2009 International Conference on Energy and Environment Technology

The experimental research and analysis of the reverse osmosis technology on the
waste water reusing of the plant cooling water

Shuguo Zhang Dong Li, Guohong Wu, Huawei Jiang


School of Environmental Science and Engineering School of Energy and Power Engineering
North China Electric Power University North China Electric Power University
Baoding, People’s Republic of China Baoding, People’s Republic of China
e-mail:naikoo@126.com e-mail:naikoo@126.com

Abstract—This paper studied the influence of the feed circulating water. And economic analysis was carried out,
water PH value on the reverse osmosis system in the process of the operating parameters were optimized by which.
the sewage reusing of the power plant circulating water. The
utmost recovery rate was made out through experiments, at II. THE INFLUENCE OF FEED WATER PH VALUE ON THE
different feed water PH value, on condition that the RECOVERY RATE OF THE REVERSE OSMOSIS
concentrated water did not scale. The influence of the PH
value on the salt desalting rate of the reverse osmosis system A. Principle of experiment
was investigated, the results show that the highest desalination
Reverse osmosis membrane divides the water into two
rate is up to 99.6%, when the PH value is 8.0~9.0. Comparing
the different operating cost in different operating conditions,
parts, the permeate water and the concentrated water. The
it’s found that when the PH value is 8.0, the reverse osmosis ion concentration of the permeate water is very low, which
systematic recovery rate is 72%, which is the most economical tends to 0. If the insoluble salt in concentrated water does
operating condition. not scale on the membrane, the substances concentration
factor KM is equal to the volume concentration factor KV as
Keywords-reverse osmosis; circulating water of power plant; Formula (1)-(3) show, and when substances concentration
recovery rate; desalting rate; feed water PH value factor of certain insoluble salt KM<KV, the insoluble salt will
scale on the membrane.
I. INTRODUCTION Qf 1
Circulating water system accounts for more than 70% of KV = = (1)
Qf − Qc 1 − R
the water consumption of the power plant, and the drainage
of circulating water is about 20%~30% [1]. Reuseing the
waste water can save water resources, reduce waste water 1
discharge and achieve social and economic benefits [2].
Concentration ratio of circulating water of power plant is Cc Qc Qf
KM = = = (2)
about 3~4, so the salinity of circulating water is comparably Cf 1 Qf − Qc
higher, so desalting treatment is need for the water recycling.
What the process currently use is pre-treatment-reverse
Qf
osmosis system [3-5].
In the Large-scale reverse osmosis system, the water
route is very long and the membrane components are many. 1
So the insoluble salt of the concentrated water scales on the KM = (3)
1− R
surface of the membrane, which is the main factor of the
constraints to improve the recovery rate of reverse osmosis The experiments test the concentration changes of
system [6]. The recovery rate of reverse osmosis system
insoluble salt ions(Ca2+, Mg2+, SO42-and active silica)of
directly relates to the water and energy cost, so the system
design must be based on the quality of raw water and the concentrated water at the range of different PH value,
determine the best recovery of the reverse osmosis system. using the valume concentration factor and chloride ion
Because the solubility of some insoluble salts such as substances concentration factor as the reference
CaCO3, Mg (OH)2, and active silica is related with the PH standard(since the chloride ion does not scale on the
value. Besides, the change of the feed water PH value will membrane), determine the relevant recovery rate as the
affect the desalting rate of reverse osmosis [7], which has limited recovery rate when there is scaling on the membrane.
certain influence on the post-treatment operating cost. B. Water of experiment
In this paper, experiments were carried out targeting the
The drainage of circulating water was from one plant of
influence of the PH value of feed water on the recovery rate
ShanXi , the analysis of the water shown as table 1. The total
and desalination rate of the reverse osmosis system in the circulating water flow of the power plant is 8×104 t/h, the
process of the waste water reusing of the power plant

978-0-7695-3819-8/09 $26.00 © 2009 IEEE 843


DOI 10.1109/ICEET.2009.442
sewage flow is 200 t/h. As can be seen from Table 1 the Figure 1. When PH=6.0 the concentration factor at various recovery
water has the following characteristics: rate
(1)The water contain a certain amount of suspended 5
solids, small particles and turbidity.

Concentration factor
4
(2)Open cycle cooling water systems is the evaporative
cooling. In continuous production, with the continuous 3
improvement of concentration, the concentration of 2
insoluble salt ions as Ca2+, Mg2+, HCO3-, SO42- and the 1
active silicon became larger.
0
45 50 55 60 65 70 75 80
TABLE I. ANALYSIS OF THE RAW WATER
Rcovery rate/ %
Item Numerical Item Numerical Valume Magnesium Calcium
Values Values Chloride Sulfate Active silica
+ 3-
Na /(mg/ L) 333.98 PO4 /(mg/ L) 1.32

K+/(mg/ L) 6.65 PH 9.0

Ca /(mg/ L) 2+
113.23 Hardness of water 13.9 Figure 2. When PH=7.0 the concentration factor at various recovery
/(mmol/ L) rate
2+
Mg /(mg/ L) 100.24 Total solid content/ 1749.4
(mg/ L)
Ba2+/(mg/ L) 0.32 Total dissolved 1741.4 5
solids/(mg/L) 4.5

Concentration factor
Cl /(mg/ L) -
315 Suspended solids/ 8.2 4
(mg/ L) 3.5
3
SO42-/(mg/ L) 503 Active silica/ 62.3
2.5
(mg/ L) 2
CO32-/(mg/ L) 75 Colloidal silica/ ( 5.52 1.5
mg/L) 1
HCO3-/(mg/ L) 372 CODMn/(mg/ L) 4.91 0.5
0
NO3-/(mg/ L) 0.01 Conductivity/ ( 2255 45 50 55 60 65 70 75 80
μS/ cm) Rcovery rate/ %
Valume Magnesium Calcium
Chloride Sulfate Active silica

Figure 3. When PH=8.0 the concentration factor at various recovery


C. Experimental result rate
The change of the substances concentration factor of the
concentrated water ion and volume concentration factor with
3
the recovery rate increases gradually at different PH value
Concentration factor

was measured. 2.5


2
5
1.5
Concentration factor

4
1
3 0.5

2 0
40 45 50 55 60
1
Recovery rate/ %
0 Valume Magnesium Calcium
45 50 55 60 65 70 75 80 Chloride Sulfate Active silica
Recovery rate/ %
Valume Magnesium Calcium Figure 4. When PH=9.0 the concentration factor at various recovery rate
Chloride Sulfate Active silica
When PH=6.0, before the recovery rate≤78%, all kinds
of insoluble salt ion concentration factor, the concentration
of chloride ion concentration factor and volume
concentration factor is very close. From78%, the
concentration factor of active silica significantly deviate,
active silica begin scaling in membrane. So when PH=6.0,
the system recovery rate should be controlled as 78%.
When PH=7.0, before the recovery rate≤75%, all kinds
of insoluble salt ion concentration factor, the concentration

844
of chloride ion concentration factor and volume Figure 5. The desalination rate of the various ions of the single film at
concentration factor is very close. From75%, the different feed water PH.
concentration factor of active silica significantly deviates,
active silica begin scaling in membrane. So when PH=7.0 Desaling rate/ %
the system recovery rate should be controlled as 75%. 120 99
When PH=8.0, before the recovery rate≤72%,all kinds Produced water TDS Desalting rate
100 98
of insoluble salt ion concentration factor, the concentration
of chloride ion concentration factor and volume

TDS/ (mg/ L)
80 97
concentration factor is very close. From 72%, the
concentration factor of Ca2+ begin significantly deviate, Ca2+ 60 96
begin scaling in membrane. So when PH=8.0the system
40 95
recovery rate should be controlled as 72%.
When PH=9.0, before the recovery rate≤50%, all kinds 20 94
of insoluble salt ion concentration factor, the concentration
0 93
of chloride ion concentration factor and volume
1 2 3 4
concentration factor is very close. From 50%,the
concentration factor of Ca2+ begin significantly deviate, Ca2+ Figure 6. The TDS and total water desalination rate at four operating
begin scaling in membrane. So when PH=9.0, the system conditions
recovery rate should be controlled as 50%.
Fig5 shows the desalination rate of the various ions of
III. THE INFLUENCE OF FEED WATER PH VALUE ON THE the single film at different feed water PH. Before the
DESALINATION RATE OF THE REVERSE OSMOSIS PH<8.0, along with gradually increasing of the PH, the
desalination rate of various ions increase; When PH stays
A. Method of experiment between 8.0 to 9.0, various ions get the highest desalination
Removal of salt is the central purpose of reverse osmosis rates, among which the lowest is K+, 96.8%, the highest is
system, desalination rate is one of the main technical SO42-, 99%; When the PH>9.0, various ions’ desalination
parameters of system design and operation. Different PH rate decreases along with the PH increases.
values have certain effects on the single film desalinization Fig6 shows the the TDS and total water desalination rate
rate of reverse osmosis. In addition,the improving of the at four operating conditions. With the increase of feed water
recovery rate would mean reducing consumption of water, PH, the recovery rate decreases, so in four operating
so the improvement of the recovery rate would lead to a conditions, desalination rate of various ions increases along
lower level of system desalination [6], so PH changes in with the PH much more obviously than single-rate
water supply system caused a more complex impact on system.When the water PH=6.0, recovery rate is 78%, the
reverse osmosis desalination rate. This thesis research the desalination system is 94.7%,when the water PH=7.0, the
influence of the feed water PH on the reverse osmosis recovery rate is 75%,the desalination system is 95.9%.
desalination rate through the following two different When the water PH=8.0, the recovery rate is 72%, the
experiments. desalination rate is 96.7%, when the water PH=9.0, the
(1)Test the desalination rate of various ions in water recovery rate is 50%, the desalination rate is 98.0%.
samples when the recovery rate of the single film is 15%.
IV. ECONOMIC ANALYSIS OF DIFFERENT OPERATING
(2)Test the desalination rate of the water in the following
CONDITIONS
4 operating conditions: When PH=6.0, the recovery rate is
78%; PH=7.0, recovery rate is 75%; PH=8.0 recovery rate is
A. Running costs
75%; PH=9.0, recovery rate is 50%.
Economic analysis compares the running cost of the 4
B. Experimental Result operating conditions in 1hour, When PH=6.0, the recovery
rate is 78%; PH=7.0, recovery is 75%;PH=8.0, the recovery
100 rate is 72%; PH=9.0, the recovery rate is 50%, including the
Desalination ratio/ %

99
98
cost of water, acid costs,energy cost,and post-processing
97 cost.
96 1)Water cost. The water resource of the plant is
95
94
industrial water. Therefore, the improvement of recovery
93 rate of reverse osmosis system will save the cost of
92 industrial water supply. Price of industrial water is 2.7
91
5 6 7 8 9 10
yuan/t, the cost of water, when the PH=9.0, the recovery rate
PH
is 50%, is set to 0.
Potassium Sodium Magnesium Calcium 2)Acid cost.Reverse osmosis pretreatment use 31% HCl
Chloride Sulfate Active silica adjust the water PH. Acid price is 600 yuan/t.
3)Energy cost. Electricity cost is 0.7 yuan/KWh,
electricity consumption is calculated as formula (5) [8].

845
Pe=ρ gqvH (5) SYMBOLS
KV --- Volume concentration factor
4)Regeneration of resin in the post-processing
cost.Formulas (6) quote from document [9]. KM --- Substances concentration factor

ECH • b Qf --- Feed water flow rate


GHCL= (6)
1000ε Qc --- Concentrated water flow rate

B. Economic contrast CC --- Feed water consistency,mg/L


The comparision of the the four different operating
conditions cost in 1 hour shows in Table3. Cf --- Concentrated water consistency,mg/L

TABLE II. THE COMPARISION OF THE COST OF DIFFERENT OPERATING R --- Recovery rate
CONDITIONS

Item Operating Operating Operating Operating Pe ---Effective power of the high pressure pump ,W
Water
condition 1
-29.4
condition 2
-26.3
condition 3
-22.1
condition 4
0 ρ --- Fluid density,取 kg/m3
cost/yuan
Acid 1.1 —— —— 0 qv --- Flow Capacity,m3/h
cost/yuan
Energy 35.2 31.4 31.4 25.2
cost /yuan H --- Pumping head of the high pressure pump,m
Total 137.7 74.5 69.3 79.3
cost/yuan
ECH --- Cation bed capacity,mol
The operating condition 3 is the most economic
operation. Therefore, the best option for the plant is
b --- Consumption of reagent
controling the PH at 8.0 to get the 72% recovery rate, so that ε --- Consistency of HCL,%
the system could run in the most economic condition.
V. CONCLUSION REFERENCES
(1)The utmost recovery rate was made out through [1] Q. D. Qian, Water process engineering in power plant, BeiJing:
experiments, The results show that when the reverse osmosis China Electric Power Publisher, 1998.
system operates with PH value as 6.0, 7.0, 8.0, 9.0 four [2] J. Li, Z. Y. Xu, and H. Q. Yu, “Reverse osmosis treat the waste water
of the cooling wate,” China Water & Waste Water, vol. 28, pp. 74—
operating conditions separately, the limited recovery rate 77, August.
could be up to 78%, 75%, 72%, 50% separately. [3] F. Xu, J. S. Cao, and J. Cai, “Reverse osmosis treat and reuse the
(2)The desalination rate of various ions in water sample waste water of the cooling water,” China Water & Waste Water, vol.
is determined. When the PH<8.0, along with gradually 30, pp. 40—42, June. 2004.
increasing of the PH value, the desalination rate of various [4] M. Okazaki, “Water recycling using sequential membrane treatment
ions increase; When PH value stays between 8.0 to 9.0, in electronicsindustry,” Desalination, vol. 131, pp. 65—73, January
various ions get the highest desalination rates, among which 2004.
the lowest is K+, 96.8%, the highest is SO42-, 99.0%; When [5] J. Nieolaisen, “DeveloPments in membrane technology for water
the PH>9.0, various ions’ desalination rate decreases along treatment,”.Desalination. vol. 153, pp. 355—360, January 2002
with the PH value increases. [6] Z. Y. Dou, F. Zhang. P. Xu, Questions and answers about the
applications of reverse osmosis technology, BeiJing: Chemical
(3)When the feed water PH=6.0, recovery rate is 78%, Industry Press, 2004.
the desalination system is 94.7%, when the water PH=7.0, [7] Y. X. Feng, Reverse osmosis water treatment project, BeiJing: China
the recovery rate is 75%, the desalination system is 95.9%. Electric Power Publisher, 2005.
When the water PH=8.0, recovery rate is 72%, the [8] L. J. Guo, C. He, Pump and fan, BeiJing: China Electric Power
desalination rate is 96.7%, when the water PH=9.0, the Publisher, 2008.8
recovery rate is 50%, the desalination rate is 98.0%. [9] Y. C. Cui, Method and engineering application of desalination of
(4)The best option for the plant is controling the PH water, BeiJing: Chemical Industry Press, 2008.
value at 8.0 to get the 72% recovery rate, so that the system
could run in the most economic condition.