Technishield Pulse: E30/E60 Door and Screen System 03
Door Set: Vertical Section/Elevation – Single Leaf 04
Door Set: Horizontal Section – Single Leaf 05
Door Set: Vertical Section/Elevation – Single Leaf with Side Light on One Side 06
Door Set: Horizontal Section/Elevation – Single Leaf with Side Light on Both Sides 07
Door Set: Horizontal Section/Elevation – Double Leaf 08
Door Set: Horizontal Section/Elevation – Double Leaf with Side Light on Both Sides 09
Door & Side Light: Vertical Sections 10
Frame Joint Details 11
Handle Details 12
Abutment Details – Sections 13
Abutment Details – Sections 14
Abutment Details – Sections 15
Deflection Head Detail – Vertical Section 16
Head Locking Details – Vertical Sections 17
Base Locking Details – Vertical Section/Elevation 18
Technishield Pulse – Summary of Types 19
Technishield Pulse – General Specification 20
Technishield 25 & 54: 30/0 Partition System 21
Head Track Details: Vertical Sections 22
Base Track Details (Single-Glazed): Vertical Sections 23
Head & Base Track Details (Single-Glazed): Vertical Sections 24
Abutment Details (Single-Glazed): Horizontal Sections 25
Glass Joint Details (Single-Glazed): Horizontal Sections 26
Head Track Details (Double-Glazed): Vertical Sections 27
Base Track Details (Double-Glazed): Vertical Sections 28
Abutment Details (Double-Glazed): Horizontal Sections 29
Glass Joint Details (Double-Glazed): Horizontal Sections 30
Technishield System 25 & 54 – General Specification 31
Technishield System 25 & 54 – Component Selector 32
Technishield 50: E30/E60 Door and Screen System 33
Door Set: Vertical Section/Elevation – Single Leaf 34
Door Set: Vertical Section/Elevation – Single Leaf with Over-Panel 35
Door Set: Horizontal Section – Single Leaf 36
Continued overleaf

1
Contents (continued)

Door Set: Horizontal Section/Elevation – Double Leaf 37


Door Set: Horizontal Section/Elevation – Single Leaf with Side Light on One Side 38
Door Set: Horizontal Section/Elevation – Double Leaf with Over-Panel 39
Door Set: Horizontal Section/Elevation – Single Leaf with Over-Panel and Side Light on One Side 40
Side Panel: Vertical Sections 41
Door Set: Horizontal Section/Elevation – Double Leaf Non-Rebated Door 42
Technishield System 50 – Summary of Types 43
Technishield System 50 – General Specification 44
Technishield 65, 70 & 110: EI30 to EI120 Door and Screen System 45
EI30 Door Set: Vertical Section/Elevation – Single Leaf 46
EI30 Door Set: Vertical Section/Elevation – Single Leaf with Over-Panel 47
EI30 Door Set: Horizontal Section – Single Leaf 48
EI30 Door Set: Horizontal Section/Elevation – Double Leaf 49
EI30 Door Set: Horizontal Section/Elevation – Single Leaf with Side Light on One Side 50
EI30 Door Set: Horizontal Section/Elevation – Double Leaf with Over-Panel 51
EI30 Door Set: Horizontal Section/Elevation – Single Leaf with Over-Panel and Side Light on One Side 52
EI30 Side Panel: Vertical Sections 53
EI60 Door Set: Vertical Section/Elevation – Single Leaf 54
EI60 Door Set: Vertical Section/Elevation – Single Leaf with Over-Panel 55
EI60 Side Panel: Vertical Sections 56
EI60 Door Set: Horizontal Section/Elevation – Double Leaf Non-Rebated Door 57
Technishield System 65 – Summary of Types – EI30/EI60 58
Technishield System 65 – General Specification - EI30/EI60 59
EI90 Door Set: Vertical Section/Elevation – Single Leaf 60
EI90 Door Set: Horizontal Section – Single Leaf 61
EI90 Door Set: Horizontal Section/Elevation – Single Leaf with Side Light on One Side 62
EI90 Door Set: Horizontal Section/Elevation – Double Leaf 63
Technishield System 70 – Summary of Types – EI90 64
Technishield System 70 – General Specification – EI90 65
EI120 Fixed Screen: Elevation 66
EI120 Fixed Screen: Vertical Section 67
EI120 Fixed Screen: Horizontal Section 68
Technishield System 110 – Summary of Types – EI90 69
Technishield System 110 – General Specification – EI90 69
Specification: Stiffness 70
Specification: CDM Regulations 71
Specification: Building Regulations – Approved Document K 72
Contents

2
Technishield
Pulse
E30/E60 Door and
Screen System
Designer’s guide

ClearThinking
Technishield Pulse E30/E60
Door Set: Vertical Section/Elevation
50

10
70

3
90
90

10

Overall Aperture Width


Section through Technishield Pulse
Elevation showing Technishield Pulse E30/E60 single door set E30/E60 single door set on
on in-line pivot Part M Compliant clear opening in-line pivots
400201-01 400201-02
Technishield

4
Technishield Pulse E30/E60
Door Set: Horizontal Section

PART M Compliant Clear Opening

Door Leaf Width

29 29

89 89

Typical section – Technishield Pulse E30/E60 single door set with in-line pivot
Part M Compliant clear opening
400202-01
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
5 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield Pulse E30/E60
Door Set: Vertical Section/Elevation

50

10
70

3
90
90

10

Overall Aperture Width

Section through Technishield


Elevation showing Technishield Pulse E30/E60 single door Pulse E30/E60 single door set
on in-line pivot with side light Part M Compliant clear opening on in-line pivot
400203-01 400203-02
Technishield

6
Technishield Pulse E30/E60
Door Set: Horizontal Section/Elevation

Door Leaf Width


50

29 Horizontal section 29

400204-01

Elevation showing Technishield Pulse E30/E60 single door


on in-line pivot with side light both sides
400204-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
7 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield Pulse E30/E60
Door Set: Horizontal Section/Elevation

Door Leaf Width Door Leaf Width

29 29 29 29

89 89

Horizontal section
400205-01

Elevation showing Technishield Pulse E30/E60 double door set


on in-line pivots Part M Compliant clear opening
400205-02
Technishield

8
Technishield Pulse E30/E60
Door Set and Side Light: Horizontal Section/Elevation

Door Leaf Width Door Leaf Width

3
50

70 29 29 29 29 70

89 89

Horizontal section
400206-01

Elevation showing Technishield Pulse E30/E60 double door set on in-


line pivots with side lights – Part M Compliant clear opening
400206-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
9 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield Pulse E30/E60
Door and Side Light: Vertical Section

Section through Technishield Pulse E30/E60 Section through Technishield Pulse


door on in-line pivot E30/E60 side light
400207-01 400207-02
Technishield

10
Technishield Pulse E30/E60
Frame Joint Details: Elevations

50 50

Typical elevation – Technishield Pulse E30/E60


door frame – side light frame options
400208-01

50 50

Typical elevation – Technishield Pulse E30/E60


side light frame options
400208-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
11 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield Pulse E30/E60
Door Handle: Elevations

45
REQUIRED LENGTH
900 / 1200
600

45

Typical section – Technishield Pulse E30/E60


door handle options
400209-01
Technishield

12
Technishield Pulse E30/E60
Abutment Details: Horizontal Sections

10

70

Typical elevation – Technishield Pulse E30/E60


frame fixing to steel options
400210-01

10

70

Typical section – Technishield Pulse E30/E60


frame fixing to steel options
400210-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
13 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield Pulse E30/E60
Abutment Details: Sections

50

10
70

Typical section – Technishield Pulse E30/E60


frame fixing to concrete options
400211-01

10
50

70

Typical section – Technishield Pulse E30/E60


frame fixing to concrete options
400211-02
Technishield

14
Technishield Pulse E30/E60
Abutment Details: Sections

10
70

Typical section – Technishield Pulse E30/E60


frame fixing to stud wall
400212-01

10

70

Typical section – Technishield Pulse E30/E60


frame fixing to stud wall
400212-02

10

70

Typical section – Technishield Pulse E30/E60


frame fixing to stud wall
400212-03
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
15 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield Pulse E30/E60
Deflection Head Detail: Vertical Section

25
69

50

10

Typical section – Technishield Pulse E30/E60


deflection head ±25mm details
Technishield

400213-01

16
Technishield Pulse E30/E60
Head Locking Details: Vertical Sections

100

43

Typical head section – Technishield Pulse E30/E60


Maglock with stainless steel housing
400214-01

Typical head section – Technishield Pulse E30/E60


Dorma TS93S fitted on non-fire side
400214-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
17 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield Pulse E30/E60
Base Locking Details: Vertical Section/Elevation

Typical elevation detail showing Technishield Pulse E30/E60


door base rail dead lock on a double door set
400215-01

Typical section showing Technishield Pulse E30/E60


door base rail dead lock
400215-02
Technishield

18
Technishield Pulse E30/E60
SummaryPulse
Technishield of Types
E30/E60– Summary of Types

Single Door on In-Line Pivot (Single or Double Action)

DOOR ONLY DOOR WITH SIDE LIGHT ONE SIDE DOOR WITH SIDE LIGHT BOTH SIDES

Double Door on In-Line Pivot (Single or Double Action)

DOOR SET ONLY DOOR SET WITH SIDE LIGHT ONE SIDE DOOR SET WITH SIDE LIGHT BOTH SIDES

E30 Size Limits


Single Door Min Height = 1800mm / Max Height = 3000mm
Min Width = 940mm / Max Width = 1050mm
Double Door Min Height = 1800mm / Max Height = 3000mm
Min Width = 1800mm / Max Width = 2100mm
Side Panel Min Width = 300mm / Max Width = 1200mm
(Side Panels spigot onto the relevant door frame)

E60 Size Limits


Single Door Min Height = 1800mm / Max Height = 2600mm
Min Width = 940mm / Max Width = 1050mm
Double Door Min Height = 1800mm / Max Height = 2600mm
Min Width = 1800mm / Max Width = 2100mm
Side Panel Min Width = 300mm / Max Width = 1200mm
(Side Panels spigot onto the relevant door frame)
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
19 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield Pulse E30/E60
Technishield Pulse E30/E60 General Specification

Single & Double Door (For Internal Use Only)


Fire Rating: E30, 30 minutes integrity (30/0)
E60, 60 minutes integrity (60/0)

Ironmongery: As supplied to comply with the Fire Certificate

Pivot: Dorma In-Line Pivot

Handles: Stainless Steel Ø19mm Pull Handle with Ø50mm Stainless Steel Rose

Single Action Stops: Stainless Steel Plates located on Door Frame Head Profile

Maglock:

Maglock Housing: Stainless Steel Fabrication

Door Closer: TS-93 2-4

Door Seals: Sealmaster Ultima NR60 with Brush

Wet Glazing: Ceramic Tape (15 x 3mm) to suit Glass & Fire Rated Silicone/Intumescent

Tolerances: Height and Width: ± 1.5mm


Diagonals: ± 3.0mm

Finish: Stainless Steel/Powder Coated Finish for Interior Use

Packaging: Low Tack Adhesive to Front & Back Faces wrapped in Polywrap with cardboard protection

Carriage: Max of 2no. per Pallet

Side Panel (For Internal Use Only)

Fire Rating: E30S, 30 minutes integrity (30/0)


E60S, 60 minutes integrity (60/0)

Panel Fabrication: Combination of welded Frames & Spigot Jointed Horizontal Rails

Joint Options: Mitred or Butt Jointed Frames

Wet Glazing: Ceramic Tape (15 x 3mm or 15 x 6mm) to suit Glass & Black Fire Rated Silicone

Tolerances: Height and Width: ± 1.5mm


Diagonals: ± 3.0mm

Powder Coat: Standard Finish for Interior Use

Packaging: Low Tack Adhesive to Front & Back Faces wrapped in Polywrap with cardboard protection

Carriage: Max of 4no. per Pallet

Optima Products reserve the right to modify any details to reflect current practice and specifications
Technishield

20
Technishield
25 & 54
30/0 Screen System
Designer’s guide

ClearThinking
Technishield 25 & 54
Head Track Details: Vertical Sections
58

0271

69

94
30
25
0292

0296

15mm FIREGLASS

Offset single glazed head track with outer


upper channel ±25mm expansion/deflection
400002-01

25
40

0321
30

15mm FIREGLASS

Head track
central single glazed
400002-02
Technishield

22
Technishield 25 & 54
Base Track Details: Vertical Sections

15mm FIREGLASS

0299 0280

25
54

Offset single glazed floor track


400003-01

15mm FIREGLASS 15mm FIREGLASS

0256 0328 0325


25

25

25 25

Central single glazed floor track Central single glazed floor track
with 25mm floor angles 25mm x 25mm with clip-in bead
400003-02 400003-03
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
23 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 25 & 54
Head & Base Track Details: Vertical Sections
25

0320

50
30
15mm FIREGLASS

50mm head track


central single glazed
400007-01

15mm FIREGLASS

0326 0323
50

25

Central single glazed floor track


25mm x 50mm with clip-in bead
400007-02
Technishield

24
Technishield 25 & 54
Abutment Details: Horizontal Sections

15mm FIREGLASS
0295
Offset single glazed 25mm
wall abutment 54mm wide
400004-01
54

0298

25

15mm FIREGLASS

0322 Central single glazed


25mm wall abutment
25

400004-02

25
15mm FIREGLASS

0325 Central single glazed


25mm x 25mm wall abutment
with clip-in bead
25

0328 400004-03

25
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
25 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 25 & 54
Glass Joint Details (Single Glazed): Horizontal Sections

15mm FIREGLASS

22

15mm FIREGLASS
48

48

Glass to glass 90º corner joint

400006-01

15mm FIREGLASS
SS
LA
EG

90° - 179°
R
FI
m
m
15

variable
22

Glass to glass variable angle joint


15mm FIREGLASS

400006-02

5mm GAP
FIRE RATED SILICONE

Glass to glass silicone joint

400006-03
Technishield

26
Technishield 25 & 54
Head Track Details: Vertical Sections

58

0271

69

94
0460

0292

30
25
2121

2122

10.0 min
12.8 max 15mm FIREGLASS

Offset double glazed head track with outer


upper channel ±25 expansion/deflection
400008-01

54
50
30

0463

2121

2122

10.0 min
12.8 max 15mm FIREGLASS

50mm head track


double glazed
400008-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
27 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 25 & 54
Base Track Details: Vertical Sections
10.0 min
12.8 max 15mm FIREGLASS

2122
2121

20
0246

50
0464

54

50mm double glazed


floor track
400009-01

10.0 min
12.8 max 15mm FIREGLASS

2122
2121

0281
25

0462
54

25mm double glazed


floor track
400009-02
Technishield

28
Technishield 25 & 54
Abutment Details: Horizontal Sections

0464
0246

12.8 max
10.0 min
2121

Double glazed
2122 / 2205 50mm wall abutment
54

400010-01

15mm FIREGLASS
20

50

0462
0281
12.8 max
10.0 min

2121

Double glazed
2122 / 2205 25mm wall abutment
54

400010-02
15mm FIREGLASS

25
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
29 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 25 & 54
Glass Joint Details (Double Glazed): Horizontal Sections
10.0 min
15mm FIREGLASS 12.8 max

22

12.8 max
10.0 min
48

15mm FIREGLASS
48

Glass to glass 90º corner joint


400012-01
m in
.8 m
ax
12 0.0
1

12.8 max
10.0 min
90° - 179°
SS
LA
EG
R
FI
m
m
15

15mm FIREGLASS

variable
22

Glass to glass variable angle joint


400012-02

GLASS TO GLASS ALUMINIUM DRY JOINT


12.8 max
10.0 min

0060 - 12mm & 12.8mm glass 6


0077 - 10mm & 10.8mm glass
15mm FIREGLASS

5mm GAP
FIRE RATED SILICONE

Glass to glass silicone joint


400012-03
Technishield

30
Technishield 25 & 54
Technishield System 25 & 54 General Specification
Stiffness
The Optima Technishield partition system is designed to withstand the nominal crowd loadings that are likely to be present
in a typical office fit-out and where there is no change in level greater than 380mm between one side of the partition and
the other. The fracture stress of the glass and the integrity of the system should not be breached when subjected to the
following criteria:
Maximum Line Load at 1100mm AFL: 0.36kN/m
Maximum Glass Deflection from Vertical: L/120mm or 25mm, whichever is the least.
No allowance is made for any other simultaneous loads, such as internal wind loads etc. If other loads are required to be
catered for, please consult the Optima Technical Sales Team for advice.

Maximum Dimensions
The Optima Technishield system is available as follows:
Maximum Ceiling Height for Fixed Glazing (15mm Optima Fire Glass): 2850mm.
Maximum Height for 30/0 Timber Door Leaf: 2325mm. Maximum leaf width: 924mm (single leaf only). (Only the Optima
certified door may be used. Contact Optima for details.)
Maximum Glass Module Width: 1000mm.

Fire Performance
Optima Technishield provides 30/0 fire rating as a screen in isolation and when incorporating a 30/0 timber door leaf.

Smoke Performance
Optima Technishield 30/0 door set can provide FD30S for resistance to passage of smoke at ambient temperature. For
further information on door configuration, consult the Optima Technical Sales Team.

Acoustic Performance
All Optima systems are subjected to sound insulation tests in accordance with EN ISO 717-1:1997 at UKAS accredited
laboratories. These are optimised tests of the system only and not aggregate values for screen and door. The result is
expressed as an Rw value.
The Technishield partition system has achieved the following UKAS accredited acoustic values for the stated construct:

37dB (Rw) Test Ref: 542-430 15mm Optima Glass in single glazed multi-module screen
45dB (Rw) Assessed1 15mm Optima Fire Glass + 12.8mm acoustic laminate in double glazed multi-module screen
(1) Independently assessed against UKAS accredited test data.
It should be noted that in an on-site acoustic test, a partition may demonstrate a 3dB to 8dB lesser performance than
under laboratory conditions, depending on the partition type. This can be further affected by ambient noise levels on the
receiving side of the test sample and by poorly insulated abutments offering a ‘flanking’ path for audible sound.
For further information on potential aggregate values for screens with doors, or values for alternative glass types, consult
the Optima Technical Sales Team.

Live Load Deflection


With the increasing trend towards the use of lightweight building materials, Optima recognises the need to cater for the
resulting inevitable live load deflection of both structural slabs and perimeter curtain walling.
The Optima Technishield 25 and 54 partition systems have the capacity to accommodate the following levels of
asynchronous live load deflection:
Vertical Deflection: ±25mm as standard.
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
31 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 25 & 54
Component Selector
The following is a complete list of all the aluminium and plastic components that make up the Technishield 25 & 54
system, as annotated in this guide.

50mm DG 25mm Floor ±25mm Outer


0246 0256 0271
Glazing Bead Angle Deflection Head

25mm DG Glazing Inner Deflection


0280 25mm Floor Angle 0281 0292
Bead Head

SG Wall Abutment
0293 Door Jamb 0294 Door Head 0295
Channel

Deflection Head Door Jamb SG Wall Abutment SG


0296 0297 0298
SG Glazing Insert Glazing Insert Glazing Insert

Offset SG Base 50mm SG Head 25mm SG


0299 0320 0322
Channel Track Abutment

50mm SG Base 25mm SG Base & 50mm SG Glazing


0323 0325 0326
Track Abutment Track Bead

Deflection Head Door Jamb DG


0328 25mm SG 0460 0461
DG Glazing Insert Glazing Insert

25mm DG Base & 50mm DG Head 50mm DG Base &


0462 0463 0464
Abutment Track Track Abutment Track

Door Frame Non-FR Glazing Non-FR Glazing


2270 2121 2122
Gasket Gasket Gasket

No other components may be used to substitute for those described above. For specific advice on component usage,
consult the Optima Technical Sales Team.
Technishield

32
Technishield 50
E30/E60 Door and
Screen System
Designer’s guide

ClearThinking
Technishield 50
Door Set: Vertical Section/Elevation
50

10

70
110
130
50
Glass
Thickness
90

70
10

Overall Frame Width

Elevation showing Technishield Section through Technishield


System 50 single door set on hinges System 50 single door
Part M Compliant clear opening set on hinges

400101-01 400101-02
Technishield

34
Technishield 50
Door Set: Vertical Section/Elevation
50

60
10
80
Glass
Thickness

50
10
150

50
Glass
Thickness
90

70
10

Overall Frame Width

Elevation showing Technishield System 50 Section through Technishield


single door set on hinges with over panel System 50 single door set on
Part M Compliant clear opening hinges with over panel

400102-01 400102-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
35 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 50
Door Set: Horizontal Section

PART M Compliant Clear Opening

Door Leaf Width


50

10 10

10 50 50 50 50 10

Typical section – Technishield System 50 single door set on hinges


Part M Compliant clear opening

400103-01
Technishield

36
Technishield 50
Door Set: Horizontal Section

Active Door Leaf Width


Passive Door Leaf Width
50

10 10
10 50 50 90 50 50 10

Horizontal section
400104-01

Overall Frame Width

Elevation showing Technishield System 50 double door set on hinges


Part M Compliant clear opening

400104-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
37 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 50
Door Set: Horizontal Section

Door Leaf Width

70
50

10

10 50 90 50 50 10

Horizontal section
400105-01

Overall Frame Width

Elevation showing Technishield System 50 single door set on hinges


with side panel – Part M Compliant clear opening
Technishield

400105-02

38
Technishield 50
Door Set: Horizontal Section

Active Door Leaf Width


Passive Door Leaf Width
50

10 10
10 50 50 90 50 50 10

Horizontal section
400106-01

Overall Frame Width

Elevation showing Technishield System 50 double door set on hinges


with an over panel – Part M Compliant clear opening

400106-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
39 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 50
Door Set: Horizontal Section

Door Leaf Width

70
50

10

10 50 90 50 50 10

Horizontal section
400107-01

Overall Frame Width

Elevation showing Technishield System 50 single door set on hinges


with over and side panel – Part M Compliant clear opening

400107-02
Technishield

40
Technishield 50
Side Panel: Vertical Section/Elevation
50 50

10
10

50
50

70
70

Glass
Thickness
90

50

Glass
Thickness

Glass
Thickness
90
90

70
70

10
10

Section through Technishield System 50 Section through Technishield System 50


side panel for door set on hinges with over panel side panel for door set on hinges
400108-01 400108-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
41 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 50
Door Set: Horizontal Section

Door Leaf Width Door Leaf Width


50

10 10
10 50 50 50 50 10

90

Horizontal section
400109-01

Overall Frame Width

Elevation showing Technishield System 50 non-rebated double door set


on hinges – Part M Compliant clear opening

400109-02
Technishield

42
Technishield 50
Summary of Types
Single Door Latched with Hinges (Right Hand shown) Side Panels

SIDE PANELS
SPIGOT ONTO
THE DOOR FRAME

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT LH RH

Single Door Latched with Hinges & Over Panel (Right Hand shown) Side Panels

SIDE PANELS
SPIGOT ONTO
THE DOOR FRAME

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT LH RH

Double Door Latched with Hinges (Right Hand shown) Side Panels

SIDE PANELS
SPIGOT ONTO
THE DOOR FRAME

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT LH RH

Double Door Latched with Hinges & Over Panel (Right Hand shown) Side Panels

SIDE PANELS
SPIGOT ONTO
THE DOOR FRAME

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT LH RH

Non-Rebated Double Door

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT


Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
43 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 50
Technishield System 50 General Specification

Single & Double Door (For Internal Use Only)


Fire Rating: E30, 30 minutes integrity (30/0)
E60, 60 minutes integrity (60/0)
Ironmongery: As supplied to comply with the Fire Certificate
Hinges: Face Fitted Weld-on Hinges, 3 off per door
Handles: Forster Stainless Steel Lever Handle Set, Fire Rated, Cranked U-Form Steel Cored with 9mm
Spindle
Lock: Two Point Fire Rated Lever Latch with Euro-cylinder operated Deadlock
Slave Door Lock: Self Locking Drive Bolt, Two Point (Head & Base) (Double Door Set)
Euro Cylinder: Cylinder & Turn – 35mm/35mm
Door Closer: TS-93 2-4
Dropseal: Length to suit Door
Door Seals: Fire Protection Double Seal
Wet Glazing: Ceramic Tape (15 x 3mm or 15 x 6mm) to suit Glass & Black Fire Rated Silicone
Tolerances: Height and Width: ± 1.5mm
Diagonals: ± 4.0mm
Powder Coat: Standard Finish for Interior Use
Packaging: Low Tack Adhesive to Front & Back Faces wrapped in Polywrap with cardboard protection
Carriage: Max of 2no. per Pallet

Side Panel (For Internal Use Only)


Fire Rating: E30S, 30 minutes integrity (30/0)
E60S, 60 minutes integrity (60/0)
Panel Fabrication: Combination of welded Frames & Spigot Jointed Horizontal Rails
Wet Glazing: Ceramic Tape (15 x 3mm or 15 x 6mm) to suit Glass & Black Fire Rated Silicone
Tolerances: Height and Width: ± 1.5mm
Diagonals: ± 4.0mm
Powder Coat: Standard Finish for Interior Use
Packaging: Low Tack Adhesive to Front & Back Faces wrapped in Polywrap with cardboard protection
Carriage: Max of 4no. per Pallet

Size Limits
Single Door: Min Height = 1800mm / Max Height = 3000mm
Min Width = 955mm / Max Width = 1230mm
Double Door: Min Height = 1800mm / Max Height = 2900mm
Min Width = 1850mm / Max Width = 2800mm
Door with Over Panel: Min Height = 2200mm / Max Height = 4000mm
Note: Door height limits are the same for the Door with Over Panel range
Side Panel: Min Width = 300mm / Max Width = 1100mm
(Side Panels spigot onto the relevant door frame)

Optima Products reserve the right to modify any details to reflect current practice and specifications
Technishield

44
Technishield
65, 70 & 110
EI30 to EI120 Door
and Screen System
Designer’s guide

ClearThinking
Technishield 65
Door Set: Vertical Section/Elevation
65

10

70
110
130
50

Glass
Thickness
90

70
10

Overall Frame Width

Elevation showing Technishield System 65 EI30 Section through Technishield System


single door set on hinges – Part M Compliant 65 EI30 single door set on hinges
clear opening
400121-02
400121-01
Technishield

46
Technishield 65
Door Set: Vertical Section/Elevation
65

10

50
70
Glass
Thickness

50
10
150

50
Glass
Thickness
90

70
10

Overall Frame Width

Elevation showing Technishield System 65 EI30 single door set Section through Technishield
on hinges with over panel – Part M Compliant clear opening System 65 EI30 single door set on
hinges with over panel
400122-01
400122-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
47 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 65
Door Set: Horizontal Section

PART M Compliant Clear Opening


65

10 10

10 50 50 50 50 10

Door Leaf Width

Typical section – Technishield System 65 EI30 single door set on hinges


Part M Compliant clear opening

400123-01
Technishield

48
Technishield 65
Door Set: Horizontal Section
Active Door Leaf Width
Passive Door Leaf Width
65

10 87 10

10 50 50 50 50 10
Horizontal section
400124-01

Overall Frame Width

Elevation showing Technishield System 65 EI30 double door set on hinges


Part M Compliant clear opening

400124-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
49 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 65
Door Set: Horizontal Section
Door Leaf Width

70
65

10

10 50 90 50 50 10

Horizontal section
400125-01

Overall Frame Width

Elevation showing Technishield System 65 EI30 double door set on hinges


with an over panel – Part M Compliant clear opening

400125-02
Technishield

50
Technishield 65
Door Set: Horizontal Section

Active Door Leaf Width


Passive Door Leaf Width
65

10 90 10

10 50 50 50 50 10
Horizontal section
400126-01

Overall Frame Width

Elevation showing Technishield System 65 EI30 double door set on hinges


with an over panel – Part M Compliant clear opening

400126-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
51 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 65
Door Set: Horizontal Section

Door Leaf Width

70
65

10

10 50 90 50 50 10

Horizontal section
400127-01

Overall Frame Width

Elevation showing Technishield System 65 EI30 single door set on hinges


with over and side panel – Part M Compliant clear opening

400127-02
Technishield

52
Technishield 65
Side Panel: Vertical Section/Elevation
65 65

10
10

50
50

70
70

Glass
Thickness
50
90

Glass
Thickness

Glass
Thickness
90
90

70

70
10
10

Section through Technishield System 65 EI30 Section through Technishield


side panel for door set on hinges with over System 65 EI30 side panel for
panel door set on hinges

400128-01 400128-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
53 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 65
Door Set: Vertical Section/Elevation
65

10

70
110
130
50

Glass
Thickness
90

70
10

Overall Frame Width

Elevation showing Technishield System 65 EI60 single Section through Technishield


door set on hinges – Part M Compliant clear opening System 65 EI60 single door set on hinges

400129-01 400129-02
Technishield

54
Technishield 65
Door Set: Vertical Section/Elevation
65

10

50
70
Glass
Thickness

50
10
150

50
Glass
Thickness
90

70
10

Overall Frame Width

Elevation showing Technishield System 65 EI60 single door Section through Technishield
set on hinges with over panel – Part M Compliant clear System 65 EI60 single door set on
opening hinges with over panel

400130-01 400130-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
55 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 65
Side Panel: Vertical Section/Elevation
65 65

10

10
50

50
70

70
Glass
Thickness
90

50

Glass
Thickness

Glass
Thickness
90

90
70

70
10

10

Section through Technishield System 65 EI60 Section through Technishield System 65


side panel for door set on hinges with over EI60 side panel for door set on hinges
panel
400131-02
400131-01
Technishield

56
Technishield 65
Door Set: Horizontal Elevation
Door Leaf Width Door Leaf Width
65

10 10
70 70
10 70 90 70 10

Horizontal section
400132-01

Overall Frame Width

Elevation showing Technishield System 65 EI60 non-rebated double door


set on hinges – Part M Compliant clear opening

400132-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
57 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 65
Summary of Types

Single Door Latched with Hinges (Right Hand shown) Side Panels

SIDE PANELS
SPIGOT ONTO
THE DOOR FRAME

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT LH RH

Single Door Latched with Hinges & Over Panel (Right Hand shown) Side Panels

SIDE PANELS
SPIGOT ONTO
THE DOOR FRAME

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT LH RH

Double Door Latched with Hinges (Right Hand shown) Side Panels

SIDE PANELS
SPIGOT ONTO
THE DOOR FRAME

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT LH RH

Double Door Latched with Hinges & Over Panel (Right Hand shown) Side Panels

SIDE PANELS
SPIGOT ONTO
THE DOOR FRAME

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT LH RH

Non-Rebated Double Door

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT


Technishield

58
Technishield 65
Technishield System 65 General Specification

Single & Double Door


Fire Rating: EI30, 30 minutes integrity and Insulation (30/30)
EI60, 60 minutes integrity and Insulation (60/60)
Ironmongery: As supplied to comply with the Fire Certificate
Hinges: Face Fitted Weld-on Hinges, 3 off per door
Handles: Forster Stainless Steel Lever Handle Set, Fire Rated, Cranked U-Form Steel Cored with 9mm
Spindle
Lock: Two Point Fire Rated Lever Latch with Euro-cylinder operated Deadlock
Slave Door Lock: Self Locking Drive Bolt, Two Point (Head & Base) (Double Door Set)
Euro Cylinder: Cylinder & Turn – 35mm/35mm
Door Closer: TS-93 5-7
Dropseal: Length to suit Door
Door Seals: Fire Protection Double Seal
Wet Glazing: Ceramic Tape (15 x 3mm or 15 x 6mm) to suit Glass & Black Fire Rated Silicone
Tolerances: Height and Width: ± 1.5mm
Diagonals: ± 4.0mm
Powder Coat: Standard Finish for Interior Use
Packaging: Low Tack Adhesive to Front & Back Faces wrapped in Polywrap with cardboard protection
Carriage: Max of 2no. per Pallet

Side Panel (For Internal Use Only)


Fire Rating: EI30, 30 minutes integrity and Insul ation (30/30)
EI60, 60 minutes integrity and Insulation (60/60)
Panel Fabrication: Combination of welded Frames & Spigot Jointed Horizontal Rails
Wet Glazing: Ceramic Tape (15 x 3mm or 15 x 6mm) to suit Glass & Black Fire Rated Silicone
Tolerances: Height and Width: ±1.5mm
Diagonals: ± 4.0mm
Powder Coat: Standard Finish for Interior Use
Packaging: Low Tack Adhesive to Front & Back Faces wrapped in Polywrap with cardboard protection
Carriage: Max of 4no. per Pallet

Size Limits
Single Door: Min Height = 1800mm / Max Height = 3000mm
Min Width = 955mm / Max Width = 1460mm
Double Door: Min Height = 1800mm / Max Height = 2900mm
Min Width = 1850mm / Max Width = 2800mm
Door with Over Panel: Min Height = 2200mm / Max Height = 4000mm
Note: Door height limits are the same for the Door with Over Panel range
Side Panel: Min Width = 300mm / Max Width = 1100mm
(Side Panels spigot into the relevant door frame)

Optima Products reserve the right to modify any details to reflect current practice and specifications
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
59 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 70
Door Set: Vertical Section/Elevation
70

10

70
110
130
70

Glass
Thickness
90

90
70

10

Overall Frame Width

Elevation showing Technishield System 70 EI90 single door Section through Technishield System 70
set on hinges – Part M Compliant clear opening EI90 single door set on hinges
400141-01 400141-02
Technishield

60
Technishield 70
Door Set: Horizontal Section

PART M Compliant Clear Opening


70

10 10
70 70
10 70 70 10

Door Leaf Width

Typical section – Technishield System 70 EI90 single


door set on hinges – Part M Compliant clear opening

400142-01
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
61 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 70
Door Set: Horizontal Section

Door Leaf Width

70

70
10 10 63
70 90 10
10 70 70
Horizontal section
400143-01

Overall Frame Width

Elevation showing Technishield System 70 EI90 single door set on hinges


with side panel – Part M Compliant clear opening
Technishield

400143-02

62
Technishield 70
Door Set: Horizontal Section

10 10
70 90 70
10 70 70 70 10
Door Leaf Width Door Leaf Width

Horizontal section
400144-01

Overall Frame Width

Elevation showing Technishield System 70 EI90 double door


set on hinges – Part M Compliant clear opening

400144-02
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
63 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 70
Summary of Types

Single Door Latched with Hinges (Left Hand shown)

PLAIN LH SPIGOT RH SPIGOT LH & RH SPIGOT

Side Panels

SIDE PANELS SPIGOT


ONTO THE DOOR

LH RH
Technishield

64
Technishield 70
Technishield System 70 General Specification

Single & Double Door


Fire Rating: EI90, 90 minutes integrity and Insulation (90/90)
Ironmongery: As supplied to comply with the Fire Certificate
Hinges: Face Fitted Weld-on Hinges, 3 off per door
Handles: Forster Stainless Steel Lever Handle Set, Fire Rated, Cranked U-Form Steel Cored with 9mm
Spindle
Lock: Two Point Fire Rated Lever Latch with Euro-cylinder operated Deadlock
Euro Cylinder: Cylinder & Turn – 40mm/40mm
Door Closer: TS-93 5-7
Dropseal: Length to suit Door
Door Seals: Fire Protection Double Seal
Wet Glazing: Ceramic Tape (15 x 3mm or 15 x 6mm) to suit Glass & Black Fire Rated Silicone
Tolerances: Height and Width: ± 1.5mm
Diagonals: ± 4.0mm
Powder Coat: Standard Finish for Interior Use
Packaging: Low Tack Adhesive to Front & Back Faces wrapped in Polywrap with cardboard protection
Carriage: Max of 2no. per Pallet

Side Panel
Fire Rating: EI90, 90 minutes integrity and Insul ation (90/90)
Panel Fabrication: Combination of welded Frames & Spigot Jointed Horizontal Rails
Wet Glazing: Ceramic Tape (15 x 3mm or 15 x 6mm) to suit Glass & Black Fire Rated Silicone
Tolerances: Height and Width: ±1.5mm
Diagonals: ± 4.0mm
Powder Coat: Standard Finish for Interior Use
Packaging: Low Tack Adhesive to Front & Back Faces wrapped in Polywrap with cardboard protection
Carriage: Max of 4no. per Pallet

Size Limits
Single Door: Min Height = 1800mm / Max Height = 2320mm
Min Width = 955mm / Max Width = 1460mm
Side Panel: Min Width = 300mm / Max Width = 1100mm
(Side Panels spigot into the relevant door frame)

Optima Products reserve the right to modify any details to reflect current practice and specifications
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
65 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 110
Door Set: Vertical Section/Elevation

Aperture Width

O/A Screen Width

10 Gap 10 Gap
10

739.592 SPIGOT JOINTS


O/A Screen Height

A A
Aperture Height

739.592 FRAME SECURING


HOLE CRS.

739.593

739.592

B
10 Gap

Elevation showing Technishield System 110 EI120


partition only

400151-01
Technishield

66
Technishield 110
Door Set: Vertical Section/Elevation
110

10 Gap
70
Glass THK
EI120 Glass
90
50

90
10 Gap
70

50

Vertical section showing Technishield System 110 EI120


partition only

400152-01
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
67 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Technishield 110
Door Set: Vertical Section/Elevation

Glass THK
10 Gap
90 10 Gap
70
110

50 90 50

Horizontal section showing Technishield System 110 EI120


partition only

400153-01

Technishield

68
Technishield 110
Summary of Types and General Specification

Screen Option Only

Side Panel
Fire Rating: EI120, 120 minutes integrity and Insulation (120/120)

Panel Fabrication: Combination of welded Frames & Spigot Jointed Horizontal Rails

Wet Glazing: Ceramic Tape (15 x 3mm or 15 x 6mm) to suit Glass & Black Fire Rated Silicone

Tolerances: Height and Width: ±1.5mm


Diagonals: ± 4.0mm

Powder Coat: Standard Finish for Interior Use

Packaging: Low Tack Adhesive to Front & Back Faces wrapped in Polywrap with cardboard protection

Carriage: Max of 4no. per Pallet

Size Limits
Screen: Min Height = 1800mm / Max Height = 3380mm
Min Width = 300mm / Max Width = Unlimited
Standard Max = 2800mm x 1300mm per pane

Optima Products reserve the right to modify any details to reflect current practice and specifications
Technishield

© copyright Optima Courtyard House West End Road High Wycombe Bucks HP11 2QB
69 t: +44 (0) 1494 492 725 e: action@optima-group.co.uk www.optima-group.co.uk
Specification
Stiffness
Standards: BS 5234 – Parts 1 & 2
BS 6399 – Part 1

All Optima glazed partition systems are designed to withstand the nominal crowd loadings that
may be present in a typical office fit-out where there is no change in level greater than 380mm
between one side of the partition and the other.

The recognised standard for the design and installation of partitions is BS 5234. However, since
this standard was published, the nature of partition design has evolved to the extent that the
standard no longer accurately represents the product on the market. Part 2 of BS 5234 requires a
series of tests to demonstrate strength and robustness with the results defined as a ‘Duty Rating’.
Unlike the partition types covered in the scope of BS 5234, modern ‘frameless’ glazed partitions
are formed predominantly of glass and the testing regime cannot be reasonably applied.

Instead, Optima uses the known physical and structural characteristics of glass and specifies
appropriate partition glass based on calculation and with reference to BS 6399 – Part 1.
This standard suggests design loads that may act on the surface of a partition in a range of
environments. However, neither BS 6399, nor any other UK standard stipulates the maximum
degree of acceptable deflection under the design loads.

Every project is different and Optima considers each on its own merits and calculates the
type and thickness of glass accordingly. Without a guiding standard the degree of acceptable
deflection is extremely subjective. The Optima recommended criteria for maximum deflection are
L/120 or 25mm, whichever is the lesser value. This is in line with the International Building Code, a
US standard widely applied in many overseas regions, particularly the Middle East. These criteria
will ensure a high degree of stiffness in the partition glass.

A more relaxed set of criteria are commonly applied in the UK. These state that the maximum
acceptable deflection should be L/65 or 50mm, whichever is the lesser value. This would result
in a more flexible partition. Therefore it is important to ensure that the safe stress limit of the
glass is taken into account when specifying type and thickness. This is particularly important
when considering glazed partitions for projects and locations where there is less incentive for the
occupants to exercise care such as Public Sector buildings, particularly schools and hospitals.

Optima will consider both sets of deflection criteria when recommending glass on a project by
project basis and in consultation with designers and specifiers. For further information and advice
on glass specification, please contact the Optima Technical Sales Team.
Specification

70
Specification
CDM Regulations
In the absence of any specific legislation, Optima recommend that designers adopt the following
industry-typical design considerations:

Panel Size Breakage


• Can the panel be transported to site, • What would be the consequence of a panel
loaded out to the workface and installed? failure?
• Is there a suitable access route, • Is the panel in a safety critical location (e.g.
particularly if the glass is not located on an atrium barrier)?
the ground floor? • Should a fail safe condition be built into the
• Is it still possible to replace the panel after design?
• Is there risk to building occupants as a
the building is in service?
result of the breakage?
• Can the panel be replaced safely?
Panel Weight
Maintenance
• Can the panel be installed manually?
Optima generally consider one man • Can the installation be maintained safely
should not be expected to lift more and without undue risk?
than 25kg for a prolonged duration. • Is there a mechanism to protect the
However, every lift would have to be maintenance staff, such as safety harness
properly assessed for risk according to the anchorage points?
prevailing circumstances. As a guide, the
weight of glass should be calculated by Every project will throw up its own unique
challenges. The Optima Technical Sales Team
2.5kg x thickness (mm) x area (sq.m).
should be consulted at the earliest opportunity,
• If mechanical means to install would be
if there is any doubt that a scheme can be built
necessary, can this be achieved if the
and maintained safely.
panel needs to be replaced during the
lifespan of the building?
Specification

71
Specification
Building Regulations Approved Document K
(2013)
Glass Entrance Doors and Glazed Screens
• The location of glass entrance doors should be easily distinguished, especially when they are
within a glazed screen and when the door is both open and shut.
• Manifestation should be clearly contrasting with the background in all weather/lighting
conditions.
• Manifestation should be located between 850mm–1000mm and 1400mm–1600mm, i.e. in
150mm high bands which could be a solid band, a decorative feature or split bands of 50mm
each.
• High contrast strips at the top and on both sides of a glazed door in a glazed screen should be
provided.
• If glass doors can remain in the open position, the leading edge should be clearly distinguished
and protected by guarding (entrance doors only) to prevent it becoming a collision hazard.

Ceiling

1600mm
1400mm

1000mm
850mm

Floor

Manifestation must contrast visually with


150mm min the background seen through the glass in
both natural and artificial light conditions.
Specification

50mm min OR OR

72
Technishield
Designer’s Guide
Courtyard House
West End Road
High Wycombe
Buckinghamshire
HP11 2QB

t +44 (0) 1494 492 725


www.optimasystems.com

© Optima Products Limited 11/2018

You might also like