Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Project 1

Operator
Telephone
Fax
e-Mail

Office / Single Sheet Output

Height of Room: 2.900 m, Mounting Height: 2.947 m, Maintenance factor: Values in Lux, Scale 1:116
0.67

Surface r [%] Eav [lx] Emin [lx] Emax [lx]


Workplane / 570 375 634
Floor 20 505 273 615
Ceiling 80 107 91 133
Walls (4) 50 234 115 551

Workplane: UGR Lengthways- Across to luminaire axis


Height: 0.750 m Left Wall 14 13
Grid: 64 x 64 Points Lower Wall 14 14
Boundary Zone: 0.500 m (CIE, SHR = 1.00.)
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.415, Ceiling / Working Plane: 0.188.

Luminaire Parts List

No. Pieces Designation (Correction Factor) F (Luminaire) [lm] F (Lamps) [lm]


PHILIPS TBS464 SQR 3xTL5-14W HFP AC-
1 42 2556 3600
MLO (1.000)
Total: 107352 Total: 151200

Specific connected load: 14.80 W/m² = 2.60 W/m²/100 lx (Ground area: 130.50 m²)