Work Instruction No.

:
Asset Protection
Cathodic protection 6610

Approved by: Manager


Cathodic Protection Unit Inspection Pipeline Standards

1 PURPOSE and other debris, where required


report the condition of painted
The purpose of this work instruction is to
surfaces and signage.
describe the process verifying that Cathodic
Protection Units (CPU’s) are functioning • Inspect the condition of wire
correctly and are maintained in a safe working insulation, batteries, circuit breakers,
environment. All work shall comply with APT fuses and lightning arrestors. Carry-
O&MS Health, Safety and Environmental out any repairs where required.
Management Systems and meet the • Switch off the 240V AC supply then
requirements of all relevant statutory gas clean and check the physical
supply legislation. connections of components such as
rectifiers, transformers, AC and DC
2 REFERENCES cabling.
• Confirm the mode of operation -
9019 Cathodic Protection System constant current, constant voltage or
Maintenance and Testing Procedure potential control and record on the
Cathodic Protection Unit Inspection
3 GENERAL INFORMATION Test Report.
Minor inspections of CPU’s are usually • Perform any minor repairs. Report
conducted on a monthly basis to ensure the any major faults or damage for
functionality and integrity of all equipment follow-up maintenance.
associated with Cathodic Protection Unit. The • Test reports should be completed
frequency of minor inspections shall be no and forwarded to the Cathodic
greater than 2 monthly Protection Supervisor.
Major maintenance of CPU’s shall be carried
out on a 12 monthly basis. 4.2 Major Maintenance of CPU’s and
Ground Beds
4 PROCEDURE The items to be inspected during these
4.1 Minor Inspection of CPU’s maintenance routines are the Impressed
Current Cathodic Protection Unit, the anode
• Check that the unit is operating. ground bed and any power supply equipment.
• Check the voltage and current
outputs from the permanently Impressed Current Cathodic Protection
installed meters. Unit (CPU)
• Confirm that the direction of the The following items are to be covered:
current is flowing from the pipeline to
• Check the general condition of the
the ground bed.
CPU cabinet and mounting stand.
• Inspect the integrity of the anode bed Clean and touch up paintwork as
cabling and where possible measure required.
the potential of each anode in the
• With power to the unit isolated,
anode bed.
inspect the wiring for security and
• Make certain that the cabinet is deterioration.
secure, free from rust and hinges
• Inspect the cabinet for water ingress
and locks are functional.
and general cleanliness. Identify and
• Where required apply grease or rectify any water ingress.
lubricant to the cabinet door hinges
• Check all electrical components and
and locking mechanisms.
their mountings for security and
• Clean the cabinet and any ventilation deterioration.
screens of spider webs, bird nests
Issue 2 October 2007 Page1 of 2
Work Instruction No.:
Cathodic Protection Unit Inspection
6610

• Check vents and cooling fans if


fitted.
• Check panel doors and meters.
• Check the voltage and current
outputs using a multimeter and verify
the accuracy of the permanently
installed meters.
• Record the voltage and current
output.

Anode Ground Bed


The following items are to be covered:
• Check the integrity of cables looking
for any ground disturbance which
may have caused damage to the
cable’s or their connections.
• Check any new structures erected
near the ground bed to assess any
effect or damage to the ground bed.
• Conduct a loop resistance check to
determine if there has been any
increase in resistance. A significant
increase from “as commissioned”
readings would indicate a problem
with the ground bed or cable.
On completion of the inspections, complete
the relevant maintenance report sheet, noting
any items requiring further attention.

Issue 2 October 2007 Page 2 of 2