RIOSEIS GX TM

Gelatinous seismic explosive (plastic shell)

TECHNICAL DATA SHEET DESCRIPTION

RIOSEIS GX is part of the newest generation of gelatinous sodium


nitrate explosives and is produced by MAXAM .

RIOSEIS GX is cap sensitive but nevertheless safe to handle.


Basically it consists of sodium nitrate, mixtures of nitroglycol and
nitroglycerine, nitrocellulose and other additives.

RIOSEIS GX doesn´t contain any nitro aromatic bonds like DNT or


TNT, which have been classified by the EU commission as
carcinogenic substances by now and therefore meets the current
requirements.

RIOSEIS GX is characterized by its high frequency energy impulse,


is easy to assemble and, through its so texture under low
temperature, is easily punchable.

Because of its high density it is easily sinking in water and mud.


RIOSEIS GX stands out through its excellent water resistance

APPLICATIONS

RIOSEIS GX stands out due to its very high efficiency and its user
friendly handling in particular and therefore is predestined for use
as a Seismic explosive where strong and sharp detonating impulses
are presupposed.

RIOSEIS SEISMIC EXPLOSIVE

1. Shell design channel for proper legwire placement and initiation. USE REGULATIONS

2. Plastic interlocking shell design for easy and firm assembly. RIOSEIS GX is deliverable as of a cartridge diameter of 25 mm. The
explosive isn‘t allowed for underground use. The initiation must be
made by a detonator with a secondary charge of 0,6 g PETN (No. 8
strength blasting cap) or a detonator with comparable initiation
ADVANTAGES power. The maximum permi ed hydrostatic pressure is 40 bars. The
application temperature for RIOSEIS GX is from -40 °C up to +60 °C.

Safe, reliable and user friendly. USE RECOMMENDATIONS


Designed to work under any environment. RIOSEIS GX is suitable for many application areas of the seismic
Variable size to suit application. blasting technology due to its very high energy density, its relatively
high density as well as the high water resistance.
High detonation pressure output.

Water resistant.

Performs consistently regardless of hydrostatic pressure.

maxam.net TDS RIOSEIS GX PLASTIC SHELL ENG 190916


RIOSEIS GX TM

Technical Data

Paste Density Gas Specific Pressure Heat Oxygen


V.O.D
(g/cm3) Volume Energy of explosion of explosion balance

1,65 523 I/kg 588 kJ/kg 15,1 GPa 4.186 kJ/kg + 0,1% 6.300 m/s(*)

(*) in 2 inches measured within blasthole.

Rigid Plastic Shell

Cartridges Units per Case Boxes

Weight D L D L Net Gross Cart/Box


Case Dimensions (mm)
kg mm mm inch inch kg kg ud

1/4 32 215 1 1/4 8 1/2 25,0 27,0 99 370 x 260 x 215


1/2 50 190 2 7 1/2 20,0 22,0 40 410 x 255 x 205
1 50 370 2 14 1/2 20,0 22,0 20 370 x 260 x 215
2 1/4 21 1/2 24,0 26,0 12 550 x 230 x 175
2 57 550

Transport Classification Standard Packaging

Class 1.1D
Contact your local MAXAM
representative for further information
UN Number 0081 and for obtaining a TDS in the local language.

SAFETY WARNING
Read the Instructions Safety Sheet and the Material Safety Data Sheet provided carefully before using RIOSEIS GX. RIOSEIS GX must not be used in
flammable environments such as methane or coal dust. MAXAM strongly recommends not to use RIOSEIS GX products with detonators and/or initiation
systems supplied by other manufacturers in the same blast and declines all liability in these cases.
RIOSEIS GH must be stored at moderate temperatures in a dry and well ventilated place.

DISCLAIMER AND LIMITATION OF LIABILITY


The information contained herein (the “Information”) is not exhaustive and subject to periodical review. The data contained herein may vary on account of the
particular operating and maintenance conditions and of external factors, such as humidity, temperature, or pressure. Maxam Europe, S.A. and/or its affiliates
(“MAXAM”) do not warrant or make any representation regarding the accuracy or completeness of the Information. MAXAM further reserves the right, in its
sole discretion and without prior wri en notice, to modify the products described herein (the “Products”) and/or their specifications.
The use of the Products is an intrinsically dangerous activity and must, consequently, be restricted to qualified and trained users in possession of any
necessary permits and licenses, and comply at all times with appropriate safety and risk prevention measures and with the applicable law. The use, storage, or
otherwise handling, of the Products may be subject to local regulations and restrictions, which must be examined and observed by the user.
This document and any accompanying information (the “Documentation”) is not intended to constitute, and shall not be construed as, an offer or contractual
commitment on MAXAM’s side. MAXAM expressly disclaims any liability towards third parties with regard to the Documentation. For further information
about the Products, please contact your distributor or sales representative directly.

Distributor

maxam.net TDS RIOSEIS GX PLASTIC SHELL ENG 190916

You might also like