain hose to
installation area for the front panel. drain socket.
• Place the pattern sheet on the indoor unit.
• Adjust the space between the ceiling and the indoor unit by using a
dimension gauge.
• Fix the indoor unit securely after adjusting the level of the unit by
using a leveller.
• Remove the pattern sheet, connect the other cables. and install the
front panel.
CAUTION
Check that the indoor unit is level with the ceiling by using the leveller.
• Install air ventilation to drain condensation smoothly.
81
Installation
2. 360 Cassette
• Install horizontally.
• If it is necessary to increase the height of the drain pipe, install the drain
pipe straight within 300 mm from the drain hose port. If it is raised
higher than 550 mm, there may be water leaks.
• Do not give the hose an upward gradient beyond the connection port.
This will cause water to flow backwards when the unit is stopped,
resulting in water leaks.
• Do not apply force to the piping on the unit side when connecting the
drain hose. The hose should not be allowed to hang loose from its
connection to the unit. Fasten the hose to a wall, frame or other support
as close to the unit as possible. NOTE
• If a concentrated drain pipe is installed, refer to the figure below.
82
Installation
2. 360 Cassette
cables • Insert the power and the communication cables to the cable insert hole,
then arrange and connect the cables, as shown in the figure:
CAUTION
• Always remember to connect the refrigerant pipes before performing the
electric connections.
When disconnecting the system, always disconnect the electric cables
before disconnecting the refrigerant pipes.
• Always remember to connect the air conditioner to the grounding system
before performing the electric connections. Use a crimp ring terminal at
the end of each wire.
The indoor unit is powered through the outdoor unit by means of a H07
RN-F connection cable (or a more power model), with insulation in synthetic
rubber and a jacket in polychloroprene (neoprene), in accordance with the
requirements specified in the standard EN 60335-2-40.
1 Remove the screw on the electrical component box and remove the cover
plate.
2 Route the connection cord through the side of the indoor unit and
connect the cable to the terminals refer to the figure below.
3 Route the other end of the cable to the outdoor unit through the ceiling &
the hole on the wall.
Communication cable
83
Installation
2. 360 Cassette
M4 12.0 to 18.0
• 1 N·m = 10 kgf·cm
• Power supply cords of parts of appliances for outdoor use shall not be
lighter than polychloroprene sheathed flexible cord. (Code designation
IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC:
H07RN-F)
• Since it has the external power supply, refer to the outdoor unit
installation manual for MAIN POWER.
CAUTION
• When installing the indoor unit in a computer room or network room, use
the double shielded communication cable (tape aluminum / polyester
braid + copper) of FROHH2R type.
84
Installation
3. Big Ceiling
Ceiling installation
CAUTION
1 Select pipe directions. • Ensure that the ceiling is strong enough to support the weight of the
indoor unit.
When the directions are selected, drill 3-1/8''-(100mm, for pipe and
cables) and 1-3/4''-(40mm, for drain hose) diameter holes on the wall so • Before hanging the unit, test the strength of each attached suspension
that it slants slightly downwards toward the outdoor for smooth water bolt.
flow. • Install the drain hose from the rear of the unit.
NOTE NOTE
• Use the template to select pipe directions. • The gap between the lower end of the indoor unit and the ceiling should
2 Drill holes for anchor bolts according to the distance and mount them.
4 When Hanging the set, firstly unscrew the screws from the both of
NOTE sides, and then disassemble the Case-sides, or else the case-side will be
damaged by disassembling it directly.
• Use the template.
3 Install the unit onto the ceiling. Be sure to arrange the drain hose so that
it is leveled lower than the drain hose connecting port of the indoor unit.
NOTE
• For proper drainage of condensate, give a 2° (The gap between the lower Unscrew two screws from the both of sides.
the side of the unit which will be connected with the drain hose as shown 5 Reassemble the Case-sides, tightening the screws after hanging the set.
in the figure.
2°
Connection pipe
Drain hose
Connection pipe
Remove the Case-sides from the both of sides.
Drain hose
85
Installation
3. Big Ceiling
Care must be taken when installing the drain hose for the indoor unit to hole
NOTE
• Installing the drain hose should be the shorter, the better.
• In order to discharge condensate water, a downward gradient should be No grade
maintained.
• Fix the drain hose with Cable-Tie, so that it will not separate from the
machine.
2 Lock flexible hose clamp of the drain hose according to the figure.
3 Wind and wrap flexible hose clamp and drain hose fully with thermal
insulation sponge; fix both ends of external layer with ribbon for thermal
insulation.
No slack No in the water water
4 After being installed, drain hose must be insulated fully by heat
insulating material. (To be provided at site.)
A A-A’ CAUTION
Drain hose
Wrap thermal sleeve hose • Always remember to connect the air conditioner to the grounding system
before performing the electric connections. Use a crimp ring terminal at
the end of each wire.
The indoor unit is powered through the outdoor unit by means of a H07
RN-F connection cable (or a more power model), with insulation in synthetic
rubber and a jacket in polychloroprene (neoprene), in accordance with the
requirements specified in the standard EN 60335-2-40.
1 Remove the screw on the electrical component box and remove the
cover plate.
2 Route the connection cord through the side of the indoor unit and
connect the cable to the terminals refer to the figure below.
3 Route the other end of the cable to the outdoor unit through the ceiling &
the hole on the wall.
86
Installation
3. Big Ceiling
1 phase
Tightening torque (kgf • cm)
• 1 N·m = 10 kgf·cm
1(L) 2(N) 1 2 F1 F2 V1 V2 F3 F4 • Power supply cords of parts of appliances for outdoor use shall not be
lighter than polychloroprene sheathed flexible cord. (Code designation
IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC:
H07RN-F)
1(L) 2(N) L N F1 F2 • Since it has the external power supply, refer to the outdoor unit
installation manual for MAIN POWER.
Cable
clamp
CAUTION
Indoor Power Main power cable Communication • When installing the indoor unit in a computer room or a server room,
cable use the double shielded communication cable (tape aluminum /
polyester braid + copper) of FROHH2R type.
Communication cable
0.75mm2
11 13 7.5 9.0
87
Installation
4. Outdoor Unit
CAUTION
• Depending on the condition of power supply, unstable power or voltage
may cause malfunction of the parts or control system. (At the ship or
places using power supply from electric generator...etc)
• Install the unit in a place where water can drain smoothly.
• If you have any difficulty finding installation location as prescribed above,
• Install the unit at a height where its base can be firmly fixed in place.
contact your manufacturer for details.
• Make sure that the water dripping from the drain hose runs away
correctly and safely. • Be sure to clean the sea water and the dust on the heat exchanger of the
outdoor unit and apply a corrosion inhibitor on it. (At least once in a year.)
88
Installation
4. Outdoor Unit
B Type
AC036MXADKH
C Type
AC048MXADKH
89
Installation
4. Outdoor Unit
• Louver specifications.
Angle criteria : less than 20°
Opening ratio criteria : greater than 80%
1 Before carrying the outdoor unit, fasten two wire ropes of 8 m or longer,
as shown in the figure.
CAUTION
• The outdoor unit must be installed according to the specified distances
in order to permit accessibility from each side, to guarantee correct
operation, maintenance, and repair of the unit.
The components of the outdoor unit must be reachable and removable
under safe conditions for people and the unit.
90
Installation
4. Outdoor Unit
Fixing the outdoor unit in place Optional: Fixing the outdoor unit to a wall with a rack
Install the outdoor unit on a rigid and stable base to prevent disturbance
from any noise caused by vibration. When installing the unit at a height or in
a location exposed to strong winds, fix the unit securely to a support (i.e., a
wall or a ground).
Fix the outdoor unit with anchor bolts. Make sure that the anchor bolts are
20 mm or higher from the base surface.
CAUTION
• When installing an air guide duct, be sure to check the following:
The screws do not damage the copper pipe.
The air guide duct is fixed firmly on the guard fan.
CAUTION
• Install a drain outlet at the lowest end around the base for outdoor unit
drainage
• When installing the outdoor unit on the roof, waterproof the unit and
check the ceiling strength.
• Make sure that the wall can support the weights of the rack and the
outdoor unit.
• Install the rack close to the column as much as possible.
91
Installation
4. Outdoor Unit
You must connect the following three electrical cables to the outdoor unit:
• The main power cable between the auxiliary circuit breaker and the
outdoor unit.
• The outdoor-to-indoor power cable between the outdoor unit and the
indoor unit.
• The communication cable between the outdoor unit and the indoor unit.
CAUTION
• During installation, make first the refrigerant connections and then
the electrical connections. If the unit is uninstalled, first disconnect the
electrical cables and then the refrigerant connections.
• Connect the air conditioner to the earthing system before making the
electrical connections.
ELCB
1
NOTE
• Especially, if your outdoor unit is the one designed for Russian and
European markets, consult the supply authority, if necessary, to estimate
and reduce the supply system impedance before installation.
CAUTION
• If the outdoor unit is installed in a location vulnerable to an electric leak
or submergence, make sure to install an ELCB.
92
Installation
4. Outdoor Unit
1(L) 2(N) L N
93
Installation
4. Outdoor Unit
94
Installation
4. Outdoor Unit
Single phase
Indoor unit Outdoor unit Hz Volts Min. Max. Cooling Heating Indoor unit Total MCA MFA
AC024MN4DKH/CB 60 220-240 198 264 20 20 1.0 21.0 21.0 25.0
AC024MXADKH/CB
AC024MN4PKH/CB 60 220-240 198 264 20 20 1.5 21.5 21.5 25.0
AC036MN4PKH/CB 60 220-240 198 264 24 24 1.5 25.5 25.5 30.0
AC036MN4DKH/CB AC036MXADKH/CB 60 220-240 198 264 24 24 1.0 25.0 25.0 30.0
AC036MNCDKH/CB 60 220-240 198 264 24 24 2.0 26.0 26.0 30.0
AC048MN4PKH/CB 60 220-240 198 264 32 32 1.5 33.5 33.5 40.0
AC048MN4DKH/CB AC048MXADKH/CB 60 220-240 198 264 32 32 1.0 33.0 33.0 40.0
AC048MNCDKH/CB 60 220-240 198 264 32 32 2.0 34.0 34.0 40.0
NOTE
1 Voltage range 4 MFA is used to select the circuit breaker and the ground fault circuit
• Units are suitable for use on electrical systems where voltage interrupter (earth leakage circuit breaker).
supplied to unit terminal is not below or above listed range limits 5 MCA represents maximum input current.
2 Maximum allowable voltage variation between phases is 2%.
• MFA represents capacity which may accept MCA
3 Wire size & type must comply with the applicable local and national code. • Abbreviations
• Wire size: Based on the value of MCA. MCA: Min. Circuit Amps. (A)
• Wire type: 60245 IEC57(IEC) or H05RN-F(CENELEC) grade or more. MFA: Max. Fuse Amps. (A)
95
Installation
4. Outdoor Unit
L1
L0
Minimum thickness
Outer diameter [mm] Temper grade
[mm]
ø6.35 0.7
ø9.52 0.7
C1220T-O
ø12.70 0.8
ø15.88 1.0
• The appearance of the unit may be different from the diagram depending
ø15.88 0.8 on the model.
C1220T-1/2H OR
ø19.05 0.9
C1220T-H
ø22.23 0.9 CAUTION
• After connecting the pipes with knock-out treatment, plug the space
CAUTION around the pipes.
• Be sure to use C1220T-1/2H (Semi-hard) pipe for more than Ø19.05 mm. • After connecting the pipes, proceed exactly as directed in the guide to
If you use C1220T-O (Soft) pipe for Ø19.05 mm, the pipe may be broken, prevent interference with the internal parts.
which can result in an injury.
96
Installation
4. Outdoor Unit
n=1 n=3 L2
indoor indoor
L1
L1 L3 D
h1 indoor h2 h1
D
L4
outdoor indoor
outdoor
L2 L2
indoor indoor
n=2 L1 n=4 a
h2 L 3
D L1 indoor D
h1 L4 h2 h1
indoor indoor D
L3
b L5 indoor
outdoor outdoor
97
Accessory
Controller
Intergrated
Management MIM-D01AN
DMS 2.5
System MIM-D01AUN
S-NET 3 MST-P3P
MIM-B17BN
BACnet G/W
MIM-B17BUN
MIM-B18BN
LONWORKS G/W
MIM-B18BUN
Buiding
Management
System
PIM
MIM-B16N
(Pulse Interface Module)
SIM
MIM-B12N
(Signal Interface Module)
MIM-H03N
Wi-Fi Kit
MIM-H03UN
98
Accessory
Controller
MWR-WE10N
S-Converter MIM-C02N
• In case you want more information about the accessories, please refer to the control and accessories TDB on
pvi.samsung.com site.
99
Accessory
Indoor Unit’s Accessory
100
Accessory
Indoor Unit’s Accessory
Motion detect
MCR-SMA 4 Way Cassette(600 x 600)
Sensor
Drain Pump
MDP-G075SP Duct S (External)
• In case you want more information about the accessories, please refer to the control and accessories TDB on
pvi.samsung.com site.
101
2018. 09
Ver.1.2
Samsung Electronics Co., LTD.
B2B PM / SE
Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 16677
Website : www.samsung.com, http://btsp.samsunggsbn.com Email : airconditioner@samsung.com
Images and data in this book may subject to change without prior notice.