Attachment - 8

DATA SHEET FOR PRESSURE SAFETY VALVE


Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet No.
Code

DATA SHEET FOR PRESSURE SAFETY VALVE OIL-100-EK-I-DS-0808 A0 Sht.No:02 of 07

TABLE OF CONTENTS

Description Sheet Number

1. Cover Sheet 01 of 07
2. Index Sheet 02 of 07
3. Revision Sheet 03 of 07
4. Notes Sheet 04 of 07
5. DS-1 05 of 07
6. DS-2 06 of 07
7. DS-3 07 of 07
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES
(GGS) AT EAST KHAGORIJAN Rev
Datasheet No.
Code

DATA SHEET FOR PRESSURE SAFETY VALVE OIL-100-EK-I-DS-0808 A0 Sht.No: 03 of 07

REVISION List

Tenability for
Rev Rev Disc. Reasons Impact on MTO
extra Claim

A0 Issued for Review

HOLD List
Revision Index
CREATION OF SURFACE PRODUCTION
FACILITIES (GGS) AT EAST KHAGORIJAN Rev
Datasheet No.
Code

DATA SHEET FOR PRESSURE SAFETY VALVE OIL-100-EK-I-DS-0808 A0 04 of 07

Notes:
1. Documentation required :- Calibration Certificate,Material Certificates to 3.1 as per EN10204,Pressure test procedure/ Report

, NDT procedure / Report, Operating & Maintenance Instructions & Spare Parts List, Hydro Test, Pop test report & Installation

dimension Drawings.

2. All Instruments to be supplied with SS316 name plate with tag no. permanently inscribed. Tags shall be permanently

secured.

3. Nozzle, Seat and Disc for the above tags shall be forged.

4. All stud bolt and nut material shall be ASTM A193 Gr. B7M & Heavy hex nuts shall be ASTM A194 Gr. 2HM.

5. Painting shall be as per Protective Coating specification for Onshore Structures and Facilities.

6. All castings and welding shall be 100% radio graphed.

7. Carbon steel springs with Nickel plating shall be used for temperature services lower than 250 Deg C.

Tungsten alloy springs shall be used for temperatures greater than 250 Deg.C.

8. All relief valves of size 1" and above shall be full nozzle full lift type. Relief valves with size less than 1" shall be modified

nozzle type.

9. The pressure relief valve shall meet the requirements of API recommended practice RP 526 ‚Flanged Steel Safety Relief

Valves and RP 521‚ Pressure Relieving and Anti Pressurizing system and shall be of direct acting angle pattern,

full nozzle entry and high capacity type.


TITLE ITEM/TAG No. DATA SHEET No.
PRESSURE SAFETY VALVE REFER BELOW OIL-100-EK-I-DS-0808
PROJECT DESCRIPTION PROJECT No. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 07 A0
MPC CONTRACTOR PURCHASE ORDER No. REQUISITION NO. SPECIFICATION No.
TBA - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED / TEC LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT DOCUMENT No.
-
ORIGINATOR ORIG. DATE
IMR 19-Sep-18
2 3
UNITS:- Pressure psig kg/cm g kPag barg Flow : Gas MMscfd MMSCMD Sm /hr kg/hr
O O
Temp C F Liquid: m3/hr kg/hr USgpm BLPD
1 TAG No. 20-PSV-1380A 20-PSV-1380B 41-PSV-3728A 41-PSV-3728B
Hot Oil Return to Hot Oil Hot Oil Return to Hot Oil Return Drum Hot oil to Hot Oil Drain Drum Hot oil to Hot Oil Drain Drum
2 SERVICE
Return Drum Bypass (EK-MBD-3320) (EK-MBD-3320) Bypass
3 VESSEL No. - - - -
GENERAL

4 LINE No. 2"-HM-41-3753-BC01 2"-HM-41-3753A-BC01 2"-HM-41-3734-BC01-1N 2"-HM-41-3734A-BC01-1N

5 P &ID NUMBER 17039-EK-P-DW-0202-13 17039-EK-P-DW-0202-13 17039-EK-P-DW-0203-10 17039-EK-P-DW-0203-10

6 FULL NOZZLE/SEMI-NOZZLE FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT

7 SAFETY / RELIEF / SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF

8 CONV., BELLOWS, PILOT OP. CONVENTIONAL CONVENTIONAL CONVENTIONAL CONVENTIONAL

9 BONNET TYPE CLOSED BONNET CLOSED BONNET CLOSED BONNET CLOSED BONNET
CONNECTION

10 SIZE INLET OUTLET 1" 2" 1" 2" 1" 2" 1" 2"

11 FL. RATING INLET OUTLET 300# 300# 300# 300# 300# 300# 300# 300#

12 FL. FACE INLET OUTLET RF RF RF RF RF RF RF RF

13 BODY CS, ASTM A105 CS, ASTM A105 CS, ASTM A105 CS, ASTM A105

14 BONNET CARBON STEEL CARBON STEEL CARBON STEEL CARBON STEEL

15 NOZZLE, SEAT and DISC SS 316 SS 316 SS 316 SS 316


MATERIAL

16 RESILIENT SEAT SEAL SS 316 SS 316 SS 316 SS 316

17 GUIDE AND RINGS SS 316 SS 316 SS 316 SS 316

18 SPRING CS with Nickle Plate CS with Nickle Plate CS with Nickle Plate CS with Nickle Plate

19 BELLOWS N/A N/A N/A N/A

20 CAP: SCREWED or BOLTED SCREWED SCREWED SCREWED SCREWED

21 LEVER: OPEN or PACKED N/A N/A N/A N/A


OPTIONS

22 TEST GAG REQUIRED REQUIRED REQUIRED REQUIRED

23 CODE API RP 520 API RP 520 API RP 520 API RP 520

24 BASIS THERMAL EXPANSION THERMAL EXPANSION THERMAL EXPANSION THERMAL EXPANSION

25 VESSEL SIZE DIA X T/T TBA TBA TBA TBA

26 FLUID STATE HOT OIL LIQUID HOT OIL LIQUID HOT OIL LIQUID HOT OIL LIQUID

27 REQUIRED CAPACITY (VAPOUR/LIQUID)

28 OPERATING S.G MOL. WEIGHT


29 OPER. PRESS SET PRESS ATM 12 ATM 12 5.5 12 5.5 12

30 OPER. TEMP REL. TEMP 27-50 27-50 200 200


31 CONSTANT
32 BACK PRESSURE VARIABLE
33 TOTAL
FLUID DATA

34 % ALLOWABLE OVER PRESSURE


35 OVER PRESSURE FACTOR
36 COMPRESSIBILITY FACTOR
37 LATENT HEAT OF VAPORIZATION (KJ/Kg)
38 RATIO OF SPECIFIC HEATS Cp / Cv
39 OPERATING VISCOSITY cP
40 VAPOUR GAS MASS FRACTION
41 BAROMETRIC PRESSURE
42 ENVIRONMENTAL FACTOR
43 VESSEL / WETTED
44 RATED CAPACITY
2
45 CALCULATED AREA inch * * * *

46 SELECTED AREA inch2 * * * *

47 ORIFICE DESIGNATION * * * *

48 MANUFACTURER * * * *

49 MODEL No. * * * *

50 NOTES:- * BY VENDOR

51 REFER NOTES SHEET


52
53
54
55
56
57
58
59
TITLE ITEM/TAG No. DATA SHEET No.
PRESSURE SAFETY VALVE REFER BELOW OIL-100-EK-I-DS-0808
PROJECT DESCRIPTION PROJECT No. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 06 OF 07 A0
MPC CONTRACTOR PURCHASE ORDER No. REQUISITION NO. SPECIFICATION No.
TBA - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED / TEC LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT DOCUMENT No.
-
ORIGINATOR ORIG. DATE
IMR 19-Sep-18
2 3
UNITS:- Pressure psig kg/cm g kPag barg Flow : Gas MMscfd MMSCMD Sm /hr kg/hr
O O
Temp C F Liquid: m3/hr kg/hr USgpm BLPD
1 TAG No. 41-PSV-3729A 41-PSV-3729B 41-PSV-0121A 41-PSV-0121B
Hot Oil to Hot Oil Drain Hot oil return to Hot Oil Drain Drum Hot oil return to Hot Oil Drain Drum
2 SERVICE Hot Oil to Hot Oil Drain Drum Bypass
Drum (EK-MBD-3320) (EK-MBD-3320) Bypass
3 VESSEL No. - - - -
GENERAL

4 LINE No. 2"-HM-41-3737-BC01-1N 2"-HM-41-3737A-BC01-1N 2"-HM-41-3671-BC01-1N 2"-HM-41-3671A-BC01-1N

5 P &ID NUMBER 17039-EK-P-DW-0203-11 17039-EK-P-DW-0203-11 17039-EK-P-DW-0203-14 17039-EK-P-DW-0203-14

6 FULL NOZZLE/SEMI-NOZZLE FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT

7 SAFETY / RELIEF / SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF

8 CONV., BELLOWS, PILOT OP. CONVENTIONAL CONVENTIONAL CONVENTIONAL CONVENTIONAL

9 BONNET TYPE CLOSED BONNET CLOSED BONNET CLOSED BONNET CLOSED BONNET
CONNECTION

10 SIZE INLET OUTLET 1" 2" 1" 2" 1" 2" 1" 2"

11 FL. RATING INLET OUTLET 300# 300# 300# 300# 300# 300# 300# 300#

12 FL. FACE INLET OUTLET RF RF RF RF RF RF RF RF

13 BODY CS, ASTM A105 CS, ASTM A105 CS, ASTM A105 CS, ASTM A105

14 BONNET CARBON STEEL CARBON STEEL CARBON STEEL CARBON STEEL

15 NOZZLE, SEAT and DISC SS 316 SS 316 SS 316 SS 316


MATERIAL

16 RESILIENT SEAT SEAL SS 316 SS 316 SS 316 SS 316

17 GUIDE AND RINGS SS 316 SS 316 SS 316 SS 316

18 SPRING CS with Nickle Plate CS with Nickle Plate CS with Nickle Plate CS with Nickle Plate

19 BELLOWS N/A N/A N/A N/A

20 CAP: SCREWED or BOLTED SCREWED SCREWED SCREWED SCREWED

21 LEVER: OPEN or PACKED N/A N/A N/A N/A


OPTIONS

22 TEST GAG REQUIRED REQUIRED REQUIRED REQUIRED

23 CODE API RP 520 API RP 520 API RP 520 API RP 520

24 BASIS THERMAL EXPANSION THERMAL EXPANSION THERMAL EXPANSION THERMAL EXPANSION

25 VESSEL SIZE DIA X T/T TBA TBA TBA TBA

26 FLUID STATE HOT OIL LIQUID HOT OIL LIQUID HOT OIL LIQUID HOT OIL LIQUID

27 REQUIRED CAPACITY (VAPOUR/LIQUID)

28 OPERATING S.G MOL. WEIGHT


29 OPER. PRESS SET PRESS 5.5 12 5.5 12 5.5 12 5.5 12

30 OPER. TEMP REL. TEMP 200 200 200 200


31 CONSTANT
32 BACK PRESSURE VARIABLE
33 TOTAL
FLUID DATA

34 % ALLOWABLE OVER PRESSURE


35 OVER PRESSURE FACTOR
36 COMPRESSIBILITY FACTOR
37 LATENT HEAT OF VAPORIZATION (KJ/Kg)
38 RATIO OF SPECIFIC HEATS Cp / Cv
39 OPERATING VISCOSITY cP
40 VAPOUR GAS MASS FRACTION
41 BAROMETRIC PRESSURE
42 ENVIRONMENTAL FACTOR
43 VESSEL / WETTED
44 RATED CAPACITY
2
45 CALCULATED AREA inch * * * *

46 SELECTED AREA inch2 * * * *

47 ORIFICE DESIGNATION * * * *

48 MANUFACTURER * * * *

49 MODEL No. * * * *

50 NOTES:- * BY VENDOR

51 REFER NOTES SHEET


52
53
54
55
56
57
58
59
TITLE ITEM/TAG No. DATA SHEET No.
PRESSURE SAFETY VALVE REFER BELOW OIL-100-EK-I-DS-0808
PROJECT DESCRIPTION PROJECT No. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 07 OF 07 A0
MPC CONTRACTOR PURCHASE ORDER No. REQUISITION NO. SPECIFICATION No.
TBA - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED / TEC LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT DOCUMENT No.
-
ORIGINATOR ORIG. DATE
IMR 19-Sep-18
2 3
UNITS:- Pressure psig kg/cm g kPag barg Flow : Gas MMscfd MMSCMD Sm /hr kg/hr
O O
Temp C F Liquid: m3/hr kg/hr USgpm BLPD
1 TAG No. 41-PSV-6624A 41-PSV-6624B
Hot oil retrun to Hot Oil Hot oil retrun to Hot Oil Drain Tank
2 SERVICE
Drain Tank ByPass
3 VESSEL No. - -
GENERAL

4 LINE No. 2"-HM-41-6637-BC01-1N 2"-HM-41-6856-BC01-1N

5 P &ID NUMBER 17039-EK-P-DW-0206-04 17039-EK-P-DW-0206-04

6 FULL NOZZLE/SEMI-NOZZLE FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT

7 SAFETY / RELIEF / SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF

8 CONV., BELLOWS, PILOT OP. CONVENTIONAL CONVENTIONAL

9 BONNET TYPE CLOSED BONNET CLOSED BONNET


CONNECTION

10 SIZE INLET OUTLET 1" 2" 1" 2"

11 FL. RATING INLET OUTLET 300# 300# 300# 300#

12 FL. FACE INLET OUTLET RF RF RF RF

13 BODY CS, ASTM A105 CS, ASTM A105

14 BONNET CARBON STEEL CARBON STEEL

15 NOZZLE, SEAT and DISC SS 316 SS 316


MATERIAL

16 RESILIENT SEAT SEAL SS 316 SS 316

17 GUIDE AND RINGS SS 316 SS 316

18 SPRING CS with Nickle Plate CS with Nickle Plate

19 BELLOWS N/A N/A

20 CAP: SCREWED or BOLTED SCREWED SCREWED

21 LEVER: OPEN or PACKED N/A N/A


OPTIONS

22 TEST GAG REQUIRED REQUIRED

23 CODE API RP 520 API RP 520

24 BASIS THERMAL EXPANSION THERMAL EXPANSION

25 VESSEL SIZE DIA X T/T TBA TBA

26 FLUID STATE HOT OIL LIQUID HOT OIL LIQUID

27 REQUIRED CAPACITY (VAPOUR/LIQUID)

28 OPERATING S.G MOL. WEIGHT


29 OPER. PRESS SET PRESS 12 12

30 OPER. TEMP REL. TEMP AMB AMB


31 CONSTANT
32 BACK PRESSURE VARIABLE
33 TOTAL
FLUID DATA

34 % ALLOWABLE OVER PRESSURE


35 OVER PRESSURE FACTOR
36 COMPRESSIBILITY FACTOR
37 LATENT HEAT OF VAPORIZATION (KJ/Kg)
38 RATIO OF SPECIFIC HEATS Cp / Cv
39 OPERATING VISCOSITY cP
40 VAPOUR GAS MASS FRACTION
41 BAROMETRIC PRESSURE
42 ENVIRONMENTAL FACTOR
43 VESSEL / WETTED
44 RATED CAPACITY
2
45 CALCULATED AREA inch * *

46 SELECTED AREA inch2 * *

47 ORIFICE DESIGNATION * *

48 MANUFACTURER * *

49 MODEL No. * *

50 NOTES:- * BY VENDOR

51 REFER NOTES SHEET


52
53
54
55
56
57
58
59
DATA SHEET FOR ACTUATED ON OFF VALVES
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR ACTUATED ON OFF VALVES OIL-100-EK-I-DS-0814 A0 Sheet No.: 02 of 06

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS - SDV
6 SDV- LIST
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR ACTUATED ON OFF VALVES OIL-100-EK-I-DS-0814 A0 Sheet No: 03 of 06

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (GGS)
Revision Index
AT EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR ACTUATED ON OFF VALVES OIL-100-EK-I-DS-0814 A0 Sheet No: 04 of 06

Notes:
1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test ,
operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. Orientation of the actuator will be along the pipe axis.
4. Valve body thickness shall be as per ASME B16.34 plus C.A.
5. All instrument painting shall be as per Painting Specification
6. All fastners including stud-bolts and nuts material shall be ASTM A193 Gr. B7/B7M & Heavy hex nuts shall be ASTM A194 Gr. 2H/2HM
with Zinc coated ( hot dipped ) according to ASME B16.5.
7. Air Filter Regulators shall be provided with manual drainage facility, an integral pressure gauge calibrated in barg. Body material shall be
SS316 and filter element is 5 micron size.
8. Flange finish shall be in accordance with ASNI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250 AARH

9. All actuator valves accessories like solenoid valve, filter regulator, etc. shall be mounted on the valve actuator and tubed by vendor
using bright annealed SS316 (ASTM A269) tubing, tube size shall be 10mm O.D. X 1mm W.T.minimum. All tube fittings shall be imperial
and 316 SS double compression type
10. All components such as air filter regulators, limit switches, solenoid valve shall be factory mounted, tubed / wired in completely assemble
condition and bolted to a SS 316 mounting plate which is fixed to a support with SS316 bolts.
11. Spare cable entry shall be plugged with SS316 Ex'd' certified plug.
12. Actuator to be sized for maximum pressure drop equal to the valve design pressure with minimum instrument air supply pressure (5.5 barg).
13. Actuator shall be sized for 1.5 times the required seating torque of the valve when the valve is closed against maximum differential pressure.
14. Actuator shall be supplied with a pressure relief valve to protect the actuator from overpressure if the actuator design pressure is lower
than the maximum instrument air pressure indicated in the datasheet.
17. The valve stem and linkage mechanism shall be consistance with actuator torque characteristic. The maximum torque developed by actuator shall not exceed that
which can be safely sustained by the valve stem. Valve stem or shaft and its trim shall be of blowout proof design and be capable of withstanding the maximum
actuator torque/thrust.
18. The mounting of the actuator shall be suitable for supporting the actuator without external attachments and shall be capable of
resisting actuator's maximum torque force.
19. Limit switches shall be supplied with hermetically sealed NAMUR Inductive proximity switches.
All valves shall be provided with an integral open/close mechanical position indicator(yellow/black) which shall be clearly visible from all angles.
20. Solenoid valve shall have SS 316 body, trim with viton or equal resilient seat (to be anti-explosion decompression type) and surge
suppression diode integrally mounted in enclosure. Open port of solenoid valve shall fitted with a bug screen.
All valves shall be provided with an integral open/close mechanical position indicator(yellow/black) which shall be clearly visible from all angles.
20. Solenoid valve shall have SS 316 body, trim with viton or equal resilient seat (to be anti-explosion decompression type) and surge
suppression diode integrally mounted in enclosure. Open port of solenoid valve shall fitted with a bug screen.
21. Flying leads termination cable are not acceptable for solenoid valve and limit switches.
23. Hydrotest pressure and seat test pressure shall be as per ASME code requirement.
24. Vendor shall verify all sizing calculations to confirm datasheets, selection and shall conform with his quotation. Vendor is responsible to confirm that the
specified pneumatic ON/OFF valve will operate satisfactorily for the given service conditions.
25. Stroke time should not exceed 3 times body size (inches) in seconds or be less than body size (inches) in seconds. Maximum stroke time of any valve is 30 sec.
26. All electrical components shall be suitable for hazardous area with ingress protection IP 65 (min).
27. All Actuated ON/OFF Valve assemblies (valve, actuator, solenoid valve, air pressure regulator and valve position switches) shall be SIL- 2 certified.
28. The Valves above 25Kgs shall be provided with eye bolts as per the requirements for site handling.
29. Valve actuators assemblies shall be equipped with adjustable controls to regulate their stroking speed.
31. All ball valves over 2” shall incorporate anti-static feature ensuring electrical continuity between ball, stem and body.
32. Actuator colour coding shall be fail open valve-Green and fail close valve-Red.
33. All Casting & Welding shall be 100% Radio graphed.
35. Stem for ball valves shall be anti-blowout type and for floating ball valves, seat spring shall be provided.
36. Other auxiliary devices such as air lock relay, pilot relay, booster relay volume tank etc. shall be provided as parts of the actuating system in order to achieve
the required stroke-speed, fail safe action.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR ACTUATED ON OFF VALVES REFER ANNEXURE-1 OIL-100-EK-I-DS-0814
PROJECT DESCRIPTION VME PROJECT No SPECIFICATION No.
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 -
MPC CONTRACTOR SUPPLIER DOC.NO REQUISITION No. SHEET REV
TBA - - 05 of 06 A0
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT DOC .No
-
ORIGINATOR ORIG. DATE
IMR 14-Sep-18
UNITS:- Pressure barg kg/cm2 g kPa g psi g Flow : Gas MMscfd SCMH Sm3/hr kg/hr
0 0
Temp C F Liquid: m3/hr kg./hr bpd USgpm
1 GENERAL 55 ACTUATOR (PNEUMATIC)
QUARTER TURN, SPRING RETURN DOUBLE ACTING
2 FLUID REFER ANNEXURE-1 56 TYPE PISTON
3 LINE No. REFER ANNEXURE-1 57 MFR *

4 P&ID No. REFER ANNEXURE-1 58 SIZE REFER ANNEXURE-1


5 LINE SIZE AND SCHEDULE REFER ANNEXURE-1 59 SPRING ACTION OPEN / CLOSE REFER ANNEXURE-1
6 CORROSION ALLOWANCE REFER ANNEXURE-1 60 MAX ALLOWABLE PRESSURE *
7 PROCESS CONDITIONS 61 MIN REQUIRED PRESSURE *
8 FLOW RATE NA 62 AIR FLUID PRESSURE -
O
9 OP. PRESSURE / OP. TEMP. ( barg/ C) NA 63 AVAILABLE AIR PR. MIN / NOR / MAX. 6 / 8 / 10 barg
10 SPEC. GRAV. NA 64 BREAK TORQUE RUN TORQUE REFER ANNEXURE-3
3
11 LIQ. DENSITY AT OP. PR & TEMP (kg/m ) NA 65 TIME OPEN CLOSE REFER ANNEXURE-3
12 VISCOSITY cP NA 66 ACTUATOR COLOUR YES
O
13 DESIGN TEMPERATURE ( C) REFER ANNEXURE-1 67 ACT ORIENTATION PARALLEL TO FLOW
14 DESIGN PRESSURE (barg) REFER ANNEXURE-1 68 HANDWHEEL TYPE -
15 Dp SHUT-OFF PRESSURE (bar) REFER ANNEXURE-1 69 AIR FAILURE VALVE SET AT -
16 APPLICABLE CODES AND SPECIFICATIONS 70 AIR CONSUMPTION *
17 DESIGN CODE API 6D 71 POSITION INDICATION (LOCAL) YES
18 FIRE-SAFE API-6FA /API 607/ BS 6755 72 POSITION INDICATION (REMOTE) YES - SEE LINES 75~83
19 SEAT LEAKAGE CLASS ANSI FCI 70.2, Class VI or Equal 73 ACCUMULATOR AS REQUIRED BASED ON VALVE TYPE
20 VALVE (NOTE-30,31,32) 74 PNEUMATIC CONNECTION 1/4" NPTF
21 TYPE BALL VALVE 75 SWITCHES
22 SIZE / RATING (in) NB REFER ANNEXURE-1 76 TAG No. REFER ANNEXURE-1
23 FLANGE FACE FINISH REFER ANNEXURE-1 77 TYPE INDUCTIVE PROXIMITY SWITCH WITH NAMUR

24 CONFIGURATION REFER ANNEXURE-1 78 MFR & MODEL *


25 MATERIAL BODY REFER ANNEXURE-1 VALVE CODE 79 CONTACTS / RATING 24VDC @ 2 A
26 BALL REFER ANNEXURE-1 VALVE CODE 80 ACTUATION POINTS OPEN / CLOSE
27 STEM REFER ANNEXURE-1 VALVE CODE 81 ENCLOSURE Ex'ia' / IP 65

28 SEAT RING REFER ANNEXURE-1 VALVE CODE 82 ENCLOSURE MATERIAL SS316


29 SEAT INSERT REFER ANNEXURE-1 VALVE CODE 83 CABLE ENTRY ISO M20 X 1.5 mm (2 nos)
30 FIRE SEAL REFER ANNEXURE-1 VALVE CODE 84 PNEUMATIC PILOT VALVE
31 PACKING REFER ANNEXURE-1 VALVE CODE 85 TAG No.

32 BOLT / NUT REFER ANNEXURE-1 86 TYPE

33 OTHER SPECIFICATIONS - 87 AIR SUPPLY SIGNAL


34 RUN TORQUE BREAK TORQUE ANNEXURE-2 88 MFR & MODEL
35 BODY TEST PRESSURE 1.5 TIMES OF THE DESIGN PRESSURE 89 MANUAL RESET
36 SEAT TEST PRESSURE 1.1 TIMES OF THE DESIGN PRESSURE 90 MATERIAL BODY/HOUSING
37 LIMIT STOPS NO 91 PILOT ACTION
38 MFR * 92 PILOT CONNECTION
39 MODEL * 93 FILTER REGULATOR (NOTE-8)
40 ADDITIONAL INFORMATION 94 MFR & MODEL *
41 a) PNEUMATIC TUBE SIZE ¼” O.D. X 0.035” W.T 95 MATERIAL ENCLOSURE 316 SS IP 65
42 b) ALL CABLE ENTRIES ISO M20 X 1.5 mm 96 INTEGRAL PRESSURE GAUGE YES
43 c) ALL TUBES AND FITTINGS MATERIAL 316 SS, SEE LINES 50 97 DESIGN PRESSURE SET PRESSURE 10 barg *
44 d) AREA CLASSIFICATION ZONE - 2, Gr IIA & IIB, T3 98 PORT SIZE 1/4" NPTF
45 SPEED CONTROLLER LOCAL INDICATOR. YES YES 99 SOLENOID VALVE (NOTE-20,21)
46 100 TAG No. REFER ANNEXURE-1
47 101 QTY REFER ANNEXURE-1
48 102 TYPE 3 / 2 -WAY, UNIVERSAL
49 LIMIT SWITCHES SHALL BE PROVIDED WITH INTEGRAL TERMINAL BLOCK 103 POWER SUPPLY 24 VDC, < 6 WATT, H COIL INSULATION
50 ALL TUBE FITTINGS SHALL BE IMPERIAL AND DOUBLE 104 ENCLOSURE TYPE Ex'd' / IP 65 ZONE - 2, Gr IIA & IIB, T3

51 FERRULE COMPRESSION TYPE. 105 MFR & MODEL *


52 VENT/EXHAUST CONNECTIONS TO BE PROVIDED WITH BUG SCREEN 106 MANUAL RESET YES
53 107 MATERIAL BODY/HOUSING 316 SS
54 108 PORT SIZE CABLE ENTRY 1/4'' NPTF ISO 1/2" NPT(F) X 1.5 mm
NOTES:- * BY VENDOR
Refer Notes sheet
Document Title
Document No. Rev.
DATA SHEET FOR ACTUATED ON OFF CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN
VALVES OIL-100-EK-I-DS-0814 A0 Sheet No.: 06 of 06
LINE SIZE (in) / SCH FLANGE DESIGN LIMIT SWITCH / VALVE
DESIGN ΔP SHUTOFF SOLENOID SOLENOID NACE ACTUATOR
S.NO TAG NO P&ID No. LINE N0. FLUID VALVE SIZE (in) CONFIGURATION or WALL THK. / C.A RATING FINISH VALVE CODE PRESSURE FAIL POSITION LIMIT SWITCH TAG NO. ACTUATOR SIZE BOLT / NUT MATERIAL VALVE MODEL NO SOLENOID VALVE SCHEMATICS REV REMARKS
TEMP. (OC) PRESSURE (bar) VALVE TAG NO. VALVE QTY REQUIREMENT MODEL
(mm) (AARH) (kg/cm2g) MODEL NO NO.
ASTM A 193 Gr. B7 / ASTM A
1 41-SDV-3750 17039-EK-P-DW-0202-13 2"-HM-41-3762-BC01-HC HOT OIL 2" GATE VALVE 2"/ XS/ 3 300# RF 125 - 250 GTBC01R FOW+0.07 108 FOW+0.07 FAIL CLOSE 41-ZSL/ZSH-3750 41-SXV-3750 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


2 41-SDV-3727 17039-EK-P-DW-0203-10 4"-HM-41-3725-BC01-1N HOT OIL 3" GATE VALVE 4"/ STD/ 3 300# RF 125 - 250 GTBC01R 12/FV 250 12/FV FAIL CLOSE 41-ZSL/ZSH-3727 41-SXV-3727 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


3 41-SDV-3730 17039-EK-P-DW-0203-11 3"-HM-41-3727-BC01-1N HOT OIL 3" GATE VALVE 3"/ STD/ 3 300# RF 125 - 250 GTBC01R FOW+0.07 90 FOW+0.07 FAIL CLOSE 41-ZSL/ZSH-3730 41-SXV-3730 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


4 41-SDV-3668 17039-EK-P-DW-0203-14 3"-HM-41-8611-BC01-1N HOT OIL 3" GATE VALVE 3"/ STD/ 3 300# RF 125 - 250 GTBC01R FOW+0.07 90 FOW+0.07 FAIL CLOSE 41-ZSL/ZSH-3668 41-SXV-3668 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

CLARIFIED/ ASTM A 193 Gr. B7 / ASTM A


5 66-SDV-6643A 17039-EK-P-DW-0206-02 4"-TW-66-6604-AC01 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW+0.07 80 FOW+0.07 FAIL CLOSE 66-ZSL/ZSH-6643A 66-SXV-6643A 1 * Not Required * * * * A0
TREATED WATER 194 Gr. 2H (ASME B16.5)

CLARIFIED/ ASTM A 193 Gr. B7 / ASTM A


6 66-SDV-6643B 17039-EK-P-DW-0206-02 4"-TW-66-6604-AC01 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW+0.07 80 FOW+0.07 FAIL CLOSE 66-ZSL/ZSH-6643B 66-SXV-6643B 1 * Not Required * * * * A0
TREATED WATER 194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


7 41-SDV-6623 17039-EK-P-DW-0206-04 2"-HM-41-3674-BC01-1N HOT OIL 2" GATE VALVE 2"/ XS/ 3 300# RF 125 - 250 GTBC01R 15 80 15 FAIL CLOSE 41-ZSL/ZSH-6623 41-SXV-6623 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

OFF-SPEC ASTM A 193 Gr. B7 / ASTM A


8 66-SDV-6640 17039-EK-P-DW-0206-06 4"-WE-66-6605-AC01 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW+0.07 80 FOW+0.07 FAIL CLOSE 66-ZSL/ZSH-6640 66-SXV-6640 1 * Not Required * * * * A0
EFFLUENT WATER 194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


9 53-SDV-5516 17039-EK-P-DW-0212-01 4"-WP-53-5504-AC01 WATER 4" FULL BORE/ FLOATING BALL 4"/ STD/ 3 150# RF 125 - 250 BFAC01R 7/FV 80 7/FV FAIL CLOSE 53-ZSL/ZSH-5516 53-SXV-5516 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


10 53-SDV-5636 17039-EK-P-DW-0212-01 4"-WP-53-5508B-AC01 WATER 4" FULL BORE/ FLOATING BALL 4"/ STD/ 3 150# RF 125 - 250 BFAC01R 7/FV 80 7/FV FAIL CLOSE 53-ZSL/ZSH-5636 53-SXV-5636 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

FRESH POTABLE ASTM A 193 Gr. B7 / ASTM A


11 53-SDV-5607 17039-EK-P-DW-0212-04 3"-WD-53-5534-AS20 3" FULL BORE/ FLOATING BALL 3"/ STD/ 3 150# RF 125 - 250 BFAS20R FOW+0.07 80 FOW+0.07 FAIL CLOSE 53-ZSL/ZSH-5607 53-SXV-5607 1 * Not Required * * * * A0
WATER 194 Gr. 2H (ASME B16.5)

FRESH POTABLE ASTM A 193 Gr. B7 / ASTM A


12 53-SDV-5630 17039-EK-P-DW-0212-04 4"-WD-53-5611A-AS20 4" FULL BORE/ FLOATING BALL 4"/ STD/ 3 150# RF 125 - 250 BFAS20R FOW+0.07 80 FOW+0.07 FAIL CLOSE 53-ZSL/ZSH-5630 53-SXV-5630 1 * Not Required * * * * A0
WATER 194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


13 71-SDV-7101 17039-EK-P-DW-0217-01 4"-WP-71-7101-AC01 WATER 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW 80 FOW FAIL CLOSE 71-ZSL/ZSH-7101 71-SXV-7101 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


14 56-XV-4010 17039-EK-P-DW-0207-01 4"-OW-56-5410-AC01 OILY WATER 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R 11/FV 100 11/FV FAIL CLOSE 56-ZSL/ZSH-4010 56-SXV-4010 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


15 56-XV-4009 17039-EK-P-DW-0207-01 4"-OW-56-4019-AC01 OILY WATER 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R 11/FV 100 11/FV FAIL CLOSE 56-ZSL/ZSH-4009 56-SXV-4009 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


16 71-XV-8008 17039-EK-P-DW-0217-01 2"-WP-53-4639A-AC01 WATER 2" GATE VALVE 2"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW 80 FOW FAIL CLOSE 71-ZSL/ZSH-8008 71-SXV-8008 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


17 71-XV-8009 17039-EK-P-DW-0217-01 2"-WP-53-4639B-AC01 WATER 2" GATE VALVE 2"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW 80 FOW FAIL CLOSE 71-ZSL/ZSH-8009 71-SXV-8009 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

* To be provided by vendor
DATA SHEET FOR MOTOR OPERATED VALVES
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GCS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR MOTOR OPERATED VALVES OIL-100-EK-I-DS-0815 A0 Sheet No.: 02 of 06

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DATA SHEET - MOTOR OPERATED VALVE
6 MOTOR OPERATED VALVE- LIST
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GCS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR MOTOR OPERATED VALVES OIL-100-EK-I-DS-0815 A0 Sheet No: 03 of 06

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (GCS)
Revision Index
AT EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR MOTOR OPERATED VALVES OIL-100-EK-I-DS-0815 A0


Sheet No: 04 of 06

Notes:
1. Documentation required :- Calibration Certificate, Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test ,
operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. MOV shall be designed to be immune to radio frequency & electromagnetic interference with field strength of 15 volts/meter or
less over frequency range of 50 hz to 450 mhz.
4. Motor & control system shall be provided with lightning protection circuits (galvanic isolation via transformer) and shall be
designed and manufactured to operate in 100% or above RH environment.
5. The motor shall be able to operate the actuator at 75% of rated voltage.
6. MOV Actuator operating with AC power supply shall be provided with Phase instantaneous reversal protection.
7. The actuator shall be provided with maximum three adequately sized cable entries viz, one for power cable and two for control cables.
8. Certification for use in Hazardous Area:
(a) VENDOR / SUPPLIER to submit approval certification from CMRI for items manufactured in India.
(b) Certificates from statutory authorities like FM, CSA, UL, CENELEC & ATEX, etc. for items
9. Manual override and handwheel arrangement shall be provided to manually open and close the valve.
10. The MOV actuator shall have an integral control unit, motor starter, control gear, spring-return open/ close push button.
11. Local status indications shall be provided for MOV Open/Close position. Additionally, contacts shall be provided for remote status indication of MOV
Open/Close position.
12. Painting shall be as per Protective Coating specification for Onshore Structures and Facilities.
13. Cable glands shall be double compression explosion proof type made of nickel plated brass, certified for area classification
ZONE 1, GAS GROUP-IIA / IIB, TEMP.CL T3 in case of hazard area, and have an ingress protection of IP65.
14. Local Control Panel is required for Open & close operation & OFF selector switch on MOV actuator. Pull & Push type is required in LCP for open / close.
15. Spare cable entry shall be plugged with Ex'd' certified plug. All cable glands shall be Nickel-plated Brass.
16. The Valves above 25Kgs shall be provided with eye bolts as per requirement for site handling.
17. All MOV Shall be as per API 6D Ball Valve, split body and Floating Ball fro size upto 4" and Trunnion Mounted Ball for size 6" and above.
18. Vendor shall propose the type of cable between Motor Operated Valve to Local control panel and motor control station to MOV.
19. The switches shall be provided with requisite number of potential-free contacts for valve actuator operation and for indication on remote panels.
20. Cable details for 2-wire communication and cable between LCP to MOV shall be provided by VENDOR.
21. 2-Wire Digital Communication With hardwiring feature shall be provided.
22. The motor shall be designed for valve actuator service with high starting torque and shall be suitable for direct on-line starting.
23. The motor shall be provided with thermostat(s)/ thermister(s)/ embedded in the hot spots of motor winding for protecting the motor.
24. The MOV Actuators shall be provided with ‘K-Mass’ type or equivalent fireproofing and the fireproofing shall be rated be rated for 30 minutes.
25. MOV Push button shall be outside the Dyke Area.
26. MOV shall have Open & Close Remote operation from Control room and at Field just outside the Dyke.

REFERENCE DOCUMENTS:
17039-EK-I-DB-8001_Functional specification for package instruments_Rev C
17039-CM-M-SP-2001_Piping material specification_Rev D
17039-CM-M-SP-2002_Valve material specificatio_Rev D
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR MOTOR OPERATED VALVES REFER MOV LIST OIL-100-EK-I-DS-0815
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GCS) AT EAST KHAGORIJAN KIP-17039 05 OF 06 A0
CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A VS 28-Nov-18 PG 28-Nov-18 MV 28-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
VS 28-Nov-18
UNITS:- Pressure barg kg/cm2 g kPa g
Kg/cm2 psi g Flow : Gas MMscfd SCMH Sm3/hr kg/hr
0 0 3
Temp C F Liquid: m /hr kg./hr KLPD USgpm
1 GENERAL 63 ACTUATOR (ELECTRIC)
ELECTRICALLY OPERATED - MULTI TURN,
2 FLUID REFER MOV LIST 64 TYPE
NON INTRUSIVE & SMART
3 SERVICE REFER MOV LIST 65 MOTOR TYPE SQUIRREL CAGE INDUCTION
4 LINE No / P&ID No REFER MOV LIST 66 MFR & MODEL REFER MOV LIST

5 LINE SIZE AND SCHEDULE REFER MOV LIST 67 SIZE / RATING OF MOTOR REFER MOV LIST

6 CORROSION ALLOWANCE REFER MOV LIST 68 MOTOR STARTER INTEGRAL

7 PROCESS CONDITIONS 69 CONTROL SUPPLY 24 VDC


2
8 OP. PRESSURE (kg/cm g) REFER MOV LIST 70 MOTOR INSULATION CLASS F
O
9 OP. TEMP. ( C) REFER MOV LIST 71 MOTOR THERMAL PROTECTION CLASS CLASS B

10 SPEC. GRAV. REFER MOV LIST 72 FAILURE ACTION OPEN / CLOSE REFER MOV LIST
3
11 LIQ. DENSITY AT OP. PR & TEMP (kg/m ) REFER MOV LIST 73 HANDWHEEL REQUIRED

12 VISCOSITY (cP) REFER MOV LIST 74 GEAR TYPE / GEAR RATIO *


O
13 DESIGN TEMPERATURE ( C) REFER MOV LIST 75 TORQUE RANGE *
2
14 DESIGN PRESSURE (kg/cm g) REFER MOV LIST 76 MAX. THRUST *
2
15 DP SHUT-OFF PRESSURE (kg/cm g) REFER MOV LIST 77 ROTATION CLOCKWISE TO OPEN

16 APPLICABLE CODES AND SPECIFICATION 78 SPEED *

17 DESIGN CODE API 6D , API 598 79 MOUNTING POSITION TOP

18 FIRE SAFE API 607 , API 6FA 80 ELECTRIC FAILURE STAY PUT

19 81 MECHANICAL BRAKE NOT REQUIRED

20 VALVE 82 SEALING TORQUE *

21 TYPE BALL TYPE, FIRE SAFE & NON RUBBING 83 BREAK AWAY TORQUE *

22 SIZE / RATING (in) REFER MOV LIST 84 RUNNING TORQUE *

23 CHARACTERISTIC / CONTRL RANGE ON-OFF 85 OPENING / CLOSING TIME < 60 SEC

24 VALVE DUTY FULLY OPEN & FULL CLOSE 86 TORQUE / LOAD CURRENT *
25 FLANGE FACE FINISH 125 to 250 in AARH 87 CONSTRUCTION FLAME PROOF

26 MATERIAL : BODY ASTM A216 Gr.WCB 88 FULL CURRENT (AMPS) *

27 BONNET ASTM A216 Gr.WCB 89 STARTING CURRENT *

28 BALL & STEM F316 SS (or) ENP A105 CS & A182 F316 90 NUMBER OF STARTS / HOUR 60 STARTS / HOUR

29 SEAT / BODY SEAT RING PEEK 91 REVERSING CONTACTOR YES

30 ANSI / FCI LEAKAGE CLASS CLASS IV 92 CONTROL TRANSFORMER YES

31 STEM PACKING / GASKET EXPANDED GRAPHITE + GRAPHOIL FILLER 93 OVERLOAD PROTECTION YES

ASTM A 193 Gr. B7 / ASME B16.5 &


32 BOLT & NUT 94 ENCLOSURE Ex'd'
ASTM A 194 Gr. 2H / ASME B16.5
33 HAND WHEEL MALLEABLE IRON / DUCTILE IRON / CAST STEEL / FAB. ST. 95 SYSTEM EARTHING SOILDLY EARTHED

CONTACTORS / SELECTOR SWITCH &


34 PORT TYPE FULL PORT 96 *
PUSH BUTTON MAKE

35 SPEED OF OPERATION (DESIGN / ACTUAL) * 97 SWITCHES

36 BODY TEST PRESSURE 1.5 TIMES OF THE DESIGN PRESSURE 98 TAG No. -

37 SEAT TEST PRESSURE 1.1 TIMES OF THE DESIGN PRESSURE 99 TYPE INTERNAL VOLT FREE CONTACT
38 TORQUE LIMIT STOPS YES 100 MFR & MODEL REFER MOV LIST

39 MANUFACTURER REFER MOV LIST 101 CONTACTS / RATING 1 A at 2V DC

40 MODEL REFER MOV LIST 102 ACTUATION POINTS OPEN / CLOSE

41 QUANTITY REFER MOV LIST 103 ENCLOSURE Ex'd' / IP 65 INBUILT WITH ACTUATOR

42 104 ENCLOSURE MATERIAL DIE-CAST ALUMINUM

1/2" NPT (M) DOUBLE COMPRESSION /


43 ADDITIONAL INFORMATION 105 CABLE ENTRY / MATERIAL
NICKEL PLATED BRASS

44 a) ALL CABLE ENTRIES 1/2" NPT (M) DOUBLE COMPRESSION / NICKEL PLATED BRASS 106 DUTY RATING

45 b) AREA CLASSIFICATION REFER MOV LIST 107 VOLT / FREQ / PH. 415 VAC ±10% / 50HZ ±3% / 3 PHASE

46 SPEED CONTROLLER / LOCAL INDICATOR. NA REQUIRED 108 DUTY RATING S2-15 min.

OTHER ACCESSORIES COMPLETELY ASSEMBLED FOR THE CORRECT AND SATISFACTORY


47 109 CONTROL FEATURES
OPERATION OF MOV

48 OPERATION - REFER LINES 51 ~ 123 110 LOCAL CONTROL PANEL REFER MOV LIST

49 111 EMERGENCY PUSH BUTTON YES

50 OPTIONS 112 SELECTOR SWITCH YES

51 MANUAL OPERATOR YES 113 SELECTOR SWITCH INDICATION OPEN / CLOSE / REMOTE

52 HAND WHEEL TURNS / RATIO * 114 REMOTE AND LOCAL CONTROL YES (OPEN / CLOSE)

53 LOCKED DECLUTCH LEVER YES 115 FAULT RELAY YES

54 INPUT SIGNAL YES 116 INTERPOSING RELAY NO


MECHANICAL DISPLAY & LCD DISPLAY ON
55 OUTPUT SIGNAL YES 117 VALVE POSITION INDICATION
MOV
56 VALVE POSITION TRANSMITTER YES 118 MOTOR TEMPERATURE ALARM YES

57 FIRE SAFE REQUIREMENTS YES 119 LIMIT SWITCH & TORQUE SWITCH YES

58 FAIL SAFE CONDITION REFER MOV LIST 120 SIL CERTIFICATION -

59 121 INTERFACING WITH BPCS REFER MOV LIST


HOT STANDBY MASTER CONTROL
60 122 REQUIRED
STATION IN CONTROL ROOM

61 123 ACTUATOR WIRING FEATURE REFER MOV LIST

62 124
63 NOTES:- * - TO BE CONFIRMED BY VENDOR
64 Refer Notes sheet
Document Title Document No Rev

CREATION OF SURFACE PRODUCTION FACILITIES (GCS) AT EAST KHAGORIJAN


DATA SHEET FOR MOTOR OPERATED VALVES OIL-100-EK-I-DS-0815 A0 Sht.No: 06 of 06

LOCAL VALVE LIMIT ACTUATOR


DESIGN DP SHUT-
LINE SIZE (in) CONTROL OP. OP. DESIGN LIQ. DENSITY MAKE SWITCH (ELECTRIC) SIZE /
LINE NO / PIPE LINE STEAM PRESSURE FAIL INTERFACING PRESSURE SPECIFIC VISCOSITY OFF
S.NO TAG NO. SERVICE DESCRIPTION FLUID / PHASE INSTRUMENT TYPE AREA CLASSIFICATION P&ID NO / SCH / C.A PANEL WITH PRESSURE TEMP. TEMPERATURE AT OP. PR & & MAKE MAKE RATING OF REMARKS
EQUIPMENT NO. INSULATION TRACING RATING ACTION WITH BPCS O IN kg/cm2 0 GRAVITY (cP) PRESSURE
(mm) PUSH (kg/cm2g) ( C) IN C TEMP (kg/m3) MODEL & & MOTOR
(kg/cm2g)
BUTTON NO MODEL NO MODEL NO

MOTOR OPERATED VALVE LIST

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0202- FAIL NOT


1 20-MOV-0303 Well Fluid from Test Separator Well Fluid/ Liquid 2"-PT-20-0205-FC01 2"/ XXS/ 3mm NO YES 2500# RTJ YES 5-90 27-50 100/FV 100 0.87 870 10.7 100 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 13 LAST REQUIRED

Crude Oil from Test Tank To Test Tank MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0202- FAIL NOT
2 20-MOV-3750 Crude Oil/ Liquid 4"-PL-44-1380-AC01 4"/ STD/ 3mm NO NO 150# RF YES ATM 27-50 FOL+0.07 90 0.87 870 10.7 FOL+0.07 * * * */ 3-Phase
Transformer Pump VALVE IIB, TEMP.CL T3 13 LAST REQUIRED

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0203- 4"-PL-20-0811A- FAIL NOT


3 20-MOV-0979A Crude to Treated Crude Storage Tank Crude Oil/ Liquid 4"/ STD/ 3mm NO NO 150# RF YES 10 55 15 90 0.87 870 10.7 15 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 10 AC01 LAST REQUIRED

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0203- FAIL NOT


4 20-MOV-0980 Treated Crude to Crude Charge Pump Crude/ Liquid 6"-PL-20-0822-AC01 6"/ STD/ 3mm NO YES 150# RF YES ATM 55 FOL+0.07 90 0.87 870 10.7 FOL+0.07 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 10 LAST REQUIRED

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0203- FAIL NOT


5 20-MOV-0978A Crude to Treated Crude Storage Tank Crude/ Liquid 4"-PL-20-0816-AC01 4"/ STD/ 3mm NO YES 150# RF YES ATM 55 FOL+0.07 90 0.87 870 10.7 FOL+0.07 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 10 LAST REQUIRED

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0203- FAIL NOT


6 20-MOV-0978B Treated Crude from crude exchanger Crude/ Liquid 4"-PL-20-0818-AC01 4"/ STD/ 3mm NO YES 150# RF YES ATM 55 FOL+0.07 90 0.87 870 10.7 FOL+0.07 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 11 LAST REQUIRED

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0203- 4"-PL-20-0811B- FAIL NOT


7 20-MOV-0979B Crude from crude dispatch pump PSV Crude/ Liquid 4"/ STD/ 3mm NO NO 150# RF YES ATM 55 FOL+0.07 90 0.87 870 10.7 FOL+0.07 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 11 AC01 CLOSE REQUIRED

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0203- FAIL NOT


8 20-MOV-0981 Treated Crude to Crude Charge Pump Crude/ Liquid 6"-PL-20-0825-AC01 6"/ STD/ 3mm NO YES 150# RF YES ATM 55 FOL+0.07 90 0.87 870 10.7 FOL+0.07 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 11 LAST REQUIRED

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0203- FAIL NOT


9 20-MOV-1120 Crude to Crude Circulation pumps Crude/ Liquid 8"-PL-20-0459-AC01 8"/ 20/ 3mm NO YES 150# RF YES ATM 55 FOL+0.07 90 0.87 870 10.7 FOL+0.07 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 14 LAST REQUIRED

Crude from Closed Drain Tfr./ Crude


MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0203- FAIL NOT
10 20-MOV-1119A Exchanger/ Flare Recovery Pumps/ Oil Crude Oil/ Liquid 6"-PL-20-0458-AC01 6"/ STD/ 3mm NO YES 150# RF YES 5 55 10 90 0.87 870 10.7 10 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 14 LAST REQUIRED
Tfr. Pumps

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0203- FAIL NOT


11 20-MOV-1119B From Crude circulation pumps Crude Oil/ Liquid 3"-PL-20-0391-AC01 3"/ STD/ 3mm NO YES 150# RF YES 10 55 15 90 0.87 870 10.7 15 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 14 LAST REQUIRED

Skim Oil from Effluent treatment MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0206- FAIL NOT
12 66-MOV-6612 Skim Oil/ Liquid 2"-PL-66-6603-AC01 2"/ XS/ 3mm NO NO 150# RF YES ATM 55 FOL+0.07 90 0.87 870 10.7 FOL+0.07 * * * */ 3-Phase
package VALVE IIB, TEMP.CL T3 04 LAST REQUIRED

MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0206- FAIL NOT


13 66-MOV-6623 Skim Oil To Skim Oil Transfer Pumps Skim Oil/ Liquid 2"-PL-66-6635-AC01 2"/ XS/ 3mm NO NO 150# RF YES ATM 55 FOL+0.07 90 0.87 870 10.7 FOL+0.07 * * * */ 3-Phase
VALVE IIB, TEMP.CL T3 04 LAST REQUIRED

LOCAL CONTROL
MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0219- FAIL
14 20-MOV-2004 Metering Skid Inlet Crude Oil/ Liquid 3"-PL-20-2402-AC01 3"/ STD/ 3mm NO NO 150# RF REQUIRED YES 10 55 15 90 0.87 870 10.7 15 * * * */ 3-Phase PANEL WITH
VALVE IIB, TEMP.CL T3 01 CLOSE
PUSH BUTTON
LOCAL CONTROL
MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0219- FAIL
15 20-MOV-2005 Metering Skid Inlet Crude Oil/ Liquid 3"-PL-20-2403-AC01 3"/ STD/ 3mm NO NO 150# RF REQUIRED YES 10 55 15 90 0.87 870 10.7 15 * * * */ 3-Phase PANEL WITH
VALVE IIB, TEMP.CL T3 01 CLOSE
PUSH BUTTON
LOCAL CONTROL
MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0219- FAIL
16 20-MOV-2006 Metering Skid Inlet Crude Oil/ Liquid 3"-PL-20-2404-AC01 3"/ STD/ 3mm NO NO 150# RF REQUIRED YES 10 55 15 90 0.87 870 10.7 15 * * * */ 3-Phase PANEL WITH
VALVE IIB, TEMP.CL T3 01 CLOSE
PUSH BUTTON
LOCAL CONTROL
MOTOR OPERATED ZONE 1, GAS GROUP-IIA/ 17039-EK-P-DW-0219- FAIL
17 20-MOV-2007 Metering Skid Inlet Crude Oil/ Liquid 3"-PL-20-2405-AC01 3"/ STD/ 3mm NO NO 150# RF REQUIRED YES 10 55 15 90 0.87 870 10.7 15 * * * */ 3-Phase PANEL WITH
VALVE IIB, TEMP.CL T3 01 CLOSE
PUSH BUTTON

Page 3 of 5
DATA SHEET FOR FLOAT AND BOARD TYPE LEVEL
INDICATOR
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code
DATA SHEET FOR FLOAT AND BOARD TYPE LEVEL
INDICATOR OIL-100-EK-I-DS-0816 A0 Sheet No.: 02 of 05

INDEX SHEET

SHEET No. TITLE

1 COVER SHEET

2 INDEX SHEET

3 REVISION SHEET

4 NOTES SHEET

5 DATA SHEET FOR FLOAT AND BOARD TYPE LEVEL INDICATOR


Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code
DATA SHEET FOR FLOAT AND BOARD TYPE LEVEL
INDICATOR OIL-100-EK-I-DS-0816 A0 Sheet No: 03 of 05

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY

A0 ISSUED FOR REVIEW FIRST ISSUE


CREATION OF SURFACE PRODUCTION FACILITIES (GGS) Revision Index
AT EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR FLOAT AND BOARD TYPE LEVEL INDICATOR


OIL-100-EK-I-DS-0816 A0 Sheet No: 04 of 05

Notes:
1. Documentation required :- Calibration Certificate , Material Certificates to 3.1 as per EN 10204, Hydro test ,

Pressure test Procedure/Report , Operating & Maintenance Instructions & Spare Parts List.

2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.

3. All stud bolt material shall be ASTM A 193 Gr. B7 & Heavy hex nuts shall be ASTM A194 Gr. 2H.

4. All weldings & castings (if any) shall be 100% radiographed.

5. Painting shall be Manufacturer standard suitable to all aggressive environment.

6. Sufficent float and guide wire to be supplied on single length to cut at site as per requirement.

7. The pointer is in `TOP POSITION' when tank is `EMPTY' and in `BOTTOM POSITION' when `FULL'. Pointer indicates 'Level'.

8. The gauge board is supplied in 1mtr sections and multiple gauge boards are connected through gauge brackets as per ordered measuring range.

REFERENCE DOCUMENTS:

17039-EK-I-DB-8001_Functional specification for package instruments_Rev C


TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR FLOAT AND BOARD TYPE LEVEL INDICATOR AS BELOW OIL-100-EK-I-DS-0816
PROJECT DESCRIPTION PROJECT NO. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) KIP-17039 05 OF 05 A0
AT EAST KHAGORIJAN
EPC CONTRACTOR PURCHASE ORDER No. REQUISITION NO. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 29-Nov-18 PGN 29-Nov-18 MV 29-Nov-18 ISSUED FOR REVIEW
CLIENT DOC NO
-
ORIGINATOR ORIG. DATE
VS 29-Nov-18
UNITS:- Pressure barg kg/cm 2 g kPa g psig Level: mm

Temp °C
1 TAG No. 71-LI-8005 71-LI-8004

2 TYPE FLOAT & BOARD FLOAT & BOARD

3 P&ID No. 17039-EK-P-DW-0217-01 17039-EK-P-DW-0217-01

4 SERVICE FIRE WATER STORAGE TANK FIRE WATER STORAGE TANK

GENERAL 5 VESSEL No. EK-ABJ-3110A EK-ABJ-3110B

6 TANK ROOF TYPE VERTICAL CONE ROOF VERTICAL CONE ROOF

7 TANK HEIGHT mm 10000 10000

8 NOZZLE HEIGHT mm 150 (FROM TOP OF TANK) 150 (FROM TOP OF TANK)

9 FLUID STATE FIRE WATER FIRE WATER

10 PRESS MAX. NOR. FOW+0.07 / ATM FOW+0.07 / ATM

PROCESS 11 TEMP. MAX. NOR. 80 / 41 80 / 41

CONDITIONS 12 SPEC. GR. 1 1

13 VISCOSITY cP 1 1

14 TYPE LEVEL INDICATOR LEVEL INDICATOR

15 QUANTITY 1 1

16 SCALE RANGE mm 0 - 10000 0 - 10000

17 LOCAL INDICATION CALIBRATED GAUGE BOARD CALIBRATED GAUGE BOARD

GAUGE BOARD 18 MOUNTING SIDE MOUNTED SIDE MOUNTED

19 TEST PRESSURE - -

20 CONN. SIZE :TYPE & RATING 3 No's 1 1/2" 150#RF 3 No's 1 1/2" 150#RF

21 ENCLOSURE PROTECTION IP 65 IP 65

22 SPRING ASSEMBLY SPRING STEEL SPRING STEEL

23 DRIVE BUSHING - -

24 TAG NO. - -

25 SWITCH CONTACTS - -

SWITCHES 26 CONTACT RATING - -

27 CABLE ENTRIES - -

28 ENCLOSURE PROTECTION - -

29 AREA CLASSIFICATION - -

30 LEVEL GAUGE / GAUGE HEAD CAST ALUMINUM (EPOXY COATED) CAST ALUMINUM (EPOXY COATED)

31 PIPE MOUNTING PARTS SS 316 SS 316

32 TOP ANCHOR ASSEMBLY SS 316 SS 316

33 ELBOW CAST ALUMINUM (EPOXY COATED) CAST ALUMINUM (EPOXY COATED)

MATERIAL 34 FLOAT & PULLEY SS 316 SS 316

35 GUIDE WIRE KNOB SS 316 SS 316

36 TAPE / WIRE SS 316 SS 316

37 BOTTOM ANCHOR ASSEMBLY SS 316 SS 316

PERFORMANCE 38 ACCURACY ± 2mm ± 2mm

39 REPEATABILITY - -

40

41 NEGATOR CASSETTE NO NO

42 CONDUITS ELBOWS YES YES

OPTIONS 43 SUPPORT BRACKETS YES YES

44 INSPECTION HATCHES NO NO

45

OTHERS 46 MANUFACTURER * *

47 MODEL * *
NOTES :
REFER NOTES SHEET
DATA SHEET FOR FLOW ELEMENT (ORIFICE)
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATASHEET - FLOW ELEMENT (ORIFICE) OIL-100-EK-I-DS-0817 A0 SHEET 02 OF 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 71-FE-7266
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATASHEET - FLOW ELEMENT (ORIFICE) OIL-100-EK-I-DS-0817 A0 SHEET 03 OF 05

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATASHEET - FLOW ELEMENT (ORIFICE) OIL-100-EK-I-DS-0817 A0 SHEET 04 OF 05

NOTES SHEET

1 Documentation required :- Calibration Certificate,Material Certificates to 3.1 as per EN10204, weather proof certificate, Pressure test
procedure/Report, NDT Procedure/ report, Operating & Maintenance Instructions & Spare Parts List.
1 The upstream side of the orifice plate tab handle shall be permanently marked “UPSTREAM”.
2 The downstream side of the orifice plate tab handle shall be permanently marked Instrument tag number,Orifice bore diameter in mm,
Line size ( in mm ) and flange rating( in ANSI ),Plate material.
3 Orifice Flanges shall be in accordance with ANSI B 16.36 & ANSI class 300 rated as minimum.
4 The beta ratio (d/D) shall be kept in between 0.2 and 0.7.
5 Normal flow rates shall be calculated in such a way that its value is approximately 70% to 80% of design flow.
6 Orifice plate for ring-type joint flanges shall be supplied with plate carrying holders.
7 Orifice plates shall be bored for the maximum flow that will give an even meter factor or Meter max.
8 Each flange shall have two pressure taps to facilitate ease of installation. One of the pressure taps shall be provided with 1/2" NPTM plug.
9 The given minimum flowrate is based on 30% turndown of normal flowrate.
10 Design life of all instruments shall be 20 years.
11 Minimum, normal and maximum ambient temperaures are 8°C, 28°C & 38°C.
12 Flow element sizing calculation shall be as per ISO 5167. For gas measurements, the sizing and Installation shall beAGA 3 /AGA 8 report.
13 Orifice assembly shall include supply of plates, flanges, stud, bolts, nuts, jack screw, gasket / plate, holder & plugs.
14 All stud bolt material shall be Zinc coated (hot dipped) according to ASTM A153.

HOLD:
1 Design pressure & design temperature.
TITLE ITEM/TAG No. DATA SHEET No.
DATASHEET - FLOW ELEMENT (ORIFICE) REFER BELOW OIL-100-EK-I-DS-0817
PROJECT DESCRIPTION VME PROJECT No SPECIFICATION No.
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 -
EPC CONTRACTOR REQUISITION No. SHEET REV
TBA - 05 of 05 A0
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 29-Nov-18 MV 29-Nov-18 MSR/ VSR 29-Nov-18 ISSUED FOR REVIEW
CLIENT DOC .No
-

ORIGINATOR ORIG.DATE
IMR 17-Sep-18
UNITS: Pressure: kg/cm2 g Temp: °C Flow: Gas: - Liquid: m3/hr

1 ORIFICE PLATES 10 ORIFICE FLANGES


2 TYPE CONCENTRIC OTHER SQUARE EDGE PADDLE 11 TAPS FLANGE CORNER
3 STANDARD ISO 5167 OTHER (AGA REPORT 3) 12 PIPE OTHER
4 BORE MAXIMUM RATE NEAREST 1/8 in. 13 TAP SIZE 1/2"NPTF OTHER
5 MATERIAL SS 304 SS 316 OTHER 14 TYPE WELD NECK FLANGENECK
6 RING MATERIAL SS316 15 SLIP-ON THREADED
7 16 MATERIAL CARBON STEEL
8 17 FLANGES INCLUDED BY OTHERS
9 18 RATING 300# RF
10 TAG NO. 71-FE-7266

11 FIRE WATER FR.FW PUMP DISCAHRGE (TEST


SERVICE LINE)
GENERAL

12 P & ID No. 17039-EK-P-DW-0217-01


13 LINE No. 8"-WF-71-7108-AG01
14 LINE SIZE/SCH 8" / HVY
15 LINE INSULATION NO
16 NACE Not Required
17 FLUID TYPE LIQUID
18 SUSPENDED SOLIDS -
19 PRESSURE (MAX. / NORM. / MIN. ) - ATM -
20 TEMPERATURE (MAX. / NORM. / MIN.) - 41 -
21 DESIGN (PRESS / TEMP.) FOW 80
22 SPECIFIC GRAVITY BASE | OPERATING - 0.541
SERVICE CONDITIONS

23 BASE PRESSURE
24 BASE TEMPERATURE
25 ALLOWABLE PRESS. DROP ACROSS METER (kg/cm2)
26 FLUID VISCOSITY cP 0.64
27 DENSITY kg/m 3
MOLECULAR WEIGHT 995.4

28
VAPOUR PRESSURE / PULSAION / STEADY FLOW 1.116 psia - -
29 PERMANENT PRESSURE LOSS -
30 FLOW (MIN / NORMAL / MAX) 410 m3/hr -
31 VELOCITY (MIN / NOR / MAX) -
32 SPECIFIC HEAT RATIO (Cp/Cv) -
33 COMPRESSIBILITY FACTOR (Z) -
34 CORROSIVE COMPONENT (MOLE FRACTION) N/A
35 TYPE OF METER DIFFERENTIAL PRESSURE
36 DIFF. RANGE-DRY ( mbar) 0-250
37 SEAL SP. GR AT 60 deg F -
38 STATIC PRESSURE RANGE -
METER

39 CHART or SCALE RANGE -


40 CHART MULTIPLIER -
41 METER MAX. m3/hr 0 - 450
42 BETA =d/D *
43 ORIFICE BORE DIAMETER mm *
44 LINE I.D mm 206.37
45 FLANGE RATING 300# RF
PLATE & FLANGE

46 FLANGE MATERIAL ASTM A105, CS hot dip Galvanized


47 PLATE THICKNESS (mm) *
48 STUD & BOLT MATERIAL ASTM A 193 Gr. B7 / ASME B16.5 (Hot dip galvanized)
49 GASKET MATERIAL SP.WND SS316 + CNAF
50 RING TYPE & NO. -
51 STRAIGHT LENGTH -
52 FLOW COMPUTER -
OPTIONS
OTHER

53 FLOW STRAIGHTENER -
54 MODEL NO. FOR PLATE *
55 MANUFACTURER *
56 NOTES: * BY VENDOR
57 REFER NOTES SHEET
58
DATA SHEET FOR DP TYPE LEVEL TRANSMITTER
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR DP TYPE LEVEL TRANSMITTER OIL-100-EK-I-DS-0818 A0 Sheet No.: 02 of 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DATA SHEET FOR DP TYPE LEVEL TRANSMITTER
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR DP TYPE LEVEL TRANSMITTER OIL-100-EK-I-DS-0818 A0 Sheet No: 03 of 06

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT
EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR DP TYPE LEVEL TRANSMITTER OIL-100-EK-I-DS-0818 A0 Sheet No: 04 of 05

Notes:

1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test , Explosion proof & weathe
proof certificate, Pressure test Procedure/Report , Operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. All transmitters shall be provided with integral indicator (LCD type) with engineering unit indicating total level in mm & %.
4. Instrumentation shall meet the Electromagnetic interference requirements according to EN 50081-2 and EN 50082-2.
5. All field transmitters shall be" SMART" type, 2-wire 24VDC loop powered communicating on 4-20mA signal mode with superimposed
HART digital transmission signal for remote calibration and diagnostics from HART maintenance system.
6. Flange finish shall be in accordance with ANSI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250 AARH and 63 AARH for Ring type joint (RTJ
7. The housing of all transmitters shall be SS 316 minimum and suitable for aggressive offshore environment.
8. Certified plug shall be provided for spare cable entry.
9. All Transmitters shall be provided with SIL-2 (min) certification.
10. The over-range/static pressure protection of the transmitter shall be 130% of range.
11. Painting shall be Manufacturer standard suitable to all aggressive environment.
12. The design of electronic instruments shall be in compliance with the electromagnetic compatibility requirements as per IEC-61000-4.

REFERENCE DOCUMENTS:
17039-EK-I-DB-8001_Functional specification for package instruments_Rev C
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR DP TYPE LEVEL TRANSMITTER SEE BELOW TABLE OIL-100-EK-I-DS-0818
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 05 A0
CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 29-Nov-18 MV 29-Nov-18 PG 29-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
VS 29-Nov-18

UNITS: Pressure: kg/cm2 g Temp: ° C

GENERAL

1. Mounting Remote (2" Pipe Mounted) 8. Zero Suppression Required


2. Accuracy ± 0.25% of Span 9. Zero Elevation Required
3. Over Pressure Limit * 10. Zero Adjust Location External
4. Ambient Temp. Limit 8 to 38°C 11. Span Adjust Location External
5. Output 4-20 mAdc, HART Protocol with SMART Tr. 12. Enclosure Rating IP 65
6. Power Supply 24 VDC Loop powered 13. Area Classification Zone 2, Gas Group IIA&IIB, T3
7. Indicating Yes, LCD in engineering unit 14. Equipment Certification Ex 'ia'

CONSTRUCTION
1. Service Level 11. Housing Material Polyurethane Coated Aluminum
2. Process connetion 2" Flange, 150# RF ANSI, 316SS 12. Xmtr Diaphragm. Material SS 316
3. Electrical Connection 1/2" NPT(F) 13. O-Ring Material Glass-Filled PTFE
4. Mounting Bracket Yes, For 2" Pipe 14. Sensor Fill Fluid Silicone Oil
5. Process Seal Type Diaphragm 15. Diaphragm Seal Material N/A
6. Hydrotest Req'd Yes 16. Capillary Material N/A
7. Diaphragm Seal No 17. Drain/Vent Material SS 316
8. Capillary Length N/A 18. Flange Bolt Material SS 316
9. Capillary Fill Fluid N/A 19. Bracket Bolt Material SS 316
Yes (1/4" Drain connection pipe
10. Drain / Vent plug 20. SIL Compliance SIL-2
supplied with Manifold) 21. Manufacturer *

NOTES
1) Each instrument shall include a SS 316 tag permanently attached to the instrument using SS 316 screws, SS 316 bolts or ss 316 wire.
2) Transmitter un-used conduit entry shall be plugged with certified Ex'd' Plug.
3) Painting shall be Manufacturer standard suitable for Hazardous environment.
4) All Level transmitters (DP type) shall be provided with 5 valve manifold.
5) For General notes refer Notes section.

Instrument Calibrated C-C Operating Design Design


Operating Density specific Model
S.No. Tag Number Service Description P&ID Number Range Range DIST. pressure pressure Temp. Remarks
Temp. (°C) (kg/m3) gravity Number
in mmH20 in mm (mm) (Kg/cm2) (Kg/cm2) (°C)

Industrial Water Storage Tank (EK-


1 53-LIT-5512 17039-EK-P-DW-0212-01 * 2500 0 - 2500 ATM FOW+0.07 AMB 80 1000 1 * -
ABJ-3220)

Industrial Water Storage Tank (EK-


2 53-LIT-5513 17039-EK-P-DW-0212-01 * 2500 0 - 2500 ATM FOW+0.07 AMB 80 1000 1 * -
ABJ-3220)

Potable wate storage tank


3 53-LIT-5538 17039-EK-P-DW-0212-04 * 2500 0 - 2500 ATM FOW+0.07 AMB 80 1000 1 * -
(EK-ABJ-3270)

Potable wate storage tank


4 53-LIT-5541 17039-EK-P-DW-0212-04 * 2500 0 - 2500 ATM FOW+0.07 AMB 80 1000 1 * -
(EK-ABJ-3270)

* To be Provided By Vendor.
DATA SHEET FOR FLOW INDICATOR (ROTAMETER)
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (GGS)
Rev
AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR FLOW INDICATOR (ROTAMETER) OIL-100-EK-I-DS-0819 A0 SHEET 02 OF 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS-FI (ROTAMETER)
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT
Rev
EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR FLOW INDICATOR (ROTAMETER) OIL-100-EK-I-DS-0819 A0 SHEET 03 OF 05

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT
Rev
EAST KHAGORIJAN Datasheet Number Code

DATA SHEET FOR FLOW INDICATOR (ROTAMETER) OIL-100-EK-I-DS-0819 A0


Sheet No.: 04 of 05
Notes Sheet

1. Documentation required :- Calibration certificate, Material certificates to 3.1 as per EN10204, weather proof to IP66 certificate by ATEX or Equivalent body, Pressure
test procedure/Report, Hydrostatic Test Report, GAD Wiring diagram, Operating and Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. The metering tube shall have self-guided floats, with top and bottom float stops.
4. An arrow mark indication of flow shall be marked on the body.
5. All stud bolt material shall be ASTM A 193 Gr. B7 / ASME B16.5 (Hot dip galvanized).
6. Float shall have dimensional stability and shall not respond to variations in viscosity.
7. Indicating scales shall have full length safety glass with shields and gaskets on both sides.
8. Armoured meters shall have a metal tube with magnetically coupled integral indicator.
9. The range of the Rotameter shall be selected such that the normal flow rate is between 50% and 70% of the instrument range.
10. The flow rate shall be indicated by the vertical position of the float or magnetically coupled pointer.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR FLOW INDICATOR (ROTAMETER) REFER BELOW OIL-100-EK-I-DS-0819
PROJECT DESCRIPTION PROJECT NO. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 05 A0
EPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 29-Nov-18 MV 29-Nov-18 MSR/VSR 29-Nov-18 Issued For Review
CLIENT DOC.No:
-
ORIGINATOR ORIG. DATE
IMR 28-Sep-18
UNITS:- Pressure bar g kg/cm2 g kPa g psi g Flow: Liquid LPH m3/hr USgpm
0 0
Temp C F Gas Sm3/hr SCFM MMscfd
1 TAG NO. 42-FI-3910 42-FI-3912

Water scale inhibitor injection pumps (EK- De-oiler injection pumps


2 SERVICE
PBA-5130A/B) outlet ( EK-PBA-5090A/B) Outlet

3 LINE No. 1/2"-CS-42-3879-GT20 1/2"-CS-42-3900-GT20


4 P &ID No. 17039-EK-P-DW-0206-01 17039-EK-P-DW-0206-01
5 LINE SIZE/SCH 1/2"/ SCH 160 1/2"/ SCH 160
6 FUNCTION FLOW MEASUREMENT (LOCAL INDICATION) FLOW MEASUREMENT (LOCAL INDICATION)
GENERAL 7 MOUNTING INLINE INLINE
8 POWER SUPPLY N/A N/A
9 CONN. SIZE TYPE 1/2"NPTF THREADED 1/2"NPTF THREADED
10 INLET DIR. OUTLET DIR. VERTICAL BOTTOM VERTICAL TOP VERTICAL BOTTOM VERTICAL TOP
11 FLANGE/FITTING MATERIAL - SS 316 - SS 316
12 PACKING or O-RING MATERIAL MFR STD. MFR STD.
13 ENCLOSURE MATERIAL SS 316 SS 316
14 SIZE FLOAT GUIDE 1/2" SS 316 1/2" SS 316
15 TUBE MATERIAL FLOAT MATL. SS 316 SS 316 SS 316 SS 316
16 METER SCALE: LENGTH & TYPE DIRECT READING (LINEAR) DIRECT READING (LINEAR
METER 17 METER SCALE RANGE m3/hr * *
18 METER FACTOR 10 10
19 RATED ACCURACY ±2 % OF FULL SCALE READING ±2 % OF FULL SCALE READING
20 ENCL. PROTECTION IP 65 IP 65
21 FLUID Chemical, Water Scale Inhibitor Chemical, De-Oiler
22 COLOUR or TRANSPARENT TRANSPARENT TRANSPARENT
23 MAXIMUM FLOW RATE
24 NORMAL FLOW MIN FLOW 0.9 lit/hr 1.4 lit/hr
FLUID 25 OPERATING SG MW
DATA 26 MAX. OPERATING VISCOSITY cP
27 OP. PRESS./TEMP. 6.5 AMB 6.5 Amb
28 LIQUID DENSITY lb/ft3
29 STD DENSITY kg/m³ 1000 980
30 MAX. ALLOWABLE PRESS DROP kg/cm2 0.1 0.1
31 DESIGN PRESSURE/TEMP. kg/cm2 /°C 10 80 10 80
EXT 32 EXTENSION WELL MATERIAL
33 STUD, BOLT &GASKET MATERIAL
34 TRANSMITTER OUTPUT
XMTR 35 TRANS. ENCLOSURE CLASS
36 HAZARDOUS AREA
37 LOCAL INDICATION YES YES
INDICATOR
38 DIAL SIZE MFD STD MFD STD
39 NO. OF CONTACTS
ALARM 40 RATING
41 ACTION
42 VALVE SIZE & MATERIAL - -
43 VALVE LOCATION - -
44 CONST. DIFF. RELAY MATERIAL - -
OPTIONS 45 PURGE METER TUBING - -
46 AIR SET - -
47 DAMPING DEVICE YES YES
48 CABLE CONNECTION - -
49 IS BARRIER - -
50 CALIBRATION Required with Certificates Required with Certificates
51 MANUFACTURER
52 MODEL No.
53 NOTES:-
Refer Notes section.
DATA SHEET FOR DIFFERENTIAL PRESSURE
TRANSMITTER
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code
DATA SHEET FOR DIFFERENTIAL PRESSURE
OIL-100-EK-I-DS-0820 A0 Sheet No.: 02 of 05
TRANSMITTER

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DATA SHEET FOR DIFFERENTIAL PRESSURE TRANSMITTER
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code
DATA SHEET FOR DIFFERENTIAL PRESSURE
OIL-100-EK-I-DS-0820 A0 Sheet No: 03 of 06
TRANSMITTER

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT
EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR DIFFERENTIAL PRESSURE TRANSMITTER OIL-100-EK-I-DS-0820 A0 Sheet No: 04 of 05

Notes:

1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test , weather
proof certificate, Pressure test Procedure/Report , Operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. All transmitters shall be provided with integral indicator (LCD type) with engineering unit indicating total level in mm & %.
4. Instrumentation shall meet the Electromagnetic interference requirements according to EN 50081-2 and EN 50082-2.
5. All field transmitters shall be" SMART" type, 2-wire 24VDC loop powered communicating on 4-20mA signal HART

6. Flange finish shall be in accordance with ANSI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250 AARH and 63 AARH for Ring type joint (RTJ
7. The housing of all transmitters shall be SS 316 minimum and suitable for hazardous area.
8. Certified plug shall be provided for spare cable entry.
9. Transmitters in safety loops shall be provided with SIL-2 (min) certification.
10. The over-range/static pressure protection of the transmitter shall be 130% of range.
11. Painting shall be Manufacturer standard suitablefor hazardous area.
12. The design of electronic instruments shall be in compliance with the electromagnetic compatibility requirements as per IEC-61000-4.

Hold:
1. Design condition to be confirmed

REFERENCE DOCUMENTS:
17039-EK-I-DB-8001_Functional specification for package instruments_Rev C
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR DIFFERENTIAL PRESSURE TRANSMITTER SEE BELOW TABLE OIL-100-EK-I-DS-0820
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 05 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 29-Nov-18 PGN 29-Nov-18 MV 29-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
VS 29-Nov-18

UNITS: Pressure: kg/cm2 g Temp: ° C

GENERAL

1. MOUNTING REMOTE (2" PIPE MOUNTED) 8. ZERO SUPPRESSION REQUIRED


2. ACCURACY ± 0.25% OF SPAN 9. ZERO ELEVATION REQUIRED
3. OVER PRESSURE LIMIT * 10. ZERO ADJUST LOCATION EXTERNAL
4. AMBIENT TEMP. LIMIT 11 TO 34°C 11. SPAN ADJUST LOCATION EXTERNAL
5. OUTPUT 4-20 MADC, HART PROTOCOL WITH SMART TR. 12. ENCLOSURE RATING IP 65
6. POWER SUPPLY 24 VDC LOOP POWERED 13. AREA CLASSIFICATION ZONE 2, GAS GROUP IIA/IIB, T3
7. INDICATING YES, LCD IN ENGINEERING UNIT 14. EQUIPMENT CERTIFICATION EX 'IA'

CONSTRUCTION
1. SERVICE PRESSURE 11. HOUSING MATERIAL SS 316
2. PROCESS CONNECTION 1/2" NPT 12. XMTR DIAPHRAGM. MATERIAL N/A
3. ELECTRICAL CONNECTION 1/2" NPT(F) 13. O-RING MATERIAL GLASS-FILLED PTFE
4. MOUNTING BRACKET YES, FOR 2" PIPE 14. SENSOR FILL FLUID SILICONE OIL
5. PROCESS SEAL TYPE N/A 15. DIAPHRAGM SEAL MATERIAL N/A
6. HYDROTEST REQ'D NO 16. CAPILLARY MATERIAL N/A
7. DIAPHRAGM SEAL NO 17. DRAIN/VENT MATERIAL SS 316
8. CAPILLARY LENGTH N/A 18. FLANGE BOLT MATERIAL N/A
9. CAPILLARY FILL FLUID N/A 19. BRACKET BOLT MATERIAL SS 316
YES (1/4" DRAIN CONNECTION PIPE
10. DRAIN / VENT PLUG 20. SIL COMPLIANCE SIL-2
SUPPLIED WITH MANIFOLD) 21. MANUFACTURER *

NOTES
1) EACH INSTRUMENT SHALL INCLUDE A SS 316 TAG PERMANENTLY ATTACHED TO THE INSTRUMENT USING SS 316 SCREWS, SS 316 BOLTS OR SS 316 WIRE.
2) TRANSMITTER UN-USED CONDUIT ENTRY SHALL BE PLUGGED WITH CERTIFIED EX'D' PLUG.
3) PAINTING SHALL BE MANUFACTURER STANDARD SUITABLE FOR HAZARDOUS ENVIRONMENT.
4) DIFFERNTIAL PRESSURE TRANSMITTER SHALL BE PROVIDED WITH 5 VALVE MANIFOLD.
5) FOR GENERAL NOTES REFER NOTES SECTION.

INSTRUMENT OPERATING DESIGN OPERATIN DESIGN


CALIBRATED RANGE DENSITY SPECIFIC MODEL
S.NO. TAG NUMBER LOCATION / SERVICE P&ID NUMBER RANGE PRESSURE PRESSURE G TEMP. TEMP. REMARKS
IN KG/CM2 (KG/M3) GRAVITY NUMBER
IN KG/CM2 (KG/CM2) (KG/CM2) (°C) (°C)

ACROSS BASKET TYPE STRAINER


1 20-PDT-2000 (3"-PL-20-2402-AC01) / CRUDE 17039-EK-P-DW-0219-01 * 0-1 10 15 (HOLD) 55 90 (HOLD) 870 0.87 * -
OIL
ACROSS BASKET TYPE STRAINER
2 20-PDT-2001 (3"-PL-20-2403-AC01) / CRUDE 17039-EK-P-DW-0219-01 * 0-1 10 15 (HOLD) 55 90 (HOLD) 870 0.87 * -
OIL
ACROSS BASKET TYPE STRAINER
3 20-PDT-2002 (3"-PL-20-2404-AC01) / CRUDE 17039-EK-P-DW-0219-01 * 0-1 10 15 (HOLD) 55 90 (HOLD) 870 0.87 * -
OIL
ACROSS BASKET TYPE STRAINER
4 20-PDT-2003 (3"-PL-20-2405-AC01) / CRUDE 17039-EK-P-DW-0219-01 * 0-1 10 15 (HOLD) 55 90 (HOLD) 870 0.87 * -
OIL

* To be Provided By Vendor.
DATA SHEET FOR PRESSURE TRANSMITTER
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR PRESSURE TRANSMITTER OIL-100-EK-I-DS-0821 A0 Sheet No.: 02 of 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS - PT
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR PRESSURE TRANSMITTER OIL-100-EK-I-DS-0821 A0 Sheet No: 03 of 06

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) Revision Index
AT EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR PRESSURE TRANSMITTER OIL-100-EK-I-DS-0821 A0 Sheet No: 04 of 05

Notes:
1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test , Explosion proof & weather
proof certificate, Pressure test Procedure/Report , SIL 2 Certificate, Operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. All transmitters shall be provided with integral indicator (LCD type) with engineering unit indication.
4. Instrumentation shall meet the Electromagnetic interference requirements according to EN 50081-2 and EN 50082-2.
5. All field transmitters shall be" SMART" type, 2-wire 24VDC loop powered communicating on 4-20mA signal mode with superimposed HART
6. The housing of all transmitters shall be SS 316 minimum and suitable for aggressive offshore environment.
7. Transmitter shall be provided with two(2) cable entry of size 1/2" NPT(F). Unused cable entries shall be plugged with ex-proof 316L SS certified plugs.
8. All Transmitters shall be provided with SIL-2 (min) certification.
9. The over-range/static pressure protection of the transmitter shall be 130% of range.
10. Calibration and test certificate to be provided for each instrument.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR PRESSURE TRANSMITTER SEE BELOW TABLE OIL-100-EK-I-DS-0821
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 05 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 29-Nov-18 MV 29-Nov-18 MSR/ VSR 29-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
IMR 04-Oct-18

UNITS: Pressure: kg/cm2 g Temp: °C Flow: Gas: MMSCFD Liquid: m3/hr

GENERAL
1. Mounting Direct/Manifold 9. Zero Suppression N/A
2. Accuracy ± 0.25% of Span or better 10. Zero Elevation N/A
3. Over Pressure Limit * 11. Zero Adjust Location External
4. Ambient Temp. Limit 8 to 38°C 12. Span Adjust Location External
5. Output 4-20 mA DC, 2-wire, HART Protocol with SMART Tr. 13. Enclosure Rating IP 65
6. Power Supply 24 VDC Loop powered 14. Area Classification Zone 2, Gas Group IIA&IIB, Temp. Cl. T3
7. Indicating Yes, LCD in engineering unit 15. Equipment Certification Ex'd'
8. Power consumption * 16. Load Limitation *

CONSTRUCTION
1. Service Gauge Pressure Transmitter 11. Housing Material Polyurethane Coated Aluminum
2. Process connetion 1/2" NPT(F) 12. Xmtr Diaphragm. Material SS 316
3. Electrical Connection 1/2" NPT(F) 13. O-Ring Material Glass-Filled PTFE
4. Mounting Bracket Not required 14. Fill Fluid Material N/A
5. Process Seal Type No 15. Diaphragm Seal Material N/A
6. Hydrotest Req'd Yes 16. Capillary Material N/A
7. Diaphragm Seal No 17. Drain/Vent Material SS 316
8. Capillary Length N/A 18. Flange Bolt Material N/A
9. Capillary Fill Fluid N/A 19. Bracket Bolt Material SS 316
10. Drain / Vent Yes (1/4" Drain connection pipe plug 20. Manufacturer *
supplied with Manifold) 21. Manifold Model No. *

NOTES
1) Each instrument shall include a SS tag permanently attached to the instrument using SS screws, SS bolts or ss wire.
2) Painting shall be Manufacturer standard suitable for Hazardous environment.
3) All pressure transmitters shall be provided with 2 valve Manifold and it is to be fitted, tested & supplied along with the Instrument.
4) For General notes refer Notes section.

Calibrated Design Flange


Operating Pressure Design Pressure Model SIL
S.No. Tag Number Service Description P&ID Number Range Temp. Size/ Remarks
(Kg/cm2)g (Kg/cm2)g Number Rating
kg/cm2 g (°C) Rating

Effluent Water Transfer


1 66-PT-6602 17039-EK-P-DW-0206-01 0 - 10 5 10 85 * 2
pump outlet

* To be Provided By Vendor.
DATA SHEET FOR PRESSURE GAUGE
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR PRESSURE GAUGE OIL-100-EK-I-DS-0822 A0 Sheet No.: 02 of 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS - PG
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR PRESSURE GAUGE OIL-100-EK-I-DS-0822 A0 Sheet No: 03 of 06

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) Revision Index
AT EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR PRESSURE GAUGE OIL-100-EK-I-DS-0822 A0 Sheet No: 04 of 05

Notes:
1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test , Explosion proof & weather
proof certificate, Pressure test Procedure/Report , SIL 2 Certificate, Operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. Bourdon tube gauges shall be tested in accordance with of BS EN 837-1.
4. The gauge shall be weather proof to IP 65 as per IEC 60529 / IS 13947, as minimum.
5. Dial markings and dial colour shall be as per IS 3624.
6. The pressure gauge shall have an over-range protection of at least 130% of maximum working pressure, as minimum.
7. Calibration and test certificate to be provided for each instrument.
8. Painting shall be Manufacturer standard suitable for Hazardous environment.
9. All pressure transmitters shall be provided with 2 valve Manifold and it is to be fitted, tested & supplied along with the Instrument.
10. Valve manifold shall have 1/2" NPT(F) connection on process, gauge and 1/4'' NPT(F) Connection on vent/ drain & Material shall be same as the element material.
11. Gauge construction shall ensure no leakage of process fluid to atmosphere.
12. Vendor to select the filling liquid which shall be compatible with the maximum process temperature.
13. Liquid filled damping shall be provided, suitable fluid to be selected according to the process fluid conditions.
14. Gauge shall be provided with Snubber whereever the service specified is pulsating type (i.e, Pump discharge etc.,) and the MOC shall be same as socket material.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR PRESSURE GAUGE SEE BELOW TABLE OIL-100-EK-I-DS-0822
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 05 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 29-Nov-18 MV 29-Nov-18 MSR/ VSR 29-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
IMR 04-Oct-18
UNITS: Pressure: kg/cm2 g Temp: °C Flow: Gas: MMSCFD Liquid: m3/hr

GENERAL
1. Type Local 16. Socket Material SS 316
2. Style Solid Front 17. Liquid Filled Yes
3. Mounting Direct 18. Fill Fluid Glycerin
4. Dial Size 150 mm (Note-6) 19. Process Connection 1/2" NPT(M)
5. Range Units Kg/cm2g 20. Connnection Location Bottom
6. Accuracy ± 1% of range 21. Enclosure Rating IP 65 (Min)
7. Repeatability Included in Accuracy 22. Press. GaugeManufacturer *
8. Hysteresis Included in Accuracy 23. Press. Gauge Model No. Refer Below
9. Ring Type Cam ring (Bayonet type) 24 Manifold Manufacturer *
10. Blowdown Protection Back 25. Manifold Model No. *
11. Element Type Bourdon Tube 26.
12. Diaphragm Seal Not Required 27.
13. Case Material SS 316 28.
14. Lens Material Lamited Safety Glass 29.
15. Element Material SS 316 30.

NOTES
1) For General notes refer Notes sheet.

Calibrated Design Flange


Operating Pressure Design Pressure Model Notes &
S.No. Tag Number Service Description P&ID Number Range Temp. Size/ Remarks
(Kg/cm2) (Kg/cm2) Number Options
Kg/ Cm2 g (°C) Rating

Effluent Water Storage


1 66-PI-6601 17039-EK-P-DW-0206-01 0 - 16 5 10 85 *
Tank (EK-ABJ-3450) outlet

Fire water Storage Tanks


2 71-PI-7266 17039-EK-P-DW-0217-01 0 - 2 (Hold) Atm.+Liquid Head FOW+0.07 80 *
(EK-ABJ-3110A/B) Inlet

* To be Provided By Vendor.
DATA SHEET FOR TEMPERATURE GAUGE WITH
THERMOWELL
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code
DATA SHEET FOR TEMPERATURE GAUGE WITH
OIL-100-EK-I-DS-0823 A0 Sheet No.: 02 of 05
THERMOWELL

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS - TG
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code
DATA SHEET FOR TEMPERATURE GAUGE WITH
OIL-100-EK-I-DS-0823 A0 Sheet No: 03 of 05
THERMOWELL

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) Revision Index
AT EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR TEMPERATURE GAUGE WITH THERMOWELL OIL-100-EK-I-DS-0823 A0 Sheet No: 04 of 05

Notes:
1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test , Explosion proof & weather
proof certificate, Pressure test Procedure/Report , SIL 2 Certificate, Operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. Vendor shall perform wake frequency calculations (WFC) for all thermowells according to ASME PTC 19.3 and report to be submitted.
4. Flange finish shall be in accordance with ANSI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250 AARH and 63 AARH for Ring type joint (RTJ) .
5. Temperature gauges shall be of the separate socket type suitable for well installation.
6. The gauge shall be weatherproof to IP65 as per IEC 60529/ IS 13947 as a minimum.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR TEMPERATURE GAUGE WITH THERMOWELL SEE BELOW TABLE OIL-100-EK-I-DS-0823
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 05 A0
CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 29-Nov-18 MV 29-Nov-18 MSR/ VSR 29-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
IMR 14-Sep-18

UNITS: Pressure: kg/cm2 g Temp: °C Flow: Gas: MMSCFD Liquid: m3/hr

THERMOMETER
1. Type Bi-Metal 12. Stem Material SS 316
2. Stem Diameter To suit Thermowell dia. 13. Case Material SS 316
3. Dial Size/ Color 150mm/ White with Black Markings 14. Lens Material Shatter-Proof Glass
4. Range Units °C 15. Hermetically Sealed Yes
5. Stem Type Threaded & Union 16. Liquid Filled No
6. Stem/ Union Size 1/2" NPT 17. Capillary Connection N/A
7. External Adjustment Yes 18. Capillary Material N/A
8. Orientation Adjutable, Everyangle 19. Manufacturer *
9. Weather Protection IP 66 (Note-6)
10. Accuracy ± 1% of Span
11. Over range Protection Required, 130% of Max. range

THERMOWELL
1. Included Yes 7. Bore Diameter 0.26"
2. Material 316 stainless steel 8. Element Connection 1/2" NPT
3. Construction Solid drilled bar-stock 9. Process Connection See below

NOTES
1) Each instrument shall include a SS tag permanently attached to the instrument using SS screws, SS bolts or ss wire.
2) Thermometer & Thermowell assembled together as one unit.
3) Vendor will be responsible for chosing model numbers.
4) Thermowell Tag to be same as Temperature Gauge Tag.
5) "U" Length includes Nozzle projection length.
6) It is Vendor's responsibility to ensure sensor length matches the specified U Dimensions.

Temp. Nozzle
Calibrated Design T/W Flange
(Normal/ Line Velocity Projetion Model
S.No. Tag Number Service Description P&ID Number Range Pressure "U"/ Lag. Size & Remarks
Design) Insulation (m/s) Length Number
Deg.C Kg/cm2g mm Rating
Deg.C (mm)
20-TI-1388/ Crude Oil Test Tank (27-50)/ 2"/
1 17039-EK-P-DW-0202-13 0 - 100 FOW+0.07 NA 500 0.1 150 *
20-TW-1388 (EK-BBJ-1111) 90 150# RF
20-TI-0989/ Treated Crude Storage Tank 2"/
2 17039-EK-P-DW-0203-10 0 - 100 55/ 90 FOW+0.07 NA 500 0.1 150 *
20-TW-0989 (EK-BBJ-1120A) 150# RF
20-TI-0997/ Treated Crude Storage Tank 2"/
3 17039-EK-P-DW-0203-11 0 - 100 55/ 90 FOW+0.07 NA 500 0.1 150 *
20-TW-0997 (EK-BBJ-1120B) 150# RF
44-TI-8043A/ PW Fr. Crude Dehydrator (EK- 2"/
4 17039-EK-P-DW-0203-21 0 - 100 55/ 90 FOW+0.07 NA 500 0.1 150 *
44-TW-8043A MBM-A-1120A) 150# RF
44-TI-8043B/ PW Fr. Crude Dehydrator (EK- 2"/
5 17039-EK-P-DW-0203-21 0 - 100 55/ 90 FOW+0.07 NA 500 0.1 150 *
44-TW-8043B MBM-A-1120B) 150# RF
20-TI-0430/ Offspec Crude Storage Tank 2"/
6 17039-EK-P-DW-0203-14 0 - 100 55/ 90 FOW+0.07 NA 500 0.1 150 *
20-TW-0430 (EK-BBJ-1120B) 150# RF
66-TI-3521/ Effluent Water Storage Tank 2"/
7 17039-EK-P-DW-0206-01 0 - 100 51/ 85 FOW+0.07 NA 500 0.1 150 *
66-TI-3521 (EK-ABJ-3454 A/B) 150# RF
66-TG-6636A/ Clarified Water Storage Tank 2"/
8 17039-EK-P-DW-0206-02 0 - 100 51/ 85 FOW+0.07 NA 500 0.1 150 *
66-TG-6636A (EK-ABJ-3451A) 150# RF
66-TG-6636B/ Clarified Water Storage Tank 2"/
9 17039-EK-P-DW-0206-02 0 - 100 51/ 85 FOW+0.07 NA 500 0.1 150 *
66-TG-6636B (EK-ABJ-3451B) 150# RF
66-TI-6620/ Skim Oil Tank 2"/
10 17039-EK-P-DW-0206-04 0 - 100 55/ 90 FOW+0.07 NA 500 0.1 150 *
66-TI-6620 (EK-ABJ-3452) 150# RF
66-TG-6637/ Offspec Effluent Water 2"/
11 17039-EK-P-DW-0206-06 0 - 100 51/ 85 FOW+0.07 NA 500 0.1 150 *
66-TG-6637 Storage Tank (EK-ABJ-3453) 150# RF
* To be Provided By Vendor.
DATA SHEET FOR ELECTROMAGNETIC FLOW METER
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KAHGORIJAN Datasheet Number
Code

DATA SHEET FOR ELECTROMAGNETIC FLOW METER OIL-100-EK-I-DS-0824 A0 Sheet No.: 02 of 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS - FT (Mag.type)
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KAHGORIJAN Datasheet Number
Code

DATA SHEET FOR ELECTROMAGNETIC FLOW METER OIL-100-EK-I-DS-0824 A0 Sheet No: 03 of 05

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (GGS)
Revision Index
AT EAST KAHGORIJAN Datasheet Number Rev Code

DATA SHEET FOR ELECTROMAGNETIC FLOW METER OIL-100-EK-I-DS-0824 A0 Sheet No: 04 of 05

Notes:
1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test , Explosion proof & weather
proof certificate, Pressure test Procedure/Report , Operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. All transmitters shall be provided with integral indicator (LCD type) with engineering unit indication.
4. Instrumentation shall meet the Electromagnetic interference requirements according to EN 50081-2 and EN 50082-2.
5. All the electrical cables on the transmitters and sensors terminate to terminal blocks,flying leads are not allowed.
6. All fastners including stud-bolts and nuts material shall be A193Gr.B7M / A194Gr.2HM with Zinc coated (hot dipped) according to ASTM A153.
6. Flange finish shall be in accordance with ANSI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250 AARH.
7. The housing of all transmitters shall be SS 316 minimum.
8. Transmitter shall be provided with two(2) cable entry of size 1/2" NPT(F). Unused cable entries shall be plugged with ex-proof SS certified plugs.
9. The over-range/static pressure protection of the transmitter shall be 130% of range.
10. Calibration and test certificate to be provided for each instrument.
11. The flow direction shall be clearly stamped or cast on the body to avoid polarity errors.
12. Meter shall have forward & reverse measurement functions and reverse flow shall be confirmed by status output / indication.
13. The Electro-Magnetic Meter’s field coils shall be hermetically sealed. Coil insulation shall be class F suitable for high temperature. Suitable grounding type system
and material shall be selected for the meter.
14. Vendor shall indicate the power supply requirements and furnish the power consumption for the meter (sensor, transmitter, display, etc.) along with
the sizing calculations for the selected meter.
15. Standard Signal types and communication protocols shall be offered. Appropriate EMI / RFI protection for the meter shall be considered.
16. Bolted coil housing with rubber or plastic gaskets is not acceptable.
17. Tube liners shall be selected to meet the process requirement and shall be proven for the application.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR ELECTROMAGNETIC FLOW METER AS BELOW OIL-100-EK-I-DS-0824
PROJECT DESCRIPTION PROJECT No. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KAHGORIJAN KIP-17039 05 OF 05 A0
MPC CONTRACTOR SUPPLIET DOC.No. PURCHASE ORDER No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 29-11-18 MV 29-11-18 MSR/ VSR 29-11-18 ISSUED FOR REVIEW
CLIENT DOC.No.:
-
ORIGINATOR ORIG. DATE
IMR 5 October 2018
UNITS:- Pressure bar g kg/cm2 g kPa g psig Flow : Gas MMSCFD MMSCMD Sm3/hr kg/hr
0 0 3
Temp C F Liquid m /hr kg/hr USgpm bpd
1 TAG NO. 66-FT-6635
Off-Spec Effluent water Transfer Pumps
2 SERVICE (EK-PBA-3456 A/B) Discharge

GENERAL 3 LINE No. 4"-WE-66-6659-AC01

4 P & ID No. 17039-EK-P-DW-0206-06

5 LINE SIZE / SCH 4"/ Sch. STD

6 LINE MATERIAL ASTM A 106 Gr.B

7 FLUID OFF-SPEC EFFLUENT WATER


8 MAX. VELOCITY ( m/sec) 1
9 FLOW.: MIN. NORM. MAX. 1108 KPD
10 TEMP.: MIN. NORM. MAX. 51
FLUID DATA 11 PRESS.: MIN. NORM. MAX.
-1
12 MIN.FLUID CONDUCTIVITY (S m )
13 VACCUM POSSIBILITY
14 DESIGN: PRESS. TEMP 10 85
3
15 DENSITY/SPEC.GRAV (kg/m ) 1000
16 VISCOSITY (cP) 0.54
17 PRESSURE DROP MINIMUM

18 METER RANGE TBA


19 METER SIZE 4" *

20 TUBE MATERIAL SS 316

21 LINER MATERIAL PTFE


STD, 2 No's MEASUREMENT ELECTRODE
22 ELECTRODE TYPE (Note-12&13)

23 ELECTRODE MATERIAL SS 316

METER 24 METER CASING SS 316

25 POWER SUPPLY 24 VDC, External

26 GROUNDING,TYPE & MATERIAL 2-RING's & SS316

27 ENCLOSURE CLASS Ex'ia' / IP 65

28 CONNECTION TYPE FLANGED / 150# RF

29 MATERIAL ASTM CS, A-105

30 AREA CLASSIFICATION Zone 2, Gas Group IIA&IIB, Temp. Cl. T3

31 ACCURACY REPEATABILITY ± 0.5% OF FLOW ±0.1%


32 RANGEABILITY -
33 FUNCTION TRANSMISSION & INDICATION

34 MOUNTING INTEGRAL WITH METER

35 ENCLOSUER CLASS IEC Ex'ia' / IP 65

36 LENGTH SIGNAL CABLE -


TRANSMITTER 37 SPAN ADJUSTMENT -

38 POWER SUPPLY 24 VDC, External

39 TRANSMITTER OUTPUT 4-20 mA -ISOLATED OUTPUT (HART)

40 DISPLAY LOCAL LCD DISPLAY

41 INTEGRATOR -

42 ELECTRICAL CONNECTION ISO M20 X 1.5 (2 No's)

43 FORM - -
44 ALARM RATING -
45 ACTION -
46 MANUFACTURER *

OPTIONS 47 METER MODEL No. *

48 TRANSMITTER MODEL No. *

NOTES:- * TO BE SUPPLIED BY THE SCOPE OF VENDOR.

REFER NOTES SHEET


DATA SHEET FOR DP TYPE FLOW INDICATORS
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR DP TYPE FLOW INDICATORS OIL-100-EK-I-DS-0825 A0 Sheet No.: 02 of 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DATA SHEET FOR DP TYPE FLOW INDICATORS
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR DP TYPE FLOW INDICATORS OIL-100-EK-I-DS-0825 A0 Sheet No: 03 of 06

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST
KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR DP TYPE FLOW INDICATORS OIL-100-EK-I-DS-0825 A0 Sheet No: 04 of 05

NOTES:

1. DOCUMENTATION REQUIRED :- CALIBRATION CERTIFICATE, INGRESS PROTECTION CERTIFICATE, MATERIAL CERTIFICATES TO 3.1 AS PER EN 10204,
HYDRO TEST, WEATHER PROOF CERTIFICATE, PRESSURE TEST PROCEDURE/REPORT, OPERATING & MAINTENANCE INSTRUCTIONS & SPARE PARTS LIST.
2. ALL INSTRUMENTS TO BE SUPPLIED WITH A SS 316 NAME PLATE WITH TAG NO. PERMANENTLY INSCRIBED. TAGS SHALL BE PERMANENTLY SECURED.
3. DP TYPE FLOW INDICATOR SHALL BE PROVIDED WITH A VISIBLE POINTER STOP TO RESTRICT THE UPPER LIMIT OF THE POINTER TRAVEL.
4. THE GAUGE SHALL BE WEATHER PROOF TO IP 65 AS PER IEC 60529 / IS 13947, AS MINIMUM.
5. DIAL MARKINGS AND DIAL COLOUR SHALL BE AS PER IS 3624.
6. THE DIAL COVER SHALL BE MADE OUT OF SHATTER PROOF GLASS SHEET OF THICKNESS WITH MINIMUM 3.0 MM.
7. VALVE MANIFOLD SHALL HAVE 1/2" NPT(F) CONNECTION ON PROCESS, GAUGE AND 1/4'' NPT(F) CONNECTION ON VENT/ DRAIN & MATERIAL SHALL BE SAME AS
THE ELEMENT MATERIAL.
8. GAUGE CONSTRUCTION SHALL ENSURE NO LEAKAGE OF PROCESS FLUID TO ATMOSPHERE.
9. VENDOR TO SELECT THE FILLING LIQUID WHICH SHALL BE COMPATIBLE WITH THE MAXIMUM PROCESS TEMPERATURE.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR DP TYPE FLOW INDICATORS SEE BELOW TABLE OIL-100-EK-I-DS-0825
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 05 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 29-Nov-18 PGN 29-Nov-18 MV 29-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
VS 29-Nov-18

UNITS: PRESSURE: kg/cm2 g TEMP : ° C

GENERAL
1. TYPE DIRECT READING 16. PRESS. ELEMENT DIAPHRAGM
2. MOUNTING SURFACE 17. MOVEMENT MATL. SS316
3. DIAL SIZE DIAMETER: 150mm 18. ELEMENT MATL. SS316
4. COLOUR WHITE WITH BLACK LETTERS 19. SOCKET MATL. SS316
5. CASE SS316 20. CONNECTION: 1/2" NPTM
6. RING SCREWED TYPE 21. OVER RANGE PROTECTION 130% OF MAX PRESS RANGE
7. SAFETY BLOW-OUT BACK 22. ACCURACY ±1% OF FSD
8. PROTECTION SOLID FRONT 23. MANIFOLD MANUFACTURER *
9. LENS SHATTER PROOF GLASS 24 MANIFOLD MODEL NO *
10. MANIFOLD TYPE 5 - VALVE MANIFOLD MATERIAL SS 316 25.
11. MOUNTING BRACKET YOKE MOUNTING BRACKET, SS 316 FOR 2"NB PIPE STAND 26.
12. LQUID FILLED YES 27.
13. FILL FLUID SILICONE FILLED 28.
14. WEATHER PROTECTION IP 65 29.
15. MANUFACTURER * 30.

NOTES
1) For General notes refer Notes sheet.

Instrument
Calibrated Design
Range Flow Range Operating Pressure Operating Design Temp.
S.No. Tag Number Line Number / Service P&ID Number Range Pressure Remarks
kg/cm2 m3/hr (Kg/cm2) Temp. (°C) (°C)
mbar (Kg/cm2)

8"-WF-71-7108-AG01 /FIRE
WATER FROM FIRE WATER
1 71-FI-7266 17039-EK-P-DW-0217-01 * 0-450 0 - 250 ATM FOW 41 80 -
DISCHARGE PUMP TO FIRE
WATER STORAGE TANK

* To be Provided By Vendor.
DATA SHEET FOR RADAR TYPE LEVEL
TRANSMITTER
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES
Rev
(GGS) AT EAST KHAGORIJAN Datasheet Number Code

DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER OIL-100-EK-I-DS-0826 A0 SHEET 02 OF 10

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER
6 DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER
7 DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER
8 DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES
Rev
(GGS) AT EAST KHAGORIJAN Datasheet Number Code

DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER OIL-100-EK-I-DS-0826 A0 SHEET 03 OF 10

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES
Rev
(GGS) AT EAST KHAGORIJAN Datasheet Number Code
DATA SHEET FOR RADAR TYPE LEVEL
OIL-100-EK-I-DS-0826 A0
TRANSMITTER Sheet No.: 04 of 10
Notes Sheet

1. Documentation required :- Calibration certificate, Hydro test report, Material certificates to 3.1 as per EN10204, weather proof to

IP65 certificate by ATEX or Equivalent body, Pressure test procedure/Report, NDT procedure / Report, GAD Wiring diagram, Operating and

Maintenance Instructions & Spare Parts List.

2. Radar type level transmitter shall be provided with 1 mm thick, 30mm x 75mm SS 316 tag plate, inscribed with tag number engraved or

embossed in 5mm high and 0.3mm deep bold characters and black paint filled. The tags shall be mounted on or adjacent to the associated

instrument and either fixed with stainless steel screws or attached with stainless steel wire.

3. All stud bolt material shall be ASTM A 193 Gr. B7 / ASME B16.5 (Hot dip galvanized).

4. Transmitter shall be provided with dual cable entries. Unused cable entries shall be provided with explosion proof plugs of SS 316.

5. All weldings and castings (if any) shall be 100% radiographed.

6. Transmitters shall employ intelligent digital signal processingtechniques to filter out false echo signals.

7. Flange finish shall be in accordance with ANSI B16.5, For raised face (RF) flanges and shall be smooth finish to 125-250AARH

8. Instruments shall meet electromagnetic compatibility requirements according to IEC 61000.

9. All instrumentation must be certified by a recognised european certification authority such as ATEX/FM/UL/BASEEFA/CMRI/PTB

Hold 1:

1. Pressure data shall be updated later.

REFERENCE DOCUMENTS:

17039-EK-I-DB-8001_Functional specification for package instruments_Rev C


TITLE ITEM/TAG No. DATA SHEET No.

DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER REFER BELOW OIL-100-EK-I-DS-0826
PROJECT DESCRIPTION PROJECT NO. SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 10 A0


EPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 30-Nov-18 PG 30-Nov-18 MV 30-Nov-18 Issued For Review
Client Document No.
-
ORIGINATOR ORIG. DATE
VS 30-Nov-18
UNITS:- Pressure bar g kg/cm2 g kPa g psig LEVEL : mm
0 0
Temp C F
1 20-LIT-1382 20-ILT-1383 20-LT-0986A
TAG NO.
2 CRUDE OIL TEST TANK CRUDE OIL TEST TANK TREATED CRUDE STORAGE TANK
SERVICE
3 17039-EK-P-DW-0202-13 17039-EK-P-DW-0202-13 17039-EK-P-DW-0203-10
P&ID NO.
GENERAL

4 6000 (I/D) X 8000 (H) 6000 (I/D) X 8000 (H) 9600 (I/D) X 14000 (H)
VESSEL SIZE
SHELL / BOTTOM :CARBON STEEL + 3mm SHELL / BOTTOM :CARBON STEEL + SHELL / BOTTOM :CARBON STEEL +
5 CA, 3mm CA, 3mm CA,
VESSEL MATERIAL ROOF (CS + 1.5mm) ROOF (CS + 1.5mm) ROOF (CS + 1.5mm)

6 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3
AREA CLASSIFICATION
7 EK-BBJ-1111 EK-BBJ-1111 EK-BBJ-1120A
TANK NO
8 UPPER FLUID / PHASE CRUDE OIL / LIQUID CRUDE OIL / LIQUID CRUDE OIL / LIQUID

9 LOWER FLUID / PHASE

10 INTERFACE
SERVICE CONDITIONS

11 SUSPENDED SOLIDS

12 ATM ATM ATM


PRESSURE (MAX. / NORM. / MIN. )
13 AMB AMB AMB
TEMPERATURE (MAX. / NORM. / MIN.)
14 FOL+0.07 / 90 FOL+0.07 / 90 FOL+0.07 / 90
DESIGN (PRESSURE / TEMPERATURE)
15 SPECIFIC GRAVITY

16 DENSITY UPPER LOWER Kg/m3 937.2 - 940.7 937.2 - 940.7 899.8

17 FLUID VISCOSITY UPPER LOWER cP 15.714 - 22.05 15.714 - 22.05 3.85

18 DIELECTRIC CONSTANT UPPER/LOWER 1.4 1.4 1.4

THERMAL CONDUCTIVITY LIQUID


19 W/m-K 0.248 - 0.643 0.248 - 0.643 0.12
(UPPER / LOWER)

20 INTERNAL / EXTERNAL

21 CAGE MATERIAL

22 OVER ALL C-C C-C1 C-C2

23 CONNECTION SIZE AND RATING

24 CAGE ORIENTATION / ROTATABLE HEAD


CAGE

25 CAGE TO HEAD FLANGE SIZE & RATING

26 CAGE TO HEAD GASKET / BOLTING

27 DRAIN / VENT CONN. SIZE & RATING

28 COOLING EXTENSION

29 ELECTRICAL HEAT TRACING

30 STAND PIPE

31 TYPE / MODEL Encapsulated Horn / * Encapsulated Horn / * Encapsulated Horn / *


ANTENNA

32 * * *
PROCESS CONNECTION
33 MOC SS 316 SS 316 SS 316
34 * * *
ANTENNA LENGTH DIAMETER * * *
35 VERTICAL VESSEL TOP VERTICAL VESSEL TOP VERTICAL VESSEL TOP
MOUNTING POSITION / MOUNTING LOCATION
Non Contact Type / Non Contact Type / Non Contact Type /
40 TYPE / PRINCIPLE
Pulse-burst radar technology Pulse-burst radar technology Pulse-burst radar technology

41 MOUNTING Direct on vessel Direct on vessel Direct on vessel

42 ACCURACY / INTER FACE ACCURACY ± 0.03% of measured distance / * ± 0.03% of measured distance / * ± 0.03% of measured distance / *

43 REPEATABILITY ± 1mm ± 1mm ± 1mm

44 PROTECTION CLASS/ENCLOSURE IP 65/ Ex'ia' IP 65/ Ex'ia' IP 65/ Ex'ia'


TRANSMITTER

45 POWER SUPPLY 24VDC loop powered with HART 24VDC loop powered with HART 24VDC loop powered with HART

46 OUTPUT 4 - 20 mA 4 - 20 mA 4 - 20 mA

47 PROCESS CONNECTION AND RATING(MOC) 8", 150# RF, SS 316 8", 150# RF, SS 316 8", 150# RF, SS 316

48 CALIBRATION RANGE MIN. / MAX. (%) 0-100% 0-100% 0-100%

49 INSTRUMENT RANGE MIN. / MAX. mm(%) 0-8000mm (0-100)% 0-8000mm (0-100)% 0-14000 mm (0-100)%

50 CABLE ENTRY | CABLE GLAND WITH PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG

51 LOCAL INDICATION / DISPLAY ENGG. UNIT LCD mm (%) LCD mm (%) LCD mm (%)

52 SIL CERTIFICATION SIL-2 SIL-2 SIL-2

53 MEASURING RANGE (FROM TANK BOTTOM) YES YES YES

54 MODEL NO. FOR SENSOR * * *


OTHERS

55 MODEL NO. FOR TRANSMITTTER * * *

56 MANUFACTURER * * *

57 NOTES:- REFER NOTES SHEET. * To be Furnished by Vendor.


TITLE ITEM/TAG No. DATA SHEET No.

DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER REFER BELOW OIL-100-EK-I-DS-0826
PROJECT DESCRIPTION PROJECT NO. SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 6 OF 10 A0


EPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 30-Nov-18 PG 30-Nov-18 MV 30-Nov-18 Issued For Review
Client Document No.
-
ORIGINATOR ORIG. DATE
VS 30-Nov-18
UNITS:- Pressure bar g kg/cm2 g kPa g psig level: mm
0 0
Temp C F
1 20-LT-0988A 20-LT-0986B 20-LT-0988B
TAG NO.
2 TREATED CRUDE STORAGE TANK TREATED CRUDE STORAGE TANK TREATED CRUDE STORAGE TANK
SERVICE
GENERAL

3 17039-EK-P-DW-0203-10 17039-EK-P-DW-0203-11 17039-EK-P-DW-0203-11


P&ID NO.
4 9600 (I/D) X 14000 (H) 9600 (I/D) X 14000 (H) 9600 (I/D) X 14000 (H)
VESSEL SIZE
5 CARBON STEEL + 3mm CA CARBON STEEL + 3mm CA CARBON STEEL + 3mm CA
VESSEL MATERIAL
6 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3
AREA CLASSIFICATION
7 EK-BBJ-1120A EK-BBJ-1120B EK-BBJ-1120B
TANK NO
8 UPPER FLUID / PHASE CRUDE OIL / LIQUID CRUDE OIL / LIQUID CRUDE OIL / LIQUID

9 LOWER FLUID / PHASE

10 INTERFACE
SERVICE CONDITIONS

11 SUSPENDED SOLIDS

12 ATM ATM ATM


PRESSURE (MAX. / NORM. / MIN. )
13 AMB AMB AMB
TEMPERATURE (MAX. / NORM. / MIN.)
14 FOL+0.07 / 90 FOL+0.07 / 90 FOL+0.07 / 90
DESIGN (PRESSURE / TEMPERATURE)
15 SPECIFIC GRAVITY

16 DENSITY UPPER LOWER Kg/m3 899.8 899.8 899.8

17 FLUID VISCOSITY UPPER LOWER cP 3.85 3.85 3.85

18 DIELECTRIC CONSTANT UPPER/LOWER 1.4 1.4 1.4

19 THERMAL CONDUCTIVITY LIQUID (UPPER / W/m-K 0.12 0.12 0.12


LOWER)
20 INTERNAL / EXTERNAL

21 CAGE MATERIAL

22 OVER ALL C-C C-C1 C-C2

23 CONNECTION SIZE AND RATING

24 CAGE ORIENTATION / ROTATABLE HEAD


CAGE

25 CAGE TO HEAD FLANGE SIZE & RATING

26 CAGE TO HEAD GASKET / BOLTING

27 DRAIN / VENT CONN. SIZE & RATING

28 COOLING EXTENSION

29 ELECTRICAL HEAT TRACING

30 STAND PIPE

31 TYPE / MODEL Encapsulated Horn / * Encapsulated Horn / * Encapsulated Horn / *


ANTENNA

32 * * *
PROCESS CONNECTION
33 MOC SS 316 SS 316 SS 316
34 * * *
ANTENNA LENGTH DIAMETER * * *
35 VERTICAL VESSEL TOP VERTICAL VESSEL TOP VERTICAL VESSEL TOP
MOUNTING POSITION / MOUNTING LOCATION
Non Contact Type / Non Contact Type / Non Contact Type /
40 TYPE / PRINCIPLE
Pulse-burst radar technology Pulse-burst radar technology Pulse-burst radar technology

41 MOUNTING Direct on vessel Direct on vessel Direct on vessel

42 ACCURACY / INTER FACE ACCURACY ± 0.03% of measured distance / * ± 0.03% of measured distance / * ± 0.03% of measured distance / *

43 REPEATABILITY ± 1mm ± 1mm ± 1mm

44 PROTECTION CLASS/ENCLOSURE IP 65/ Ex'ia' IP 65/ Ex'ia' IP 65/ Ex'ia'


TRANSMITTER

45 POWER SUPPLY 24VDC loop powered with HART 24VDC loop powered with HART 24VDC loop powered with HART

46 OUTPUT 4 - 20 mA 4 - 20 mA 4 - 20 mA

47 PROCESS CONNECTION AND RATING(MOC) 8", 150# RF, SS 316 8", 150# RF, SS 316 8", 150# RF, SS 316

48 CALIBRATION RANGE MIN. / MAX. (%) 0-100% 0-100% 0-100%

49 INSTRUMENT RANGE MIN. / MAX. mm(%) 0-14000 mm (0-100)% 0-14000 mm (0-100)% 0-14000 mm (0-100)%

50 CABLE ENTRY | CABLE GLAND WITH PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG

51 LOCAL INDICATION / DISPLAY ENGG. UNIT LCD mm (%) LCD mm (%) LCD mm (%)

52 SIL CERTIFICATION SIL-2 SIL-2 SIL-2

53 MEASURING RANGE (FROM TANK BOTTOM) YES YES YES

54 MODEL NO. FOR SENSOR * * *


OTHERS

55 MODEL NO. FOR TRANSMITTTER * * *

56 MANUFACTURER * * *

57 NOTES:- REFER NOTES SHEET. * To be Furnished by Vendor.


TITLE ITEM/TAG No. DATA SHEET No.

DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER REFER BELOW OIL-100-EK-I-DS-0826
PROJECT DESCRIPTION PROJECT NO. SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 7 OF 10 A0


EPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 30-Nov-18 PG 30-Nov-18 MV 30-Nov-18 Issued For Review
Client Document No.
-
ORIGINATOR ORIG. DATE
VS 30-Nov-18
UNITS:- Pressure bar g kg/cm2 g kPa g psig Level: mm
0 0
Temp C F
1 20-LT-0423 20-LT-0424 66-LIT-3510
TAG NO.
2 OFFSPEC CRUDE STORAGE TANK OFFSPEC CRUDE STORAGE TANK EFFLUENT WATER
SERVICE
GENERAL

3 P&ID NO. 17039-EK-P-DW-0203-14 17039-EK-P-DW-0203-14 17039-EK-P-DW-0206-01

4 8300 (I/D) X 12000 (H) 8300 (I/D) X 12000 (H) 20000 (I/D) X 18000(W) X 4000 (H)
VESSEL SIZE
5 CARBON STEEL + 3mm CA CARBON STEEL + 3mm CA CARBON STEEL + 3mm CA
VESSEL MATERIAL
6 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3
AREA CLASSIFICATION
7 EK-BBJ-1090 EK-BBJ-1090 EK-ABJ-3450
TANK NO
8 UPPER FLUID / PHASE OFF SPE CRUDE OIL / LIQUID OFF SPE CRUDE OIL / LIQUID EFFLUENT WATER / LIQUID

9 LOWER FLUID / PHASE OFF SPE CRUDE OIL / LIQUID OFF SPE CRUDE OIL / LIQUID EFFLUENT WATER / LIQUID

10 INTERFACE - - -
SERVICE CONDITIONS

11 SUSPENDED SOLIDS - - -

12 ATM ATM HOLD 1


PRESSURE (MAX. / NORM. / MIN. )
13 55 55 51
TEMPERATURE (MAX. / NORM. / MIN.)
14 FOL+0.07 / 90 FOL+0.07 / 90 HOLD 1 / 85
DESIGN (PRESSURE / TEMPERATURE)
15 SPECIFIC GRAVITY 0.87 0.87 0.87

16 DENSITY UPPER LOWER Kg/m3 870 870 870

17 FLUID VISCOSITY UPPER LOWER cP 1 1 1

18 DIELECTRIC CONSTANT UPPER/LOWER 1.4 1.4 1.4

19 THERMAL CONDUCTIVITY LIQUID (UPPER / W/m-K 120 120 120


LOWER)
20 INTERNAL / EXTERNAL

21 CAGE MATERIAL

22 OVER ALL C-C C-C1 C-C2

23 CONNECTION SIZE AND RATING

24 CAGE ORIENTATION / ROTATABLE HEAD


CAGE

25 CAGE TO HEAD FLANGE SIZE & RATING

26 CAGE TO HEAD GASKET / BOLTING

27 DRAIN / VENT CONN. SIZE & RATING

28 COOLING EXTENSION

29 ELECTRICAL HEAT TRACING

30 STAND PIPE

31 TYPE / MODEL Encapsulated Horn / * Encapsulated Horn / * Encapsulated Horn / *


ANTENNA

32 * * *
PROCESS CONNECTION
33 MOC SS 316 SS 316 SS 316
34 * * *
ANTENNA LENGTH DIAMETER * * *
35 VERTICAL VESSEL TOP VERTICAL VESSEL TOP VERTICAL VESSEL TOP
MOUNTING POSITION / MOUNTING LOCATION
Non Contact Type / Non Contact Type / Non Contact Type /
40 TYPE / PRINCIPLE
Pulse-burst radar technology Pulse-burst radar technology Pulse-burst radar technology
41 MOUNTING Direct on vessel Direct on vessel Direct on vessel

42 ACCURACY / INTER FACE ACCURACY ± 0.03% of measured distance / * ± 0.03% of measured distance / * ± 0.03% of measured distance / *

43 REPEATABILITY ± 1mm ± 1mm ± 1mm

44 PROTECTION CLASS/ENCLOSURE IP 65/ Ex'ia' IP 65/ Ex'ia' IP 65/ Ex'ia'


TRANSMITTER

45 POWER SUPPLY 24VDC loop powered with HART 24VDC loop powered with HART 24VDC loop powered with HART

46 OUTPUT 4 - 20 mA 4 - 20 mA 4 - 20 mA

47 PROCESS CONNECTION AND RATING(MOC) 8", 150# RF, SS 316 8", 150# RF, SS 316 8", 150# RF, SS 316

48 CALIBRATION RANGE MIN. / MAX. (%) 0-100% 0-100% 0-100%

49 INSTRUMENT RANGE MIN. / MAX. mm(%) 0-12000 mm (0-100)% 0-12000 mm (0-100)% 0-4000 mm (0-100)%

50 CABLE ENTRY | CABLE GLAND WITH PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG

51 LOCAL INDICATION / DISPLAY ENGG. UNIT LCD mm (%) LCD mm (%) LCD mm (%)

52 SIL CERTIFICATION SIL-2 SIL-2 SIL-2

53 MEASURING RANGE (FROM TANK BOTTOM) YES YES YES

54 MODEL NO. FOR SENSOR * * *


OTHERS

55 MODEL NO. FOR TRANSMITTTER * * *

56 MANUFACTURER * * *

57 NOTES:- REFER NOTES SHEET. * To be Furnished by Vendor.


TITLE ITEM/TAG No. DATA SHEET No.

DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER REFER BELOW OIL-100-EK-I-DS-0826
PROJECT DESCRIPTION PROJECT NO. SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 8 OF 10 A0


EPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 30-Nov-18 PG 30-Nov-18 MV 30-Nov-18 Issued For Review
Client Document No.
-
ORIGINATOR ORIG. DATE
VS 30-Nov-18
UNITS:- Pressure bar g kg/cm2 g kPa g psig level : mm
0 0
Temp C F
1 66-LT-6603A 66-LT-6603B 66-LT-6614
TAG NO.
2 CLARIFIED WATER CLARIFIED WATER (EK-ABJ--3451A) SKIM OIL
SERVICE
GENERAL

3 P&ID NO. 17039-EK-P-DW-0206-02 17039-EK-P-DW-0206-02 17039-EK-P-DW-0206-04

4 8500 (I/D) X 12000 (H) 8500 (I/D) X 12000 (H) 5800 (I/D) X 8000 (H)
VESSEL SIZE
5 CARBON STEEL + 3mm CA CARBON STEEL + 3mm CA CARBON STEEL + 3mm CA
VESSEL MATERIAL
6 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3
AREA CLASSIFICATION
7 EK-ABJ-3451A EK-ABJ-3451B EK-ABJ-3452
TANK NO
8 UPPER FLUID / PHASE CLARIFIED WATER / LIQUID CLARIFIED WATER / LIQUID SKIM OIL / LIQUID

9 LOWER FLUID / PHASE - - -

10 INTERFACE - - -
SERVICE CONDITIONS

11 SUSPENDED SOLIDS - - -

12 ATM ATM ATM


PRESSURE (MAX. / NORM. / MIN. )
13 51 51 55
TEMPERATURE (MAX. / NORM. / MIN.)
14 FOL+0.07 / 85 FOL+0.07 / 85 FOL+0.07 / 90
DESIGN (PRESSURE / TEMPERATURE)
15 SPECIFIC GRAVITY 1 1 0.8998

16 DENSITY UPPER LOWER Kg/m3 1000 1000 899.8

17 FLUID VISCOSITY UPPER LOWER cP 0.54 0.54 3.85

18 DIELECTRIC CONSTANT UPPER/LOWER 1 1 1.4

19 THERMAL CONDUCTIVITY LIQUID (UPPER / W/m-K - - -


LOWER)
20 INTERNAL / EXTERNAL

21 CAGE MATERIAL

22 OVER ALL C-C C-C1 C-C2

23 CONNECTION SIZE AND RATING

24 CAGE ORIENTATION / ROTATABLE HEAD


CAGE

25 CAGE TO HEAD FLANGE SIZE & RATING

26 CAGE TO HEAD GASKET / BOLTING

27 DRAIN / VENT CONN. SIZE & RATING

28 COOLING EXTENSION

29 ELECTRICAL HEAT TRACING

30 STAND PIPE

31 TYPE / MODEL Encapsulated Horn / * Encapsulated Horn / * Encapsulated Horn / *


ANTENNA

32 * * *
PROCESS CONNECTION
33 MOC SS 316 SS 316 SS 316
34 * * *
ANTENNA LENGTH DIAMETER * * *
35 VERTICAL VESSEL TOP VERTICAL VESSEL TOP VERTICAL VESSEL TOP
MOUNTING POSITION / MOUNTING LOCATION
Non Contact Type / Non Contact Type / Non Contact Type /
40 TYPE / PRINCIPLE
Pulse-burst radar technology Pulse-burst radar technology Pulse-burst radar technology
41 MOUNTING Direct on vessel Direct on vessel Direct on vessel

42 ACCURACY / INTER FACE ACCURACY ± 0.03% of measured distance / * ± 0.03% of measured distance / * ± 0.03% of measured distance / *

43 REPEATABILITY ± 1mm ± 1mm ± 1mm

44 PROTECTION CLASS/ENCLOSURE IP 65/ Ex'ia' IP 65/ Ex'ia' IP 65/ Ex'ia'


TRANSMITTER

45 POWER SUPPLY 24VDC loop powered with HART 24VDC loop powered with HART 24VDC loop powered with HART

46 OUTPUT 4 - 20 mA 4 - 20 mA 4 - 20 mA

47 PROCESS CONNECTION AND RATING(MOC) 8", 150# RF, SS 316 8", 150# RF, SS 316 8", 150# RF, SS 316

48 CALIBRATION RANGE MIN. / MAX. (%) 0-100% 0-100% 0-100%

49 INSTRUMENT RANGE MIN. / MAX. mm(%) 0-12000mm (0-100)% 0-12000mm (0-100)% 0-8000 mm (0-100)%

50 CABLE ENTRY | CABLE GLAND WITH PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG

51 LOCAL INDICATION / DISPLAY ENGG. UNIT LCD mm (%) LCD mm LCD mm (%)
(%)
52 SIL CERTIFICATION SIL-2 SIL-2 SIL-2

53 MEASURING RANGE (FROM TANK BOTTOM) YES YES YES

54 MODEL NO. FOR SENSOR * * *


OTHERS

55 MODEL NO. FOR TRANSMITTTER * * *

56 MANUFACTURER * * *

57 NOTES:- REFER NOTES SHEET. * To be Furnished by Vendor.


TITLE ITEM/TAG No. DATA SHEET No.

DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER REFER BELOW OIL-100-EK-I-DS-0826
PROJECT DESCRIPTION PROJECT NO. SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 9 OF 10 A0


EPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 30-Nov-18 PG 30-Nov-18 MV 30-Nov-18 Issued For Review
Client Document No.
-
ORIGINATOR ORIG. DATE
VS 30-Nov-18
UNITS:- Pressure bar g kg/cm2 g kPa g psig LEVEL : mm
0 0
Temp C F
1 66-LT-6615 66-LT-6631 71-LT-8008
TAG NO.
2 SKIM OIL OFF-SPEC EFFLUENT WATER FIRE WATER
SERVICE
GENERAL

3 17039-EK-P-DW-0206-04 17039-EK-P-DW-0206-06 17039-EK-P-DW-0217-01


P&ID NO.
4 5800 (I/D) X 8000 (H) 8500 (I/D) X12000 (H) 8300 (I/D) X 10000 (H)
VESSEL SIZE
5 CARBON STEEL + 3mm CA CARBON STEEL + 3mm CA CARBON STEEL + 3mm CA
VESSEL MATERIAL
6 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3 ZONE - 2, Gr IIA & IIB, T3
AREA CLASSIFICATION
7 EK-ABJ-3452 EK-ABJ-3453 EK-ABJ-3110A
TANK NO
8 UPPER FLUID / PHASE SKIM OIL / LIQUID - -

9 LOWER FLUID / PHASE - OFF-SPEC EFFLUENT WATER / LIQUID FIRE WATER / LIQUID

10 INTERFACE - - -
SERVICE CONDITIONS

11 SUSPENDED SOLIDS - - -

12 ATM ATM ATM


PRESSURE (MAX. / NORM. / MIN. )
13 55 51 41
TEMPERATURE (MAX. / NORM. / MIN.)
14 FOL+0.07 / 90 FOL+0.07 / 85 FOL+0.07 / 80
DESIGN (PRESSURE / TEMPERATURE)
15 SPECIFIC GRAVITY 0.8998 1 1

16 DENSITY UPPER LOWER Kg/m3 899.8 1000 1000

17 FLUID VISCOSITY UPPER LOWER cP 3.85 1 1

18 DIELECTRIC CONSTANT UPPER/LOWER 1.4 0.5 0.6

19 THERMAL CONDUCTIVITY LIQUID (UPPER / W/m-K - - -


LOWER)
20 INTERNAL / EXTERNAL

21 CAGE MATERIAL

22 OVER ALL C-C C-C1 C-C2

23 CONNECTION SIZE AND RATING

24 CAGE ORIENTATION / ROTATABLE HEAD


CAGE

25 CAGE TO HEAD FLANGE SIZE & RATING

26 CAGE TO HEAD GASKET / BOLTING

27 DRAIN / VENT CONN. SIZE & RATING

28 COOLING EXTENSION

29 ELECTRICAL HEAT TRACING

30 STAND PIPE

31 TYPE / MODEL Encapsulated Horn / * Encapsulated Horn / * Encapsulated Horn / *


ANTENNA

32 * * *
PROCESS CONNECTION
33 MOC SS 316 SS 316 SS 316
34 * * *
ANTENNA LENGTH DIAMETER * * *
35 VERTICAL VESSEL TOP VERTICAL VESSEL TOP VERTICAL VESSEL TOP
MOUNTING POSITION / MOUNTING LOCATION
Non Contact Type / Non Contact Type / Non Contact Type /
40 TYPE / PRINCIPLE
Pulse-burst radar technology Pulse-burst radar technology Pulse-burst radar technology

41 MOUNTING Direct on vessel Direct on vessel Direct on vessel

42 ACCURACY / INTER FACE ACCURACY ± 0.03% of measured distance / * ± 0.03% of measured distance / * ± 0.03% of measured distance / *

43 REPEATABILITY ± 1mm ± 1mm ± 1mm

44 PROTECTION CLASS/ENCLOSURE IP 65/ Ex'ia' IP 65/ Ex'ia' IP 65/ Ex'ia'


TRANSMITTER

45 POWER SUPPLY 24VDC loop powered with HART 24VDC loop powered with HART 24VDC loop powered with HART

46 OUTPUT 4 - 20 mA 4 - 20 mA 4 - 20 mA

47 PROCESS CONNECTION AND RATING(MOC) 8", 150# RF, SS 316 8", 150# RF, SS 316 8", 150# RF, SS 316

48 CALIBRATION RANGE MIN. / MAX. (%) 0-100% 0-100% 0-100%

49 INSTRUMENT RANGE MIN. / MAX. mm(%) 0-8000 mm (0-100)% 0-12000mm (0-100)% 0-10000 mm (0-100)%

50 CABLE ENTRY | CABLE GLAND WITH PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG

51 LOCAL INDICATION / DISPLAY ENGG. UNIT LCD mm (%) LCD mm (%) LCD mm (%)

52 SIL CERTIFICATION SIL-2 SIL-2 SIL-2

53 MEASURING RANGE (FROM TANK BOTTOM) YES YES YES

54 MODEL NO. FOR SENSOR * * *


OTHERS

55 MODEL NO. FOR TRANSMITTTER * * *

56 MANUFACTURER * * *

57 NOTES:- REFER NOTES SHEET. * To be Furnished by Vendor.


TITLE ITEM/TAG No. DATA SHEET No.

DATA SHEET FOR RADAR TYPE LEVEL TRANSMITTER REFER BELOW OIL-100-EK-I-DS-0826
PROJECT DESCRIPTION PROJECT NO. SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 10 OF 10 A0


EPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - 17039-EK-I-DB-8001
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 VS 30-Nov-18 PG 30-Nov-18 MV 30-Nov-18 Issued For Review
Client Document No.
-
ORIGINATOR ORIG. DATE
VS 30-Nov-18
UNITS:- Pressure bar g kg/cm2 g kPa g psig LEVEL : mm
0 0
Temp C F
1 71-LT-8009
TAG NO.
2 FIRE WATER
SERVICE
GENERAL

3 17039-EK-P-DW-0217-01
P&ID NO.
4 8300 (I/D) X 10000 (H)
VESSEL SIZE
5 CARBON STEEL + 3mm CA
VESSEL MATERIAL
6 ZONE - 2, Gr IIA & IIB, T3
AREA CLASSIFICATION
7 EK-ABJ-3110B
TANK NO
8 UPPER FLUID / PHASE -

9 LOWER FLUID / PHASE FIRE WATER / LIQUID

10 INTERFACE -
SERVICE CONDITIONS

11 SUSPENDED SOLIDS -

12 ATM
PRESSURE (MAX. / NORM. / MIN. )
13 41
TEMPERATURE (MAX. / NORM. / MIN.)
14 FOL+0.07 / 80
DESIGN (PRESSURE / TEMPERATURE)
15 SPECIFIC GRAVITY 1

16 DENSITY UPPER LOWER Kg/m3 1000

17 FLUID VISCOSITY UPPER LOWER cP 1

18 DIELECTRIC CONSTANT UPPER/LOWER 0.6

19 THERMAL CONDUCTIVITY LIQUID (UPPER / W/m-K -


LOWER)
20 INTERNAL / EXTERNAL

21 CAGE MATERIAL

22 OVER ALL C-C C-C1 C-C2

23 CONNECTION SIZE AND RATING

24 CAGE ORIENTATION / ROTATABLE HEAD


CAGE

25 CAGE TO HEAD FLANGE SIZE & RATING

26 CAGE TO HEAD GASKET / BOLTING

27 DRAIN / VENT CONN. SIZE & RATING

28 COOLING EXTENSION

29 ELECTRICAL HEAT TRACING

30 STAND PIPE

31 TYPE / MODEL Encapsulated Horn / *


ANTENNA

32 *
PROCESS CONNECTION
33 MOC SS 316
34 *
ANTENNA LENGTH DIAMETER *
35 VERTICAL VESSEL TOP
MOUNTING POSITION / MOUNTING LOCATION
Non Contact Type /
40 TYPE / PRINCIPLE
Pulse-burst radar technology

41 MOUNTING Direct on vessel

42 ACCURACY / INTER FACE ACCURACY ± 0.03% of measured distance / *

43 REPEATABILITY ± 1mm

44 PROTECTION CLASS/ENCLOSURE IP 65/ Ex'ia'


TRANSMITTER

45 POWER SUPPLY 24VDC loop powered with HART

46 OUTPUT 4 - 20 mA

47 PROCESS CONNECTION AND RATING(MOC) 8", 150# RF, SS 316

48 CALIBRATION RANGE MIN. / MAX. (%) 0-100%

49 INSTRUMENT RANGE MIN. / MAX. mm(%) 0-10000 mm (0-100)%

50 CABLE ENTRY | CABLE GLAND WITH PLUG SIDE ENTRY 1/2" NPT(F) w/ PLUG

51 LOCAL INDICATION / DISPLAY ENGG. UNIT LCD mm (%)

52 SIL CERTIFICATION SIL-2

53 MEASURING RANGE (FROM TANK BOTTOM) YES

54 MODEL NO. FOR SENSOR *


OTHERS

55 MODEL NO. FOR TRANSMITTTER *

56 MANUFACTURER *

57 NOTES:- REFER NOTES SHEET. * To be Furnished by Vendor.


DATA SHEET FOR LEVEL GAUGE (REFLEX TYPE)
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR LEVEL GAUGE (REFLEX TYPE) OIL-100-EK-I-DS-0801 A0 Sheet No.: 02 of 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS - LG (Reflex.Type)
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR LEVEL GAUGE (REFLEX TYPE) OIL-100-EK-I-DS-0801 A0 Sheet No: 03 of 05

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) Revision Index
AT EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR LEVEL GAUGE (REFLEX TYPE) OIL-100-EK-I-DS-0801 A0 Sheet No: 04 of 05

Notes:
1. Documentation required :- Calibration Certificate , Material Certificates to 3.1 as per EN 10204, Hydro test ,
Pressure test Procedure/Report , Operating & Maintenance Instructions & Spare Parts List.
2. Vendor shall supply spare parts for start-up and commissioning, a list of recommended spare parts for 2 years operation & performance warranty.
3. Level Gauges shall be Hydrotested to 1.5 times the process design pressure by the manufacturer prior to shipment.
4. Flange finish shall be in accordance with ANSI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250 AARH and 63 AARH for Ring type joint (RTJ) .
5. Painting shall be as per Protective Coating specification for Onshore Structures and Facilities.
6. Flange connection shall be in accordance with ASME B16.5
7. The external chamber shall be designed and constructed to ASME B31.3
8. All chambers shall be weld-necked type, flanges with raise face and gasket surface finishes shall be in accordance with ASME B16.5.
9. All Level Gauges shall be supplied complete with stainless steel 316 nameplate affixed to the body. Tags shall be Permanently secured. The following information shall be
shown on the name plates as a minimum:manufacturers name & trade mark, type, model no & serial no, Instrument Tag.No, moc, service/ fluid, c-c distance and visible length,
pressure and temperature rating of pressurized parts.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR LEVEL GAUGE (REFLEX TYPE) SEE BELOW TABLE OIL-100-EK-I-DS-0801
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 05 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 30-Nov-18 MV 30-Nov-18 MSR/ VSR 30-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
IMR 03-Oct-18

UNITS: Pressure: kg/cm2 g Temp: ° C Flow: Gas: Liquid: m3/hr


Level: mm
GENERAL OPTIONS
1. Tag Number Refer below Table 20. Mica Shield No
2. Service Refer below Table 21. Illuminator Power Supply NA NA
3. Vessel No. Refer below Table 22. Enclosure Class Cable Entry NA NA
4. Trim No. AC01 23. Power Isolation Switch NA
5. P&ID Number (Sheet No.) Refer below Table 24. Jacket or Internal Tracer NA
6. Area Classification Zone 2, Gas Gr.IIA & IIB, T3 25. Frost Extension Length NA NA
7. Measurement Local Level Measurement 26. Calibrated Scale Yes
8. Vessel Material Carbon Steel + 3mm CA 27.
GAUGE COCKS
9. Type Reflex Type 28. Type Offset Type
10. Sections Required 320 x 1 29. Body Material SS316
11. Connection Size Rating 30. Trim Material SS316
12. Connection Arrangement Side - Side Right 31. Packing Material NA
13. Chamber Material SS316 32. Ball Check Yes
14. Cover Material SS316 33. Vessel Connection Size Rating 2" 150#RF
15. Glass Material Toughened Borosilicate Glass 34. Vessel Connection Arrangement Side - Side
16. Bolts & Nuts Material ASTM A 193 Gr. B7/ ASTM A 194 Gr. 2H as 35. Gauge Connection Size Rating 3/4" NPT -
per ASME B16.5 36. Drain :- Size Rating 3/4" 150#RF
17. Gasket Material 150# SPWND Gasket 4.5mm THK TO 37. Vent :- Size Rating 3/4" 150#RF
ASME B 16.20: Windings - SS316, Filler- 38. Bonnet - Integral / Union / Bolted Union
CNAF, Inner Ring -SS316, Outer Ring- CS
39. Closing - Plain / Quick Quick
40. Renewable Seats Yes

18. Flange Material CS, ASTM A-105


19. Manufacturer *
NOTES
1. For Notes refer Notes section.

Operating Design
Visible C-C Size/
Liquid Model
S.No. Tag Number Service Description P&ID Number Length Distance Press. Temp. Press. Temp. Rating/ Remarks
S.G Number
(mm) (mm) Facing
kg/cm2g °C kg/cm2g °C
Industrial Water Storage 0 - 2500 2"/
1 53-LG-5505 17039-EK-P-DW-0212-01 * Atm. Amb. FOW+0.07 80 0.99 *
Tank (EK-ABJ-3220) (Hold) 150# RF
Industrial Water Storage 0 - 2500 2"/
2 53-LG-5509 17039-EK-P-DW-0212-01 * Atm. Amb. FOW+0.07 80 0.99 *
Tank (EK-ABJ-3220) (Hold) 150# RF
Potable Water Storage Tank 0 - 2500 2"/
3 53-LG-5544 17039-EK-P-DW-0212-04 * Atm. Amb. FOW+0.07 80 0.99 *
(EK-ABJ-3270) (Hold) 150# RF
Potable Water Storage Tank 0 - 2500 2"/
4 53-LG-5535 17039-EK-P-DW-0212-04 * Atm. Amb. FOW+0.07 80 0.99 *
(EK-ABJ-3270) (Hold) 150# RF

* BY VENDOR
DATA SHEET FOR TEMPERATURE TRANSMITTERS
WITH THERMOWELL
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code
DATA SHEET FOR TEMPERATURE TRANSMITTERS
OIL-100-EK-I-DS-0802 A0 Sheet No.: 02 of 07
WITH THERMOWELL

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS - TT
6 DS - TT
7 DS - TT
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code
DATA SHEET FOR TEMPERATURE TRANSMITTERS
OIL-100-EK-I-DS-0802 A0 Sheet No: 03 of 07
WITH THERMOWELL

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) Revision Index
AT EAST KHAGORIJAN Datasheet Number Rev Code

DATA SHEET FOR TEMPERATURE TRANSMITTERS WITH


OIL-100-EK-I-DS-0802 A0 Sheet No: 04 of 07
THERMOWELL

Notes:
1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test , Explosion proof & weather
proof certificate, Pressure test Procedure/Report , SIL 2 Certificate, Operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. All transmitters shall be provided with integral indicator (LCD type) with engineering unit indication.
4. Instrumentation shall meet the Electromagnetic interference requirements according to EN 50081-2 and EN 50082-2.
5. All field transmitters shall be" SMART" type, 2-wire 24VDC loop powered communicating on 4-20mA signal mode with superimposed HART digital transmission
signal for remote calibration and diagnostics from HART maintenance system.
6. Flange finish shall be in accordance with ANSI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250 AARH and 63 AARH for Ring type joint (RTJ) .
7. The housing of all transmitters shall be SS 316 minimum.
8. The element head shall have 2 cable entries, one of which shall be fitted with a certified plug.
9. All Transmitters shall be provided with SIL-2 (min) certification.
10. The over-range/static pressure protection of the transmitter shall be 130% of range.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR TEMPERATURE TRANSMITTERS WITH THERMOWELL SEE BELOW TABLE OIL-100-EK-I-DS-0802
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 07 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
IMR 14-Sep-18
UNITS: Pressure: kg/cm2 g Temp: °C Flow: Gas:
MMSCFD Liquid: m3/hr

TEMPERATURE TRANSMITTER
1. Mounting Direct Mounted 8. Housing Material Polyurethane Coated Aluminum
2. Accuracy ± 0.1% of FSD 9. Bracket & Bolt Material NA
3. Temp. Limit 8°C to 45°C 10. Enclosure Rating IP 65
4. Output 4-20 mAdc, HART Protocol with SMART Tr. 11. Area Classification Zone 1, Gas Group IIA&IIB, Temp. Cl T3
5. Power Supply 24 VDC Loop powered 12. Equipment Certification IEC EEx'd'
6. Indicating Yes. LCD in engineering unit 13. Manufacturer *
7. Electrical Connection 1/2" NPT(F) 14. Model Number Note-3

TEMPERATURE ELEMENT
1. Element Type 3-Wire, pt-100, 100Ω at 0 deg.C, RTD, IEC 751, Class A 7. Head Material NA
2. Number of Element Single (a = 0.00385) 8. Terminal Block Yes
3. Sensor Diameter 1/4" 9. Screw Cap & Chain NA
4. Sheath Material SS 316 10. Electrical Connection NA
5. Spring Loaded Yes 11. Manufacturer *
6. Extension Type / Length NA

THERMOWELL
1. Included Yes 7. Bore Diameter 0.26"
2. Material 316 stainless steel 8. Element Connection 1/2" NPT
3. Construction Solid drilled & Tapered 9. Process Connection See below

NOTES
1) Each instrument shall include a SS tag permanently attached to the instrument using SS screws, SS bolts or ss wire.
2) Transmitter, Temperature Sensor & Thermowell shall be assembled and tagged individually.
3) Temperature Transmitter Model Number: *
Temperature Element Model Number: *
Thermowell Model Number: *

Temp. Nozzle
Calibrated Design T/W Flange
(Design/ Line Velocity Projetion Model
S.No. Tag Number Service Description P&ID Number Range Pressure "U"/ Lag. Size & Remarks
Normal) Insulation (m/s) Length Number
Deg.C Kg/cm2g mm Rating
Deg.C (mm)
41-TT-3751/ Hot Oil return header TCV 90/ 2"/
1 41-TE-3751/ 17039-EK-P-DW-0202-13 0 - 100 FOW+0.07 NA 500 0.1 150
Temp. Control (27-50) 150# RF
41-TW-3751
20-TT-1387A/
90/ 2"/
2 20-TE-1387A/ Crude Oil Test Tank 17039-EK-P-DW-0202-20 0 - 100 FOW+0.07 NA 500 0.1 150
(27-50) 150# RF
20-TW-1387A
20-TT-1387B/
90/ 2"/
3 20-TE-1387B/ Crude Oil Test Tank 17039-EK-P-DW-0202-20 0 - 100 FOW+0.07 NA 500 0.1 150
(27-50) 150# RF
20-TW-1387B
20-TT-1387C/
90/ 2"/
4 20-TE-1387C/ Crude Oil Test Tank 17039-EK-P-DW-0202-20 0 - 100 FOW+0.07 NA 500 0.1 150
(27-50) 150# RF
20-TW-1387C
20-TT-0991/
Hot Oil return header TCV 2"/
5 20-TE-0991/ 17039-EK-P-DW-0203-10 0 - 100 90/ 55 FOW+0.07 NA 500 0.1 150
Temp. Control 150# RF
20-TE-0991
20-TT-0990A/
Treated Crude Storage Tank 2"/
6 20-TE-0990A/ 17039-EK-P-DW-0203-10 0 - 100 90/ 55 FOW+0.07 NA 500 0.1 150
(ND-BBJ-1120A) 150# RF
20-TW-0990A
20-TT-0990B/
Treated Crude Storage Tank 2"/
7 20-TE-0990B/ 17039-EK-P-DW-0203-10 0 - 100 90/ 55 FOW+0.07 NA 500 0.1 150
(ND-BBJ-1120A) 150# RF
20-TW-0990B
20-TT-0990C/
Treated Crude Storage Tank 2"/
8 20-TE-0990C/ 17039-EK-P-DW-0203-10 0 - 100 90/ 55 FOW+0.07 NA 500 0.1 150
(ND-BBJ-1120A) 150# RF
20-TW-0990C
20-TT-0992/
Hot Oil return header TCV 2"/
9 20-TE-0992/ 17039-EK-P-DW-0203-11 0 - 100 90/ 55 FOW+0.07 NA 500 0.1 150
Temp. Control 150# RF
20-TW-0992
20-TT-0998A/
Treated Crude Storage Tank 2"/
10 20-TE-0998A/ 17039-EK-P-DW-0203-11 0 - 100 90/ 55 FOW+0.07 NA 500 0.1 150
(ND-BBJ-1120B) 150# RF
20-TW-0998A
20-TT-0998B/
Treated Crude Storage Tank 2"/
11 20-TE-0998B/ 17039-EK-P-DW-0203-11 0 - 100 90/ 55 FOW+0.07 NA 500 0.1 150
(ND-BBJ-1120B) 150# RF
20-TW-0998B
* To be Provided By Vendor.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR TEMPERATURE TRANSMITTERS WITH THERMOWELL SEE BELOW TABLE OIL-100-EK-I-DS-0802
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 06 OF 07 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
IMR 14-Sep-18
UNITS: Pressure: kg/cm2 g Temp: °C Flow: Gas:
MMSCFD Liquid: m3/hr

TEMPERATURE TRANSMITTER
1. Mounting Direct Mounted 8. Housing Material Polyurethane Coated Aluminum
2. Accuracy ± 0.1% of FSD 9. Bracket & Bolt Material NA
3. Temp. Limit 8°C to 45°C 10. Enclosure Rating IP 65
4. Output 4-20 mAdc, HART Protocol with SMART Tr. 11. Area Classification Zone 1, Gas Group IIA&IIB, Temp. Cl T3
5. Power Supply 24 VDC Loop powered 12. Equipment Certification IEC EEx'd'
6. Indicating Yes. LCD in engineering unit 13. Manufacturer *
7. Electrical Connection 1/2" NPT(F) 14. Model Number Note-3

TEMPERATURE ELEMENT
1. Element Type 3-Wire, pt-100, 100Ω at 0 deg.C, RTD, IEC 751, Class A 7. Head Material NA
2. Number of Element Single (a = 0.00385) 8. Terminal Block Yes
3. Sensor Diameter 1/4" 9. Screw Cap & Chain NA
4. Sheath Material SS 316 10. Electrical Connection NA
5. Spring Loaded Yes 11. Manufacturer *
6. Extension Type / Length NA

THERMOWELL
1. Included Yes 7. Bore Diameter 0.26"
2. Material 316 stainless steel 8. Element Connection 1/2" NPT
3. Construction Solid drilled & Tapered 9. Process Connection See below

NOTES
1) Each instrument shall include a SS tag permanently attached to the instrument using SS screws, SS bolts or ss wire.
2) Transmitter, Temperature Sensor & Thermowell shall be assembled and tagged individually.
3) Temperature Transmitter Model Number: *
Temperature Element Model Number: *
Thermowell Model Number: *

Temp. Nozzle
Calibrated Design T/W Flange
(Design/ Line Velocity Projetion Model
S.No. Tag Number Service Description P&ID Number Range Pressure "U"/ Lag. Size & Remarks
Normal) Insulation (m/s) Length Number
Deg.C Kg/cm2g mm Rating
Deg.C (mm)
20-TT-0998C/
Treated Crude Storage Tank 2"/
12 20-TE-0998C/ 17039-EK-P-DW-0203-11 0-100 90/ 55 FOW+0.07 NA 500 0.1 150
(ND-BBJ-1120B) 150# RF
20-TW-0998C
Hot Oil return header TCV 2"/
13 20-TIT-0431 17039-EK-P-DW-0203-14 0-100 90/ 55 FOW+0.07 NA 500 0.1 150
Temp. Control 150# RF
20-TT-0428A/
Off Spec crude storage Tank 2"/
14 20-TE-0428A/ 17039-EK-P-DW-0203-14 0-100 90/ 55 FOW+0.07 NA 500 0.1 150
(ND-BBJ-1090) 150# RF
20-TW-0428A
20-TT-0428B/
Off Spec crude storage Tank 2"/
15 20-TE-0428B/ 17039-EK-P-DW-0203-14 0-100 90/ 55 FOW+0.07 NA 500 0.1 150
(ND-BBJ-1090) 150# RF
20-TW-0428B
20-TT-0428C/
Off Spec crude storage Tank 2"/
16 20-TE-0428C/ 17039-EK-P-DW-0203-14 0-100 90/ 55 FOW+0.07 NA 500 0.1 150
(ND-BBJ-1090) 150# RF
20-TW-0428C
66-TIT-6622
Hot Oil return header TCV 2"/
17 66-TE-6622/ 17039-EK-P-DW-0206-04 0-100 90 / 55 FOL+0.07 NA 500 0.1 150
Temp. Control 150# RF
66-TW-6622
66-TT-6620/
Skim Oil Tank 2"/
18 66-TE-6620/ 17039-EK-P-DW-0206-04 0-100 90 / 55 FOL+0.07 NA 500 0.1 150
(ND-ABJ-3452) 150# RF
66-TW-6620
* To be Provided By Vendor.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR TEMPERATURE TRANSMITTERS WITH THERMOWELL SEE BELOW TABLE OIL-100-EK-I-DS-0802
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 07 OF 07 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
IMR 14-Sep-18
UNITS: Pressure: kg/cm2 g Temp: °C Flow: Gas:
MMSCFD Liquid: m3/hr

TEMPERATURE TRANSMITTER
1. Mounting Direct Mounted 8. Housing Material Polyurethane Coated Aluminum
2. Accuracy ± 0.1% of FSD 9. Bracket & Bolt Material NA
3. Temp. Limit 8°C to 45°C 10. Enclosure Rating IP 65
4. Output 4-20 mAdc, HART Protocol with SMART Tr. 11. Area Classification Zone 1, Gas Group IIA&IIB, Temp. Cl T3
5. Power Supply 24 VDC Loop powered 12. Equipment Certification IEC EEx'd'
6. Indicating Yes. LCD in engineering unit 13. Manufacturer *
7. Electrical Connection 1/2" NPT(F) 14. Model Number Note-3

TEMPERATURE ELEMENT
1. Element Type 3-Wire, pt-100, 100Ω at 0 deg.C, RTD, IEC 751, Class A 7. Head Material NA
2. Number of Element Single (a = 0.00385) 8. Terminal Block Yes
3. Sensor Diameter 1/4" 9. Screw Cap & Chain NA
4. Sheath Material SS 316 10. Electrical Connection NA
5. Spring Loaded Yes 11. Manufacturer *
6. Extension Type / Length NA

THERMOWELL
1. Included Yes 7. Bore Diameter 0.26"
2. Material 316 stainless steel 8. Element Connection 1/2" NPT
3. Construction Solid drilled & Tapered 9. Process Connection See below

NOTES
1) Each instrument shall include a SS tag permanently attached to the instrument using SS screws, SS bolts or ss wire.
2) Transmitter, Temperature Sensor & Thermowell shall be assembled and tagged individually.
3) Temperature Transmitter Model Number: *
Temperature Element Model Number: *
Thermowell Model Number: *

Temp. Nozzle
Calibrated Design T/W Flange
(Design/ Line Velocity Projetion Model
S.No. Tag Number Service Description P&ID Number Range Pressure "U"/ Lag. Size & Remarks
Normal) Insulation (m/s) Length Number
Deg.C Kg/cm2g mm Rating
Deg.C (mm)
Eff.Water to Eff.Water 11/2"*&
19 44-TT-8044 17039-EK-P-DW-0203-21 0-100 90/55 FOW+0.07 NA 230 150
Storage Tank 150#RF
Eff.Water to Eff.Water 11/2"*&
20 44-TT-8045 17039-EK-P-DW-0203-21 0-100 90/55 FOW+0.07 NA 230 150
Storage Tank 150#RF
Eff.Water to Eff.Water 11/2"*&
21 44-TT-8044B 17039-EK-P-DW-0203-22 0-100 90/55 FOW+0.07 NA 230 150
Storage Tank 150#RF
Eff.Water to Eff.Water 11/2"*&
22 44-TT-8045B 17039-EK-P-DW-0203-22 0-100 90/55 FOW+0.07 NA 230 150
Storage Tank 150#RF

* To be Provided By Vendor.
DATA SHEET FOR CORIOLIS FLOW METER
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (GGS)
Rev
AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR CORIOLIS FLOW METER OIL-100-EK-I-DS-0803 A0 SHEET 02 OF 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS-CORIOLIS FLOWMETER (FISCAL FLOW METER)
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (GGS)
Rev
AT EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR CORIOLIS FLOW METER OIL-100-EK-I-DS-0803 A0 SHEET 03 OF 05

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT
Rev
EAST KHAGORIJAN Datasheet Number
Code

DATA SHEET FOR CORIOLIS FLOW METER OIL-100-EK-I-DS-0803 A0 Sheet No.: 04 of 05

Notes Sheet

1. Documentation required :- Calibration certificate,Material certificates to 3.1 as per EN10204, weather proof to IP65 certificate by ATEX or Equivalent body,
Pressure test procedure/Report, NDT procedure / Report, Operating and Maintenance Instructions & Spare Parts List.
2. Coriolis flow meter shall be provided with 1 mm thick, 30mm x 75mm SS 316 tag plate, inscribed with tag number engraved or embossed
in 5mm high and 0.3mm deep bold characters and black paint filled. The tags shall be mounted on or adjacent to the associated
instrument and either fixed with stainless steel screws or attached with stainless steel wire.
3. Coriolis meters shall be designed to ISO 10790.
4. All stud bolt material shall be ASTM A 193 Gr. B7 / ASME B16.5 (Hot dip galvanized).
5. The Coriolis Meter shall be provided with a local LCD display with Engineering unit indication.
6. Instrument shall meet the Electromagnetic Interference requirements to EN50082-2 / IEC 60533.
7. All weldings and castings (if any) shall be 100% radiographed.
8. Any special cable between the sensor transmitter & receiver electronics to be provided by flow meter vendor.
9. Transmitter shall be provided with dual cable entries. Unused cable entries shall be provided with explosion proof plugs of SS 316.
10. Coriolis meter shall be Ex"ia" in accordance with IEC 60079. In the event of Ex"ia" is not available or cannot be used then Ex"d" type of
protection shall be used and notified to the buyer for approval.
11. Mass flow meters shall be of Coriolis - two tube design.
12. Coriolis Mass Flow Meter shall be of in-line mounting design with flow direction clearly marked on the flow tube body to ensure
proper installation.
13. Flanged end connection and Flange face finish of the Coriolis Mass Flow Meter shall be as per ASME B 16.5.
14. Meter body shall be hydrostatically tested as per requirement specified in relevant clause of ASME F 423.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR CORIOLIS FLOW METER REFER BELOW OIL-100-EK-I-DS-0803
PROJECT DESCRIPTION PROJECT NO. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 05 OF 05 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/VSR 28-Nov-18 Issued for Review
CLIENT DOC .No
-
ORIGINATOR ORIG. DATE
IMR 13-Sep-18
UNITS:- Pressure bar g kg/cm 2 g kPa g psig Flow : Gas MMSCFD Sm 3/hr kg/hr
0 0
Temp C F Liquid m3/hr kg/hr KLPD lit / hr
1 TAG NO. 20-FT-2008 20-FT-2009

2 QUANTITY ONE ONE

3 LINE No. 3"-PL-20-2402-AC01 3"-PL-20-2403-AC01

4 P & ID No. 17039-ND-P-DW-0219-01 17039-ND-P-DW-0219-01


GENERAL 5 LINE SIZE/SCH 3" / STD 3" / STD

6 LINE INSULATION NO NO

7 SERVICE CRUDE OIL CRUDE OIL

8 AREA CLASSIFICATION ZONE-2, Gr IIA & IIB, T3 ZONE-2, Gr IIA & IIB, T3

9 ENCLOSURE IP 65, Ex 'ia' IP 65, Ex 'ia'

10 SIZE RATING 3" 150#RF 3" 150#RF

11 END CONNECTION & FACE FINISH FLANGED 125 - 250 AARH FLANGED 125 - 250 AARH

12 END CONNECTION FLANGE MATERIAL CARBON STEEL A216 WCB CARBON STEEL A216 WCB
METER TYPE &
13 SENSOR SPOOL PIECE MATERIAL CARBON STEEL A216 WCB CARBON STEEL A216 WCB
MATERIAL
14 SENSOR MATERIAL SS 316 SS 316

15 OTHER WETTED PARTS MATERIAL SS 316 SS 316

16 ENCLOSURE MATERIAL SS 316 SS 316

17 POWER SUPPLY 230 VAC / 60 Hz 230 VAC / 60 Hz


4-20mA, DC, SMART type with HART
TRANSMITTER 18 OUTPUT Protocol
4-20mA, DC, SMART type with HART Protocol
SUPPLY & SIGNAL ZONE-2, Gr IIA & IIB, T3 ZONE-2, Gr IIA & IIB, T3
19 AREA CLASSIFICATION
20 ENCLOSURE MATERIAL SS 316 SS 316

21 MEASURING RANGE (CALIBRATED FLOW) * *

22 ADJUSTABLE RANGE - -

23 ACCURACY +/- 0.1 % +/- 0.1 %

24 SENSITIVITY - -
FLOW METER
25 REPEATABILITY RANGEABILITY - 100:1 - 100:1
DATA
AUTOMATIC TEMPERATURE
AUTOMATIC TEMPERATURE COMPENSATION
26 EFFECT OF TEMPERATURE COMPENSATION

27 MINIMUM DETECTION LIMIT - -

28 CABLE ENTRY CONNECTION ISO M20 (METRIC) ISO M20 (METRIC)

29 FLUID AND STATE CRUDE OIL / LIQUID CRUDE OIL / LIQUID

30 TEMPERATURE: OPERATING / DESIGN 55 90 (Hold) 55 90 (Hold)

31 PRESSURE: OPERATING / DESIGN 10 15 (Hold) 10 15 (Hold)

32 ALLOWABLE PRESS. DROP ACROSS METER 0.3 (Hold) 0.3 (Hold)

33 OPERATING VISCOSITY (Cp) 3.8 (Hold) 3.8 (Hold)


SERVICE 3 @ OT °C
34 DENSITY kg/m MOLECULAR WEIGHT 900 - 900 -
CONDITIONS
35 FLOW (MIN / NORMAL / MAX) m3/day - - 600 (Hold) - - 600 (Hold)

36 WATER CONTENT: (m3/day) MAXIMUM 3.1 (Hold) 3.1 (Hold)

37 NORMAL - -

38 MINIMUM - -

39 SALINITY - -

40 LOCAL DISPLAY YES YES

41 MODEL NO. FOR SENSOR * *


OTHERS
42 MODEL NO. FOR TRANSMITTTER * *

43 MANUFACTURER * *
NOTES:-

REFER SHEET 4
DATA SHEET FOR CONTROL VALVES
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATASHEET FOR CONTROL VALVES OIL-100-EK-I-DS-0807 A0 SHEET 2 OF 10

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 41-TV-3751
6 41-TV-0991
7 41-TV-0992
8 41-TV-0431
9 66-TV-6622
10 66-TV-6635
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATASHEET FOR CONTROL VALVES OIL-100-EK-I-DS-0807 A0 SHEET 3 OF 10

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (GGS) AT EAST KHAGORIJAN Datasheet Number
Code

DATASHEET FOR CONTROL VALVES OIL-100-EK-I-DS-0807 A0 SHEET 4 OF 10

NOTES SHEET

1 Documentation required :- Calibration Certificate, Material Certificates to 3.1 as per EN10204, weather proof certificate, Pressure test procedure/Report,
NDT Procedure/ report, Certified by CMRI, Operating & Maintenance Instructions & Spare Parts List.
2 All control valves to be supplied with SS 316 Name plate with Tag no. and details engraved .The tag plate shall be permanently secured.
3 Control valve sizing shall be as per ISA-75.01.
4 Flange finish shall be in accordance with relevant piping class and ANSI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250AARH .
5 Valve positioner shall be" SMART" type, 2-wire 24VDC loop powered communicating on 4-20mA signal mode with superimposed HART digital transmission signal.
6 The air filter regulator shall be provided with manual drainage facility, an integral pressure gauage and suitable for the design pressure, materials of construction
for body, spring case and bowl shall be SS316.
7 All Casting valve body and bonnet shall be 100% Radio graphed.
8 Valve bonnet shall have fully retained gasket.
9 The direction of flow through a valve shall be permanently marked on the body in the form of a casting stamping or permanently fixed “arrow” plate.
10 The Valves above 25Kgs shall be provided with eye bolts as per requirement for site handling.
11 The size of control valve shall be calculated from the rates of flow and pressure drops under design conditions.
12 All positioners shall be capable of both direct and reverse action and the design shall allow easy reversal in the field.
13 All positioner shall be supplied with two Pressure gauges for air supply pressure indication and regulator signal pressure indication.
14 The control valve shall be suitable for installation in horizondal as well in vertical lines.
15 Vendor shall examine each control valve for noise generation posibilities. The noise level shall be calculated as per ISA 75.17 or any other equivalent standard
16 Control valves shall meet design pressure and temperature ratings as indicated in the manual valve data sheet.
17 Actuator spring shall be corrosion reistant and shall be cadmium or nickel plated. Alternately vendor standard coating shall also be acceptable These shall be of the
enclosed type. The compression of the springs shall be adjustable.
18 Valve stem position indicator shall be provided for every control valve. The position indicator scale shall be marked from 0 to 100% in steps of 10%.
19 The hand wheel actuator shall be sized to provide the required thrust for valve positioning with 178N force applied to the hand wheel.
20 The valve actuator colour shall be Fail close valve - Red RAL colour 3000 and Fail open valve – Green RAL colour 6002.
21 Valve packing containing asbestos in any form is strictly prohibited
22 Actuator housing material shall be steel or anodised aluminium.
23 All brackets, fixings and fittings shall be constructed from 316 SS.
24 All valves shall be subject to NDE/NDT in accordance with ASME B16.34
25 Design life shall be 20 years.
26 Minimum, normal and maximum ambient temperature are 20°C, 26°C and 30°C.
27 Painting shall be as per Protective Coating specification for Onshore Structures and Facilities.

REFERENCE DOCUMENTS:
17039-EK-I-DB-8001_Functional specification for package instruments_Rev C

17039-CM-M-SP-2001_Piping material specification_Rev D

17039-CM-M-SP-2002_Valve material specificatio_Rev D


TITLE ITEM/TAG No. DATA SHEET No.

DATASHEET FOR CONTROL VALVES 41-TV-3751 OIL-100-EK-I-DS-0807

PROJECT DESCRIPTION PROJECT NO SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 5 OF 10 A0

MPC CONTRACTOR PURCHASE ORDER No. REQUISITION No. SPECIFICATION No.

TBA - - 17039-EK-I-DB-8001

CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION

OIL INDIA LIMITED A0 VS 27-Nov-18 PGN 27-Nov-18 MV 27-Nov-18 ISSUED FOR REVIEW

CLIENT DOCUMENT No.

ORIGINATOR ORIG. DATE

VS 27-Nov-18
UNITS:- Pressure barg Kg/cm2(g) bara psi g Flow : Gas: MMSCFD Sm3/hr m3/hr kg/hr
0 0 3
Temp C F Liquid: m /hr kg/hr USGPM KLPD
1 FLUID CRUDE OIL TYPE NON-CORROSIVE CRIT. PRESS : 14.5 kg/cm2
2 UNITS MAXIMUM FLOW NORMAL FLOW MINIMUM FLOW ΔP SHUTOFF ΔP SIZING
3 FLOW RATE KLPD 27 23 20
4 INLET PRESSURE Kg/cm2(g) 4.5
5 OUTLET PRESSURE Kg/cm2(g) 4.0
O
6 INLET TEMPERATURE C 100 27 - 50 27 - 50
7 SPEC WT/SPEC GRAV/MOL WT 0.839
8 VISCOSITY/SPEC HEAT RATIO cP 2.887
9 VAPOUR PRESSURE Pv Kg/cm2(g) 0.0133
10 REQUIRED Cv (Cg)
11 TRAVEL %
12 ALLOWABLE dBA ≤ 85 ≤ 85 ≤ 85
13 COMPRESSIBILITY FACTOR
17039-EK-P-DW-0202-13/
14 P&ID No & LINE No: 56 ACTUATOR (PNEUMATIC)
2"-HM-41-3752-BC01-HC
15 PIPE LINE SIZE IN / OUT 2"/ 2" 57 TYPE SPRING RETURN DIAPHRAGM
16 SCHEDULE mm XS 58 MFR & MODEL *
17 PIPE LINE INSULATION / STEAM TRACING 1" HEAT CONSERVATION / NA 59 SIZE * EFF AREA *
18 DESIGN PRESS. & TEMP. 12 & 250 60 ON/OFF NA MODULATING YES
19 61 MAX. STROKING TIME *
20 VALVE BODY/BONNET 62 SPRING ACTION OPEN/CLOSE CLOSE
21 TYPE VALVE SPEC GLOBE GVBC01Z 63 MAX ALLOWABLE PRESSURE *
22 SIZE 1" 64 MIN REQUIRED PRESSURE *
23 MAX. PRESS./TEMP. TO SUIT DESIGN CONDITION 65 AVAILABLE AIR SUPPLY PRESSURE
24 MFR & MODEL * 66 MAX 8.5 NOR - MIN 6.5
25 SERIAL NUMBER * 67 BENCH RANGE Kg/cm2(g) *
26 BODY / BONNET MATERIAL CARBON STEEL A105 68 ACT ORIENTATION TOP
27 LINER MATERIAL/CORR. ALLOWANCE PTFE / 3mm 69 HANDWHEEL TYPE HEAVY DUTY
28 END CONNECTION IN : * / 300# RF 70 AIR FAILURE VALVE CLOSE
29 OUT : * / 300# RF 71 PNEUMATIC CONNECTION 1/4"
30 FLANGE FACE FINISH 125 - 250 AARH 72 DIAPHGRAM MATERIAL *
31 BONNET TYPE BOLTED 73 POSITIONER (41-TY-3751)
32 FLOW DIRECTION OVER 74 TYPE : ELECTRO-PNEUMATIC (SMART)
33 LUB & ISOLATION VALVE NA 75 MFR & MODEL *
34 PACKING MATERIAL EXPANDED GRAPHITE 76 ON INCR SIGNAL OUTPUT INCR/DECR INCR
35 PACKING TYPE GRAFOIL 77 GAUGES BYPASS YES NO
36 78 CAM CHARACTERISTIC *

37 TRIM 79 HOUSING PROTECTION / MATERIAL IP 65, Ex "ia" / SS 316

38 TYPE STANDARD 80 PORT CONNECTION 1/4" NPT


39 SIZE RATED TRAVEL * * 81 AIRSET
40 CHARACTERISTIC EQUAL % 82 MFR & MODEL *
41 BALANCED/UNBALANCED UNBALANCED 83 SET PRESSURE (ADJUSTABLE) Kg/cm2(g)
42 RATED Cv * 84 FILTER ELEMENT GAUGES SINTERED BRONZE YES
43 PLUG MATERIAL A182 F316, STELLITED 85 FILTER SIZE 5 MICRON
44 SEAT MATERIAL A182 F316, STELLITED 86 AIRSET & FILTER MATERIAL SS 316
45 CAGE/GUIDE MATERIAL A182 F316, STELLITED 87 PNEUMATIC CONNECTION 1/4" NPT
46 STEM MATERIAL A182 F316, STELLITED 88 BOLT ADJUSTMENT SET POINT *
47 ACCESSORIES 89 TESTS
48 HAZARDOUS AREA CLASSIFICATION ZONE - 2, Gr IIA & IIB, T3 90 HYDRO TEST/ PRESSURE YES / 1.5 TIMES OF DESIGN PRESSURE
49 ENCLOSURE PROTECTION IP 65 91 ANSI/FCI LEAKAGE CLASS ANSI FCI 70.2 (LATEST REVISION) / Class IV
50 GAUGES SHALL BE IN 'Kg/cm2(g)' UNITS YES 92 CV / DEAD BAND TEST NA

51 CABLE ENTRY 1/2" NPTF 93 ACTUATOR LEAKAGE TEST NA

ASTM A 193 Gr. B7 / ASME B16.5 &


300# SPWND Gasket 4.5mm THK TO ASME B
52 STUD,BOLT, NUTS & GASKETS 94 CALIBRATION AND HYSTERESIS TEST NA
16.20: Windings - SS316, Filler- CNAF, Inner
Ring -SS316, Outer Ring- CS
53 TUBING: 1/4" 95 PERFORMANCE TEST NA

54 TUBE FITTING: 0.035" THICKNESS SS 316 96 FUNCTIONAL TEST FOR ALL ACCESSORIES REQUIRED

55 97 IBR CERTIFICATE REQUIRED, FORM IIIC


NOTES:- * - BY VENDOR

REFER NOTES SHEET.


TITLE ITEM/TAG No. DATA SHEET No.

DATASHEET FOR CONTROL VALVES 41-TV-0991 OIL-100-EK-I-DS-0807

PROJECT DESCRIPTION PROJECT NO SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 6 OF 10 A0

MPC CONTRACTOR PURCHASE ORDER No. REQUISITION No. SPECIFICATION No.

TBA - - 17039-EK-I-DB-8001

CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION

OIL INDIA LIMITED A0 VS 27-Nov-18 PGN 27-Nov-18 MV 27-Nov-18 ISSUED FOR REVIEW

CLIENT DOCUMENT No.

ORIGINATOR ORIG. DATE

VS 27-Nov-18
UNITS:- Pressure barg Kg/cm2(g) bara psi g Flow : Gas: MMSCFD Sm3/hr m3/hr kg/hr
0 0 3
Temp C F Liquid: m /hr kg/hr USGPM KLPD
1 FLUID CRUDE OIL TYPE NON-CORROSIVE CRIT. PRESS : 14.5 kg/cm2
2 UNITS MAXIMUM FLOW NORMAL FLOW MINIMUM FLOW ΔP SHUTOFF ΔP SIZING
3 FLOW RATE KLPD 28 24 21
4 INLET PRESSURE Kg/cm2(g) 4.5
5 OUTLET PRESSURE Kg/cm2(g) 4.0
O
6 INLET TEMPERATURE C 100 100 100
7 SPEC WT/SPEC GRAV/MOL WT 0.834
8 VISCOSITY/SPEC HEAT RATIO cP 2.887
9 VAPOUR PRESSURE Pv Kg/cm2(g) 0.0133
10 REQUIRED Cv (Cg)
11 TRAVEL %
12 ALLOWABLE dBA ≤ 85 ≤ 85 ≤ 85
13 COMPRESSIBILITY FACTOR
17039-EK-P-DW-0203-10/
14 P&ID No & LINE No: 56 ACTUATOR (PNEUMATIC)
3"-HM-41-3729-BC01-1N
15 PIPE LINE SIZE IN / OUT 3"/ 3" 57 TYPE SPRING RETURN DIAPHRAGM
16 SCHEDULE mm STD 58 MFR & MODEL *
17 PIPE LINE INSULATION / STEAM TRACING 1 1/2" HEAT CONSERVATION / NA 59 SIZE * EFF AREA *
18 DESIGN PRESS. & TEMP. 12 & 250 60 ON/OFF NA MODULATING YES
19 61 MAX. STROKING TIME *
20 VALVE BODY/BONNET 62 SPRING ACTION OPEN/CLOSE CLOSE
21 TYPE VALVE SPEC GLOBE GVBC01R 63 MAX ALLOWABLE PRESSURE *
22 SIZE 2" 64 MIN REQUIRED PRESSURE *
23 MAX. PRESS./TEMP. TO SUIT DESIGN CONDITION 65 AVAILABLE AIR SUPPLY PRESSURE
24 MFR & MODEL * 66 MAX 8.5 NOR - MIN 6.5
25 SERIAL NUMBER * 67 BENCH RANGE Kg/cm2(g) *
26 BODY / BONNET MATERIAL CARBON STEEL A105 / A216 WCB 68 ACT ORIENTATION TOP
27 LINER MATERIAL/CORR. ALLOWANCE PTFE / 3mm 69 HANDWHEEL TYPE HEAVY DUTY
28 END CONNECTION IN : * / 300# RF 70 AIR FAILURE VALVE CLOSE
29 OUT : * / 300# RF 71 PNEUMATIC CONNECTION 1/4"
30 FLANGE FACE FINISH 125 - 250 AARH 72 DIAPHGRAM MATERIAL *
31 BONNET TYPE BOLTED 73 POSITIONER (41-TY-0991)
32 FLOW DIRECTION OVER 74 TYPE : ELECTRO-PNEUMATIC (SMART)
33 LUB & ISOLATION VALVE NA 75 MFR & MODEL *
34 PACKING MATERIAL EXPANDED GRAPHITE 76 ON INCR SIGNAL OUTPUT INCR/DECR INCR
35 PACKING TYPE GRAFOIL 77 GAUGES BYPASS YES NO
36 78 CAM CHARACTERISTIC *

37 TRIM 79 HOUSING PROTECTION / MATERIAL IP 65, Ex "ia"/ SS 316

38 TYPE STANDARD 80 PORT CONNECTION 1/4" NPT


39 SIZE RATED TRAVEL * * 81 AIRSET
40 CHARACTERISTIC EQUAL % 82 MFR & MODEL *
41 BALANCED/UNBALANCED UNBALANCED 83 SET PRESSURE (ADJUSTABLE) Kg/cm2(g)
42 RATED Cv * 84 FILTER ELEMENT GAUGES SINTERED BRONZE YES
43 PLUG MATERIAL A182 F316, STELLITED 85 FILTER SIZE 5 MICRON
44 SEAT MATERIAL A182 F316, STELLITED 86 AIRSET & FILTER MATERIAL SS 316
45 CAGE/GUIDE MATERIAL A182 F316, STELLITED 87 PNEUMATIC CONNECTION 1/4" NPT
46 STEM MATERIAL A182 F316, STELLITED 88 BOLT ADJUSTMENT SET POINT *
47 ACCESSORIES 89 TESTS
48 HAZARDOUS AREA CLASSIFICATION ZONE - 2, Gr IIA & IIB, T3 90 HYDRO TEST/ PRESSURE YES / 1.5 TIMES OF DESIGN PRESSURE
49 ENCLOSURE PROTECTION IP 65 91 ANSI/FCI LEAKAGE CLASS ANSI FCI 70.2 (LATEST REVISION) / Class IV

50 GAUGES SHALL BE IN 'Kg/cm2(g)' UNITS YES 92 CV / DEAD BAND TEST NA

51 CABLE ENTRY 1/2" NPTF 93 ACTUATOR LEAKAGE TEST NA

ASTM A 193 Gr. B7 / ASME B16.5 &


300# SPWND Gasket 4.5mm THK TO ASME B
52 STUD,BOLT, NUTS & GASKETS 94 CALIBRATION AND HYSTERESIS TEST NA
16.20: Windings - SS316, Filler- CNAF, Inner
Ring -SS316, Outer Ring- CS
53 TUBING: 1/4" 95 PERFORMANCE TEST NA

54 TUBE FITTING: 0.035" THICKNESS SS 316 96 FUNCTIONAL TEST FOR ALL ACCESSORIES REQUIRED

55 97 IBR CERTIFICATE REQUIRED, FORM IIIC


NOTES:- * - BY VENDOR

REFER NOTES SHEET.


TITLE ITEM/TAG No. DATA SHEET No.

DATASHEET FOR CONTROL VALVES 41-TV-0992 OIL-100-EK-I-DS-0807

PROJECT DESCRIPTION PROJECT NO SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 7 OF 10 A0

MPC CONTRACTOR PURCHASE ORDER No. REQUISITION No. SPECIFICATION No.

TBA - - 17039-EK-I-DB-8001

CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION

OIL INDIA LIMITED A0 VS 27-Nov-18 PGN 27-Nov-18 MV 27-Nov-18 ISSUED FOR REVIEW

CLIENT DOCUMENT No.

ORIGINATOR ORIG. DATE

VS 27-Nov-18
UNITS:- Pressure barg Kg/cm2(g) bara psi g Flow : Gas: MMSCFD Sm3/hr m3/hr kg/hr
0 0
Temp C F Liquid: m3/hr kg/hr USGPM KLPD
1 FLUID CRUDE OIL TYPE NON-CORROSIVE CRIT. PRESS : 14.5 kg/cm2
2 UNITS MAXIMUM FLOW NORMAL FLOW MINIMUM FLOW ΔP SHUTOFF ΔP SIZING
3 FLOW RATE KLPD 28 24 21
4 INLET PRESSURE Kg/cm2(g) 4.5
5 OUTLET PRESSURE Kg/cm2(g) 4.0
O
6 INLET TEMPERATURE C 100 100 100
7 SPEC WT/SPEC GRAV/MOL WT 0.834
8 VISCOSITY/SPEC HEAT RATIO cP 2.887
9 VAPOUR PRESSURE Pv Kg/cm2(g) 0.0133
10 REQUIRED Cv (Cg)
11 TRAVEL %
12 ALLOWABLE dBA ≤ 85 ≤ 85 ≤ 85
13 COMPRESSIBILITY FACTOR
17039-EK-P-DW-0203-11/
14 P&ID No & LINE No: 56 ACTUATOR (PNEUMATIC)
3"-HM-41-3736-BC01-1N
15 PIPE LINE SIZE IN / OUT 3"/ 3" 57 TYPE SPRING RETURN DIAPHRAGM
16 SCHEDULE mm STD 58 MFR & MODEL *
17 PIPE LINE INSULATION / STEAM TRACING 1 1/2" HEAT CONSERVATION / NA 59 SIZE * EFF AREA *
18 DESIGN PRESS. & TEMP. 12 & 250 60 ON/OFF NA MODULATING YES
19 61 MAX. STROKING TIME *
20 VALVE BODY/BONNET 62 SPRING ACTION OPEN/CLOSE CLOSE
21 TYPE VALVE SPEC GLOBE GVBC01R 63 MAX ALLOWABLE PRESSURE *
22 SIZE 2" 64 MIN REQUIRED PRESSURE *
23 MAX. PRESS./TEMP. TO SUIT DESIGN CONDITION 65 AVAILABLE AIR SUPPLY PRESSURE
24 MFR & MODEL * 66 MAX 8.5 NOR - MIN 6.5
25 SERIAL NUMBER * 67 BENCH RANGE Kg/cm2(g) *
26 BODY / BONNET MATERIAL CARBON STEEL A216 WCB 68 ACT ORIENTATION TOP
27 LINER MATERIAL/CORR. ALLOWANCE PTFE / 3mm 69 HANDWHEEL TYPE HEAVY DUTY
28 END CONNECTION IN : * / 300# RF 70 AIR FAILURE VALVE CLOSE
29 OUT : * / 300# RF 71 PNEUMATIC CONNECTION 1/4"
30 FLANGE FACE FINISH 125 - 250 AARH 72 DIAPHGRAM MATERIAL *
31 BONNET TYPE BOLTED 73 POSITIONER (41-TY-0992)
32 FLOW DIRECTION OVER 74 TYPE : ELECTRO-PNEUMATIC (SMART)
33 LUB & ISOLATION VALVE NA 75 MFR & MODEL *
34 PACKING MATERIAL EXPANDED GRAPHITE 76 ON INCR SIGNAL OUTPUT INCR/DECR NOTE-12
35 PACKING TYPE GRAFOIL 77 GAUGES BYPASS YES NO
36 78 CAM CHARACTERISTIC *

37 TRIM 79 HOUSING PROTECTION / MATERIAL IP 65, Ex "ia" / SS 316

38 TYPE STANDARD 80 PORT CONNECTION 1/4" NPT


39 SIZE RATED TRAVEL * * 81 AIRSET
40 CHARACTERISTIC EQUAL % 82 MFR & MODEL *
41 BALANCED/UNBALANCED UNBALANCED 83 SET PRESSURE (ADJUSTABLE) Kg/cm2(g)
42 RATED Cv * 84 FILTER ELEMENT GAUGES SINTERED BRONZE YES
43 PLUG MATERIAL A182 F316, STELLITED 85 FILTER SIZE 5 MICRON
44 SEAT MATERIAL A182 F316, STELLITED 86 AIRSET & FILTER MATERIAL SS 316
45 CAGE/GUIDE MATERIAL A182 F316, STELLITED 87 PNEUMATIC CONNECTION 1/4" NPT
46 STEM MATERIAL A182 F316, STELLITED 88 BOLT ADJUSTMENT SET POINT *
47 ACCESSORIES 89 TESTS
48 HAZARDOUS AREA CLASSIFICATION ZONE - 2, Gr IIA & IIB, T3 90 HYDRO TEST/ PRESSURE YES / 1.5 TIMES OF DESIGN PRESSURE
49 ENCLOSURE PROTECTION IP 65 91 ANSI/FCI LEAKAGE CLASS ANSI FCI 70.2 (LATEST REVISION) / Class IV
50 GAUGES SHALL BE IN 'Kg/cm2(g)' UNITS YES 92 CV / DEAD BAND TEST NA

51 CABLE ENTRY 1/2" NPTF 93 ACTUATOR LEAKAGE TEST NA

ASTM A 193 Gr. B7 / ASME B16.5 &


300# SPWND Gasket 4.5mm THK TO ASME B
52 STUD,BOLT, NUTS & GASKETS 94 CALIBRATION AND HYSTERESIS TEST NA
16.20: Windings - SS316, Filler- CNAF, Inner
Ring -SS316, Outer Ring- CS

53 TUBING: 1/4" 95 PERFORMANCE TEST NA

54 TUBE FITTING: 0.035" THICKNESS SS 316 96 FUNCTIONAL TEST FOR ALL ACCESSORIES REQUIRED

55 97 IBR CERTIFICATE REQUIRED, FORM IIIC


NOTES:- * - BY VENDOR

REFER NOTES SHEET.


TITLE ITEM/TAG No. DATA SHEET No.

DATASHEET FOR CONTROL VALVES 41-TV-0431 OIL-100-EK-I-DS-0807

PROJECT DESCRIPTION PROJECT NO SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 8 OF 10 A0

MPC CONTRACTOR PURCHASE ORDER No. REQUISITION No. SPECIFICATION No.

TBA - - 17039-EK-I-DB-8001

CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION

OIL INDIA LIMITED A0 VS 27-Nov-18 PGN 27-Nov-18 MV 27-Nov-18 ISSUED FOR REVIEW

CLIENT DOCUMENT No.

ORIGINATOR ORIG. DATE

VS 27-Nov-18
UNITS:- Pressure barg Kg/cm2(g) bara psi g Flow : Gas: MMSCFD Sm3/hr m3/hr kg/hr
0 0 3
Temp C F Liquid: m /hr kg/hr USGPM KLPD
1 FLUID OFFSPEC CRUDE OIL TYPE NON-CORROSIVE CRIT. PRESS : 14.5 kg/cm2
2 UNITS MAXIMUM FLOW NORMAL FLOW MINIMUM FLOW ΔP SHUTOFF ΔP SIZING
3 FLOW RATE KLPD 28 24 21
4 INLET PRESSURE Kg/cm2(g) 4.5
5 OUTLET PRESSURE Kg/cm2(g) 4.0
O
6 INLET TEMPERATURE C 100 100 100
7 SPEC WT/SPEC GRAV/MOL WT 0.834
8 VISCOSITY/SPEC HEAT RATIO cP 2.887
9 VAPOUR PRESSURE Pv Kg/cm2(g) 0.0133
10 REQUIRED Cv (Cg)
11 TRAVEL %
12 ALLOWABLE dBA ≤ 85 ≤ 85 ≤ 85
13 COMPRESSIBILITY FACTOR
17039-EK-P-DW-0203-14/ 3"-
14 P&ID No & LINE No: 56 ACTUATOR (PNEUMATIC)
HM-41-8612-BC01-1N
15 PIPE LINE SIZE IN / OUT 3"/ 3" 57 TYPE SPRING RETURN DIAPHRAGM
16 SCHEDULE mm STD 58 MFR & MODEL *
17 PIPE LINE INSULATION / STEAM TRACING 1" HEAT CONSERVATION / NA 59 SIZE * EFF AREA *
18 DESIGN PRESS. & TEMP. FOL+0.07 & 90 60 ON/OFF NA MODULATING YES
19 61 MAX. STROKING TIME *
20 VALVE BODY/BONNET 62 SPRING ACTION OPEN/CLOSE CLOSE
21 TYPE VALVE SPEC GLOBE GVBC01R 63 MAX ALLOWABLE PRESSURE *
22 SIZE 2" 64 MIN REQUIRED PRESSURE *
23 MAX. PRESS./TEMP. TO SUIT DESIGN CONDITION 65 AVAILABLE AIR SUPPLY PRESSURE
24 MFR & MODEL * 66 MAX 8.5 NOR - MIN 6.5
25 SERIAL NUMBER * 67 BENCH RANGE Kg/cm2(g) *
26 BODY / BONNET MATERIAL CARBON STEEL A216 WCB 68 ACT ORIENTATION TOP
27 LINER MATERIAL/CORR. ALLOWANCE PTFE/ 3mm 69 HANDWHEEL TYPE HEAVY DUTY
28 END CONNECTION IN : */ 300# RF 70 AIR FAILURE VALVE CLOSE
29 OUT : */ 300# RF 71 PNEUMATIC CONNECTION 1/4"
30 FLANGE FACE FINISH 125 - 250 AARH 72 DIAPHGRAM MATERIAL *
31 BONNET TYPE BOLTED 73 POSITIONER (41-TY-0431)
32 FLOW DIRECTION OVER 74 TYPE : ELECTRO-PNEUMATIC (SMART)
33 LUB & ISOLATION VALVE NA 75 MFR & MODEL *
34 PACKING MATERIAL EXPANDED GRAPHITE 76 ON INCR SIGNAL OUTPUT INCR/DECR NOTE-12
35 PACKING TYPE GRAFOIL 77 GAUGES BYPASS YES NO
36 78 CAM CHARACTERISTIC *

37 TRIM 79 HOUSING PROTECTION / MATERIAL IP 65, Ex "ia" / SS 316

38 TYPE STANDARD 80 PORT CONNECTION 1/4" NPT


39 SIZE RATED TRAVEL * * 81 AIRSET
40 CHARACTERISTIC EQUAL % 82 MFR & MODEL *
41 BALANCED/UNBALANCED UNBALANCED 83 SET PRESSURE (ADJUSTABLE) Kg/cm2(g)
42 RATED Cv * 84 FILTER ELEMENT GAUGES SINTERED BRONZE YES
43 PLUG MATERIAL A182 F316, STELLITED 85 FILTER SIZE 5 MICRON
44 SEAT MATERIAL A182 F316, STELLITED 86 AIRSET & FILTER MATERIAL SS 316
45 CAGE/GUIDE MATERIAL A182 F316, STELLITED 87 PNEUMATIC CONNECTION 1/4" NPT
46 STEM MATERIAL A182 F316, STELLITED 88 BOLT ADJUSTMENT SET POINT *
47 ACCESSORIES 89 TESTS
48 HAZARDOUS AREA CLASSIFICATION ZONE - 2, Gr IIA & IIB, T3 90 HYDRO TEST/ PRESSURE YES / 1.5 TIMES OF DESIGN PRESSURE
49 ENCLOSURE PROTECTION IP 65 91 ANSI/FCI LEAKAGE CLASS ANSI FCI 70.2 (LATEST REVISION) / Class IV
50 GAUGES SHALL BE IN 'Kg/cm2(g)' UNITS YES 92 CV / DEAD BAND TEST NA

51 CABLE ENTRY 1/2" NPTF 93 ACTUATOR LEAKAGE TEST NA

ASTM A 193 Gr. B7 / ASME B16.5 &


300# SPWND Gasket 4.5mm THK TO ASME B
52 STUD,BOLT, NUTS & GASKETS 94 CALIBRATION AND HYSTERESIS TEST NA
16.20: Windings - SS316, Filler- CNAF, Inner
Ring -SS316, Outer Ring- CS
53 TUBING: 1/4" 95 PERFORMANCE TEST NA

54 TUBE FITTING: 0.035" THICKNESS SS 316 96 FUNCTIONAL TEST FOR ALL ACCESSORIES REQUIRED

55 97 IBR CERTIFICATE REQUIRED, FORM IIIC


NOTES:- * - BY VENDOR

REFER NOTES SHEET.


TITLE ITEM/TAG No. DATA SHEET No.

DATASHEET FOR CONTROL VALVES 66-TV-6622 OIL-100-EK-I-DS-0807

PROJECT DESCRIPTION PROJECT NO SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 9 OF 10 A0

MPC CONTRACTOR PURCHASE ORDER No. REQUISITION No. SPECIFICATION No.

TBA - - 17039-EK-I-DB-8001

CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION

OIL INDIA LIMITED A0 VS 27-Nov-18 PGN 27-Nov-18 MV 27-Nov-18 ISSUED FOR REVIEW

CLIENT DOCUMENT No.

ORIGINATOR ORIG. DATE

VS 27-Nov-18
UNITS:- Pressure barg Kg/cm2(g) bara psi g Flow : Gas: MMSCFD Sm3/hr m3/hr kg/hr
0 0 3
Temp C F Liquid: m /hr kg/hr USGPM KLPD
1 FLUID SKIM OIL TYPE NON-CORROSIVE CRIT. PRESS : 14.5 kg/cm2
2 UNITS MAXIMUM FLOW NORMAL FLOW MINIMUM FLOW ΔP SHUTOFF ΔP SIZING
3 FLOW RATE KLPD 8.5 8 4.5
4 INLET PRESSURE Kg/cm2(g) 4.5
5 OUTLET PRESSURE Kg/cm2(g) 4.0
O
6 INLET TEMPERATURE C 100 100 100
7 SPEC WT/SPEC GRAV/MOL WT 0.834
8 VISCOSITY/SPEC HEAT RATIO cP 2.887
9 VAPOUR PRESSURE Pv Kg/cm2(g) 0.0133
10 REQUIRED Cv (Cg)
11 TRAVEL %
12 ALLOWABLE dBA ≤ 85 ≤ 85 ≤ 85
13 COMPRESSIBILITY FACTOR
17039-EK-P-DW-0206-04/
14 P&ID No & LINE No: 56 ACTUATOR (PNEUMATIC)
2"-HM-41-6642-BC01-1N
15 PIPE LINE SIZE IN / OUT 2"/ 2" 57 TYPE SPRING RETURN DIAPHRAGM
16 SCHEDULE mm XS 58 MFR & MODEL *
17 PIPE LINE INSULATION / STEAM TRACING 1 1/2" HEAT CONSERVATION / NA 59 SIZE * EFF AREA *
18 DESIGN PRESS. & TEMP. 12 & 250 60 ON/OFF NA MODULATING YES
19 61 MAX. STROKING TIME *
20 VALVE BODY/BONNET 62 SPRING ACTION OPEN/CLOSE CLOSE
21 TYPE VALVE SPEC GLOBE GVBC01Z 63 MAX ALLOWABLE PRESSURE *
22 SIZE 1" 64 MIN REQUIRED PRESSURE *
23 MAX. PRESS./TEMP. TO SUIT DESIGN CONDITION 65 AVAILABLE AIR SUPPLY PRESSURE
24 MFR & MODEL * 66 MAX 8.5 NOR - MIN 6.5
25 SERIAL NUMBER * 67 BENCH RANGE Kg/cm2(g) *
26 BODY / BONNET MATERIAL CARBON STEEL A216 WCB 68 ACT ORIENTATION TOP
27 LINER MATERIAL/CORR. ALLOWANCE PTFE/ 3mm 69 HANDWHEEL TYPE HEAVY DUTY
28 END CONNECTION IN : */ 300# RF 70 AIR FAILURE VALVE CLOSE
29 OUT : */ 300# RF 71 PNEUMATIC CONNECTION 1/4"
30 FLANGE FACE FINISH 125 - 250 AARH 72 DIAPHGRAM MATERIAL *
31 BONNET TYPE BOLTED 73 POSITIONER (66-TY-6622)
32 FLOW DIRECTION OVER 74 TYPE : ELECTRO-PNEUMATIC (SMART)
33 LUB & ISOLATION VALVE NA 75 MFR & MODEL *
34 PACKING MATERIAL EXPANDED GRAPHITE 76 ON INCR SIGNAL OUTPUT INCR/DECR NOTE-12
35 PACKING TYPE GRAFOIL 77 GAUGES BYPASS YES NO
36 78 CAM CHARACTERISTIC *

37 TRIM 79 HOUSING PROTECTION / MATERIAL IP 65, Ex "ia" / SS 316

38 TYPE STANDARD 80 PORT CONNECTION 1/4" NPT


39 SIZE RATED TRAVEL * * 81 AIRSET
40 CHARACTERISTIC EQUAL % 82 MFR & MODEL *
41 BALANCED/UNBALANCED UNBALANCED 83 SET PRESSURE (ADJUSTABLE) Kg/cm2(g)
42 RATED Cv * 84 FILTER ELEMENT GAUGES SINTERED BRONZE YES
43 PLUG MATERIAL A182 F316, STELLITED 85 FILTER SIZE 5 MICRON
44 SEAT MATERIAL A182 F316, STELLITED 86 AIRSET & FILTER MATERIAL SS 316
45 CAGE/GUIDE MATERIAL A182 F316, STELLITED 87 PNEUMATIC CONNECTION 1/4" NPT
46 STEM MATERIAL A182 F316, STELLITED 88 BOLT ADJUSTMENT SET POINT *
47 ACCESSORIES 89 TESTS
48 HAZARDOUS AREA CLASSIFICATION ZONE - 2, Gr IIA & IIB, T3 90 HYDRO TEST/ PRESSURE YES / 1.5 TIMES OF DESIGN PRESSURE
49 ENCLOSURE PROTECTION IP 65 91 ANSI/FCI LEAKAGE CLASS ANSI FCI 70.2 (LATEST REVISION) / Class IV
50 GAUGES SHALL BE IN 'Kg/cm2(g)' UNITS YES 92 CV / DEAD BAND TEST NA

51 CABLE ENTRY 1/2" NPTF 93 ACTUATOR LEAKAGE TEST NA

ASTM A 193 Gr. B7 / ASME B16.5 &


300# SPWND Gasket 4.5mm THK TO ASME B
52 STUD,BOLT, NUTS & GASKETS 94 CALIBRATION AND HYSTERESIS TEST NA
16.20: Windings - SS316, Filler- CNAF, Inner
Ring -SS316, Outer Ring- CS
53 TUBING: 1/4" 95 PERFORMANCE TEST NA

54 TUBE FITTING: 0.035" THICKNESS SS 316 96 FUNCTIONAL TEST FOR ALL ACCESSORIES REQUIRED

55 97 IBR CERTIFICATE REQUIRED, FORM IIIC


NOTES:- * - BY VENDOR

REFER NOTES SHEET.


TITLE ITEM/TAG No. DATA SHEET No.

DATASHEET FOR CONTROL VALVES 66-TV-6635 OIL-100-EK-I-DS-0807

PROJECT DESCRIPTION PROJECT NO SHEET REV

CREATION OF SURFACE PRODUCTION FACILITIES (GGS) AT EAST KHAGORIJAN KIP-17039 10 OF 10 A0

MPC CONTRACTOR PURCHASE ORDER No. REQUISITION No. SPECIFICATION No.

TBA - - 17039-EK-I-DB-8001

CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION

OIL INDIA LIMITED A0 VS 27-Nov-18 PGN 27-Nov-18 MV 27-Nov-18 ISSUED FOR REVIEW

CLIENT DOCUMENT No.

ORIGINATOR ORIG. DATE

VS 27-Nov-18
UNITS:- Pressure barg Kg/cm2(g) bara psi g Flow : Gas: MMSCFD Sm3/hr m3/hr kg/hr
0 0 3
Temp C F Liquid: m /hr kg/hr USGPM KLPD
1 FLUID OFF SPEC EFFLUENT WATER TYPE NON-CORROSIVE CRIT. PRESS : 14.5 kg/cm2
2 UNITS MAXIMUM FLOW NORMAL FLOW MINIMUM FLOW ΔP SHUTOFF ΔP SIZING
3 FLOW RATE KLPD 385 335 285
4 INLET PRESSURE Kg/cm2(g) 5
5 OUTLET PRESSURE Kg/cm2(g) ATM
O
6 INLET TEMPERATURE C 55 55 55
7 SPEC WT/SPEC GRAV/MOL WT
8 VISCOSITY/SPEC HEAT RATIO cP 4.932
9 VAPOUR PRESSURE Pv psia 2.472
10 REQUIRED Cv (Cg)
11 TRAVEL %
12 ALLOWABLE dBA ≤ 85 ≤ 85 ≤ 85
13 COMPRESSIBILITY FACTOR
17039-EK-P-DW-0206-06/
14 P&ID No & LINE No: 56 ACTUATOR (PNEUMATIC)
3"-WE-66-6661-AC01
15 PIPE LINE SIZE IN / OUT 3"/ 3" 57 TYPE SPRING RETURN DIAPHRAGM
16 SCHEDULE mm STD 58 MFR & MODEL *
17 PIPE LINE INSULATION / STEAM TRACING NA 59 SIZE * EFF AREA *
18 DESIGN PRESS. & TEMP. FOW+0.07 & 85 60 ON/OFF NA MODULATING YES
19 61 MAX. STROKING TIME *
20 VALVE BODY/BONNET 62 SPRING ACTION OPEN/CLOSE OPEN
21 TYPE VALVE SPEC GLOBE GVBC01R 63 MAX ALLOWABLE PRESSURE *
22 SIZE 2" 64 MIN REQUIRED PRESSURE *
23 MAX. PRESS./TEMP. TO SUIT DESIGN CONDITION 65 AVAILABLE AIR SUPPLY PRESSURE
24 MFR & MODEL * 66 MAX 8.5 NOR - MIN 6.5
25 SERIAL NUMBER * 67 BENCH RANGE Kg/cm2(g) *
26 BODY / BONNET MATERIAL CARBON STEEL A216 WCB 68 ACT ORIENTATION TOP
27 LINER MATERIAL/CORR. ALLOWANCE PTFE/ 3mm 69 HANDWHEEL TYPE HEAVY DUTY
28 END CONNECTION IN : */ 150# RF 70 AIR FAILURE VALVE OPEN
29 OUT : */ 150# RF 71 PNEUMATIC CONNECTION 1/4"
30 FLANGE FACE FINISH 125 - 250 AARH 72 DIAPHGRAM MATERIAL *
31 BONNET TYPE BOLTED 73 POSITIONER (66-TY-6635)
32 FLOW DIRECTION UNDER 74 TYPE : ELECTRO-PNEUMATIC (SMART)
33 LUB & ISOLATION VALVE NA 75 MFR & MODEL *
34 PACKING MATERIAL EXPANDED GRAPHITE 76 ON INCR SIGNAL OUTPUT INCR/DECR NOTE-12
35 PACKING TYPE GRAFOIL 77 GAUGES BYPASS YES NO
36 78 CAM CHARACTERISTIC *

37 TRIM 79 HOUSING PROTECTION / MATERIAL IP 65, Ex "ia" / SS 316

38 TYPE STANDARD 80 PORT CONNECTION 1/4" NPT


39 SIZE RATED TRAVEL * * 81 AIRSET
40 CHARACTERISTIC EQUAL % 82 MFR & MODEL *
41 BALANCED/UNBALANCED UNBALANCED 83 SET PRESSURE (ADJUSTABLE) Kg/cm2(g)
42 RATED Cv * 84 FILTER ELEMENT GAUGES SINTERED BRONZE YES
43 PLUG MATERIAL A182 F316, STELLITED 85 FILTER SIZE 5 MICRON
44 SEAT MATERIAL A182 F316, STELLITED 86 AIRSET & FILTER MATERIAL SS 316
45 CAGE/GUIDE MATERIAL A182 F316, STELLITED 87 PNEUMATIC CONNECTION 1/4" NPT
46 STEM MATERIAL A182 F316, STELLITED 88 BOLT ADJUSTMENT SET POINT *
47 ACCESSORIES 89 TESTS
48 HAZARDOUS AREA CLASSIFICATION ZONE - 2, Gr IIA & IIB, T3 90 HYDRO TEST/ PRESSURE YES / 1.5 TIMES OF DESIGN PRESSURE
49 ENCLOSURE PROTECTION IP 65 91 ANSI/FCI LEAKAGE CLASS ANSI FCI 70.2 (LATEST REVISION) / Class IV
50 GAUGES SHALL BE IN 'Kg/cm2(g)' UNITS YES 92 CV / DEAD BAND TEST NA

51 CABLE ENTRY 1/2" NPTF 93 ACTUATOR LEAKAGE TEST NA

ASTM A 193 Gr. B7 / ASME B16.5 &


150# SPWND Gasket 4.5mm THK TO ASME B
52 STUD,BOLT, NUTS & GASKETS 94 CALIBRATION AND HYSTERESIS TEST NA
16.20: Windings - SS316, Filler- CNAF, Inner
Ring -SS316, Outer Ring- CS
53 TUBING: 1/4" 95 PERFORMANCE TEST NA

54 TUBE FITTING: 0.035" THICKNESS SS 316 96 FUNCTIONAL TEST FOR ALL ACCESSORIES REQUIRED

55 97 IBR CERTIFICATE REQUIRED, FORM IIIC


NOTES:- * - BY VENDOR

REFER NOTES SHEET.


DATA SHEET FOR PRESSURE SAFETY VALVE
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (OCS) AT NADUA Datasheet No.
Code

DATA SHEET FOR PRESSURE SAFETY VALVE OIL-100-ND-I-DS-0808 A0 Sht.No:02 of 07

TABLE OF CONTENTS

Description Sheet Number

1. Cover Sheet 01 of 07
2. Index Sheet 02 of 07
3. Revision Sheet 03 of 07
4. Notes Sheet 04 of 07
5. DS-1 05 of 07
6. DS-2 06 of 07
7. DS-3 07 of 07
Revision Index
CREATION OF SURFACE PRODUCTION FACILITIES (OCS)
AT NADUA Rev
Datasheet No.
Code

DATA SHEET FOR PRESSURE SAFETY VALVE OIL-100-ND-I-DS-0808 A0 Sht.No: 03 of 07

REVISION List

Tenability for
Rev Rev Disc. Reasons Impact on MTO
extra Claim

A0 Issued for Review

HOLD List
Revision Index
CREATION OF SURFACE PRODUCTION
FACILITIES (OCS) AT NADUA Rev
Datasheet No.
Code
DATA SHEET FOR PRESSURE SAFETY VALVE OIL-100-ND-I-DS-0808 A0 04 of 07

Notes:
1. Documentation required :- Calibration Certificate,Material Certificates to 3.1 as per EN10204, Pressure test procedure/ Report,

NDT procedure / Report, Operating & Maintenance Instructions & Spare Parts List, Hydro Test, Pop test report & Installation

dimension Drawings.

2. All Instruments to be supplied with SS316 name plate with tag no. permanently inscribed. Tags shall be permanently

secured.

3. Nozzle,Seat and Disc for the above tags shall be forged.

4. All stud bolt and nut material shall be ASTM A193 Gr. B7M & Heavy hex nuts shall be ASTM A194 Gr. 2HM.

5. Painting shall be as per Protective Coating specification for Onshore Structures and Facilities.

6. All castings and welding shall be 100% radio graphed.

7. Carbon steel springs with Nickel plating shall be used for temperature services lower than 250 Deg C.

Tungsten alloy springs shall be used for temperatures greater than 250 Deg.C.

8. All relief valves of size 1" and above shall be full nozzle full lift type. Relief valves with size less than 1" shall be modified

nozzle type.

9. The pressure relief valve shall meet the requirements of API recommended practice RP 526 ‚Flanged Steel Safety Relief

Valves and RP 521‚ Pressure Relieving and Anti Pressurizing system and shall be of direct acting angle pattern,

full nozzle entry and high capacity type.


TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR PRESSURE SAFETY VALVE REFER BELOW OIL-100-ND-I-DS-0808
PROJECT DESCRIPTION PROJECT No. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (OCS) AT NADUA KIP-17039 05 OF 07 A0
MPC CONTRACTOR PURCHASE ORDER No. REQUISITION NO. SPECIFICATION No.
TBA - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED / TEC LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT DOCUMENT No.
-
ORIGINATOR ORIG. DATE
IMR 19-Sep-18
2 3
UNITS:- Pressure psig kg/cm g kPag barg Flow : Gas MMscfd MMSCMD Sm /hr kg/hr
O O
Temp C F Liquid: m3/hr kg/hr USgpm BLPD
1 TAG No. 20-PSV-1380A 20-PSV-1380B 41-PSV-3728A 41-PSV-3728B
Hot Oil Return to Hot Oil Hot Oil Return to Hot Oil Return Drum Hot oil to Hot Oil Drain Tank Hot oil to Hot Oil Drain Tank
2 SERVICE
Return Drum Bypass (ND-MBD-3320) (ND-MBD-3320) Bypass
3 VESSEL No. - - - -
GENERAL

4 LINE No. 2"-HM-41-3753-BC01 2"-HM-41-3753A-BC01 2"-HM-41-3734-BC01-1N 2"-HM-41-3734A-BC01-1N

5 P &ID NUMBER 17039-ND-P-DW-0202-20 17039-ND-P-DW-0202-20 17039-ND-P-DW-0203-10 17039-ND-P-DW-0203-10

6 FULL NOZZLE/SEMI-NOZZLE FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT

7 SAFETY / RELIEF / SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF

8 CONV., BELLOWS, PILOT OP. CONVENTIONAL CONVENTIONAL CONVENTIONAL CONVENTIONAL

9 BONNET TYPE CLOSED BONNET CLOSED BONNET CLOSED BONNET CLOSED BONNET
CONNECTION

10 SIZE INLET OUTLET 1" 2" 1" 2" 1" 2" 1" 2"

11 FL. RATING INLET OUTLET 300# 300# 300# 300# 300# 300# 300# 300#

12 FL. FACE INLET OUTLET RF RF RF RF RF RF RF RF

13 BODY CS, ASTM A105 CS, ASTM A105 CS, ASTM A105 CS, ASTM A105

14 BONNET CARBON STEEL CARBON STEEL CARBON STEEL CARBON STEEL

15 NOZZLE, SEAT and DISC SS 316 SS 316 SS 316 SS 316


MATERIAL

16 RESILIENT SEAT SEAL SS 316 SS 316 SS 316 SS 316

17 GUIDE AND RINGS SS 316 SS 316 SS 316 SS 316

18 SPRING CS with Nickle Plate CS with Nickle Plate CS with Nickle Plate CS with Nickle Plate

19 BELLOWS N/A N/A N/A N/A

20 CAP: SCREWED or BOLTED SCREWED SCREWED SCREWED SCREWED

21 LEVER: OPEN or PACKED N/A N/A N/A N/A


OPTIONS

22 TEST GAG REQUIRED REQUIRED REQUIRED REQUIRED

23 CODE API RP 520 API RP 520 API RP 520 API RP 520

24 BASIS THERMAL EXPANSION THERMAL EXPANSION THERMAL EXPANSION THERMAL EXPANSION

25 VESSEL SIZE DIA X T/T TBA TBA TBA TBA

26 FLUID STATE HOT OIL LIQUID HOT OIL LIQUID HOT OIL LIQUID HOT OIL LIQUID

27 REQUIRED CAPACITY (VAPOUR/LIQUID)

28 OPERATING S.G MOL. WEIGHT


29 OPER. PRESS SET PRESS ATM 12 ATM 12 5.5 12 5.5 12

30 OPER. TEMP REL. TEMP 27-50 27-50 200 200


31 CONSTANT
32 BACK PRESSURE VARIABLE
33 TOTAL
FLUID DATA

34 % ALLOWABLE OVER PRESSURE


35 OVER PRESSURE FACTOR
36 COMPRESSIBILITY FACTOR
37 LATENT HEAT OF VAPORIZATION (KJ/Kg)
38 RATIO OF SPECIFIC HEATS Cp / Cv
39 OPERATING VISCOSITY cP
40 VAPOUR GAS MASS FRACTION
41 BAROMETRIC PRESSURE
42 ENVIRONMENTAL FACTOR
43 VESSEL / WETTED
44 RATED CAPACITY
2
45 CALCULATED AREA inch * * * *

46 SELECTED AREA inch2 * * * *

47 ORIFICE DESIGNATION * * * *

48 MANUFACTURER * * * *

49 MODEL No. * * * *

50 NOTES:- * BY VENDOR

51 REFER NOTES SHEET


52
53
54
55
56
57
58
59
TITLE ITEM/TAG No. DATA SHEET No.
PRESSURE SAFETY VALVE REFER BELOW OIL-100-ND-I-DS-0808
PROJECT DESCRIPTION PROJECT No. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (OCS) AT NADUA KIP-17039 06 OF 07 A0
MPC CONTRACTOR PURCHASE ORDER No. REQUISITION NO. SPECIFICATION No.
TBA - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED / TEC LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT DOCUMENT No.
-
ORIGINATOR ORIG. DATE
IMR 19-Sep-18
2 3
UNITS:- Pressure psig kg/cm g kPag barg Flow : Gas MMscfd MMSCMD Sm /hr kg/hr
O O
Temp C F Liquid: m3/hr kg/hr USgpm BLPD
1 TAG No. 41-PSV-3729A 41-PSV-3729B 41-PSV-0121A 41-PSV-0121B
Hot oil to Hot Oil Drain Tank Hot oil to Hot Oil Drain Tank Hot oil return to Hot Oil Drain Drum HotHot oil return to Hot Oil Drain Drum
2 SERVICE
(ND-MBD-3320) (ND-MBD-3320) Bypass (ND-MBD-3320) (ND-MBD-3320) Bypass
3 VESSEL No. - - - -
GENERAL

4 LINE No. 2"-HM-41-3737-BC01-1N 2"-HM-41-3737A-BC01-1N 2"-HM-41-3671-BC01-1N 2"-HM-41-3671A-BC01-1N

5 P &ID NUMBER 17039-ND-P-DW-0203-11 17039-ND-P-DW-0203-11 17039-ND-P-DW-0203-14 17039-ND-P-DW-0203-14

6 FULL NOZZLE/SEMI-NOZZLE FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT

7 SAFETY / RELIEF / SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF

8 CONV., BELLOWS, PILOT OP. CONVENTIONAL CONVENTIONAL CONVENTIONAL CONVENTIONAL

9 BONNET TYPE CLOSED BONNET CLOSED BONNET CLOSED BONNET CLOSED BONNET
CONNECTION

10 SIZE INLET OUTLET 1" 2" 1" 2" 1" 2" 1" 2"

11 FL. RATING INLET OUTLET 300# 300# 300# 300# 300# 300# 300# 300#

12 FL. FACE INLET OUTLET RF RF RF RF RF RF RF RF

13 BODY CS, ASTM A105 CS, ASTM A105 CS, ASTM A105 CS, ASTM A105

14 BONNET CARBON STEEL CARBON STEEL CARBON STEEL CARBON STEEL

15 NOZZLE, SEAT and DISC SS 316 SS 316 SS 316 SS 316


MATERIAL

16 RESILIENT SEAT SEAL SS 316 SS 316 SS 316 SS 316

17 GUIDE AND RINGS SS 316 SS 316 SS 316 SS 316

18 SPRING CS with Nickle Plate CS with Nickle Plate CS with Nickle Plate CS with Nickle Plate

19 BELLOWS N/A N/A N/A N/A

20 CAP: SCREWED or BOLTED SCREWED SCREWED SCREWED SCREWED

21 LEVER: OPEN or PACKED N/A N/A N/A N/A


OPTIONS

22 TEST GAG REQUIRED REQUIRED REQUIRED REQUIRED

23 CODE API RP 520 API RP 520 API RP 520 API RP 520

24 BASIS THERMAL EXPANSION THERMAL EXPANSION THERMAL EXPANSION THERMAL EXPANSION

25 VESSEL SIZE DIA X T/T TBA TBA TBA TBA

26 FLUID STATE HOT OIL LIQUID HOT OIL LIQUID HOT OIL LIQUID HOT OIL LIQUID

27 REQUIRED CAPACITY (VAPOUR/LIQUID)

28 OPERATING S.G MOL. WEIGHT


29 OPER. PRESS SET PRESS 5.5 12 5.5 12 5.5 12 5.5 12

30 OPER. TEMP REL. TEMP 200 200 200 200


31 CONSTANT
32 BACK PRESSURE VARIABLE
33 TOTAL
FLUID DATA

34 % ALLOWABLE OVER PRESSURE


35 OVER PRESSURE FACTOR
36 COMPRESSIBILITY FACTOR
37 LATENT HEAT OF VAPORIZATION (KJ/Kg)
38 RATIO OF SPECIFIC HEATS Cp / Cv
39 OPERATING VISCOSITY cP
40 VAPOUR GAS MASS FRACTION
41 BAROMETRIC PRESSURE
42 ENVIRONMENTAL FACTOR
43 VESSEL / WETTED
44 RATED CAPACITY
2
45 CALCULATED AREA inch * * * *

46 SELECTED AREA inch2 * * * *

47 ORIFICE DESIGNATION * * * *

48 MANUFACTURER * * * *

49 MODEL No. * * * *

50 NOTES:- * BY VENDOR

51 REFER NOTES SHEET


52
53
54
55
56
57
58
59
TITLE ITEM/TAG No. DATA SHEET No.
PRESSURE SAFETY VALVE REFER BELOW OIL-100-ND-I-DS-0808
PROJECT DESCRIPTION PROJECT No. SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (OCS) AT NADUA KIP-17039 07 OF 07 A0
MPC CONTRACTOR PURCHASE ORDER No. REQUISITION NO. SPECIFICATION No.
TBA - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED / TEC LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT DOCUMENT No.
-
ORIGINATOR ORIG. DATE
IMR 19-Sep-18
2 3
UNITS:- Pressure psig kg/cm g kPag barg Flow : Gas MMscfd MMSCMD Sm /hr kg/hr
O O
Temp C F Liquid: m3/hr kg/hr USgpm BLPD
1 TAG No. 41-PSV-6624A 41-PSV-6624B
Hot oil retrun to Hot Oil Drain Hot oil retrun to Hot Oil Drain Tank
2 SERVICE
Tank (ND-MBD-3320) (ND-MBD-3320) By Pass
3 VESSEL No. - -
GENERAL

4 LINE No. 2"-HM-41-6637-BC01-1N 2"-HM-41-6856-BC01-1N

5 P &ID NUMBER 17039-ND-P-DW-0206-04 17039-ND-P-DW-0206-04

6 FULL NOZZLE/SEMI-NOZZLE FULL NOZZLE, FULL LIFT FULL NOZZLE, FULL LIFT

7 SAFETY / RELIEF / SAFETY RELIEF SAFETY RELIEF SAFETY RELIEF

8 CONV., BELLOWS, PILOT OP. CONVENTIONAL CONVENTIONAL

9 BONNET TYPE CLOSED BONNET CLOSED BONNET


CONNECTION

10 SIZE INLET OUTLET 1" 2" 1" 2"

11 FL. RATING INLET OUTLET 300# 300# 300# 300#

12 FL. FACE INLET OUTLET RF RF RF RF

13 BODY CS, ASTM A105 CS, ASTM A105

14 BONNET CARBON STEEL CARBON STEEL

15 NOZZLE, SEAT and DISC SS 316 SS 316


MATERIAL

16 RESILIENT SEAT SEAL SS 316 SS 316

17 GUIDE AND RINGS SS 316 SS 316

18 SPRING CS with Nickle Plate CS with Nickle Plate

19 BELLOWS N/A N/A

20 CAP: SCREWED or BOLTED SCREWED SCREWED

21 LEVER: OPEN or PACKED N/A N/A


OPTIONS

22 TEST GAG REQUIRED REQUIRED

23 CODE API RP 520 API RP 520

24 BASIS THERMAL EXPANSION THERMAL EXPANSION

25 VESSEL SIZE DIA X T/T TBA TBA

26 FLUID STATE HOT OIL LIQUID HOT OIL LIQUID

27 REQUIRED CAPACITY (VAPOUR/LIQUID)

28 OPERATING S.G MOL. WEIGHT


29 OPER. PRESS SET PRESS 12 12

30 OPER. TEMP REL. TEMP AMB AMB


31 CONSTANT
32 BACK PRESSURE VARIABLE
33 TOTAL
FLUID DATA

34 % ALLOWABLE OVER PRESSURE


35 OVER PRESSURE FACTOR
36 COMPRESSIBILITY FACTOR
37 LATENT HEAT OF VAPORIZATION (KJ/Kg)
38 RATIO OF SPECIFIC HEATS Cp / Cv
39 OPERATING VISCOSITY cP
40 VAPOUR GAS MASS FRACTION
41 BAROMETRIC PRESSURE
42 ENVIRONMENTAL FACTOR
43 VESSEL / WETTED
44 RATED CAPACITY
2
45 CALCULATED AREA inch * *

46 SELECTED AREA inch2 * *

47 ORIFICE DESIGNATION * *

48 MANUFACTURER * *

49 MODEL No. * *

50 NOTES:- * BY VENDOR

51 REFER NOTES SHEET


52
53
54
55
56
57
58
59
DATA SHEET FOR ACTUATED ON OFF VALVES
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (OCS) AT NADUA Datasheet Number
Code

DATA SHEET FOR ACTUATED ON OFF VALVES OIL-100-ND-I-DS-0814 A0 Sheet No.: 02 of 06

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS - SDV
6 SDV- LIST
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (OCS) AT NADUA Datasheet Number
Code

DATA SHEET FOR ACTUATED ON OFF VALVES OIL-100-ND-I-DS-0814 A0 Sheet No: 03 of 06

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (OCS)
Revision Index
AT NADUA Datasheet Number Rev Code

DATA SHEET FOR ACTUATED ON OFF VALVES OIL-100-ND-I-DS-0814 A0 Sheet No: 04 of 06

Notes:
1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test ,
operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
4. Orientation of the actuator will be along the pipe axis.
5. Valve body thickness shall be as per ASME B16.34 plus C.A.
6. All instrument painting shall be as per Painting Specification
7. All fastners including stud-bolts and nuts material shall be ASTM A193 Gr. B7/B7M & Heavy hex nuts shall be ASTM A194 Gr. 2H/2HM
with Zinc coated ( hot dipped ) according to ASME B16.5.
8. Air Filter Regulators shall be provided with manual drainage facility, an integral pressure gauge calibrated in barg. Body material shall be
SS316 and filter element is 5 micron size.
9. Flange finish shall be in accordance with ASNI B16.5, for Raised Face (RF) flanges and shall be smooth finish to 125-250 AARH
10. All actuator valves accessories like solenoid valve, filter regulator, etc. shall be mounted on the valve actuator and tubed by vendor
using bright annealed SS316 (ASTM A269) tubing, tube size shall be 10mm O.D. X 1mm W.T.minimum. All tube fittings shall be imperial
and 316 SS double compression type, SWAGELOK.
11. All components such as air filter regulators, limit switches, solenoid valve shall be factory mounted, tubed / wired in completely assemble
condition and bolted to a SS 316 mounting plate which is fixed to a support with SS316 bolts.
13. Spare cable entry shall be plugged with SS316 Ex'd' certified plug.
14. Actuator to be sized for maximum pressure drop equal to the valve design pressure with minimum instrument air supply pressure (5.5 barg).
15. Actuator shall be sized for 1.5 times the required seating torque of the valve when the valve is closed against maximum differential pressure.
16. Actuator shall be supplied with a pressure relief valve to protect the actuator from overpressure if the actuator design pressure is lower
than the maximum instrument air pressure indicated in the datasheet.
17. The valve stem and linkage mechanism shall be consistance with actuator torque characteristic. The maximum torque developed by actuator shall not exceed that
which can be safely sustained by the valve stem. Valve stem or shaft and its trim shall be of blowout proof design and be capable of withstanding the maximum
actuator torque/thrust.
18. The mounting of the actuator shall be suitable for supporting the actuator without external attachments and shall be capable of
resisting actuator's maximum torque force.
19. Limit switches shall be supplied with hermetically sealed NAMUR Inductive proximity switches.
All valves shall be provided with an integral open/close mechanical position indicator(yellow/black) which shall be clearly visible from all angles.
20. Solenoid valve shall have SS 316 body, trim with viton or equal resilient seat (to be anti-explosion decompression type) and surge
suppression diode integrally mounted in enclosure. Open port of solenoid valve shall fitted with a bug screen.
All valves shall be provided with an integral open/close mechanical position indicator(yellow/black) which shall be clearly visible from all angles.
20. Solenoid valve shall have SS 316 body, trim with viton or equal resilient seat (to be anti-explosion decompression type) and surge
suppression diode integrally mounted in enclosure. Open port of solenoid valve shall fitted with a bug screen.
21. Flying leads termination cable are not acceptable for solenoid valve and limit switches.
23. Hydrotest pressure and seat test pressure shall be as per ASME code requirement.
24. Vendor shall verify all sizing calculations to confirm datasheets, selection and shall conform with his quotation. Vendor is responsible to confirm that the
specified pneumatic ON/OFF valve will operate satisfactorily for the given service conditions.
25. Stroke time should not exceed 3 times body size (inches) in seconds or be less than body size (inches) in seconds. Maximum stroke time of any valve is 30 sec.
26. All electrical components shall be suitable for hazardous area with ingress protection IP 65 (min).
27. All Actuated ON/OFF Valve assemblies (valve, actuator, solenoid valve, air pressure regulator and valve position switches) shall be SIL- 2 certified.
28. The Valves above 25Kgs shall be provided with eye bolts as per the requirements for site handling.
29. Valve actuators assemblies shall be equipped with adjustable controls to regulate their stroking speed.
30. All ball valves over 2” shall incorporate anti-static feature ensuring electrical continuity between ball, stem and body.
31. Actuator colour coding shall be fail open valve-Green and fail close valve-Red.
32. All Casting & Welding shall be 100% Radio graphed.
34. Stem for ball valves shall be anti-blowout type and for floating ball valves, seat spring shall be provided.
35. Other auxiliary devices such as air lock relay, pilot relay, booster relay volume tank etc. shall be provided as parts of the actuating system in order to achieve
the required stroke-speed, fail safe action.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR ACTUATED ON OFF VALVES REFER ANNEXURE-1 OIL-100-ND-I-DS-0814
PROJECT DESCRIPTION VME PROJECT No SPECIFICATION No.
CREATION OF SURFACE PRODUCTION FACILITIES (OCS) AT NADUA KIP-17039 -
MPC CONTRACTOR SUPPLIER DOC.NO REQUISITION No. SHEET REV
TBA - - 05 of 06 A0
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED / TEC LIMITED A0 IMR 28-Nov-18 MV 28-Nov-18 MSR/ VSR 28-Nov-18 ISSUED FOR REVIEW
CLIENT DOC .No
-
ORIGINATOR ORIG. DATE
IMR 14-Sep-18
UNITS:- Pressure barg kg/cm2 g kPa g psi g Flow : Gas MMscfd SCMH Sm3/hr kg/hr
0 0
Temp C F Liquid: m3/hr kg./hr bpd USgpm
1 GENERAL 55 ACTUATOR (PNEUMATIC)
QUARTER TURN, SPRING RETURN DOUBLE ACTING
2 FLUID REFER ANNEXURE-1 56 TYPE PISTON
3 LINE No. REFER ANNEXURE-1 57 MFR *

4 P&ID No. REFER ANNEXURE-1 58 SIZE REFER ANNEXURE-1


5 LINE SIZE AND SCHEDULE REFER ANNEXURE-1 59 SPRING ACTION OPEN / CLOSE REFER ANNEXURE-1
6 CORROSION ALLOWANCE REFER ANNEXURE-1 60 MAX ALLOWABLE PRESSURE *
7 PROCESS CONDITIONS 61 MIN REQUIRED PRESSURE *
8 FLOW RATE NA 62 AIR FLUID PRESSURE -
O
9 OP. PRESSURE / OP. TEMP. ( barg/ C) NA 63 AVAILABLE AIR PR. MIN / NOR / MAX. 6 / 8 / 10 barg
10 SPEC. GRAV. NA 64 BREAK TORQUE RUN TORQUE REFER ANNEXURE-3
3
11 LIQ. DENSITY AT OP. PR & TEMP (kg/m ) NA 65 TIME OPEN CLOSE REFER ANNEXURE-3
12 VISCOSITY cP NA 66 ACTUATOR COLOUR YES
O
13 DESIGN TEMPERATURE ( C) REFER ANNEXURE-1 67 ACT ORIENTATION PARALLEL TO FLOW
14 DESIGN PRESSURE (barg) REFER ANNEXURE-1 68 HANDWHEEL TYPE -
15 Dp SHUT-OFF PRESSURE (bar) REFER ANNEXURE-1 69 AIR FAILURE VALVE SET AT -
16 APPLICABLE CODES AND SPECIFICATIONS 70 AIR CONSUMPTION *
17 DESIGN CODE API 6D 71 POSITION INDICATION (LOCAL) YES
18 FIRE-SAFE API-6FA /API 607/ BS 6755 72 POSITION INDICATION (REMOTE) YES - SEE LINES 75~83
19 SEAT LEAKAGE CLASS ANSI FCI 70.2, Class VI or Equal 73 ACCUMULATOR NOTE-35
20 VALVE (NOTE-30,31,32) 74 PNEUMATIC CONNECTION 1/4" NPTF
21 TYPE BALL VALVE 75 SWITCHES
22 SIZE / RATING (in) NB REFER ANNEXURE-1 76 TAG No. REFER ANNEXURE-1
23 FLANGE FACE FINISH REFER ANNEXURE-1 77 TYPE INDUCTIVE PROXIMITY SWITCH WITH NAMUR

24 CONFIGURATION REFER ANNEXURE-1 78 MFR & MODEL *


25 MATERIAL BODY REFER ANNEXURE-1 VALVE CODE 79 CONTACTS / RATING 24VDC @ 2 A
26 BALL REFER ANNEXURE-1 VALVE CODE 80 ACTUATION POINTS OPEN / CLOSE
27 STEM REFER ANNEXURE-1 VALVE CODE 81 ENCLOSURE Ex'ia' / IP 65

28 SEAT RING REFER ANNEXURE-1 VALVE CODE 82 ENCLOSURE MATERIAL SS316


29 SEAT INSERT REFER ANNEXURE-1 VALVE CODE 83 CABLE ENTRY ISO M20 X 1.5 mm (2 nos)
30 FIRE SEAL REFER ANNEXURE-1 VALVE CODE 84 PNEUMATIC PILOT VALVE
31 PACKING REFER ANNEXURE-1 VALVE CODE 85 TAG No.

32 BOLT / NUT REFER ANNEXURE-1 86 TYPE

33 OTHER SPECIFICATIONS - 87 AIR SUPPLY SIGNAL


34 RUN TORQUE BREAK TORQUE ANNEXURE-2 88 MFR & MODEL
35 BODY TEST PRESSURE 1.5 TIMES OF THE DESIGN PRESSURE 89 MANUAL RESET
36 SEAT TEST PRESSURE 1.1 TIMES OF THE DESIGN PRESSURE 90 MATERIAL BODY/HOUSING
37 LIMIT STOPS NO 91 PILOT ACTION
38 MFR * 92 PILOT CONNECTION
39 MODEL * 93 FILTER REGULATOR (NOTE-8)
40 ADDITIONAL INFORMATION 94 MFR & MODEL *
41 a) PNEUMATIC TUBE SIZE ¼” O.D. X 0.035” W.T 95 MATERIAL ENCLOSURE 316 SS IP 65
42 b) ALL CABLE ENTRIES ISO M20 X 1.5 mm 96 INTEGRAL PRESSURE GAUGE YES
43 c) ALL TUBES AND FITTINGS MATERIAL 316 SS, SEE LINES 50 97 DESIGN PRESSURE SET PRESSURE 10 barg *
44 d) AREA CLASSIFICATION ZONE 2, GROUP IIA& IIB,TEMP.CL T3 98 PORT SIZE 1/4" NPTF
45 SPEED CONTROLLER LOCAL INDICATOR. YES YES 99 SOLENOID VALVE (NOTE-20,21)
46 100 TAG No. REFER ANNEXURE-1
47 101 QTY REFER ANNEXURE-1
48 102 TYPE 3 / 2 -WAY, UNIVERSAL
49 LIMIT SWITCHES SHALL BE PROVIDED WITH INTEGRAL TERMINAL BLOCK 103 POWER SUPPLY 24 VDC, < 6 WATT, H COIL INSULATION
50 ALL TUBE FITTINGS SHALL BE IMPERIAL AND DOUBLE 104 ENCLOSURE TYPE EEx'd' / IP 65 ZONE 2, GROUP IIA& IIB,TEMP.CL T3

51 FERRULE COMPRESSION TYPE. 105 MFR & MODEL *


52 VENT/EXHAUST CONNECTIONS TO BE PROVIDED WITH BUG SCREEN 106 MANUAL RESET YES
53 107 MATERIAL BODY/HOUSING 316 SS
54 108 PORT SIZE CABLE ENTRY 1/4'' NPTF ISO 1/2" NPT(F) X 1.5 mm
NOTES:- * BY VENDOR
Refer Notes sheet
Document Title
Document No. Rev.
DATA SHEET FOR ACTUATED ON OFF CREATION OF SURFACE PRODUCTION FACILITIES (OCS) AT NADUA
VALVES OIL-100-ND-I-DS-0814 A0 Sheet No.: 06 of 06
LINE SIZE (in) / SCH FLANGE DESIGN LIMIT SWITCH / VALVE
DESIGN ΔP SHUTOFF SOLENOID SOLENOID NACE ACTUATOR
S.NO TAG NO P&ID No. LINE N0. FLUID VALVE SIZE (in) CONFIGURATION or WALL THK. / C.A RATING FINISH VALVE CODE PRESSURE FAIL POSITION LIMIT SWITCH TAG NO. ACTUATOR SIZE BOLT / NUT MATERIAL VALVE MODEL NO SOLENOID VALVE SCHEMATICS REV REMARKS
TEMP. (OC) PRESSURE (bar) VALVE TAG NO. VALVE QTY REQUIREMENT MODEL
(mm) (AARH) (kg/cm2g) MODEL NO NO.
ASTM A 193 Gr. B7 / ASTM A
1 41-SDV-3750 17039-ND-P-DW-0202-20 2"-HM-41-3762-BC01-HC-IN HOT OIL 2" GATE VALVE 2"/ XS/ 3 300# RF 125 - 250 GTBC01R FOW+0.07 108 FOW+0.07 FAIL CLOSE 41-ZSL/ZSH-3750 41-SDY-3750 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


2 41-SDV-3727 17039-ND-P-DW-0203-10 4"-HM-41-3725-BC01-1N HOT OIL 3" GATE VALVE 4"/ STD/ 3 300# RF 125 - 250 GTBC01R 12/FV 250 12/FV FAIL CLOSE 41-ZSL/ZSH-3727 41-SXV-3727 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


3 41-SDV-3730 17039-ND-P-DW-0203-11 3"-HM-41-3727-BC01-1N HOT OIL 3" GATE VALVE 3"/ STD/ 3 300# RF 125 - 250 GTBC01R FOW+0.07 90 FOW+0.07 FAIL CLOSE 41-ZSL/ZSH-3730 41-SXV-3730 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


4 41-SDV-3668 17039-ND-P-DW-0203-14 3"-HM-41-8611-BC01-1N HOT OIL 3" GATE VALVE 3"/ STD/ 3 300# RF 125 - 250 GTBC01R FOW+0.07 90 FOW+0.07 FAIL CLOSE 41-ZSL/ZSH-3668 41-SXV-3668 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

CLARIFIED/ ASTM A 193 Gr. B7 / ASTM A


5 66-SDV-6643A 17039-ND-P-DW-0206-02 4"-TW-66-6604-AC01 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW+0.07 80 FOW+0.07 FAIL CLOSE 66-ZSL/ZSH-6643A 66-SXV-6643A 1 * Not Required * * * * A0
TREATED WATER 194 Gr. 2H (ASME B16.5)

CLARIFIED/ ASTM A 193 Gr. B7 / ASTM A


6 66-SDV-6643B 17039-ND-P-DW-0206-02 4"-TW-66-6604-AC01 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW+0.07 80 FOW+0.07 FAIL CLOSE 66-ZSL/ZSH-6643B 66-SXV-6643B 1 * Not Required * * * * A0
TREATED WATER 194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


7 41-SDV-6623 17039-ND-P-DW-0206-04 2"-HM-41-3674-BC01-1N HOT OIL 2" GATE VALVE 2"/ XS/ 3 300# RF 125 - 250 GTBC01R 15 80 15 FAIL CLOSE 41-ZSL/ZSH-6623 41-SXV-6623 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

OFF-SPEC ASTM A 193 Gr. B7 / ASTM A


8 66-SDV-6640 17039-ND-P-DW-0206-06 4"-WE-66-6605-AC01 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW+0.07 80 FOW+0.07 FAIL CLOSE 66-ZSL/ZSH-6640 66-SXV-6640 1 * Not Required * * * * A0
EFFLUENT WATER 194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


9 53-SDV-5516 17039-ND-P-DW-0212-01 4"-WP-53-5504-AC01 WATER 4" FULL BORE/ FLOATING BALL 4"/ STD/ 3 150# RF 125 - 250 BFAC01R 7/FV 80 7/FV FAIL CLOSE 53-ZSL/ZSH-5516 53-SXV-5516 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


10 53-SDV-5636 17039-ND-P-DW-0212-01 4"-WP-53-5508B-AC01 WATER 4" FULL BORE/ FLOATING BALL 4"/ STD/ 3 150# RF 125 - 250 BFAC01R 7/FV 80 7/FV FAIL CLOSE 53-ZSL/ZSH-5636 53-SXV-5636 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

FRESH POTABLE ASTM A 193 Gr. B7 / ASTM A


11 53-SDV-5607 17039-ND-P-DW-0212-04 3"-WD-53-5534-AS20 3" FULL BORE/ FLOATING BALL 3"/ STD/ 3 150# RF 125 - 250 BFAS20R FOW+0.07 80 FOW+0.07 FAIL CLOSE 53-ZSL/ZSH-5607 53-SXV-5607 1 * Not Required * * * * A0
WATER 194 Gr. 2H (ASME B16.5)

FRESH POTABLE ASTM A 193 Gr. B7 / ASTM A


12 53-SDV-5630 17039-ND-P-DW-0212-04 4"-WD-53-5611B-AS20 4" FULL BORE/ FLOATING BALL 4"/ STD/ 3 150# RF 125 - 250 BFAS20R FOW+0.07 80 FOW+0.07 FAIL CLOSE 53-ZSL/ZSH-5630 53-SXV-5630 1 * Not Required * * * * A0
WATER 194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


13 71-SDV-7101 17039-ND-P-DW-0217-01 4"-WP-71-7101-AC01 WATER 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAG01R FOW 80 FOW FAIL CLOSE 71-ZSL/ZSH-7101 71-SXV-7101 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


14 56-XV-4010 17039-ND-P-DW-0207-01 4"-OW-56-5410-AC01 OILY WATER 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R 11/FV 100 11/FV FAIL CLOSE 56-ZSL/ZSH-4010 56-SXV-4010 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


15 56-XV-4009 17039-ND-P-DW-0207-01 4"-OW-56-4019-AC01 OILY WATER 4" GATE VALVE 4"/ STD/ 3 150# RF 125 - 250 GTAC01R 11/FV 100 11/FV FAIL CLOSE 56-ZSL/ZSH-4009 56-SXV-4009 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


16 71-XV-8008 17039-ND-P-DW-0217-01 2"-WP-53-4639A-AC01 WATER 2" GATE VALVE 2"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW 80 FOW FAIL CLOSE 71-ZSL/ZSH-8008 71-SXV-8008 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

ASTM A 193 Gr. B7 / ASTM A


17 71-XV-8009 17039-ND-P-DW-0217-01 2"-WP-53-4639B-AC01 WATER 2" GATE VALVE 2"/ STD/ 3 150# RF 125 - 250 GTAC01R FOW 80 FOW FAIL CLOSE 71-ZSL/ZSH-8009 71-SXV-8009 1 * Not Required * * * * A0
194 Gr. 2H (ASME B16.5)

* To be provided by vendor