Professional Documents
Culture Documents
OceanStore v3 Storage System
OceanStore v3 Storage System
OceanStore v3 Storage System
System Product
Introduction
www.huawei.com
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 1
Contents
1. Product positioning
2. Hardware introduction
3. Software introduction
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 2
Product positioning
OceanStor V3 converged storage Centralized High-density Tiered Data disaster
storage virtualization storage recovery (DR)
systems
• Brand-new hardware architecture delivering
industry-leading performance and specifications:
The V3 converged storage systems employ 16 Gbit/s Fibre
Channel and 10 Gbit/s FCoE host ports and provide up to 40
GB/s system bandwidth, 4 TB cache capacity, and 8 PB storage
capacity.
• Convergence of SAN and NAS: SAN and NAS are
converged to provide elastic storage, simplify service
deployment, improve storage resource utilization, and reduce
total cost of ownership (TCO).
• Outstanding scalability and reliability: Up to eight
controllers and linear growth of performance and capacity are
supported. Loads are balanced among controllers that serve as
hot backup for each other, achieving higher reliability.
Online Resources are centrally stored, simplifying resource
deduplication management. Virtualization High
Up to eight and Wide channel Block-level specifications
controllers compression Latest 16 Gbit/s virtualization, Large capacity,
Higher storage Fibre Channel, heterogeneous high cache speed,
IP Scale-out and 12 Gbit/s SAS, virtualization, and and large number
load balancing resource and PCIe 3.0 computing of ports
utilization virtualization
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 3
Product positioning
Application
Type Model Feature Scenario
Unified storage Large-scale consolidation
High performance Layer 1 application
High-end storage Large capacity and virtualization
Functions first High-end 6800 V3
flexible scalability Mixed workloads
storage Maximum capacity Multiple application
Large optimization programs
enterprises High efficiency High-performance
Flash memory optimization application programs
Mid-range storage
Functions and Unified storage Enterprise application
Stable performance programs (Oracle
prices balanced 5800 V3 Large capacity and databases/emails/SAP)
Medium 5600 V3 flexible scalability Storage consolidation
enterprises
Mid-range
5500 V3 Maximum capacity Server virtualization
storage optimization Advanced storage tiering
5300 V3
Entry-level High efficiency Data protection
storage Flash memory optimization File sharing
Price first
Basic consolidation
Good performance and Microsoft application
Small 2600 V3 Programs
enterprises sufficient capacity
Entry-level 2200 V3 Entry-level server
Ease-of-use
storage Cost-effective virtualization
iSCSI SAN
Video surveillance
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 4
Contents
1. Product positioning
2. Hardware introduction
2.1 Hardware
3. Software introduction
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 5
Product form
OceanStor V3 converged storage systems adopt brand-new hardware
platform.
2200/2600/5300/5500 V3: disk and controller integration (2 U).
2200/2600 V3
5600/5800 V3
5300/5500 V3 S5500
T
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 6
Product features
High performance Robust reliability
PCIe 3.0 high-speed bus and SAS 3.0 Full redundancy design
high-speed I/O channel Built-in BBUs+data coffer
Various data protection technologies
Flexible scalability
Hot-swappable I/O interface modules Energy saving
Support for 4 interface modules and 2 Intelligent CPU frequency control
onboard interface modules (2 U)
Delicate fan speed control
Support for 16 interface modules (3 U)
Support for 24 interface modules (6 U)
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 7
OceanStor 2200 V3 Controller
Enclosure
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 8
OceanStor 2600 V3 Controller
Enclosure
AC, -48 V DC, or Each controller provides only on the front end
two SAS expansion Port type: 8 Gbit/s Fibre Channel (4 x
240 V high-voltage
DC ports. 8 Gbit/s Fibre Channel or 8 x 8 Gbit/s
Onboard port Fibre Channel), GE, 10GE electrical
Four GE ports on each
port, SmartIO card (16 Gbit/s Fibre
OceanStor 2600 V3 controller Channel, 8 Gbit/s Fibre Channel, 10
Gbit/s FCoE (VN2VF), and 10 Gbit/s
ETH (optical port)
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 9
5300/5500 V3 controller enclosure (25
disk slots)
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 10
5300/5500 V3 controller enclosure (12
disk slots)
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 11
5300/5500 V3 rear panel
Serial port
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 12
5600/5800 V3 controller enclosure
BBU module
5600 V3: 1+1 redundancy
(remaining two slots
inserted by filler BBU
modules); 5800 V3: 2+1
redundancy (remaining one
slot inserted by a filler BBU
module)
DC/AC power failure
protection
Controller module
Support for dual controllers
and four controllers
Mainstream server platform
Management module
Power module Interface module
1+1 redundancy
16 interface module slots
1+1 redundancy
A maximum of 1250 disks Hot-swappable
Up to 94% power
Hot-swappable Support for multi-controller
conversion efficiency Rich port types: 16 Gbit/s Fibre Channel,
Scale-out interconnection
240 V high-voltage DC 12 Gbit/s SAS, GE, 10GE TOE, 10GE
with a heartbeat
FCoE, and 8 Gbit/s Fibre Channel
mechanism
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 13
5600/5800 V3 ports
1 23 4 5 6
9 8 7
9 GE port
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 14
6800 V3 controller enclosure (1)
BBU module
3+1 redundancy
protection
Controller module
Support for dual controllers and four
controllers
Mainstream server platform
Automatic frequency control and energy
saving
Fan module (integrated into a controller
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 15
6800 V3 controller enclosure (2)
Management module
1+1 redundancy
Hot-swappable
controller Scale-out
interconnection with a
heartbeat mechanism
Interface module
Dual controllers: 12 interface module
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 16
6800 V3 ports
1
2
3
4
5
6
9 8 7
Managemen
USB port Management Management
1 2 t network 3 4
(reserved) network port 1 network port 2
port 0
Maintenanc
8 Gbit/s Fibre
5 e network 6 Serial port 7 12 Gbit/s mini SAS HD 8 9 GE port
Channel port
port
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 17
2 U 2.5-inch disk enclosure
2.5-inch disk unit
No disk connector
Expansion module
Dual expansion
modules
12 Gbit/s SAS
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 18
4 U 3.5-inch disk enclosure
3.5-inch disk unit
No disk connector
NL-SAS disks
Expansion module
Dual expansion
modules
12 Gbit/s SAS uplink
and downlink
Fan module
2 fan modules (2 fan
modules and 2 power
modules compose a heat
dissipation module.)
5+1 redundant fan
modules in a disk
enclosure
High-speed fans
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 20
4 U 3.5-inch high-density disk
enclosure (2)
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 21
4 U 3.5-inch high-density disk
enclosure (3)
Disk enclosure cover
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 22
IP Scale-out (2 U)
The smart I/O interface
module is required by Scale-
out and must be inserted into
slot 1.
A1
2600 V3 B1
5300/5500 V3
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 23
IP Scale-out (2 U, 4-controller direct-
connection network)
2600 V3
5300/5500 V3
Customer management
network Data switched
network
2600 V3
5300/5500 V3
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 24
IP Scale-out (2 U, 4-controller switch-
connection network)
Data switched
network
10GE switch: 10GE switch:
HUAWEI HUAWEI
CE6850 CE6850
2600 V3 2600 V3
5300/5500 V3 5300/5500 V3
Customer
management The switch-connection
The direct-connection network
network network supports a
cannot be switched to the
maximum of eight
switch-connection network.
controllers.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 25
IP Scale-out (3 U)
The smart I/O interface
module is required by
Scale-out and must be
Back-end port Front-end service Scale-out port inserted into slot 3.
port
A3 B3
5600/5800 V3
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 26
IP Scale-out (3 U, 4-controller direct-
connection network)
5600/5800 V3
Customer
management
network
5600/5800 V3
The direct-
connection
network
supports a
maximum of
four
controllers.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 27
IP Scale-out (3 U, 8-controller switch-
connection network)
5600/5800 V3
10GE switch:
HUAWEI
CE6850
Customer
management Data switched
network network
10GE switch:
HUAWEI CE6850
The switch-
connection The direct-connection
network network cannot be
supports a switched to the switch-
maximum of connection network.
eight
controllers.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 28
IP Scale-out (6 U)
Back-end port Front-end service port
6800
V3
6900
V3
A3 B3
The smart I/O interface
module is required by
Scale-out slots (fixed) Scale-out and must be
inserted into slot 3.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 29
IP Scale-out (6 U, 8-controller switch-
connection network)
6800
V3
10GE switch:
6900 HUAWEI
V3 CE6850
6 U controller
The switch- enclosures do
connection not support the
network supports direct-
a maximum of connection
6800
eight controllers. network.
V3
6900
V3
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 30
Contents
1. Product positioning
2. Hardware introduction
2.1 Hardware
3. Software introduction
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 31
Smart I/O interface module
3
3 Port indicator (Link/Active/Mode indicator)
5
4 Module handle
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 32
Onboard Smart I/O interface module
1 3
2 4
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 33
8 Gbit/s Fibre Channel high-density
interface module (1)
The interface module provides two 4 x 8 Gbit/s Fibre
Channel physical ports. The two ports are converted into
eight 8 Gbit/s Fibre Channel optical ports using dedicated
1 4 optical cables (no optical module connected to the eight
ports). The eight ports are used as service ports to connect
application servers to storage systems and used to receive
data exchange commands from application servers.
The interface module contains two 4 x 10 Gbit/s QSFP+
2
optical modules.
The interface module is equipped with 15 m four-in-one
dedicated optical cables.
3
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 34
8 Gbit/s Fibre Channel high-density
interface module (2)
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 35
10 Gbit/s ETH electrical interface
module
5 Module handle
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 36
56 Gbit/s IB interface module
3 5 Module handle/Silkscreen
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 37
Deduplication and compression
acceleration interface module (ACC)
3
1
1 Power indicator/Hot Swap button
3 Module handle/Silkscreen
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 38
Contents
1. Product positioning
2. Hardware introduction
3. Software introduction
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 39
OceanStor V3 Software Feature
Usage Scenario
Single-Node 2200 V3 Dual-Node 2200 V3 2600 V3/Mid-Range V3
Mid-range V3 produces include 5300 V3, 5500 V3, 5600 V3,5800 V3,6800 V3.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 40
Software architecture
Traditional storage systems OceanStor V3 converged storage systems
NAS
SAN NAS or
SAN NAS+SAN
Two storage systems are required to Block- and file-level data storage is unified,
provide requiring no additional file engines, reducing
SAN and NAS services. purchasing costs by 15% and decreasing
power consumption.
The efficiency of databases and file
Underlying storage resource pools provide
sharing services cannot be maximized.
SAN and NAS, ensuring that database and
file sharing services are equally efficient.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 41
Integrated and unified storage
architecture
OceanStor OS SAN and NAS parallel architecture
Parallel: NAS and SAN
NAS SAN software protocol stacks are
File service Block service parallel. File systems adopt
(CIFS/NFS) (FC/iSCSI) ROW, and thin LUNs and
thick LUNs adopt COW,
File Semantics LUN Semantics
adapting to different
System application scenarios.
Cache
control
Object Volume
Converged: NAS and SAN
are converged on the
resource allocation and
Storage pool
management planes, disk
blocks are allocated based
on the RAD 2.0 architecture,
and cache resources are
shared, improving resource
utilization.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 42
Software deployment
Multipathing Host application integration software
Failover and failback Disk Guard and Host agent
Management software
NAS protocol SAN protocol GUI/CLI/SNMP
NFS/CIFS FC /iSCSI/SCSI OMM
Alarms, logs, and performance statistics
Replication
Snapshot, clone, HyperMirror, LUN copy, and Device
remote replication Public System
managemen
mechanism control
Initialization tPower
Object management Volume management QoS
Configuration BBU
Object Volume Cache change
Transactions
System Fan
Storage pool anomaly
RAID2.0, storage resource management, Temperature
System resources
and dynamic storage tiering Controller
Unified thread enclosure
Logical disk Disk
Memory management
Internal disk and heterogeneous LUNs enclosure
Link channel
Port
Device drive and OS
FC/SAS/iSCSI drive Kernel, BSP, BIOS, and PCIe BMC and SES
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 43
Software architecture (1)
Protocol layer (NAS and SAN protocols)
Implements NAS and SAN interface protocol processing.
Replication layer
Implements value-added functions for LUNs and file systems, for example, remote
replication, clone, and HyperMirror.
Space management layer
Allocates and manages underlying space of LUNs and file systems.
Implements the COW and ROW space allocation mechanism.
Storage pool
Divides space provided by physical disks into fine-grained blocks to distribute services
to all disks, bringing disk performance into full play.
Improves the speed of reconstructing bad disks.
Implements tiered storage.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 44
Software architecture (2)
Management software (GUI/CLI/SNMP)
Supports storage device management on GUI and CLI.
OMM
Collects statistics about and dump storage alarms, logs, and performance data.
System control
Manages storage clusters.
Initializes and powers off storage systems and troubleshoots faults on the control plane.
Device management
Monitors and manages storage hardware such as fans, power modules, controller
enclosures, and expansion enclosures.
Device drive/OS
Provides a basic OS operating environment and hardware drive.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 45
Block virtualization (1)
LUN
LUN
Extent Extent Extent Extent Extent Extent Extent Extent Extent
Exten Exten Exten Exten CKG Exten Exten Exten Exten CKG
t t t t t t t t
CK CK CK CK CK CK CK CK
CKG CKG
CK CK CK CK CK CK CK CK CK CK CK CK
Disk
Disk Domain
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 46
Block virtualization (2)
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 47
SmartTier
Initial distribution of LUN
data in a storage system After data relocation
pool
High
performance
tier
Performance
tier
Capacity
tier
LUN
Warm Cold
Hot data data data
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 48
SmartQoS
Front-end resources (IOPS/bandwidth)Running period
0:00–8:00
IOPS < 200
OLTP services
Archiving and
Ensuring sufficient backup services Bandwidth < 30 MB/s User B (silver)
resources
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 49
SmartThin
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 50
SmartPartition
Host
concurrency
Cache
Disk access
concurrency
Service N
Service 1
Service 2
Service 3
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 51
SmartVirtualization
SmartVirtualization takes over
heterogeneous LUNs without implementing
RAID 2.0+ block virtualization.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 52
SmartMigration
Application scenarios
Benefits
storage systems.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 53
SmartMulti-Tenant
Tenant Tenant Tenant
administrator 1 administrator 2 administrator 3
Storage administrator
Performance monitoring: Tenants can view performance data, such as read and write bandwidths, of
disks.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 54
Data Reduction
Data Reduction
This feature can be used to reduce the storage space that is occupied by data. It is only applicable to thin LUNs.
The data that is newly written into storage arrays is detected to ensure that all-zero data does not occupy
storage space.
Two data reduction methods:
When all-zero data is written into a storage device, the storage device does not allocate storage space to
the data.
When all-zero data is written into a storage device, the storage space that has been allocated is
reclaimed.
Data Reduction can be enabled only when thick LUNs are converted into thin LUNs.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 55
HyperMirror (1)
From external
storage arrays
Host
MirrorLun From local pools
Huawei storage array
MirrorCopy MirrorCopy
LUN
Heterogeneous storage
Scenario 1 Mirroring of a single heterogeneous storage
array
array (improving reliability).
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 56
HyperMirror (2)
From external
Host storage arrays
MirrorLun
LUN LUN
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 57
HyperMirror (3)
Within one engine
Host
MirrorLun
MirrorCopy MirrorCopy
Scenario 3 HyperMirror within storage arrays (Single LUN failure is eliminated and LUNs are in
different disk domains).
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 58
3DC
Production Intra-city Productio Intra-city
center DR center n center DR center
Synchronous/ Synchronou
Asynchronous s/Asynchron
ous
Production DR Production DR array
array array WA array
Remote Remote DR
DR center NAsynchronous center
WA
Asynchronous
N
Synchronous and
asynchronous Synchronous and
DR asynchronous (one- DR array
(multi-hop)
array to-many)
Intra-city DR
Production
center
center Synchronous
/Asynchrono
us
Producti DR array
on array WA
Remote
WA DR center NAsynchronous
AsynchronousN
(full copy)
Star DR array
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 59
SmartCache
SSD SSD
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 60
File system (1)
Fixed-length blocks with
adjustable sizes: 4 KB, 16 Root
KB, 32 KB, or 64 KB
(default size) Indirect block B+ Tree
Indirect block
D node
Object set: file
system & snap
B+ Tree
D node
Object: file &
directory
B+ Tree
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 61
File system (2)
4 KB
3. Data blocks
D node bp larger than 2 MB
use B+ tree
storage.
4 KB
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 62
File system (3)
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 63
CIFS/SMB
In 1996, Microsoft renamed SMB as Common Internet File System
(CIFS) and developed many new functions.
CIFS is a general term for Server Message Block (SMB). SMB includes
SMB 1.0, SMB 2.0, and SMB 3.0.
CIFS client
CIFS server
Network
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 64
NFS
Enterprise office NFS application network
IP IP
Linux
IP IP
NAS server
LAN
NFSv3/NFSv4
LDAP/NIS server Two types of networks are available for the NAS and
NFS sharing services:
1. Non-domain environment.
2. LDAP/NIS domain environment.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 65
NDMP
NDMP scope
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 66
FTP/HTTP
Used to transfer files between remote servers and local hosts, File Transfer Protocol (FTP) is
a common protocol for file transfer over IP networks.
TCP port 20 is used to transfer data and TCP port 21 is used to transfer control messages.
Basic FTP operations are described in RFC959.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 67
SmartQuota
SmartQuota is a resource (capacity) control
technology and is used to manage directory
quotas, including quotas related to capacities
and number of files.
SmartQuota checks whether the consumed
capacity and the number of involved files of
each I/O request exceed the preset quota.
Therefore, SmartQuota decreases system
performance.
If the hard quota is exceeded, the I/O request is
rejected and a message is sent to users
indicating that the space is insufficient.
If the hard quota check passes, the I/O request
is processed.
If the soft quota is exceeded, an alarm is
reported.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 68
SmartLock (File system WORM)
Write once read many (WORM) is a write once technology that allows a file to enter the
protection state after data is written into it.
A file in the protection state can be read but cannot be deleted, modified, or renamed.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 69
SmartDedupe
Mapping
Sharing
ROW LUN
Host1
Host0
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 70
SmartCompression
1. Fixed-length data 3. Deduplicated data
blocks are created. The 2. Data blocks are blocks are
size of each data block deduplicated. compressed and
is the same as that of a stored.
file system (FS) block.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 71
LUN deduplication and compression
NAS SAN
System
Cache
control
Object Volume
ROW COW
Storage pool
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 72
HyperSnap (File system snapshot)
File system Snap (T1)
Generating a
file1 file2 snapshot file1 file2
file3 file3
file3 file4
time file3
Main operations include:
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 73
HyperReplication
V3 converged storage systems support synchronous and asynchronous
remote replication between LUNs and file systems.
NFS/CIF NFS/CIF
S S
File File
System FC/ iSCSI System
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 74
Summary
Product positioning
Hardware introduction
Software introduction
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 75
Exercises
1. (True or false) V3 converged storage systems inherit the hardware platform of T series.
2. (Multiple-answer question) Which of the following functions are provided by the software
platform of V3 converged storage systems?
SmartPartition
SmartTier
SmartQoS
SmartThin
SmartMotion
3. (Multiple-answer question) Which of the following are the advantages of the block virtualization
architecture?
Faster reconstruction
Improved disk reliability
Easy tiered storage
Cool name
4. (Multiple-answer question) Which of the following statements are true about SmartTier?
A. SmartTier improves the performance of storage systems.
B. Data relocation implemented by SmartTier deteriorates system performance.
C. SmartTier cannot be used with the SmartThin simultaneously.
SmartTier can be enabled only when a storage pool contains disks of different storage levels.
5. (Single-answer question) Which of the following statements is true about SmartQoS?
A. SmartQoS ensures the performance of mission-critical applications.
B. SmartQoS provides the priority function only.
Copyright © 2016 Huawei Technologies Co., Ltd. All rights reserved. Page 76
Thank you
www.huawei.com