Professional Documents
Culture Documents
TEST
TEST
TEST
QTY
3/11/2013
1
PANELS
building name
2 BUILDING 7
level
room name
room code
SPEVCİFİC DOOR
CODE
WİDTH
900
DESIGN
HEIGHT
DSIGN
WİDTH
900
JOB SITE
HEIGHT
JOB SITE
CHECK WIDHT
JOB SITE
CHECK HEIGHT
JOB SITE
INSTRUCTION TO JOB
SITE MANAGER
JOB SITE
CANNOT BREAK.
WALL THICKNESS
JOB SITE
WALL TYPE
JOB SITE
FRAME TYPE
JOB SITE
door code
C1 1
Frame mark
SA
Door mark
SB
shaft
Reinaerdt order
number
576271
Pos Nr
2
cabinets without
obstruction
ROOM NUMBER
IDENTIFICATION DOOR
373 C1 1
NUMBER
PROBLEM
YES
1
REPRODUCE FRAME
NO
2
REPRODUCE PANEL
NO
3
MISSING FRAME
4
MISSING PANEL
5
6 7 8 9 10
DAMAGED DOOR
OPENING WIDTH
WRONG FRAME
WRONG PANEL
STRUCTURAL
REMARK
CHECK
YES 2 X HINGE PROVISION ON FRAME AND HINGE PROVISION ON TOP PANEL IS NOT MATCHING! - 825
CORRECTION
STRUCTURAL
OPENING HEIGHT
2250
CHECK
0
COORDINATION height
CHECK
-70
COORDINATION width
Final structural
755
opening width
Final structural opening
Final structural
opening height
2250
BOS Drawing
BOS-ENG-NOD-001
TAB
PLDB
PLDH
FMB
721
FMH
2216
FMB2
FMH2
FMB3
FMH3
Door width
740
Door height
1116+1116
Remark
1 x LH & 1 x RH
HPL
BLACK
Core
TC
40
Door thickness
Hinges
V0026wf
Size 1
238
Size 2
627
Size 3
Size 1
238
Size 2
627
Lock
No
Vision panel (W x H)
Louver
Wall thickness profile
measured WALL
Production wall
CORRECTION
thickness
SPECIFIED
SPECIFIED SPECIFIED
WALL FRAME TYPE
WIDTH HEIGHT
THICKNESS
840 2250 (1125+1125) - 250 4 sided Corner frame (7cm subframe at job site)
Double or Singel
Dutch door
CORRECTION
HANDING
LH
fire rating
normal glass 30 x 40
t60 glass
description
1 1 1 1 1 1
D10 111 D10 112 D10 113 D10 114 D10 115 D10 116
1 1 1 1 1 1
D10 120 D10 121 D10 122 D10 123 D10 124 D10 125
1 1 1 1 1 1
D10 130 D10 131 D10 132 D10 133 D10 134 D10 135
1 1 1 1 1 1
D10 140 D10 141 D10 142 D10 143 D10 144 D10 145
1 1 1 1 1 1
D10 150 D10 151 D10 152 D10 153 D10 154 D10 155
1 1 1 1 1 1
D10 160 D10 161 D10 162 D10 163 D10 164 D10 165
1 1 1 1 1 1
D10 7 D10 8 D10 9
1 1 1 9
0
D10 16 D10 17 D10 18 D10 19
0
1 1 1 1 10
0
D10 26 D10 27 D10 28 D10 29 0
1 1 1 1 10
0
D10 36 D10 37 D10 38 D10 39 0
1 1 1 1 10
D10 46 D10 47 D10 48 D10 49 0
1 1 1 1 9
D10 56 D10 57 D10 58 D10 59 0
1 1 1 1 10
D10 66 D10 67 D10 68 D10 69 D10 70 0
1 1 1 1 10
D10 77 D10 78 D10 79 D10 80 0
1 1 1 1 10
D10 87 D10 88 D10 89 D10 90 0
1 1 1 1 10
D10 97 D10 98 D10 99 D10 100 0
1 1 1 1 10
D10 107 D10 108 D10 109 D10 110 0
1 1 1 1 10
0
D10 117 D10 118 D10 119 0
1 1 1
D10 126 D10 127 D10 128 D10 129 0
1 1 1 1 10
0
D10 136 D10 137 D10 138 D10 139 0
1 1 1 1 10
0
D10 146 D10 147 D10 148 D10 149 0
1 1 1 1 10
0
D10 156 D10 157 D10 158 D10 159 0
1 1 1 1 10
0
0
0
6
0
154
coloumn N PROBLEM
coloumn O REPRODUCE FRAME
coloumn P REPRODUCE PANEL
coloumn Q MISSING FRAME
coloumn R MISSING PANEL
coloumn S WRONG FRAME
coloumn T WRONG PANEL
coloumn U REMARK
coloumn V CHECK
coloumn W DAMAGED
160
130
332
100
7
4
1
734
NOT TO BE
REPRODUCED /
CED DUE TO MISSING AT PRODUCTION EXISTING CORRECT
SITE MISTAKES TO BE
SOLVED WITH
CARPENTER