JOINT OPERATIONS

SAUDI ARABIAN CHEVRON INC. - KUWAIT GULF OIL COMPANY (K.S.C).


MECHANICAL MAINTENANCE DIVISION
ROTATING EQUIPMENT CONDITION MONITORING VIBRATION REPORT - MGC- EOCENE
Inspected Date: 28.04.2019 REPORT No : RECM-VIB-36/19
CONDITION
VIBRATION READINGS IN MM/SEC (RMS) TEMPERATURE (°C)

Wrong rotation
Pending

Foundations

Instruments
SERVICE TAG REMARKS Recommendation

Couplings
DANGER
NORMAL

Cleaning
MNDE MDE PDE PNDE from

Sealing
ALERT
MNDE MDE PDE PNDE

Noise
H V A H V A H V A H V A
Maximum vibration readings are recorded at 6.6 mm/sec in the motor
non drive end bearing S
Equipment running speed was recorded as 2989 RPM.
Vibration spectrum indicated minor misalignment between the motor and
OP-301 pump & cavitation in the pump.
X 2.8 6.6 2.0 1.5 2.5 1.5 1.6 2.1 2.0 N/A N/A N/A 34 32 28 N/A
(P-202A) Minor abnormal noise was observed from the pump bearings.
Equipment full load current consumption was 101 Amps .
MGC -EOCENE

Pump suction pressure is 17 psi and discharge pressure is 28 psi.

CIRCULATING Recommendation: Keep monitoring the vibration trend in the equipment.


OIL COOLING
Maximum vibration readings are recorded at 3.0 mm/sec in the pump
PUMP drive end bearing in the normal. S
Equipment running speed was recorded as 2988 RPM.

Minor abnormal noise was observed from the pump internals.


OP-302
X 1.5 1.3 2.5 2.1 1.7 2.2 2.1 3.0 2.8 N/A N/A N/A 31 32 24 N/A Vibration spectrum indicated minor cavitation in the pump bearings.
(P-202B)
Equipment full load current consumption was 90 Amps .

Pump suction pressure is 17 psi and discharge pressure is 28 psi.

Vibration and temperature readings are maintaining trend.


Note: H - Horizontal, V - Vertical , A - Axial. MNDE - Motor Non Drive End, MDE - Motor Drive End, PDE - Pump Drive End, PNDE - Pump Non Drive End

RECMP Team 1/1