THERMAL SYSTEMS (HYDERABAD) PVT. LTD.

Ref. No. IGC/ER 347/Ø2


PLOT NO.158, I.D.A, BOLLARAM, HYDERABAD – 502325.
Date: 04.05.2020
TESTING REQUISITION

To: M/s. Jyothi Spectro Analysis Pvt. Ltd., Balanagar, Hyderabad

Please carryout the below tests for the PQR Coupon as per the ASME Section – IX and Project
Specification referred.

Test Piece Details:


Base Material: ER 347 Filler Wire – Weldpad
Standard designation: AWS A 5.9: ER 347
Manufacturer: Superon
Batch No. : T-8784
Brand Name: SUPER TIG 347-LDG
Welding Process: GTAW
Condition of Material: As Welded condition
Coupon Marked: IGC/ER 347/Ø2.0

Sl. Acceptance
Type of test Description of Test(s)
No. criteria

IGC Test of welding ASTM A262


1 IGC test shall be conducted on weld pad for welding consumable
consumable Practice-E

Follow the cutting plan attached for cutting of a coupon.


Balance test coupon, tested specimens have to return to THERMAL SYSTEMS

Regards

Surya Prakash B
GM – Q&WT

Page 1 of 1