Professional Documents
Culture Documents
DPR - Preparation Data
DPR - Preparation Data
DATA
1. Location
2. Revenue Village
3. Taluk
4. District
5. VAO Statement
1. Registered Ayacut
2. Average Cultivation
3. Fasali details (5 Years)
4. Source of supply
a. Own Free catchment
b. Upper Tank
c. From Anicut across river
5. Surplus goes to
a. Lower Tank (or) River
6. Memoir of Tank
7. Village Map
8. F.M. Sketch of Tank
9. Ayacut Survey No
10. No.of Surplus arrangement details
11. No.of Sluice Details
12. Water spread area Survey Nos. in foreshore area.
6. G.I.Sheet
7. Walk through survey and Identify the existing conditions of Tank
1. Upper Tank
2. Lower Tank
3. Tank Bund
4. Surplus Arrangement
5. No.of Sluices
6. Water Spread area, Foreshore area, Ayacut area
7. Surplus course
8. Supply Channel
8. Total Length of bund from L.S 0m
9. L.S of weir and length of weir, existing condition of weir, Type of weir, apron
condition, surplus course condition
10. L.S of Sluices
Type of Sluice
Vent Size
Barrel Length
Existing Condition of Slucie
Preparation of Report for existing condition of tank and to discuss with Higher
officials
Proposals
1. Strengthening of tank bund and raising the Tank Bund for bund standards. Top width
3.00m, side slopes
Front 1 ½ : 1, Rear 2 : 1
4. Desilting of tank
DPR Preparation - Detailed Estimate Preparation
(Existing Top Bund level, Existing ground level, deep bed level, location of existing
structures)
Proposed for Renovation (or) Rehabilitation of Existing weir (or) Construction of weir
Hydrology
1. Free Catchment area
2. Intercepted catchment
3. Combined catchment area
4. Computation of max flood discharge
5. Fixation of F.T.L
M.W.L
T.B.L
6. Block levels @ weir site
From the surplus arrangement site block levels to Asses the average bed level
Hs Hs
Length of solid apron L1 = 4c x 4C
10 33
HS d Hs d
L = 10C 10C
10 75 33 75
Hs = Height of weir d = discharge in
d = Discharge in cuses/ ft.run cusesc/m.run
R= m
Adopt minimum 1.50m for scour depth for D/S cutoff wall
Creep length
Creep Length = CHS Hs = Height of weir - 1.20m
= 12 x 1.2 = 14.40m C = 12
Exist gradient
H = Height of weir
b = Width of impervious apron
d = Depth of D/S cutoff wall
ʎ = b/d
ʎ = 1 + √1 + ʎ 2
2
Reconstruction of Sluice
Contour Cumulative
Sl. Contour Area in Mean Capacity
intervals Capacity
No. Level in m. Sq.m. area M.Cum.
@m M.Cum.
53.000
1 - - - - -
(Sill level)
2 53.500 0.50
3 54.000 0.50
4 54.500 0.50
5 55.000 0.50
6 56.000 0.50
Contour Cumulative
Sl. Contour Area in Mean Capacity
intervals Capacity
No. Level in m. Sq.m. area M.Cum.
@m M.Cum.
7 56.500 0.50
= mm3
(-) Strenghthening of Tank Bund
Earth work quantity = (-) mm3
--------------------
Proposed desilting quantity = mm3
---------------------
DPR Estimate
1. Contents
2. Index Map
3. Report
4. General Abstract
5. Hydraulic Particulars Salient features
6. Strengthening of Tank Bund
7. Earthwork Calculation sheet
8. Detailed Estimate
9. Desilting Calculation sheet
10. Reconstruction of Weir D.E
11. Reconstruction of Sluice D.E
12. Lead
13. Data
14. E.W (Strengthening tank bund) Abstract
15. Desilting E.W Abstract
16. Reconstruction of weir Abstract
17. Reconstruction of Sluice Abstract
MAPS
1. Index Map
2. Catchment Area Map
3. Catchment Area Calculation Sheet
4. Reconstruction of Weir , Plan, Section
5. Reconstruction of Sluice, Plan, Section
6. L.S Plan (Tank Bund)
7. C.S Plan
8. Contour Level Map
9. Content Level Calculation Sheet
10. Ayacut Map
Report
Existing Conditions
Surplus Arrangement
Sluice
No.of Sluices
Location @ LS
Type of Sluice
Existing condition (Repair (or) Damaged Condition)
Sill level
Proposals
Tank Bund : Strengthening of tank bund Earth work Qty F.T.L + M.W.L+
T.B.L+ Top width 3.00m Side slopes front 1 ½ : 1 Rear 2 : 1
Sluice : Reconstruction of wing wall type sluice @ L.S m. Provision for U/S
leading channel with a length of m and D/S field channel for a length of
m are made in this estimate. Necessary provision for plug & plug rod has been
made in this estimate
Sill level :
Type of Sluice :
F.T.L :
M.W.L :
Vent Size : 0.15 x 0.15m
Plug hole size : 0.08mφ
Barrel length : m
Barrel size : 0.60x0.60m
Desilting of Tank : Necessary contour levels has been tank in water spread area of
tank. Per calculation necessary desilting Qty has been made in
this estimate
1. Name of Tank :
2. Village :
3. Taluk :
4. District :
5. Latitude, Longitude :
6. Free Catchment :
7. Intercepted Catchment :
8. Combined Catchment :
9. Max flood Discharge :
10. Capacity of F.T.L :
11. Registered Ayacut :
12. Water Spread Area :
13. F.T.L M.W.L TBL :
14. Tank Bund
Length of Bund : m
Top width : 3.00m
Side Slopes Front : 1½:1
Rear : 2 : 1
Length of Weir :
Type of weir :
Discharging capacity of weir :
Height of weir :
Head over crest :
Cutoff wall depth :
Length of solid apron :
16. Sluice
No.of Sluices :
Sluice at LS :
Type of Sluice : Wing wall Type
Sill level of Sluice : + m
Vent size : 0.15x 0.15m
Plug hole : 0.08m
Barrel length : 10m
Barrel size : 0.60m x 0.60m
Ayacut
Registered Ayacut : Acres
Average Cultivation : Acres
Gap : Acres
General Abstract
Provision
Total Rs.