Professional Documents
Culture Documents
Calisto 2250
Calisto 2250
®
Range
The CalistoPLUS2250 range offers outstanding performance in an easy to use portable package. As part
250ºC
of the ISOCAL-6 series the CalistoPLUS2250 can be used as a Dry Block, a Liquid Bath, a Blackbody
to 30ºC Source for infrared thermometers, a Surface Sensor Calibrator and for performance to a few mK
(0.001ºC) ITS-90 Fixed Points. The CalistoPLUS2250 is available in two models, the BASIC (B) and the
SITE (S). The B model includes a sophisticated temperature controller with a dual display for Set
Temperature and Dry Block Temperature, refer to page 27 for further details. The S model additionally
includes an in-built indicator to which an external temperature sensor can be connected.
For Dry Block use the unit under test may be compared to the controller value, Isotech recommend
the use of an external probe connected to the indicator of the Site model (see page 23) which
compensates for the temperature gradient and loading errors. This gives greater accuracy and
traceability meeting the requirements of ISO 9000 and other quality standards.
For Liquid Bath, Surface Sensor or Blackbody use an external thermometer should always be used -
either with the S model or the B model and a separate stand-alone indicator. For laboratory use the
CalistoPLUS2250 can be used with a laboratory performance temperature indicator such as one of the
Isotech True Temperature Indicators (TTI).
Includes as standard: Windows Software, Computer Interface and a Ramp to Set Point Feature.
Increased resolution of ±0.01 available throughout the range via the PC interface and from
-19.99 to +99.99 locally on the auto-ranging front display. The controller features multi-point
block to display correction giving good absolute accuracy.
The S model has universal sensor input allowing Platinum Resistance Thermometers,
Thermocouples (Types K, N, R, S, L, B, PL2, T, J and E) along with Linear Process Inputs including
4-20mA current transmitters to be displayed on the inbuilt indicator. The indicator can be
programmed with up to five calibration points to provide high accuracy digital probe matching.
The indicator and controller are both addressable over the communications link.
New! The Site model can now be used with the supplied Cal Notepad software to test
thermostats.
Key Features
three/20
Options CalistoPLUS 2250
®
1. Metal Block Insert 951-02-15 Standard Insert
Included
Range
951-02-15A Blank Insert
Insert without pockets for
local machining
951-02-15C Special Insert
Contact Isotech with your
requirements
5. Surface Sensor Kit 951-06-02 Includes an Insert and an Best Performance See Graph
angled PRT.
Calibration volume 35mm diameter by 160mm deep
6. Fixed Point Cells 17401 Slim Gallium Slim Cell
Standard Insert 6 pockets, 9.5mm, 8.0mm, 6.4mm,
6.4mm, 4.5mm, 4.5mm, all 157mm deep
UKAS Calibration UKAS Calibration available to Order
Uniformity ±0.018ºC
Standard Probe 935-14-82 Platinum Resistance
Thermometer Display Resolution 0.01 Up to 99.99
0.1 100.0 to 250.0ºC
Carrying Case 931-22-64 Sturdy case PC can display 0.01 across whole
accommodates the unit range with the software included
with room for accessories
Indicator units ºC, ºF, K
To see the ISOCAL-6 in use ask for our Power 100 to 120V (50 / 60 Hz) or
27 minute video supplied on CD-Rom 200 to 240V (50 / 60 Hz)
300 Watts
three/21